{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T22:54:56Z","timestamp":1784156096488,"version":"3.55.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T00:00:00Z","timestamp":1559088000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T00:00:00Z","timestamp":1559088000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Heart Vessels"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1007\/s00380-019-01442-w","type":"journal-article","created":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T17:04:24Z","timestamp":1559149464000},"page":"1984-1992","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Network meta-analysis of new-generation valves for transcatheter aortic valve implantation"],"prefix":"10.1007","volume":"34","author":[{"name":"ALICE (All-Literature Investigation of Cardiovascular Evidence) Group","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hisato","family":"Takagi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yosuke","family":"Hari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kouki","family":"Nakashima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiki","family":"Kuno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomo","family":"Ando","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,5,29]]},"reference":[{"key":"1442_CR1","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.carrev.2017.07.006","volume":"19","author":"T Ando","year":"2018","unstructured":"Ando T, Takagi H, Telila T, Afonso L (2018) Comparison of outcomes in new-generation versus early-generation heart valve in transcatheter aortic valve implantation: a systematic review and meta-analysis. Cardiovasc Revasc Med 19:186\u2013191","journal-title":"Cardiovasc Revasc Med"},{"key":"1442_CR2","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1016\/j.amjcard.2018.02.004","volume":"121","author":"M Akodad","year":"2018","unstructured":"Akodad M, Lattuca B, Agullo A, Macia JC, Gandet T, Marin G, Iemmi A, Vernhet H, Schmutz L, Nagot N, Albat B, Cayla G, Leclercq F (2018) Prognostic impact of calcium score after transcatheter aortic valve implantation performed with new generation prosthesis. Am J Cardiol 121:1225\u20131230","journal-title":"Am J Cardiol"},{"key":"1442_CR3","doi-asserted-by":"publisher","first-page":"2557","DOI":"10.1161\/CIRCULATIONAHA.118.034129","volume":"137","author":"FM Asch","year":"2018","unstructured":"Asch FM, Vannan MA, Singh S, Khandheria B, Little SH, Allocco DJ, Meredith IT, Feldman TE, Reardon MJ, Weissman NJ (2018) Hemodynamic and echocardiographic comparison of the lotus and corevalve transcatheter aortic valves in patients with high and extreme surgical risk: an analysis from the reprise iii randomized controlled trial. Circulation 137:2557\u20132567","journal-title":"Circulation"},{"key":"1442_CR4","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1002\/ccd.27588","volume":"5","author":"A Eitan","year":"2018","unstructured":"Eitan A, Witt J, Stripling J, Haselbach T, Rie\u00df FC, Schofer J (2018) Performance of the Evolut-R 34 mm versus Sapien-3 29 mm in Transcatheter aortic valve replacement patients with larger annuli: Early outcome results of Evolut-R 34 mm as compared with Sapien-3 29 mm in patients with Annuli \u226526 mm. Catheter Cardiovasc Interv 5:5. \nhttps:\/\/doi.org\/10.1002\/ccd.27588","journal-title":"Catheter Cardiovasc Interv"},{"key":"1442_CR5","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1016\/j.recesp.2017.10.032","volume":"71","author":"E Enr\u00edquez-Rodr\u00edguez","year":"2018","unstructured":"Enr\u00edquez-Rodr\u00edguez E, Amat-Santos IJ, Jim\u00e9nez-Quevedo P, Mart\u00edn-Morquecho I, Tirado-Conte G, P\u00e9rez-Vizcayno MJ, G\u00f3mez de Diego JJ, Arnold R, Aldaz\u00e1bal A, Rojas P, de Agust\u00edn A, Del Trigo M, Guti\u00e9rrez H, San Rom\u00e1n JA, Macaya C, Nombela-Franco L (2018) Comparison of the hemodynamic performance of the balloon-expandable SAPIEN 3 versus self-expandable evolut R transcatheter valve: a case-matched study. Rev Esp Cardiol (Engl Ed) 71:735\u2013742","journal-title":"Rev Esp