{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T02:15:12Z","timestamp":1783476912355,"version":"3.55.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2018,8,6]],"date-time":"2018-08-06T00:00:00Z","timestamp":1533513600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Heart Vessels"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1007\/s00380-018-1236-z","type":"journal-article","created":{"date-parts":[[2018,8,6]],"date-time":"2018-08-06T12:51:43Z","timestamp":1533559903000},"page":"360-367","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation for aortic stenosis using Medtronic new generation self-expanding CoreValve Evolut R"],"prefix":"10.1007","volume":"34","author":[{"given":"Hidehiro","family":"Kaneko","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Hoelschermann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Seifert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grit","family":"Tambor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maki","family":"Okamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viviane","family":"Moeller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Neuss","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Butter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,8,6]]},"reference":[{"key":"1236_CR1","doi-asserted-by":"publisher","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","volume":"363","author":"MB Leon","year":"2010","unstructured":"Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597\u20131607","journal-title":"N Engl J Med"},{"key":"1236_CR2","doi-asserted-by":"publisher","first-page":"2187","DOI":"10.1056\/NEJMoa1103510","volume":"364","author":"CR Smith","year":"2011","unstructured":"Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Williams M, Dewey T, Kapadia S, Babaliaros V, Thourani VH, Corso P, Pichard AD, Bavaria JE, Herrmann HC, Akin JJ, Anderson WN, Wang D, Pocock SJ (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364:2187\u20132198","journal-title":"N Engl J Med"},{"key":"1236_CR3","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/s00380-016-0857-3","volume":"32","author":"F Biancari","year":"2017","unstructured":"Biancari F, D\u2019Errigo P, Rosato S, Pol M, Tamburino C, Ranucci M, Seccareccia F (2017) Transcatheter aortic valve replacement in nonagenarians: early and intermediate outcome from the OBSERVANT study and meta-analysis of the literature. Heart Vessels 32:157\u2013165","journal-title":"Heart Vessels"},{"key":"1236_CR4","doi-asserted-by":"publisher","first-page":"1236","DOI":"10.1007\/s00380-017-0996-1","volume":"32","author":"R Higuchi","year":"2017","unstructured":"Higuchi R, Tobaru T, Hagiya K, Saji M, Mahara K, Takamisawa I, Shimizu J, Takanashi S, Takayama M (2017) Transcatheter aortic valve implantation in patients on corticosteroid therapy. Heart Vessels 32:1236\u20131243","journal-title":"Heart Vessels"},{"key":"1236_CR5","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1161\/CIRCULATIONAHA.109.927152","volume":"123","author":"MZ Khawaja","year":"2011","unstructured":"Khawaja MZ, Rajani R, Cook A, Khavandi A, Moynagh A, Chowdhary S, Spence MS, Brown S, Khan SQ, Walker N, Trivedi U, Hutchinson N, De Belder AJ, Moat N, Blackman DJ, Levy RD, Manoharan G, Roberts D, Khogali SS, Crean P, Brecker SJ, Baumbach A, Mullen M, Laborde JC, Hildick-Smith D (2011) Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve Collaborative). Circulation 123:951\u2013960","journal-title":"Circulation"},{"key":"1236_CR6","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1111\/j.1540-8167.2011.02211.x","volume":"23","author":"D Erkapic","year":"2012","unstructured":"Erkapic D, De Rosa S, Kelava A, Lehmann R, Fichtlscherer S, Hohnloser SH (2012) Risk for permanent pacemaker after transcatheter aortic valve implantation: a comprehensive analysis of the literature. J Cardiovasc Electrophysiol 23:391\u2013397","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1236_CR7","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1002\/ccd.23368","volume":"80","author":"H Jilaihawi","year":"2012","unstructured":"Jilaihawi H, Chakravarty T, Weiss RE, Fontana GP, Forrester J, Makkar