{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T01:02:59Z","timestamp":1771894979552,"version":"3.50.1"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2023,8,2]],"date-time":"2023-08-02T00:00:00Z","timestamp":1690934400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,8,2]],"date-time":"2023-08-02T00:00:00Z","timestamp":1690934400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmologie"],"published-print":{"date-parts":[[2023,11]]},"DOI":"10.1007\/s00347-023-01886-6","type":"journal-article","created":{"date-parts":[[2023,8,2]],"date-time":"2023-08-02T19:01:41Z","timestamp":1691002901000},"page":"1122-1126","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Rebound-Tonometrie mit sterilisierten Sonden","Rebound tonometry with sterilized probes"],"prefix":"10.1007","volume":"120","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5936-1826","authenticated-orcid":false,"given":"Daniel M.","family":"Handzel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Ben Abdallah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Habie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Alani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W.","family":"Sekundo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,8,2]]},"reference":[{"key":"1886_CR1","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1136\/bjo.2005.089870","volume":"90","author":"ME Iliev","year":"2006","unstructured":"Iliev\u00a0ME, Goldblum\u00a0D, Katsoulis\u00a0K et\u00a0al (2006) Comparison of rebound tonometry with Goldmann applanation tonometry and correlation with central corneal thickness. Br J Ophthalmol 90:833\u2013835. https:\/\/doi.org\/10.1136\/bjo.2005.089870","journal-title":"Br J Ophthalmol"},{"key":"1886_CR2","doi-asserted-by":"publisher","first-page":"4578","DOI":"10.1167\/iovs.05-0586","volume":"46","author":"JM Martinez-de-la-Casa","year":"2005","unstructured":"Martinez-de-la-Casa\u00a0JM, Garcia-Feijoo\u00a0J, Castillo\u00a0A et al (2005) Reproducibility and clinical evaluation of rebound tonometry. Invest Ophthalmol Vis Sci 46:4578\u20134580. https:\/\/doi.org\/10.1167\/iovs.05-0586","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1886_CR3","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1007\/s00347-007-1487-z","volume":"104","author":"W Schreiber","year":"2007","unstructured":"Schreiber\u00a0W, Vorwerk\u00a0CK, Langenbucher\u00a0A et\u00a0al (2007) A comparison of rebound tonometry (ICare) with TonoPenXL and Goldmann applanation tonometry. Ophthalmologe 104:299\u2013304. https:\/\/doi.org\/10.1007\/s00347-007-1487-z","journal-title":"Ophthalmologe"},{"key":"1886_CR4","doi-asserted-by":"publisher","first-page":"1008","DOI":"10.1007\/s00347-012-2526-y","volume":"109","author":"V Witte","year":"2012","unstructured":"Witte\u00a0V, Glass\u00a0A, Beck\u00a0R et al (2012) Evaluation of the self-tonometer Icare ONE in comparison to Goldmann applanation tonometry. Ophthalmologe 109:1008\u20131013. https:\/\/doi.org\/10.1007\/s00347-012-2526-y","journal-title":"Ophthalmologe"},{"key":"1886_CR5","doi-asserted-by":"publisher","DOI":"10.1111\/aos.15256","author":"L Querat","year":"2022","unstructured":"Querat\u00a0L, Chen\u00a0E (2022) Impact of self-tonometry on glaucoma treatment decision. Acta Ophthalmol. https:\/\/doi.org\/10.1111\/aos.15256","journal-title":"Acta Ophthalmol"},{"key":"1886_CR6","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1007\/s00347-019-0908-0","volume":"116","author":"A Amani","year":"2019","unstructured":"Amani\u00a0A, Rosentreter\u00a0A, Dietlein\u00a0T et al (2019) Application of rebound self-tonometry for measurements in a\u00a0supine position. Ophthalmologe 116:766\u2013770. https:\/\/doi.org\/10.1007\/s00347-019-0908-0","journal-title":"Ophthalmologe"},{"key":"1886_CR7","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1097\/OPX.0b013e3182972df4","volume":"90","author":"S Nakakura","year":"2013","unstructured":"Nakakura\u00a0S, Mori\u00a0E, Yamamoto\u00a0M et\u00a0al (2013) Intraocular pressure of supine patients