{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T05:55:14Z","timestamp":1759730114907},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2023,1,23]],"date-time":"2023-01-23T00:00:00Z","timestamp":1674432000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,1,23]],"date-time":"2023-01-23T00:00:00Z","timestamp":1674432000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"name":"Setting Scoliosis StraightFoundation"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Childs Nerv Syst"],"published-print":{"date-parts":[[2023,6]]},"DOI":"10.1007\/s00381-023-05834-2","type":"journal-article","created":{"date-parts":[[2023,1,23]],"date-time":"2023-01-23T07:02:53Z","timestamp":1674457373000},"page":"1573-1580","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Posterior cervical spinal fusion in the pediatric population using modern adult instrumentation \u2014 clinical outcome and safety"],"prefix":"10.1007","volume":"39","author":[{"given":"Alexander","family":"Spiessberger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter O.","family":"Newton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William","family":"Mackenzie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amer","family":"Samdani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Firoz","family":"Miyanji","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua","family":"Pahys","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suken","family":"Shah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Sponseller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Abel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Phillips","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michelle","family":"Marks","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Burt","family":"Yaszay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,1,23]]},"reference":[{"key":"5834_CR1","doi-asserted-by":"crossref","unstructured":"Liljenqvist UR, Halm HF, Link TM (1997) Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine (Phila Pa 1976) 22:2239\u201345","DOI":"10.1097\/00007632-199710010-00008"},{"key":"5834_CR2","doi-asserted-by":"crossref","unstructured":"Brown CA, Lenke LG, Bridwell KH et al (1998) Complications of pediatric thoracolumbar and lumbar pedicle screws. Spine (Phila Pa 1976) 23:1566\u201371","DOI":"10.1097\/00007632-199807150-00012"},{"key":"5834_CR3","doi-asserted-by":"crossref","unstructured":"Suk SI, Lee CK, Kim WJ et al (1995) Segmental pedicle screw fixation in the treatment of thoracic idiopathic scoliosis. Spine (Phila Pa 1976) 20:1399\u2013405","DOI":"10.1097\/00007632-199506020-00012"},{"key":"5834_CR4","doi-asserted-by":"crossref","unstructured":"Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 7\u201317","DOI":"10.1097\/00003086-198602000-00003"},{"key":"5834_CR5","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1302\/1863-2548.11.170115","volume":"11","author":"M Lastikka","year":"2017","unstructured":"Lastikka M, Aarnio J, Helenius I (2017) Instrumented cervical spinal fusions in children: indications and outcomes. J Child Orthop 11:419\u2013427","journal-title":"J Child Orthop"},{"key":"5834_CR6","unstructured":"Liao Y, Zhong D, Wang Q et al (2014) Application of pedicle screw internal fixation for atlantoaxial instability of children]. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 28:549\u201353"},{"key":"5834_CR7","doi-asserted-by":"publisher","first-page":"287","DOI":"10.4103\/jcvjs.JCVJS_166_20","volume":"11","author":"A Spiessberger","year":"2020","unstructured":"Spiessberger A, Dietz N, Gruter B et al (2020) Ehlers-Danlos syndrome-associated craniocervical instability with cervicomedullary syndrome: comparing outcome of craniocervical fusion with occipital bone versus occipital condyle fixation. J Craniovertebr Junct Spine 11:287","journal-title":"J Craniovertebr Junct Spine"},{"key":"5834_CR8","doi-asserted-by":"publisher","first-page":"380","DOI":"10.3171\/2009.10.PEDS09296","volume":"5","author":"TC Hankinson","year":"2010","unstructured":"Hankinson TC, Avellino AM, Harter D et al (2010) Equivalence of fusion rates after rigid internal fixation of the occiput to C-2 with or without C-1 instrumentation. J Neurosurg Pediatr 5:380\u2013384","journal-title":"J Neurosurg Pediatr"},{"key":"5834_CR9","doi-asserted-by":"publisher","first-page":"577","DOI":"10.3171\/2012.9.SPINE111021","volume":"17","author":"RE Elliott","year":"2012","unstructured":"Elliott RE, Tanweer O, Boah A et al (2012) Comparison of safety and stability of C-2 pars and pedicle screws for atlantoaxial fusion: meta-analysis and review of the literature. J Neurosurg Spine 17:577\u2013593","journal-title":"J Neurosurg Spine"},{"key":"5834_CR10","doi-asserted-by":"publisher","first-page":"1580","DOI":"10.1007\/s00586-012-2324-x","volume":"21","author":"X