{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T12:34:21Z","timestamp":1789562061137,"version":"build-2803163510"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T00:00:00Z","timestamp":1781049600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.de"},{"start":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T00:00:00Z","timestamp":1781049600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.de"}],"funder":[{"DOI":"10.13039\/501100018936","name":"Universit\u00e4tsklinikum Heidelberg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100018936","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ophthalmologie"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Hintergrund<\/jats:title>\n                    <jats:p>Presbyopie-korrigierende Intraokularlinsen (IOL) werden meist bilateral implantiert.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Fallbericht<\/jats:title>\n                    <jats:p>Bei einer 49-j\u00e4hrigen hoch myopen Patientin mit einseitiger Katarakt erfolgte die einseitige Implantation einer nichtdiffraktiven, Presbyopie-korrigierenden IOL.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Ergebnis<\/jats:title>\n                    <jats:p>Drei Monate postoperativ zeigten sich eine gute unkorrigierte Sehsch\u00e4rfe von der Ferne bis 40\u202fcm mit hoher Patientinnenzufriedenheit ohne relevante Dysphotopsien.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Schlussfolgerung<\/jats:title>\n                    <jats:p>Bei sorgf\u00e4ltiger Patientenselektion kann die einseitige Implantation moderner, Presbyopie-korrigierender IOL eine erfolgreiche Option darstellen.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00347-026-02460-6","type":"journal-article","created":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T18:44:15Z","timestamp":1781117055000},"page":"638-641","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Patientenselektion bei einseitiger Katarakt","Patient selection for unilateral cataract"],"prefix":"10.1007","volume":"123","author":[{"given":"Emma P.","family":"Freundt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emilia","family":"Andreas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grzegorz","family":"\u0141abuz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd U.","family":"Auffarth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3687-5082","authenticated-orcid":false,"given":"Timur M.","family":"Yildirim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,10]]},"reference":[{"issue":"8","key":"2460_CR1","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1097\/j.jcrs.0000000000001502","volume":"50","author":"F Ribeiro","year":"2024","unstructured":"Ribeiro\u00a0F, Dick\u00a0HB, Kohnen\u00a0T, Findl\u00a0O, Nuijts\u00a0R, Cochener\u00a0B, Fern\u00e1ndez\u00a0J (2024) Evidence-based functional classification of simultaneous vision intraocular lenses: seeking a\u00a0global consensus by the ESCRS Functional Vision Working Group. J\u00a0Cataract Refract Surg 50(8):794\u2013798","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"2460_CR2","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.survophthal.2019.02.012","volume":"64","author":"K Cao","year":"2019","unstructured":"Cao\u00a0K, Friedman\u00a0DS, Jin\u00a0S, Yusufu\u00a0M, Zhang\u00a0J, Wang\u00a0J, Hou\u00a0S, Zhu\u00a0G, Wang\u00a0B, Xiong\u00a0Y, Li\u00a0J, Li\u00a0X, He\u00a0H, Chai\u00a0L, Wan\u00a0XH (2019) Multifocal versus monofocal intraocular lenses for age-related cataract patients: a\u00a0system review and meta-analysis based on randomized controlled trials. Surv Ophthalmol 64(5):647\u2013658","journal-title":"Surv Ophthalmol"},{"issue":"11","key":"2460_CR3","doi-asserted-by":"publisher","first-page":"e132","DOI":"10.1016\/j.ophtha.2020.08.025","volume":"128","author":"E Yeu","year":"2021","unstructured":"Yeu\u00a0E, Cuozzo\u00a0S (2021) Matching the Patient to the Intraocular Lens: Preoperative Considerations to Optimize Surgical Outcomes. Ophthalmology 128(11):e132\u2013e141","journal-title":"Ophthalmology"},{"issue":"9","key":"2460_CR4","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s00347-024-02071-z","volume":"121","author":"GU