using four portable tonometers. Optom Vis Sci 90:700\u2013706. https:\/\/doi.org\/10.1097\/OPX.0b013e3182972df4","journal-title":"Optom Vis Sci"},{"key":"1886_CR8","doi-asserted-by":"publisher","first-page":"4571","DOI":"10.1167\/iovs.13-12303","volume":"54","author":"AI Dastiridou","year":"2013","unstructured":"Dastiridou\u00a0AI, Tsironi\u00a0EE, Tsilimbaris\u00a0MK et al (2013) Ocular rigidity, outflow facility, ocular pulse amplitude, and pulsatile ocular blood flow in open-angle glaucoma: a\u00a0manometric study. Invest Ophthalmol Vis Sci 54:4571\u20134577. https:\/\/doi.org\/10.1167\/iovs.13-12303","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"Suppl 4","key":"1886_CR9","first-page":"S102","volume":"95","author":"N Sayawat","year":"2012","unstructured":"Sayawat\u00a0N, Duangnumsawang\u00a0D (2012) Agreement and reproducibility of Tono-Pen XL tip covered with ocufilm and fingertip of surgical glove in intra-ocular pressure measurement. J\u00a0Med Assoc Thai 95(Suppl 4):S102\u2013S106","journal-title":"J Med Assoc Thai"},{"key":"1886_CR10","doi-asserted-by":"publisher","first-page":"e0239875","DOI":"10.1371\/journal.pone.0239875","volume":"15","author":"P Suvannachart","year":"2020","unstructured":"Suvannachart\u00a0P, Asawaphureekorn\u00a0S, Chansangpetch\u00a0S et al (2020) Repeatability, reproducibility, agreement, and safety of Tono-Pen tip cover for intraocular measurement using latex and polyethylene wrap. PLoS ONE 15:e239875. https:\/\/doi.org\/10.1371\/journal.pone.0239875","journal-title":"PLoS ONE"},{"key":"1886_CR11","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.jaapos.2016.01.003","volume":"20","author":"R Davis","year":"2016","unstructured":"Davis\u00a0R, Jiramongkolchai\u00a0K, Silverstein\u00a0E et al (2016) Rebound tonometry over an air-filled anterior chamber in the supine child after intraocular surgery. J\u00a0AAPOS 20:159\u2013164. https:\/\/doi.org\/10.1016\/j.jaapos.2016.01.003","journal-title":"J AAPOS"},{"key":"1886_CR12","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1016\/0002-9394(63)92431-0","volume":"55","author":"MA Galin","year":"1963","unstructured":"Galin\u00a0MA, Mc\u00a0IJ, Magruder\u00a0GB (1963) Influence of position on intraocular pressure. Am J Ophthalmol 55:720\u2013723","journal-title":"Am J Ophthalmol"},{"key":"1886_CR13","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.18240\/ijo.2022.08.07","volume":"15","author":"DM Handzel","year":"2022","unstructured":"Handzel\u00a0DM, Meyer\u00a0CH, Wegener\u00a0A (2022) Monitoring of central corneal thickness after phacoemulsification-comparison of statical and rotating Scheimpflug pachymetry, and spectral-domain OCT. Int J Ophthalmol 15:1266\u20131272. https:\/\/doi.org\/10.18240\/ijo.2022.08.07","journal-title":"Int J Ophthalmol"}],"container-title":["Die Ophthalmologie"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00347-023-01886-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00347-023-01886-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00347-023-01886-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,3]],"date-time":"2023-11-03T14:02:45Z","timestamp":1699020165000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00347-023-01886-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,2]]},"references-count":13,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2023,11]]}},"alternative-id":["1886"],"URL":"https:\/\/doi.org\/10.1007\/s00347-023-01886-6","relation":{},"ISSN":["2731-720X","2731-7218"],"issn-type":[{"value":"2731-720X","type":"print"},{"value":"2731-7218","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,2]]},"assertion":[{"value":"10 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 August 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"D.M.\u00a0Handzel, C.\u00a0Ben Abdallah, H.\u00a0Habie, A.\u00a0Alani und W.\u00a0Sekundo geben an, dass kein Interessenkonflikt besteht.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autor\/-innen keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}}]}}