Ding","year":"2012","unstructured":"Ding X, Abumi K, Ito M et al (2012) A retrospective study of congenital osseous anomalies at the craniocervical junction treated by occipitocervical plate-rod systems. Eur Spine J 21:1580\u20131589","journal-title":"Eur Spine J"},{"key":"5834_CR11","doi-asserted-by":"crossref","unstructured":"Henderson FC, Sr. Rosenbaum R, Narayanan M et al (2020) Atlanto-axial rotary instability (Fielding type 1): characteristic clinical and radiological findings, and treatment outcomes following alignment, fusion, and stabilization. Neurosurg Rev","DOI":"10.1007\/s10143-020-01345-9"},{"key":"5834_CR12","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1186\/s12891-020-03838-6","volume":"21","author":"X Zou","year":"2020","unstructured":"Zou X, Ouyang B, Yang H et al (2020) Surgical treatment for basilar invagination with irreducible atlantoaxial dislocation: transoral atlantoaxial reduction plate fixation vs occipitocervical fixation. BMC Musculoskelet Disord 21:825","journal-title":"BMC Musculoskelet Disord"},{"key":"5834_CR13","doi-asserted-by":"publisher","first-page":"508","DOI":"10.3171\/2017.4.SPINE16831","volume":"27","author":"D Lau","year":"2017","unstructured":"Lau D, Winkler EA, Than KD et al (2017) Laminoplasty versus laminectomy with posterior spinal fusion for multilevel cervical spondylotic myelopathy: influence of cervical alignment on outcomes. J Neurosurg Spine 27:508\u2013517","journal-title":"J Neurosurg Spine"},{"key":"5834_CR14","doi-asserted-by":"crossref","unstructured":"Spiessberger A, Dietz N, Gruter B et al (2020) Junctional kyphosis and junctional failure after multi-segmental posterior cervicothoracic fusion\u2013a retrospective analysis of 64 patients. J Craniovertbr Junct Spine 11","DOI":"10.4103\/jcvjs.JCVJS_177_20"},{"key":"5834_CR15","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1055\/s-0035-1554776","volume":"6","author":"A Mesfin","year":"2016","unstructured":"Mesfin A, Bakhsh WR, Chuntarapas T et al (2016) Cervical scoliosis: clinical and radiographic outcomes. Global Spine J 6:7\u201313","journal-title":"Global Spine J"},{"key":"5834_CR16","doi-asserted-by":"crossref","unstructured":"Heller JG, Carlson GD, Abitbol JJ et al (1991) Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine. Spine (Phila Pa 1976) 16:S552\u20137","DOI":"10.1097\/00007632-199110001-00020"},{"key":"5834_CR17","doi-asserted-by":"crossref","unstructured":"Jeanneret B, Magerl F, Ward EH et al (1991) Posterior stabilization of the cervical spine with hook plates. Spine (Phila Pa 1976) 16:S56\u201363","DOI":"10.1097\/00007632-199103001-00010"},{"key":"5834_CR18","doi-asserted-by":"publisher","first-page":"610","DOI":"10.14245\/ns.2040436.218","volume":"17","author":"S Hartmann","year":"2020","unstructured":"Hartmann S, Thome C, Abramovic A et al (2020) The effect of rod pattern, outrigger, and multiple screw-rod constructs for surgical stabilization of the 3-column destabilized cervical spine - a biomechanical analysis and introduction of a novel technique. Neurospine 17:610\u2013629","journal-title":"Neurospine"},{"key":"5834_CR19","doi-asserted-by":"publisher","first-page":"390","DOI":"10.3171\/2012.8.SPINE12767","volume":"17","author":"G Al-Shamy","year":"2012","unstructured":"Al-Shamy G, Cherian J, Mata JA et al (2012) Computed tomography morphometric analysis for lateral mass screw placement in the pediatric subaxial cervical spine. J Neurosurg Spine 17:390\u2013396","journal-title":"J Neurosurg Spine"},{"key":"5834_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/2018.10.PEDS18327","volume":"23","author":"S Mendenhall","year":"2019","unstructured":"Mendenhall S, Mobasser D, Relyea K et al (2019) Spinal instrumentation in infants, children, and adolescents: a review. J Neurosurg Pediatr 23:1\u201315","journal-title":"J Neurosurg Pediatr"},{"key":"5834_CR21","doi-asserted-by":"publisher","first-page":"87","DOI":"10.3171\/2014.3.PEDS13626","volume":"14","author":"JG Savage","year":"2014","unstructured":"Savage JG, Fulkerson DH, Sen AN et al (2014) Fixation with C-2 laminar screws in occipitocervical or C1\u20132 constructs in children 5 years of age or younger: a series of 18 patients. J Neurosurg Pediatr 14:87\u201393","journal-title":"J Neurosurg Pediatr"},{"key":"5834_CR22","doi-asserted-by":"publisher","first-page":"e1021","DOI":"10.1016\/j.wneu.2020.11.079","volume":"146","author":"J Tirado-Caballero","year":"2021","unstructured":"Tirado-Caballero J, Moreno-Madueno G, Rivero-Garvia M et al (2021) Two-stage approach for unstable pediatric craniocervical junction anomalies with a halo vest and delayed occipitocervical fusion: technical note, case series, and literature review. World Neurosurg 