{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:22:06Z","timestamp":1740108126608,"version":"3.37.3"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2021,11,4]],"date-time":"2021-11-04T00:00:00Z","timestamp":1635984000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,11,4]],"date-time":"2021-11-04T00:00:00Z","timestamp":1635984000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005713","name":"Technische Universit\u00e4t M\u00fcnchen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005713","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmologe"],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title><jats:sec>\n                <jats:title>Hintergrund<\/jats:title>\n                <jats:p>Die Beurteilung der intraoperativen Ver\u00e4nderung der Netzhautmorphologie, insbesondere des vitreoretinalen \u00dcberganges, ist mithilfe der intraoperativen optischen Koh\u00e4renztomografie (iOCT) m\u00f6glich geworden.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Ziel der Arbeit<\/jats:title>\n                <jats:p>Um die Bedeutung der intraoperativen Morphologie beim durchgreifenden Makulaforamen (MF) f\u00fcr das postoperative funktionelle Ergebnis zu evaluieren, wurde eine retrospektive, klinische Beobachtungsstudie durchgef\u00fchrt.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Material und Methoden<\/jats:title>\n                <jats:p>Die Netzhautmorphologie wurde in 32\u00a0Augen von 32\u00a0konsekutiven Patienten mit durchgreifendem Makulaforamen mittels iOCT zu verschiedenen Zeitpunkten w\u00e4hrend der Operation beobachtet. Die Ver\u00e4nderungen wurden anschlie\u00dfend mit dem postoperativen funktionellen Ergebnis korreliert.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Ergebnisse<\/jats:title>\n                <jats:p>Nach Induktion der hinteren Glask\u00f6rperabhebung (HGA) reduzierte sich der Makulaforamen-Index (MHI) um \u22120,05 (<jats:italic>p<\/jats:italic>\u202f=\u20090,01), die basale Foramenbreite (FB) stieg um +99,4\u202f\u03bcm (SD\u202f=\u2009197,8\u202f\u03bcm; <jats:italic>p<\/jats:italic>\u202f=\u20090,04). Die Verschlussrate betrug 100\u202f% zum Zeitpunkt der ersten postoperativen Vorstellung nach im Mittel 73\u00a0Tagen, der postoperative Visus verbesserte sich signifikant (<jats:italic>p<\/jats:italic>\u202f&lt;\u20090,05).<\/jats:p>\n                <jats:p>Es zeigte sich eine signifikant positive Korrelation von intraoperativer Morphologie und postoperativem Ergebnis zwischen einem niedrigen MHI und einem besseren postoperativen Visus (SKK\u202f=\u20090,50; <jats:italic>p<\/jats:italic>\u202f=\u20090,02), zwischen einer gro\u00dfen FB und einem besseren postoperativen Visus (SKK\u202f=\u20090,43; <jats:italic>p<\/jats:italic>\u202f=\u20090,05) sowie zwischen einer breiten Apertur nach HGA und einem gr\u00f6\u00dferen Visusanstieg postoperativ (SKK\u202f=\u20090,44; <jats:italic>p<\/jats:italic>\u202f=\u20090,03).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Diskussion<\/jats:title>\n                <jats:p>Wir konnten eine Abflachung sowie eine Verbreiterung des MF durch L\u00f6sen der vitreoretinalen Zugkr\u00e4fte beobachten. Aufgrund des Zusammenhangs zwischen einer gro\u00dfen intraoperativen FB mit einem besseren postoperativen Visus scheint die intraoperative Relaxierung der Netzhaut bedeutsam.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00347-021-01527-w","type":"journal-article","created":{"date-parts":[[2021,11,4]],"date-time":"2021-11-04T15:02:52Z","timestamp":1636038172000},"page":"491-496","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["iOCT in der klinischen Anwendung","iOCT in clinical use"],"prefix":"10.1007","volume":"119","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7062-7306","authenticated-orcid":false,"given":"Julia Sabina","family":"Friedrich","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nathalie","family":"Bleidi\u00dfel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali","family":"Nasseri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikolaus","family":"Feucht","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julian","family":"Klaas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chris Patrick","family":"Lohmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mathias","family":"Maier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,11,4]]},"reference":[{"issue":"7","key":"1527_CR1","doi-asserted-by":"publisher","first-page":"1759","DOI":"10.1007\/s00417-021-05082-7","volume":"259","author":"N Bleidi\u00dfel","year":"2021","unstructured":"Bleidi\u00dfel\u00a0N, Friedrich\u00a0J, Klaas\u00a0J et al (2021) Inverted internal limiting membrane flap technique in eyes with large idiopathic full-thickness macular