RR (2012) Meta-analysis of complications in aortic valve replacement: comparison of Medtronic-Corevalve, Edwards-Sapien and surgical aortic valve replacement in 8,536 patients. Catheter Cardiovasc Interv 80:128\u2013138","journal-title":"Catheter Cardiovasc Interv"},{"key":"1236_CR8","doi-asserted-by":"publisher","first-page":"2281","DOI":"10.1093\/eurheartj\/eht150","volume":"34","author":"M Brignole","year":"2013","unstructured":"Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE, Zamorano JL, Achenbach S, Baumgartner H, Bax JJ, Bueno H, Dean V, Deaton C, Erol C, Fagard R, Ferrari R, Hasdai D, Hoes AW, Kirchhof P, Knuuti J, Kolh P, Lancellotti P, Linhart A, Nihoyannopoulos P, Piepoli MF, Ponikowski P, Sirnes PA, Tamargo JL, Tendera M, Torbicki A, Wijns W, Windecker S, Blomstrom-Lundqvist C, Badano LP, Aliyev F, Bansch D, Bsata W, Buser P, Charron P, Daubert JC, Dobreanu D, Faerestrand S, Le Heuzey JY, Mavrakis H, McDonagh T, Merino JL, Nawar MM, Nielsen JC, Pieske B, Poposka L, Ruschitzka F, Van Gelder IC, Wilson CM (2013) 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J 34:2281\u20132329","journal-title":"Eur Heart J"},{"key":"1236_CR9","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1016\/j.amjcard.2016.10.047","volume":"119","author":"H Kaneko","year":"2017","unstructured":"Kaneko H, Hoelschermann F, Tambor G, Yoon SH, Neuss M, Butter C (2017) Predictors of paravalvular regurgitation after transcatheter aortic valve implantation for aortic stenosis using new-generation balloon-expandable SAPIEN 3. Am J Cardiol 119:618\u2013622","journal-title":"Am J Cardiol"},{"key":"1236_CR10","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1016\/j.jcin.2013.05.008","volume":"6","author":"Y Watanabe","year":"2013","unstructured":"Watanabe Y, Morice MC, Bouvier E, Leong T, Hayashida K, Lefevre T, Hovasse T, Romano M, Chevalier B, Donzeau-Gouge P, Farge A, Cormier B, Garot P (2013) Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Interv 6:955\u2013964","journal-title":"JACC Cardiovasc Interv"},{"key":"1236_CR11","doi-asserted-by":"publisher","first-page":"1566","DOI":"10.1016\/j.amjcard.2015.08.021","volume":"116","author":"SH Yoon","year":"2015","unstructured":"Yoon SH, Ohno Y, Araki M, Barbanti M, Lin MS, Ahn JM, Yang DH, Kim YH, Imme S, Gulino S, Tamburino CI, Sgroi C, Park DW, Kang SJ, Lee SW, Lee CW, Park SW, Muramatsu T, Kao HL, Tamburino C, Park SJ (2015) Comparison of aortic root anatomy and calcification distribution between Asian and Caucasian patients who underwent transcatheter aortic valve implantation. Am J Cardiol 116:1566\u20131573","journal-title":"Am J Cardiol"},{"key":"1236_CR12","doi-asserted-by":"publisher","first-page":"1324","DOI":"10.1093\/ehjci\/jeu162","volume":"15","author":"H Jilaihawi","year":"2014","unstructured":"Jilaihawi H, Makkar RR, Kashif M, Okuyama K, Chakravarty T, Shiota T, Friede G, Nakamura M, Doctor N, Rafique A, Shibayama K, Mihara H, Trento A, Cheng W, Friedman J, Berman D, Fontana GP (2014) A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation. Eur Heart J Cardiovasc Imaging 15:1324\u20131332","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"1236_CR13","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1136\/hrt.40.8.911","volume":"40","author":"HS Friedman","year":"1978","unstructured":"Friedman HS, Zaman Q, Haft JI, Melendez S (1978) Assessment of atrioventricular conduction in aortic valve disease. Br Heart J 40:911\u2013917","journal-title":"Br Heart J"},{"key":"1236_CR14","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1161\/CIRCINTERVENTIONS.108.780858","volume":"1","author":"N Piazza","year":"2008","unstructured":"Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 1:74\u201381","journal-title":"Circ Cardiovasc Interv"},{"key":"1236_CR15","doi-asserted-by":"publisher","first-page":"1759","DOI":"10.1093\/europace\/eus191","volume":"14","author":"T Schroeter","year":"2012","unstructured":"Schroeter T, Linke A, Haensig M, Merk DR, Borger MA, Mohr FW, Schuler G (2012) Predictors of permanent pacemaker implantation after Medtronic CoreValve bioprosthesis implantation. Europace 