Cardiol (Engl Ed)"},{"key":"1442_CR6","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ijcard.2017.05.095","volume":"243","author":"C Giannini","year":"2017","unstructured":"Giannini C, De Carlo M, Tamburino C, Ettori F, Latib AM, Bedogni F, Bruschi G, Presbitero P, Poli A, Fabbiocchi F, Violini R, Trani C, Giudice P, Barbanti M, Adamo M, Colombo P, Benincasa S, Agnifili M, Petronio AS (2017) Transcathether aortic valve implantation with the new repositionable self-expandable Evolut R versus CoreValve system: a case-matched comparison. Int J Cardiol 243:126\u2013131","journal-title":"Int J Cardiol"},{"key":"1442_CR7","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1111\/joic.12356","volume":"30","author":"B Gomes","year":"2017","unstructured":"Gomes B, Geis NA, Chorianopoulos E, Meder B, Leuschner F, Katus HA, Bekeredjian R (2017) Improvements of procedural results with a new-generation self-expanding transfemoral aortic valve prosthesis in comparison to the old-generation device. J Interv Cardiol 30:72\u201378","journal-title":"J Interv Cardiol"},{"key":"1442_CR8","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1016\/j.jjcc.2016.08.008","volume":"69","author":"B Gonska","year":"2017","unstructured":"Gonska B, Seeger J, Baarts J, Rodewald C, Scharnbeck D, Rottbauer W, W\u00f6hrle J (2017) The balloon-expandable Edwards Sapien 3 valve is superior to the self-expanding Medtronic CoreValve in patients with severe aortic stenosis undergoing transfemoral aortic valve implantation. J Cardiol 69:877\u2013882","journal-title":"J Cardiol"},{"key":"1442_CR9","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1016\/j.jcin.2015.03.014","volume":"8","author":"RP Gooley","year":"2015","unstructured":"Gooley RP, Talman AH, Cameron JD, Lockwood SM, Meredith IT (2015) Comparison of self-expanding and mechanically expanded transcatheter aortic valve prostheses. JACC Cardiovasc Interv 8:962\u2013971","journal-title":"JACC Cardiovasc Interv"},{"key":"1442_CR10","doi-asserted-by":"publisher","first-page":"2078","DOI":"10.1016\/j.jcin.2017.06.026","volume":"10","author":"O Husser","year":"2017","unstructured":"Husser O, Kim WK, Pellegrini C, Holzamer A, Walther T, Mayr PN, Joner M, Kasel AM, Trenkwalder T, Michel J, Rheude T, Kastrati A, Schunkert H, Burgdorf C, Hilker M, M\u00f6llmann H, Hengstenberg C (2017) Multicenter comparison of novel self-expanding versus balloon-expandable transcatheter heart valves. JACC Cardiovasc Interv 10:2078\u20132087","journal-title":"JACC Cardiovasc Interv"},{"key":"1442_CR11","first-page":"30","volume":"29","author":"KU Jarr","year":"2017","unstructured":"Jarr KU, Leuschner F, Meder B, Katus HA, Bekeredjian R, Chorianopoulos E (2017) Initial single-center experience with the fully repositionable transfemoral lotus aortic valve system. J Invasive Cardiol 29:30\u201335","journal-title":"J Invasive Cardiol"},{"key":"1442_CR12","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1002\/ccd.26837","volume":"90","author":"T Jatene","year":"2017","unstructured":"Jatene T, Castro-Filho A, Meneguz-Moreno RA, Siqueira DA, Abizaid AAC, Ramos AIO, Arrais M, Le Bihan DCS, Barretto RBM, Moreira AC, Sousa AGMR, Eduardo Sousa J (2017) Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis. Catheter Cardiovasc Interv 90:139\u2013146","journal-title":"Catheter Cardiovasc Interv"},{"key":"1442_CR13","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1002\/ccd.27862","volume":"5","author":"K Kalogeras","year":"2018","unstructured":"Kalogeras K, Kabir T, Mittal T, Mirsadraee S, Skondras E, Rahman Haley S, Zuhair M, Vavuranakis M, Tousoulis D, Dalby M, Panoulas V (2018) Real-world comparison of the new 34 mm self-expandable transcatheter aortic prosthesis Evolut R to its 31 mm core valve predecessor. Catheter Cardiovasc Interv 5:5. \nhttps:\/\/doi.org\/10.1002\/ccd.27862","journal-title":"Catheter Cardiovasc Interv"},{"key":"1442_CR14","first-page":"69","volume":"29","author":"U Landes","year":"2017","unstructured":"Landes U, Bental T, Barsheshet A, Assali A, Vaknin Assa H, Levi A, Orvin K, Kornowski