hole: long-term functional and morphological outcomes. Graefes Arch Clin Exp Ophthalmol 259(7):1759\u20131771. https:\/\/doi.org\/10.1007\/s00417-021-05082-7","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1527_CR2","unstructured":"Carl Zeiss Meditec Technische Daten (2017) Available from: https:\/\/www.zeiss.de\/meditec\/produkte\/ophthalmologie\/katarakt\/visualisierung\/operationsmikroskope\/opmi-lumera-700.html#technische-daten. Zugegriffen: 13.11.2017"},{"key":"1527_CR3","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.1097\/IAE.0b013e3181b266bc","volume":"29","author":"PN Dayani","year":"2009","unstructured":"Dayani\u00a0PN, Maldonado\u00a0R, Farsiu\u00a0S et\u00a0al (2009) Intraoperative use of handheld spectral domain optical coherence tomography imaging in macular surgery. Retina 29:1457\u20131468","journal-title":"Retina"},{"key":"1527_CR4","doi-asserted-by":"publisher","first-page":"2611","DOI":"10.1016\/j.ophtha.2013.07.042","volume":"120","author":"JS Duker","year":"2013","unstructured":"Duker\u00a0JS, Kaiser\u00a0PK, Binder\u00a0S et\u00a0al (2013) The international vitreomacular traction study group classification of vitreomacular adhesion, traction, and macular hole. Ophthalmology 120:2611\u20132619","journal-title":"Ophthalmology"},{"key":"1527_CR5","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.1001\/jamaophthalmol.2015.2376","volume":"133","author":"JP Ehlers","year":"2015","unstructured":"Ehlers\u00a0JP, Goshe\u00a0J, Dupps\u00a0WJ et al (2015) Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER study RESCAN results. JAMA Ophthalmol 133:1124\u20131132","journal-title":"JAMA Ophthalmol"},{"key":"1527_CR6","doi-asserted-by":"publisher","first-page":"1329","DOI":"10.1136\/bjophthalmol-2014-305294","volume":"98","author":"JP Ehlers","year":"2014","unstructured":"Ehlers\u00a0JP, Kaiser\u00a0PK, Srivastava\u00a0SK (2014) Intraoperative optical coherence tomography using the RESCAN 700: preliminary results from the DISCOVER study. Br J Ophthalmol 98:1329\u20131332","journal-title":"Br J Ophthalmol"},{"key":"1527_CR7","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1167\/tvst.8.1.18","volume":"8","author":"JP Ehlers","year":"2019","unstructured":"Ehlers\u00a0JP, Uchida\u00a0A, Srivastava\u00a0SK et\u00a0al (2019) Predictive model for macular hole closure speed: insights from intraoperative optical coherence tomography. Transl Vis Sci Technol 8:18","journal-title":"Transl Vis Sci Technol"},{"key":"1527_CR8","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/IAE.0b013e318297daf3","volume":"34","author":"JP Ehlers","year":"2014","unstructured":"Ehlers\u00a0JP, Xu\u00a0D, Kaiser\u00a0PK et al (2014) Intrasurgical dynamics of macular hole surgery: an assessment of surgery-induced ultrastructural alterations with intraoperative optical coherence tomography. Retina 34:213\u2013221","journal-title":"Retina"},{"issue":"3","key":"1527_CR9","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s00347-020-01178-3","volume":"118","author":"J Friedrich","year":"2021","unstructured":"Friedrich\u00a0J, Bleidi\u00dfel\u00a0N, Klaas\u00a0J et\u00a0al (2021) Large macular hole \u2013 always a poor prognosis? Ophthalmologe 118(3):257\u2013263","journal-title":"Ophthalmologe"},{"issue":"9","key":"1527_CR10","doi-asserted-by":"publisher","first-page":"OCT1","DOI":"10.1167\/iovs.16-19963","volume":"57","author":"J Fujimoto","year":"2016","unstructured":"Fujimoto\u00a0J, Swanson\u00a0E (2016) The development, commercialization, and impact of optical coherence tomography. Invest Ophthalmol Vis Sci 57(9):OCT1\u2013OCT13","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1527_CR11","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1136\/bjo.2008.153189","volume":"93","author":"B Gupta","year":"2009","unstructured":"Gupta\u00a0B, Laidlaw\u00a0DA, Williamson\u00a0TH et\u00a0al (2009) Predicting visual success in macular hole surgery. Br J Ophthalmol 93:1488\u20131491","journal-title":"Br J Ophthalmol"},{"key":"1527_CR12","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1007\/s00347-016-0297-6","volume":"113","author":"LO Hattenbach","year":"2016","unstructured":"Hattenbach\u00a0LO, Framme\u00a0C, Junker\u00a0B et al (2016) Intraoperative real-time OCT in macular surgery. Ophthalmologe 113:656\u2013662","journal-title":"Ophthalmologe"},{"key":"1527_CR13","doi-asserted-by":"publisher","first-page":"571","DOI":"10.3928\/23258160-20180803-04","volume":"49","author":"M Hocaoglu","year":"2018","unstructured":"Hocaoglu\u00a0M, Muslubas\u00a0IS, Ersoz\u00a0MG et al (2018) First-operated and fellow eyes with bilateral idiopathic macular hole: comparison of anatomical and functional postoperative outcomes. Ophthalmic Surg Lasers Imaging Retina 