Auffarth","year":"2024","unstructured":"Auffarth\u00a0GU, \u0141abuz\u00a0G, Khoramnia\u00a0R, Yildirim\u00a0TM (2024) \u00dcbersicht \u00fcber Intraokularlinsen mit Presbyopie-korrigierenden Optiken [Overview of intraocular lenses with optics for correcting presbyopia]. Ophthalmologie 121(9):685\u2013697","journal-title":"Ophthalmologie"},{"key":"2460_CR5","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-015-0089-9","volume":"15","author":"FT Kretz","year":"2015","unstructured":"Kretz\u00a0FT, M\u00fcller\u00a0M, Gerl\u00a0M, Gerl\u00a0RH, Auffarth\u00a0GU (2015) Binocular function to increase visual outcome in patients implanted with a diffractive trifocal intraocular lens. BMC Ophthalmol 15:110","journal-title":"BMC Ophthalmol"},{"issue":"4","key":"2460_CR6","doi-asserted-by":"publisher","first-page":"246","DOI":"10.3928\/1081597X-20130318-03","volume":"29","author":"KT Tsaousis","year":"2013","unstructured":"Tsaousis\u00a0KT, Plainis\u00a0S, Dimitrakos\u00a0SA, Tsinopoulos\u00a0IT (2013) Binocularity enhances visual acuity of eyes implanted with multifocal intraocular lenses. J\u00a0Refract Surg 29(4):246\u2013250","journal-title":"J Refract Surg"},{"issue":"7","key":"2460_CR7","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1136\/bjo-2024-326592","volume":"109","author":"ML Passaro","year":"2025","unstructured":"Passaro\u00a0ML, Kilic\u00a0D, Virgili\u00a0G, Romano\u00a0V, Lucenteforte\u00a0E, Dick\u00a0B, Taneri\u00a0S (2025) Retinal detachment incidence in refractive lens exchange versus cataract surgery: uncommon versus rare - systematic review and meta-analysis. Br J Ophthalmol 109(7):756\u2013764","journal-title":"Br J Ophthalmol"},{"issue":"1","key":"2460_CR8","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1097\/ICU.0b013e32834cd5d1","volume":"23","author":"MA Nanavaty","year":"2012","unstructured":"Nanavaty\u00a0MA, Daya\u00a0SM (2012) Refractive lens exchange versus phakic intraocular lenses. Curr Opin Ophthalmol 23(1):54\u201361","journal-title":"Curr Opin Ophthalmol"},{"issue":"3","key":"2460_CR9","first-page":"167","volume":"7","author":"C Ozturkmen","year":"2022","unstructured":"Ozturkmen\u00a0C, Kesim\u00a0C, Sahin\u00a0A (2022) Evaluation of Vision-Related Quality of Life After Unilateral Implantation of a New Trifocal Intraocular Lens. Beyoglu Eye J 7(3):167\u2013172","journal-title":"Beyoglu Eye J"},{"issue":"1","key":"2460_CR10","doi-asserted-by":"publisher","first-page":"62","DOI":"10.5455\/aim.2023.31.62-67","volume":"31","author":"M Bohac","year":"2023","unstructured":"Bohac\u00a0M, Jagic\u00a0M, Biscevic\u00a0A, Lukacevic\u00a0S, Mravicic\u00a0I, Suic\u00a0SP, Dekaris\u00a0I (2023) Stereoacuity and Multifocal Intraocular Lenses - a Systematic Review. Acta Inform Med 31(1):62\u201367","journal-title":"Acta Inform Med"},{"key":"2460_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-21282-7","volume-title":"Multifocal intraocular lenses: the art and the practice","author":"J Ali\u00f3","year":"2019","unstructured":"Ali\u00f3\u00a0J, Pikkel\u00a0J (2019) Multifocal Intraocular Lenses: Neuroadaptation. In: Ali\u00f3\u00a0J (Hrsg) Multifocal intraocular lenses: the art and the practice. Springer International Publishing, Berlin"},{"issue":"1","key":"2460_CR12","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1186\/s12886-025-03955-7","volume":"25","author":"Y Nishi","year":"2025","unstructured":"Nishi\u00a0Y, Nishi\u00a0H, Fukui\u00a0M, Tatsumichi\u00a0M, Nishi\u00a0K, Nishi\u00a0O (2025) Clinical assessment of brain adaptation following multifocal intraocular lens implantation. BMC Ophthalmol 25(1):116\u2013116","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"2460_CR13","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1177\/112067211002000112","volume":"20","author":"C Mesci","year":"2010","unstructured":"Mesci\u00a0C, Erbil\u00a0H, Ozdoker\u00a0L, Karakurt\u00a0Y, Bilge\u00a0AD (2010) Visual acuity and contrast sensitivity function after accommodative and multifocal intraocular lens implantation. Eur J Ophthalmol 20(1):90\u2013100","journal-title":"Eur J Ophthalmol"},{"issue":"11","key":"2460_CR14","doi-asserted-by":"publisher","first-page":"e1213","DOI":"10.3928\/1081597X-20250829-01","volume":"41","author":"C