{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,8]],"date-time":"2026-02-08T15:27:46Z","timestamp":1770564466637,"version":"3.49.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T00:00:00Z","timestamp":1630454400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T00:00:00Z","timestamp":1630454400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Childs Nerv Syst"],"published-print":{"date-parts":[[2021,10]]},"DOI":"10.1007\/s00381-021-05332-3","type":"journal-article","created":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T06:02:43Z","timestamp":1630476163000},"page":"3209-3217","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Accurate placement of parieto-occipital shunt ventricular catheter: use of craniometrics and technical note"],"prefix":"10.1007","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8310-6024","authenticated-orcid":false,"given":"Angela","family":"Li Ching Ng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saeed","family":"Kohan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,9,1]]},"reference":[{"key":"5332_CR1","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1159\/000120544","volume":"16","author":"KS Bierbrauer","year":"1990","unstructured":"Bierbrauer KS, Storrs BB, McLone DG, Tomita T, Dauser R (1990) A prospective, randomized study of shunt function and infections as a function of shunt placement. Pediatr Neurosurg 16:287\u2013291","journal-title":"Pediatr Neurosurg"},{"key":"5332_CR2","doi-asserted-by":"publisher","first-page":"157","DOI":"10.3171\/2016.8.PEDS16229","volume":"19","author":"WE Whitehead","year":"2017","unstructured":"Whitehead WE, Riva-Cambrin J, Kulkarni AV, Wellons JC 3rd, Rozzelle CJ, Tamber MS, Limbrick DD Jr, Browd SR, Naftel RP, Shannon CN, Simon TD, Holubkov R, Illner A, Cochrane DD, Drake JM, Luerssen TG, Oakes WJ, Kestle JR (2017) Ventricular catheter entry site and not catheter tip location predicts shunt survival: a secondary analysis of 3 large pediatric hydrocephalus studies. J Neurosurg Pediatr 19:157\u2013167","journal-title":"J Neurosurg Pediatr"},{"key":"5332_CR3","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1159\/000055960","volume":"33","author":"J Kestle","year":"2000","unstructured":"Kestle J, Drake J, Milner R, Sainte-Rose C, Cinalli G, Boop F, Piatt J, Haines S, Schiff S, Cochrane D, Steinbok P, MacNeil N (2000) Long-term follow-up data from the Shunt Design Trial. Pediatr Neurosurg 33:230\u2013236","journal-title":"Pediatr Neurosurg"},{"issue":"5","key":"5332_CR4","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1159\/000058428.","volume":"36","author":"MJ McGirt","year":"2002","unstructured":"McGirt MJ, Leveque J-C, Wellons JC III, Villavicencio AT, Hopkins JS, Fuchs HE, George TM (2002) Pediatr Neurosurg 36:248\u2013255","journal-title":"Pediatr Neurosurg"},{"key":"5332_CR5","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1159\/000333831","volume":"90","author":"R Sampath","year":"2012","unstructured":"Sampath R, Wadhwa R, Tawfik T, Nanda A, Guthikonda B (2012) Stereotactic Placement of ventricular catheters: does it affect proximal malfunction rates? Stereotact Funct Neurosurg 90:97\u2013103","journal-title":"Stereotact Funct Neurosurg"},{"key":"5332_CR6","doi-asserted-by":"publisher","first-page":"750","DOI":"10.3171\/jns.1994.80.4.0750","volume":"80","author":"D Pang","year":"1994","unstructured":"Pang D, Grabb PA (1994) Accurate placement of coronal ventricular catheter using stereotactic coordinate-guided free-hand passage. Technical note J Neurosurg 80:750\u2013755","journal-title":"Technical note J Neurosurg"},{"issue":"3","key":"5332_CR7","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.surneu.2007.07.020.","volume":"70","author":"CK Lee","year":"2008","unstructured":"Lee CK, Tay LL, Ng WH, Ng I, Ang BT (2008) Optimization of ventricular catheter placement via posterior approaches: a virtual reality simulation study. Surg Neurol\u00a070:274\u2013277; discussion 277\u2013278","journal-title":"Surg Neurol"},{"key":"5332_CR8","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.3171\/2010.3.JNS091237","volume":"113","author":"C Hayhurst","year":"2010","unstructured":"Hayhurst C, Beems T, Jenkinson MD, Byrne P, Clark S, Kandasamy J, Goodden J, Nandoe Tewarie RD, Mallucci CL (2010) Effect of electromagnetic-navigated shunt placement on failure rates: a prospective multicenter study. J Neurosurg 113:1273\u20131278","journal-title":"J Neurosurg"},{"key":"5332_CR9","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1227\/NEU.0000000000000849","volume":"77","author":"CL Nesvick","year":"2015","unstructured":"Nesvick CL, Khan NR, Mehta GU, Klimo P Jr (2015) Image guidance in ventricular cerebrospinal fluid shunt catheter placement: a systematic review and meta-analysis. Neurosurgery 77:321\u2013331","journal-title":"Neurosurgery"},{"key":"5332_CR10","volume-title":"Brain surgery: complication avoidance and management","author":"J Rouge","year":"1993","unstructured":"Rouge J, Mcloane D (1993) Brain surgery: complication avoidance and management. Churchill Livingstone"},{"key":"5332_CR11","doi-asserted-by":"publisher","first-page":"300","DOI":"10.3171\/jns.1995.82.2.0300","volume":"82","author":"MA Howard","year":"1995","unstructured":"Howard MA, Srinivasan J, Bevering CG, Winn HR, Grady MS (1995) A guide to placement of parietooccipital ventricular catheters. J Neurosurg 82:300","journal-title":"J Neurosurg"},{"key":"5332_CR12","doi-asserted-by":"publisher","first-page":"157","DOI":"10.3171\/jns.1998.89.1.0157","volume":"89","author":"PC Garell","year":"1998","unstructured":"Garell PC, Mirsky R, Noh MD, Loftus CM, Hitchon PW, Grady MS, Dacey RG, Howard MA (1998) Posterior ventricular catheter burr-hole localizer. J Neurosurg 89:157","journal-title":"J Neurosurg"}],"container-title":["Child's Nervous System"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00381-021-05332-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00381-021-05332-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00381-021-05332-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,13]],"date-time":"2021-10-13T05:13:09Z","timestamp":1634101989000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00381-021-05332-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,1]]},"references-count":12,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["5332"],"URL":"https:\/\/doi.org\/10.1007\/s00381-021-05332-3","relation":{},"ISSN":["0256-7040","1433-0350"],"issn-type":[{"value":"0256-7040","type":"print"},{"value":"1433-0350","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,1]]},"assertion":[{"value":"26 January 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The data and material used in this study were subject to patient consent for use in research and publication.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors report that there are no conflicts of interests to declare.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}