{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T22:26:15Z","timestamp":1776896775000,"version":"3.51.2"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T00:00:00Z","timestamp":1580774400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T00:00:00Z","timestamp":1580774400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Childs Nerv Syst"],"published-print":{"date-parts":[[2020,9]]},"DOI":"10.1007\/s00381-020-04520-x","type":"journal-article","created":{"date-parts":[[2020,2,4]],"date-time":"2020-02-04T10:03:06Z","timestamp":1580810586000},"page":"2021-2025","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Management of paediatric hydrocephalous with Miethke fixed pressure gravitational valves. The Alder Hey Children\u2019s Hospital experience"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0901-1366","authenticated-orcid":false,"given":"Giannis","family":"Sokratous","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Hadfield","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Libby","family":"Van Tonder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dawn","family":"Hennigan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Ellenbogen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benedetta","family":"Pettorini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Conor","family":"Mallucci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,2,4]]},"reference":[{"key":"4520_CR1","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/1743-8454-3-9","volume":"3","author":"DM Allin","year":"2006","unstructured":"Allin DM, Czosnyka ZH, Czosnyka M et al (2006) In vitro hydrodynamic properties of the Miethke ProGAV hydrocephalus shunt. Cerebrospinal Fluid Res 3:9","journal-title":"Cerebrospinal Fluid Res"},{"key":"4520_CR2","first-page":"103","volume-title":"The solved and unsolved problems of hydrocephalus valves: a critical comment","author":"A Aschoff","year":"1993","unstructured":"Aschoff A, Benesch C, Kremer P et al (1993) The solved and unsolved problems of hydrocephalus valves: a critical comment. Anonymous Intracerebral Hemorrhage Hydrocephalus Malresorptivus Peripheral Nerves Springer, In, pp 103\u2013114"},{"key":"4520_CR3","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1055\/s-2003-40372","volume":"64","author":"C Cedzich","year":"2003","unstructured":"Cedzich C, Wiessner A (2003) The treatment of hydrocephalus in infants and children using hydrostatic valves. Zentralbl Neurochir 64:51\u201357","journal-title":"Zentralbl Neurochir"},{"key":"4520_CR4","unstructured":"Drake JM, Kestle J (1996) Rationale and methodology of the multicenter pediatric cerebrospinal sluid shunt design trial. Child\u2019s Nervous System 12(8):434\u2013447"},{"key":"4520_CR5","first-page":"179","volume":"106","author":"R Eymann","year":"2007","unstructured":"Eymann R, Steudel W, Kiefer M (2007) Pediatric gravitational shunts: initial results from a prospective study. J Neurosurg 106:179\u2013184","journal-title":"J Neurosurg"},{"key":"4520_CR6","doi-asserted-by":"publisher","first-page":"288","DOI":"10.3171\/2009.4.PEDS08204","volume":"4","author":"EJ Haberl","year":"2009","unstructured":"Haberl EJ, Messing-Juenger M, Schuhmann M et al (2009) Experiences with a gravity-assisted valve in hydrocephalic children. J Neurosurg Pediatr 4:288\u2013293","journal-title":"J Neurosurg Pediatr"},{"key":"4520_CR7","doi-asserted-by":"publisher","first-page":"52","DOI":"10.3171\/jns.2003.99.1.0052","volume":"99","author":"PW Hanlo","year":"2003","unstructured":"Hanlo PW, Cinalli G, Vandertop WP, Faber JA, B\u00f8geskov L, B\u00f8rgesen SE, Boschert J, Chumas P, Eder H, Pople IK, Serlo W, Vitzthum E (2003) Treatment of hydrocephalus determined by the european orbis sigma valve II survey: a multicenter prospective 5-year shunt survival study in children and adults in whom a flow-regulating shunt was used. J Neurosurg 99:52\u201357","journal-title":"J Neurosurg"},{"key":"4520_CR8","doi-asserted-by":"publisher","first-page":"141","DOI":"10.3171\/jns.2005.102.2.0141","volume":"102","author":"JR