49:571\u2013578","journal-title":"Ophthalmic Surg Lasers Imaging Retina"},{"key":"1527_CR14","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.ajo.2004.04.063","volume":"138","author":"S Kusuhara","year":"2004","unstructured":"Kusuhara\u00a0S, Teraoka Escano\u00a0MF, Fujii\u00a0S et\u00a0al (2004) Prediction of postoperative visual outcome based on hole configuration by optical coherence tomography in eyes with idiopathic macular holes. Am J Ophthalmol 138:709\u2013716","journal-title":"Am J Ophthalmol"},{"issue":"7","key":"1527_CR15","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1007\/s00347-018-0769-y","volume":"116","author":"M Maier","year":"2019","unstructured":"Maier\u00a0M, Bohnacker\u00a0S, Klein\u00a0J et al (2019) Vitrectomy and iOCT-assisted inverted ILM flap technique in patients with full thickness macular holes. Ophthalmologe 116(7):617\u2013624","journal-title":"Ophthalmologe"},{"key":"1527_CR16","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1007\/s00347-021-01340-5","volume":"118","author":"M Maier","year":"2021","unstructured":"Maier\u00a0M, Schumann\u00a0R, Friedrich\u00a0J et al (2021) Biomarkers in full-thickness and lamellar defects of the macula. Ophthalmologe 118:321\u2013336","journal-title":"Ophthalmologe"},{"key":"1527_CR17","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.1055\/s-0043-106304","volume":"235","author":"MM Maier","year":"2018","unstructured":"Maier\u00a0MM, Nasseri\u00a0A, Framme\u00a0C et\u00a0al (2018) Intraoperative optical coherence tomography in vitreoretinal surgery: clinical experiences and future developments. Klin Monatsbl Augenheilkd 235:1028\u20131034","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"1527_CR18","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/s40942-017-0094-7","volume":"3","author":"CH Meyer","year":"2017","unstructured":"Meyer\u00a0CH, Borny\u00a0R, Horchi\u00a0N (2017) Subretinal fluid application to close a\u00a0refractory full thickness macular hole. Int J Retin Vitr 3:44","journal-title":"Int J Retin Vitr"},{"key":"1527_CR19","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1007\/s00417-017-3598-9","volume":"255","author":"T Rossi","year":"2017","unstructured":"Rossi\u00a0T, Gelso\u00a0A, Costagliola\u00a0C et\u00a0al (2017) Macular hole closure patterns associated with different internal limiting membrane flap techniques. Graefes Arch Clin Exp Ophthalmol 255:1073\u20131078","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1527_CR20","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1007\/s00347-016-0250-8","volume":"113","author":"BV Stanzel","year":"2016","unstructured":"Stanzel\u00a0BV, Gagalick\u00a0A, Brinkmann\u00a0CK et\u00a0al (2016) Intraoperative OCT in ophthalmic microsurgery. Ophthalmologe 113:435\u2013442","journal-title":"Ophthalmologe"},{"key":"1527_CR21","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1136\/bjo.86.4.390","volume":"86","author":"S Ullrich","year":"2002","unstructured":"Ullrich\u00a0S, Haritoglou\u00a0C, Gass\u00a0C et\u00a0al (2002) Macular hole size as a\u00a0prognostic factor in macular hole surgery. Br J Ophthalmol 86:390\u2013393","journal-title":"Br J Ophthalmol"}],"container-title":["Der Ophthalmologe"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00347-021-01527-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00347-021-01527-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00347-021-01527-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,6]],"date-time":"2022-05-06T10:17:13Z","timestamp":1651832233000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00347-021-01527-w"}},"subtitle":["Korrelation von intraoperativer Morphologie und postoperativem Ergebnis bei Patienten mit durchgreifendem Makulaforamen","Correlation of intraoperative morphology and postoperative visual outcome in patients with full thickness macular hole"],"short-title":[],"issued":{"date-parts":[[2021,11,4]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,5]]}},"alternative-id":["1527"],"URL":"https:\/\/doi.org\/10.1007\/s00347-021-01527-w","relation":{},"ISSN":["0941-293X","1433-0423"],"issn-type":[{"type":"print","value":"0941-293X"},{"type":"electronic","value":"1433-0423"}],"subject":[],"published":{"date-parts":[[2021,11,4]]},"assertion":[{"value":"26 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 October 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 October 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"J.S.\u00a0Friedrich, N.\u00a0Bleidi\u00dfel, A.\u00a0Nasseri, N.\u00a0Feucht, J.\u00a0Klaas, C.P.\u00a0Lohmann und M.\u00a0Maier geben an, dass kein Interessenkonflikt besteht.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autoren keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}}]}}