Abela-Formanek","year":"2025","unstructured":"Abela-Formanek\u00a0C, Amon\u00a0M, Auffarth\u00a0GU, Bostanc\u0131\u00a0B, Carones\u00a0F, Corbett\u00a0D, Ferreira\u00a0TB, Mantry\u00a0S, Saad\u00a0A, Llovet\u00a0F, Barsam\u00a0A (2025) Performance of the First Spiral Refractive Intraocular Lens for Continuous Full Range of Vision. J\u00a0Refract Surg 41(11):e1213\u2013e1222","journal-title":"J Refract Surg"},{"issue":"3","key":"2460_CR15","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1097\/APO.0000000000000296","volume":"9","author":"P Kanclerz","year":"2020","unstructured":"Kanclerz\u00a0P, Toto\u00a0F, Grzybowski\u00a0A, Alio\u00a0JL (2020) Extended Depth-of-Field Intraocular Lenses: An Update. Asia Pac J Ophthalmol (Phila) 9(3):194\u2013202","journal-title":"Asia Pac J Ophthalmol (Phila)"}],"container-title":["Die Ophthalmologie"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00347-026-02460-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00347-026-02460-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00347-026-02460-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T12:26:19Z","timestamp":1785500779000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00347-026-02460-6"}},"subtitle":["Fallbericht zu einer dysphotopsie-optimierten, nicht-diffraktiven, presbyopie-korrigierenden Intraokularlinse","Case report on a\u00a0dysphotopsia-optimized, nondiffractive, presbyopia-correcting intraocular lens"],"short-title":[],"issued":{"date-parts":[[2026,6,10]]},"references-count":15,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["2460"],"URL":"https:\/\/doi.org\/10.1007\/s00347-026-02460-6","relation":{},"ISSN":["2731-720X","2731-7218"],"issn-type":[{"value":"2731-720X","type":"print"},{"value":"2731-7218","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,10]]},"assertion":[{"value":"11 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"G.\u00a0\u0141abuz und G.U. Auffarth erkl\u00e4ren, dass eine Patentanmeldung (Nr. EP22187235) mit dem Titel \u201eLinse mit erweiterter Sch\u00e4rfentiefe durch Erzeugung einer \u00fcberm\u00e4\u00dfigen axialen chromatischen Aberration\u201c besteht, die nicht im Zusammenhang mit den Inhalten des Artikels steht. G.U.\u00a0Auffarth und T.M.\u00a0Yildirim erkl\u00e4ren, dass F\u00f6rdermittel von oder Vertr\u00e4ge mit Alcon, Johnson & Johnson, Biotech, Carl Zeiss Meditec, Contamac, Cristalens, Elios, EyeD, Eyedeal, Fluoron, Haag Streit, Hanita, Hoya Surgical, Kowa, Oculus, OphthalmoPro, Presbia, Rayner, Refocus, Santen, Stroma, Teleon und 1stQ bestehen, die nicht im Zusammenhang mit den Inhalten des Artikels stehen. G.U.\u00a0Auffarth erhielt Beratungshonorare von Alcon, Johnson & Johnson, Carl Zeiss Meditec, Elios, Hanita und Rayner, Bezahlung f\u00fcr Vortr\u00e4ge von Afidera, Alcon, Johnson & Johnson, Carl Zeiss Meditec, Elios, Eyebright, Haag Streit, Hanita, Oculus, Rayner und Teleon sowie Reisekostenunterst\u00fctzung von Alcon, Johnson & Johnson, Carl Zeiss Meditec, Hanita, Rayner und Teleon, die nicht im Zusammenhang mit den Inhalten des Artikels stehen. T.M.\u00a0Yildirim erhielt Bezahlung f\u00fcr Vortr\u00e4ge von Hoya Surgical, Alimera Science, Carl Zeiss Meditec und Johnson & Johnson und Reisekostenunterst\u00fctzung von Johnson & Johnson, die nicht im Zusammenhang mit den Inhalten des Artikels stehen. Der Hersteller des in dem Fallbericht verwendeten Intraokularlinsenimplantats, Rayner, Worthing, UK, hatte keinen Einfluss auf die Planung, Durchf\u00fchrung, Auswertung oder Verschriftlichung des Falls. E.P.\u00a0Freundt und E.\u00a0Andreas geben an, dass kein Interessenkonflikt besteht.","order":1,"name":"Ethics","label":"Interessenkonflikt","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autor\/-innen keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien. F\u00fcr Bildmaterial oder anderweitige Angaben innerhalb des Manuskripts, \u00fcber die Patient\/-innen zu identifizieren sind, liegt von ihnen und\/oder ihren gesetzlichen Vertretern\/Vertreterinnen eine schriftliche Einwilligung vor.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}}]}}