R (2017) Comparative matched outcome of Evolut-R vs CoreValve transcatheter aortic valve implantation. J Invasive Cardiol 29:69\u201374","journal-title":"J Invasive Cardiol"},{"key":"1442_CR15","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1161\/CIRCINTERVENTIONS.117.005013","volume":"10","author":"V Mauri","year":"2017","unstructured":"Mauri V, Kim WK, Abumayyaleh M, Walther T, Moellmann H, Schaefer U, Conradi L, Hengstenberg C, Hilker M, Wahlers T, Baldus S, Rudolph V, Madershahian N, Rudolph TK (2017) Short-term outcome and hemodynamic performance of next-generation self-expanding versus balloon-expandable transcatheter aortic valves in patients with small aortic annulus: a multicenter propensity-matched comparison. Circ Cardiovasc Interv 10:10","journal-title":"Circ Cardiovasc Interv"},{"key":"1442_CR16","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1111\/joic.12512","volume":"31","author":"TA Musa","year":"2018","unstructured":"Musa TA, Uddin A, Dobson LE, Swoboda PP, Garg P, Foley JRJ, Malkin C, Plein S, Blackman DJ, Greenwood JP (2018) Cardiovascular magnetic resonance assessment of 1st generation CoreValve and 2nd generation Lotus valves. J Interv Cardiol 31:391\u2013399","journal-title":"J Interv Cardiol"},{"key":"1442_CR17","doi-asserted-by":"publisher","first-page":"655","DOI":"10.2459\/JCM.0000000000000705","volume":"19","author":"L Nai Fovino","year":"2018","unstructured":"Nai Fovino L, Badawy MRA, Fraccaro C, D'Onofrio A, Purita PAM, Frigo AC, Tellaroli P, Mauro A, Tusa M, Napodano M, Gerosa G, Iliceto S, Bedogni F, AbdelRheim AER, Tarantini G (2018) Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve. J Cardiovasc Med (Hagerstown) 19:655\u2013663","journal-title":"J Cardiovasc Med (Hagerstown)"},{"key":"1442_CR18","doi-asserted-by":"publisher","first-page":"e2170","DOI":"10.4244\/EIJ-D-16-00677","volume":"12","author":"S Noble","year":"2017","unstructured":"Noble S, Stortecky S, Heg D, Tueller D, Jeger R, Toggweiler S, Ferrari E, Nietlispach F, Taramasso M, Maisano F, Gr\u00fcnenfelder J, J\u00fcni P, Huber C, Carrel T, Windecker S, Wenaweser P, Roffi M (2017) Comparison of procedural and clinical outcomes with Evolut R versus Medtronic CoreValve: a Swiss TAVI registry analysis. EuroIntervention 12:e2170\u2013e2176","journal-title":"EuroIntervention"},{"key":"1442_CR19","doi-asserted-by":"publisher","first-page":"e000770","DOI":"10.1136\/openhrt-2017-000770","volume":"5","author":"N Perrin","year":"2018","unstructured":"Perrin N, Perrin T, Hachulla AL, Frei A, M\u00fcller H, Roffi M, Cikirikcioglu M, Ellenberger C, Licker MJ, Burri H, Noble S (2018) Conduction disorders using the Evolut R prosthesis compared with the CoreValve: has anything changed? Open Heart 5:e000770","journal-title":"Open Heart"},{"key":"1442_CR20","doi-asserted-by":"publisher","first-page":"e004088","DOI":"10.1161\/JAHA.116.004088","volume":"5","author":"T Pilgrim","year":"2016","unstructured":"Pilgrim T, Stortecky S, Nietlispach F, Heg D, Tueller D, Toggweiler S, Ferrari E, Noble S, Maisano F, Jeger R, Roffi M, Gr\u00fcnenfelder J, Huber C, Wenaweser P, Windecker S (2016) Repositionable versus balloon-expandable devices for transcatheter aortic valve implantation in patients with aortic stenosis. J Am Heart Assoc 5:e004088","journal-title":"J Am Heart Assoc"},{"key":"1442_CR21","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1016\/j.jcin.2018.04.016","volume":"11","author":"J Rod\u00e9s-Cabau","year":"2018","unstructured":"Rod\u00e9s-Cabau J, Urena M, Nombela-Franco L, Amat-Santos I, Kleiman N, Munoz-Garcia A, Atienza F, Serra V, Deyell MW, Veiga-Fernandez G, Masson JB, Canadas-Godoy V, Himbert D, Castrodeza J, Elizaga J, Francisco Pascual J, Webb JG, de la Torre JM, Asmarats L, Pelletier-Beaumont E, Philippon F (2018) Arrhythmic burden as determined by ambulatory continuous cardiac monitoring in patients with new-onset persistent left bundle branch block following transcatheter aortic valve replacement: The MARE study. JACC Cardiovasc Interv 11:1495\u20131505","journal-title":"JACC Cardiovasc