14:1759\u20131763","journal-title":"Europace"},{"key":"1236_CR16","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.jacc.2014.04.033","volume":"64","author":"GC Siontis","year":"2014","unstructured":"Siontis GC, Juni P, Pilgrim T, Stortecky S, Bullesfeld L, Meier B, Wenaweser P, Windecker S (2014) Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. J Am Coll Cardiol 64:129\u2013140","journal-title":"J Am Coll Cardiol"},{"key":"1236_CR17","doi-asserted-by":"publisher","first-page":"2003","DOI":"10.1093\/eurheartj\/ehx785","volume":"39","author":"PJ Rosendael van","year":"2018","unstructured":"van Rosendael PJ, Delgado V, Bax JJ (2018) Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J 39:2003\u20132013","journal-title":"Eur Heart J"},{"key":"1236_CR18","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1016\/j.amjcard.2016.09.030","volume":"119","author":"J Ben-Shoshan","year":"2017","unstructured":"Ben-Shoshan J, Konigstein M, Zahler D, Margolis G, Chorin E, Steinvil A, Arbel Y, Aviram G, Granot Y, Barkagan M, Keren G, Halkin A, Banai S, Finkelstein A (2017) Comparison of the Edwards SAPIEN S3 versus Medtronic Evolut-R devices for transcatheter aortic valve implantation. Am J Cardiol 119:302\u2013307","journal-title":"Am J Cardiol"},{"key":"1236_CR19","doi-asserted-by":"publisher","first-page":"e2170","DOI":"10.4244\/EIJ-D-16-00677","volume":"12","author":"S Noble","year":"2017","unstructured":"Noble S, Stortecky S, Heg D, Tueller D, Jeger R, Toggweiler S, Ferrari E, Nietlispach F, Taramasso M, Maisano F, Grunenfelder J, Juni P, Huber C, Carrel T, Windecker S, Wenaweser P, Roffi M (2017) Comparison of procedural and clinical outcomes with Evolut R versus Medtronic CoreValve: a Swiss TAVI registry analysis. EuroIntervention 12:e2170\u2013e2176","journal-title":"EuroIntervention"},{"key":"1236_CR20","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.jcin.2016.08.050","volume":"10","author":"JJ Popma","year":"2017","unstructured":"Popma JJ, Reardon MJ, Khabbaz K, Harrison JK, Hughes GC, Kodali S, George I, Deeb GM, Chetcuti S, Kipperman R, Brown J, Qiao H, Slater J, Williams MR (2017) Early clinical outcomes after transcatheter aortic valve replacement using a novel self-expanding bioprosthesis in patients with severe aortic stenosis who are suboptimal for surgery: results of the Evolut R U.S. Study. JACC Cardiovasc Interv 10:268\u2013275","journal-title":"JACC Cardiovasc Interv"},{"key":"1236_CR21","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.1093\/europace\/eut206","volume":"15","author":"M Brignole","year":"2013","unstructured":"Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE (2013) 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace 15:1070\u20131118","journal-title":"Europace"},{"key":"1236_CR22","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1093\/europace\/euq094","volume":"12","author":"D Erkapic","year":"2010","unstructured":"Erkapic D, Kim WK, Weber M, Mollmann H, Berkowitsch A, Zaltsberg S, Pajitnev DJ, Rixe J, Neumann T, Kuniss M, Sperzel J, Hamm CW, Pitschner HF (2010) Electrocardiographic and further predictors for permanent pacemaker requirement after transcatheter aortic valve implantation. Europace 12:1188\u20131190","journal-title":"Europace"},{"key":"1236_CR23","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1002\/ccd.22563","volume":"76","author":"G Latsios","year":"2010","unstructured":"Latsios G, Gerckens U, Buellesfeld L, Mueller R, John D, Yuecel S, Syring J, Sauren B, Grube E (2010) \u201cDevice landing zone\u201d calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI. Catheter Cardiovasc Interv 76:431\u2013439","journal-title":"Catheter Cardiovasc Interv"},{"key":"1236_CR24","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1016\/j.jcin.2010.01.017","volume":"3","author":"S Bleiziffer","year":"2010","unstructured":"Bleiziffer S, Ruge H, Horer J, Hutter A, Geisbusch S, Brockmann G, Mazzitelli D, Bauernschmitt R, Lange R (2010) Predictors for new-onset complete heart block after transcatheter aortic valve implantation. JACC Cardiovasc Interv 3:524\u2013530","journal-title":"JACC Cardiovasc Interv"},{"key":"1236_CR25","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1056\/NEJMoa1514616","volume":"374","author":"MB