Kestle","year":"2005","unstructured":"Kestle JR, Walker ML (2005) A multicenter prospective cohort study of the strata valve for the management of hydrocephalus in pediatric patients. J Neurosurg 102:141\u2013145","journal-title":"J Neurosurg"},{"key":"4520_CR9","doi-asserted-by":"publisher","first-page":"22","DOI":"10.3171\/2011.4.PEDS10551","volume":"8","author":"JR Kestle","year":"2011","unstructured":"Kestle JR, Riva-Cambrin J, Wellons JC et al (2011) A standardized protocol to reduce cerebrospinal fluid shunt infection: the hydrocephalus clinical research network quality improvement initiative. J Neurosurg Pediatr 8:22\u201329","journal-title":"J Neurosurg Pediatr"},{"key":"4520_CR10","doi-asserted-by":"publisher","first-page":"334","DOI":"10.3171\/2013.7.PEDS12637","volume":"12","author":"AV Kulkarni","year":"2013","unstructured":"Kulkarni AV, Riva-Cambrin J, Butler J et al (2013) Outcomes of CSF shunting in children: comparison of hydrocephalus clinical research network cohort with historical controls. J Neurosurg Pediatr 12:334\u2013338","journal-title":"J Neurosurg Pediatr"},{"key":"4520_CR11","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1136\/jnnp-2012-303936","volume":"84","author":"J Lemcke","year":"2013","unstructured":"Lemcke J, Meier U, Muller C et al (2013) Safety and efficacy of gravitational shunt valves in patients with idiopathic normal pressure hydrocephalus: a pragmatic, randomised, open label, multicentre trial (SVASONA). J Neurol Neurosurg Psychiatry 84:850\u2013857","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"4520_CR12","doi-asserted-by":"publisher","first-page":"S38","DOI":"10.4103\/2152-7806.109197","volume":"4","author":"BR Lutz","year":"2013","unstructured":"Lutz BR, Venkataraman P, Browd SR (2013) New and improved ways to treat hydrocephalus: pursuit of a smart shunt. Surg Neurol Int 4:S38\u2013S50","journal-title":"Surg Neurol Int"},{"key":"4520_CR13","doi-asserted-by":"crossref","unstructured":"Meier U, Lemcke J, Al-Zain F (2007) Clinical experience in the treatment of idiopathic normal-pressure hydrocephalus using the programmable gravity-assisted valve (ProGAVAesculap). 17:52\u201355","DOI":"10.1097\/WNQ.0b013e3180331759"},{"key":"4520_CR14","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1159\/000084859","volume":"41","author":"TR Meling","year":"2005","unstructured":"Meling TR, Egge A, Due-Tonnessen B (2005) The gravity-assisted paedi-gav valve in the treatment of pediatric hydrocephalus. Pediatr Neurosurg 41:8\u201314","journal-title":"Pediatr Neurosurg"},{"key":"4520_CR15","doi-asserted-by":"crossref","unstructured":"Miethke C, Affeld K (1994) A new valve for the treatment of hydrocephalus-ein neues ventil zur behandlung des hydrocephalus. 39:181\u2013187","DOI":"10.1515\/bmte.1994.39.7-8.181"},{"key":"4520_CR16","doi-asserted-by":"publisher","first-page":"1399","DOI":"10.1097\/00006123-199912000-00026","volume":"45","author":"IF Pollack","year":"1999","unstructured":"Pollack IF, Albright AL, Adelson PD (1999) A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus. Neurosurgery 45:1399\u20131411","journal-title":"Neurosurgery"},{"key":"4520_CR17","doi-asserted-by":"publisher","first-page":"473","DOI":"10.3171\/2012.1.PEDS11292","volume":"9","author":"J Riva-Cambrin","year":"2012","unstructured":"Riva-Cambrin J, Shannon CN, Holubkov R et al (2012) Center effect and other factors influencing temporization and shunting of cerebrospinal fluid in preterm infants with intraventricular hemorrhage. J Neurosurg Pediatr 9:473\u2013481","journal-title":"J Neurosurg Pediatr"},{"key":"4520_CR18","doi-asserted-by":"publisher","first-page":"90","DOI":"10.3171\/2008.11.PEDS08154","volume":"3","author":"V Rohde","year":"2009","unstructured":"Rohde V, Haberl E, Ludwig H et al (2009) First experiences with an adjustable gravitational valve in childhood hydrocephalus. J Neurosurg Pediatr 3:90\u201393","journal-title":"J Neurosurg