Interv"},{"key":"1442_CR22","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.ijcard.2016.04.023","volume":"216","author":"R Rodr\u00edguez-Olivares","year":"2016","unstructured":"Rodr\u00edguez-Olivares R, van Gils L, El Faquir N, Rahhab Z, Di Martino LF, van Weenen S, de Vries J, Galema TW, Geleijnse ML, Budde RP, Boersma E, de Jaegere PP, Van Mieghem NM (2016) Importance of the left ventricular outflow tract in the need for pacemaker implantation after transcatheter aortic valve replacement. Int J Cardiol 216:9\u201315","journal-title":"Int J Cardiol"},{"key":"1442_CR23","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1111\/joic.12389","volume":"30","author":"T Rogers","year":"2017","unstructured":"Rogers T, Steinvil A, Buchanan K, Alraies MC, Koifman E, Gai J, Torguson R, Okubagzi P, Ben-Dor I, Pichard A, Satler L, Waksman R (2017) Contemporary transcatheter aortic valve replacement with third-generation balloon-expandable versus self-expanding devices. J Interv Cardiol 30:356\u2013361","journal-title":"J Interv Cardiol"},{"key":"1442_CR24","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1016\/j.jjcc.2017.09.014","volume":"71","author":"N Schofer","year":"2018","unstructured":"Schofer N, Deuschl F, Sch\u00f6n G, Seiffert M, Linder M, Schaefer A, Schirmer J, Lubos E, Reichenspurner H, Blankenberg S, Conradi L, Sch\u00e4fer U (2018) Comparative analysis of balloon-versus mechanically-expandable transcatheter heart valves considering landing zone calcification. J Cardiol 71:540\u2013546","journal-title":"J Cardiol"},{"key":"1442_CR25","first-page":"52","volume":"12","author":"E Schulz","year":"2016","unstructured":"Schulz E, Jabs A, Gori T, von Bardeleben S, Hink U, Kasper-K\u00f6nig W, Vahl CF, M\u00fcnzel T (2016) Transcatheter aortic valve implantation with the new-generation Evolut R\u2122: comparison with CoreValve\u00ae in a single center cohort. Int J Cardiol Heart Vasc 12:52\u201356","journal-title":"Int J Cardiol Heart Vasc"},{"key":"1442_CR26","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1161\/CIRCINTERVENTIONS.116.004670","volume":"10","author":"J Seeger","year":"2017","unstructured":"Seeger J, Gonska B, Rottbauer W, W\u00f6hrle J (2017) Outcome with the repositionable and retrievable boston scientific lotus valve compared with the balloon-expandable Edwards Sapien 3 valve in patients undergoing transfemoral aortic valve replacement. Circ Cardiovasc Interv 10:10","journal-title":"Circ Cardiovasc Interv"},{"key":"1442_CR27","doi-asserted-by":"publisher","first-page":"2090","DOI":"10.1016\/j.jcin.2017.07.027","volume":"10","author":"P Sorajja","year":"2017","unstructured":"Sorajja P, Kodali S, Reardon MJ, Szeto WY, Chetcuti SJ, Hermiller J Jr, Chenoweth S, Adams DH, Popma JJ (2017) Outcomes for the commercial use of self-expanding prostheses in transcatheter aortic valve replacement: a report from the STS\/ACC TVT registry. JACC Cardiovasc Interv 10:2090\u20132098","journal-title":"JACC Cardiovasc Interv"},{"key":"1442_CR28","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1111\/imj.12938","volume":"46","author":"V Subban","year":"2016","unstructured":"Subban V, Murdoch D, Savage ML, Crowhurst J, Saireddy R, Poon KK, Incani A, Bett N, Burstow DJ, Scalia GM, Clarke A, Raffel OC, Aroney CN, Walters DL (2016) Outcomes of transcatheter aortic valve implantation in high surgical risk and inoperable patients with aortic stenosis: a single Australian Centre experience. Intern Med J 46:42\u201351","journal-title":"Intern Med J"},{"key":"1442_CR29","doi-asserted-by":"crossref","first-page":"e005028","DOI":"10.1161\/JAHA.116.005028","volume":"6","author":"L van Gils","year":"2017","unstructured":"van Gils L, Tchetche D, Lhermusier T, Abawi M, Dumonteil N, Rodriguez Olivares R, Molina-Martin de Nicolas J, Stella PR, Carri\u00e9 D, De Jaegere PP, Van Mieghem NM (2017) Transcatheter heart valve selection and permanent pacemaker implantation in patients with pre-existent right bundle branch block. J Am Heart Assoc 6:e005028","journal-title":"J Am Heart