Leon","year":"2016","unstructured":"Leon MB, Smith CR, Mack MJ, Makkar RR, Svensson LG, Kodali SK, Thourani VH, Tuzcu EM, Miller DC, Herrmann HC, Doshi D, Cohen DJ, Pichard AD, Kapadia S, Dewey T, Babaliaros V, Szeto WY, Williams MR, Kereiakes D, Zajarias A, Greason KL, Whisenant BK, Hodson RW, Moses JW, Trento A, Brown DL, Fearon WF, Pibarot P, Hahn RT, Jaber WA, Anderson WN, Alu MC, Webb JG (2016) Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med 374:1609\u20131620","journal-title":"N Engl J Med"},{"key":"1236_CR26","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1056\/NEJMoa1700456","volume":"376","author":"MJ Reardon","year":"2017","unstructured":"Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Sondergaard L, Mumtaz M, Adams DH, Deeb GM, Maini B, Gada H, Chetcuti S, Gleason T, Heiser J, Lange R, Merhi W, Oh JK, Olsen PS, Piazza N, Williams M, Windecker S, Yakubov SJ, Grube E, Makkar R, Lee JS, Conte J, Vang E, Nguyen H, Chang Y, Mugglin AS, Serruys PW, Kappetein AP (2017) Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med 376:1321\u20131331","journal-title":"N Engl J Med"},{"key":"1236_CR27","doi-asserted-by":"publisher","first-page":"35","DOI":"10.7326\/0003-4819-158-1-201301010-00007","volume":"158","author":"PJ Khatri","year":"2013","unstructured":"Khatri PJ, Webb JG, Rodes-Cabau J, Fremes SE, Ruel M, Lau K, Guo H, Wijeysundera HC, Ko DT (2013) Adverse effects associated with transcatheter aortic valve implantation: a meta-analysis of contemporary studies. Ann Intern Med 158:35\u201346","journal-title":"Ann Intern Med"},{"key":"1236_CR28","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/j.acvd.2013.01.006","volume":"106","author":"K Chevreul","year":"2013","unstructured":"Chevreul K, Brunn M, Cadier B, Haour G, Eltchaninoff H, Prat A, Leguerrier A, Blanchard D, Fournial G, Iung B, Donzeau-Gouge P, Tribouilloy C, Debrux JL, Pavie A, Gilard M, Gueret P (2013) Cost of transcatheter aortic valve implantation and factors associated with higher hospital stay cost in patients of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Arch Cardiovasc Dis 106:209\u2013219","journal-title":"Arch Cardiovasc Dis"},{"key":"1236_CR29","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.jcin.2014.07.022","volume":"8","author":"TM Nazif","year":"2015","unstructured":"Nazif TM, Dizon JM, Hahn RT, Xu K, Babaliaros V, Douglas PS, El-Chami MF, Herrmann HC, Mack M, Makkar RR, Miller DC, Pichard A, Tuzcu EM, Szeto WY, Webb JG, Moses JW, Smith CR, Williams MR, Leon MB, Kodali SK (2015) Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry. JACC Cardiovasc Interv 8:60\u201369","journal-title":"JACC Cardiovasc Interv"},{"key":"1236_CR30","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1111\/joic.12356","volume":"30","author":"B Gomes","year":"2017","unstructured":"Gomes B, Geis NA, Chorianopoulos E, Meder B, Leuschner F, Katus HA, Bekeredjian R (2017) Improvements of procedural results with a new-generation self-expanding transfemoral aortic valve prosthesis in comparison to the old-generation device. J Interv Cardiol 30:72\u201378","journal-title":"J Interv Cardiol"}],"container-title":["Heart and Vessels"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00380-018-1236-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00380-018-1236-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00380-018-1236-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,27]],"date-time":"2019-08-27T22:07:25Z","timestamp":1566943645000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00380-018-1236-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,6]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["1236"],"URL":"https:\/\/doi.org\/10.1007\/s00380-018-1236-z","relation":{},"ISSN":["0910-8327","1615-2573"],"issn-type":[{"value":"0910-8327","type":"print"},{"value":"1615-2573","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,6]]},"assertion":[{"value":"11 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 July 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"We have no conflict of interest for this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}