Pediatr"},{"key":"4520_CR19","first-page":"119","volume":"103","author":"S Sood","year":"2005","unstructured":"Sood S, Barrett RJ, Powell T et al (2005) The role of lumbar shunts in the management of slit ventricles: does the slit-ventricle syndrome exist? J Neurosurg 103:119\u2013123","journal-title":"J Neurosurg"},{"key":"4520_CR20","doi-asserted-by":"publisher","first-page":"S37","DOI":"10.1186\/1743-8454-2-S1-S37","volume":"2","author":"C Sprung","year":"2005","unstructured":"Sprung C, Schlosser H, Brock M (2005) Shunting of hydrocephalus with the new adjustable gravitational proGAV\u2013advantages compared to other devices. Cerebrospinal Fluid Res 2:S37","journal-title":"Cerebrospinal Fluid Res"},{"key":"4520_CR21","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1227\/01.NEU.0000365272.77634.6B","volume":"66","author":"C Sprung","year":"2010","unstructured":"Sprung C, Schlosser H, Lemcke J, Meier U, Messing-J\u00fcnger M, Trost HA, Weber F, Schul C, Rohde V, Ludwig HC, H\u00f6pfner J, Sepehrnia A, Mirzayan MJ, Krauss JK (2010) The adjustable proGAV shunt: a prospective safety and reliability multicenter study. Neurosurgery 66:465\u2013474","journal-title":"Neurosurgery"},{"key":"4520_CR22","doi-asserted-by":"publisher","first-page":"40","DOI":"10.3171\/PED-08\/01\/040","volume":"1","author":"SC Stein","year":"2008","unstructured":"Stein SC, Guo W (2008) Have we made progress in preventing shunt failure? A critical analysis. J Neurosurg Pediatr 1:40\u201347","journal-title":"J Neurosurg Pediatr"},{"key":"4520_CR23","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1007\/s00381-012-1956-9","volume":"29","author":"U Thomale","year":"2013","unstructured":"Thomale U, Gebert AF, Haberl H et al (2013) Shunt survival rates by using the adjustable differential pressure valve combined with a gravitational unit (proGAV) in pediatric neurosurgery. Childs Nerv Syst 29:425\u2013431","journal-title":"Childs Nerv Syst"},{"key":"4520_CR24","doi-asserted-by":"publisher","first-page":"ons245","DOI":"10.1227\/NEU.0b013e318208f5e0","volume":"68","author":"AK Toma","year":"2011","unstructured":"Toma AK, Tarnaris A, Kitchen ND et al (2011) Use of the proGAV shunt valve in normal-pressure hydrocephalus. Neurosurgery 68:ons245\u2013ons249","journal-title":"Neurosurgery"},{"key":"4520_CR25","doi-asserted-by":"publisher","first-page":"31","DOI":"10.3171\/jns.2000.92.1.0031","volume":"92","author":"S Tuli","year":"2000","unstructured":"Tuli S, Drake J, Lawless J, Wigg M, Lamberti-Pasculli M (2000) Risk factors for repeated cerebrospinal shunt failures in pediatric patients with hydrocephalus. J Neurosurg 92:31\u201338","journal-title":"J Neurosurg"},{"key":"4520_CR26","doi-asserted-by":"publisher","first-page":"471","DOI":"10.3171\/jns.2003.98.3.0471","volume":"98","author":"G Zemack","year":"2003","unstructured":"Zemack G, Bellner J, Siesj\u00f6 P, Str\u00f6mblad LG, Romner B (2003) Clinical experience with the use of a shunt with an adjustable valve in children with hydrocephalus. J Neurosurg 98:471\u2013476","journal-title":"J Neurosurg"}],"container-title":["Child's Nervous System"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00381-020-04520-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00381-020-04520-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00381-020-04520-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,3]],"date-time":"2021-02-03T00:13:12Z","timestamp":1612311192000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00381-020-04520-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,4]]},"references-count":26,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020,9]]}},"alternative-id":["4520"],"URL":"https:\/\/doi.org\/10.1007\/s00381-020-04520-x","relation":{},"ISSN":["0256-7040","1433-0350"],"issn-type":[{"value":"0256-7040","type":"print"},{"value":"1433-0350","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,4]]},"assertion":[{"value":"16 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"None to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}