Assoc"},{"key":"1442_CR30","first-page":"405","volume":"26","author":"V Veulemans","year":"2017","unstructured":"Veulemans V, S\u00f6temann DB, Kleinebrecht L, Keymel S, Jung C, Zeus T, Kelm M, Westenfeld R (2017) Transcatheter aortic valve implantation in high-risk\/inoperable patients: repositionable versus non-repositionable self-expanding valve. J Heart Valve Dis 26:405\u2013412","journal-title":"J Heart Valve Dis"},{"key":"1442_CR31","doi-asserted-by":"publisher","first-page":"e76654","DOI":"10.1371\/journal.pone.0076654","volume":"8","author":"A Chaimani","year":"2013","unstructured":"Chaimani A, Higgins JP, Mavridis D, Spyridonos P, Salanti G (2013) Graphical tools for network meta-analysis in STATA. PLoS ONE 8:e76654","journal-title":"PLoS ONE"},{"key":"1442_CR32","unstructured":"Higgins JPT, Deeks JJ, Altman DG (eds) (2011) Chapter 16: Special topics in statistics. In: Higgins JPT, Green S (eds) Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0 (updated March 2011). The Cochrane Collaboration. \nhttps:\/\/www.cochrane-handbook.org\n\n. Accessed 1 Nov 2018"},{"key":"1442_CR33","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.4244\/EIJV11I9A211","volume":"11","author":"G Athappan","year":"2016","unstructured":"Athappan G, Gajulapalli RD, Tuzcu ME, Svensson LG, Kapadia SR (2016) A systematic review on the safety of second-generation transcatheter aortic valves. EuroIntervention 11:1034\u20131043","journal-title":"EuroIntervention"},{"key":"1442_CR34","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.ijcard.2017.07.083","volume":"245","author":"M Barbanti","year":"2017","unstructured":"Barbanti M, Buccheri S, Rod\u00e9s-Cabau J, Gulino S, G\u00e9n\u00e9reux P, Pilato G, Dvir D, Picci A, Costa G, Tamburino C, Leon MB, Webb JG (2017) Transcatheter aortic valve replacement with new-generation devices: a systematic review and meta-analysis. Int J Cardiol 245:83\u201389","journal-title":"Int J Cardiol"},{"key":"1442_CR35","doi-asserted-by":"publisher","first-page":"2003","DOI":"10.1093\/eurheartj\/ehx785","volume":"39","author":"PJ van Rosendael","year":"2018","unstructured":"van Rosendael PJ, Delgado V, Bax JJ (2018) Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J 39:2003\u20132013","journal-title":"Eur Heart J"},{"issue":"Suppl Q","key":"1442_CR36","doi-asserted-by":"publisher","first-page":"Q70","DOI":"10.4244\/EIJV8SQA12","volume":"8","author":"IT Meredith","year":"2012","unstructured":"Meredith IT, Hood KL, Haratani N, Allocco DJ, Dawkins KD (2012) Boston Scientific Lotus valve. EuroIntervention 8(Suppl Q):Q70\u2013Q74","journal-title":"EuroIntervention"}],"container-title":["Heart and Vessels"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00380-019-01442-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00380-019-01442-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00380-019-01442-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,27]],"date-time":"2020-05-27T23:27:15Z","timestamp":1590622035000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00380-019-01442-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,29]]},"references-count":36,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1442"],"URL":"https:\/\/doi.org\/10.1007\/s00380-019-01442-w","relation":{},"ISSN":["0910-8327","1615-2573"],"issn-type":[{"value":"0910-8327","type":"print"},{"value":"1615-2573","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,29]]},"assertion":[{"value":"8 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"None of the authors declare any potential conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The present study is a meta-analysis of published articles, and neither a human nor animal study that should be approved by the appropriate ethics committee and performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Research involving human participants and\/or animals"}},{"value":"The present study is a meta-analysis of published articles, and accordingly, there are no persons who gave their informed consent prior to their inclusion in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}