146:e1021\u2013e1030","journal-title":"World Neurosurg"},{"key":"5834_CR23","doi-asserted-by":"publisher","first-page":"529","DOI":"10.3171\/2009.2.PEDS08149","volume":"3","author":"A Haque","year":"2009","unstructured":"Haque A, Price AV, Sklar FH et al (2009) Screw fixation of the upper cervical spine in the pediatric population. Clinical article J Neurosurg Pediatr 3:529\u2013533","journal-title":"Clinical article J Neurosurg Pediatr"},{"key":"5834_CR24","doi-asserted-by":"publisher","first-page":"397","DOI":"10.3171\/2012.8.SPINE12770","volume":"17","author":"SW Hwang","year":"2012","unstructured":"Hwang SW, Gressot LV, Rangel-Castilla L et al (2012) Outcomes of instrumented fusion in the pediatric cervical spine. J Neurosurg Spine 17:397\u2013409","journal-title":"J Neurosurg Spine"}],"container-title":["Child's Nervous System"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00381-023-05834-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00381-023-05834-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00381-023-05834-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,29]],"date-time":"2023-05-29T10:13:34Z","timestamp":1685355214000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00381-023-05834-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,23]]},"references-count":24,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2023,6]]}},"alternative-id":["5834"],"URL":"https:\/\/doi.org\/10.1007\/s00381-023-05834-2","relation":{},"ISSN":["0256-7040","1433-0350"],"issn-type":[{"value":"0256-7040","type":"print"},{"value":"1433-0350","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,23]]},"assertion":[{"value":"14 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"IRB approval was obtained.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Alexander Spiessberger, MD Nothing to disclose. Peter O. Newton, MD During the conduct of the study: grant to his institution from Setting Scoliosis Straight Foundation. Outside the submitted work: grants and other from Setting Scoliosis Straight Foundation; other from Rady Children\u2019s Specialists; grants, personal fees, and non-financial support from DePuy Synthes Spine; grants and other from SRS; grants from EOS imaging; personal fees from Thieme Publishing; grants from NuVasive; other from Electrocore; personal fees from Cubist; other from International Pediatric Orthopedic Think Tank; grants, non-financial support, and other from Orthopediatrics; grants, personal fees, and non-financial support from Stryker\/K2M; grants and non-financial support from Alphatech; grants from Mazor Robotics; personal fees from MiRus; personal fees from Globus Medical; personal fees from Pacira, from Scoliosis Research Society. In addition, Dr. Newton has a patent Anchoring systems and methods for correcting spinal deformities (8540754) with royalties paid to DePuy Synthes Spine, a patent Low profile spinal tethering systems (8123749) licensed to DePuy Spine, Inc., a patent Screw placement guide (7981117) licensed to DePuy Spine, Inc., a patent Compressor for use in minimally invasive surgery (7189244) licensed to DePuy Spine, Inc., and a patent Posterior spinal fixation pending to K2M. William Mackenzie, MD During the conduct of the study: grants to his institution from Setting Scoliosis Straight Foundation. Outside the submitted work: consultant fees paid to Institutional Honorarium from BioMarin Pharmaceuticals Inc. Amer Samdani, MD During the conduct of the study: grants to his institution from Setting Scoliosis Straight Foundation. Outside the submitted work: personal fees from DePuy Synthes Spine, personal fees from Ethicon, personal fees from Globus Medical, personal fees from Medical Device Business Services, personal fees from Mirus, personal fees from NuVasive, personal fees from Orthofix, personal fees from Stryker, personal fees from Zimmer Biomet; Board and executive committee Setting Scoliosis Straight Foundation (no compensation); Executive Committee Pediatric Spine Study Group (no compensation). Firoz Miyanji, MD During the conduct of this study: grants to his institution from Setting Scoliosis Straight Foundation. Outside the submitted work: grants and personal fees from DePuy, personal fees from Orthopediatrics, other from Pediatric Orthopaedic Society of North America, personal fees from Stryker, personal fees from Zimmer. Joshua Pahys, MD Outside the submitted work: personal fees from Nuvasive, personal fees from Zimmer Biomet, personal fees from DePuy Synthes Spine. Suken Shah, MD During the conduct of the study: grants to his institution from Setting Scoliosis Straight Foundation. Outside the submitted work: personal fees from DePuy Synthes Spine. Paul Sponseller, MD During the conduct of the study: grants to his institution from Setting Scoliosis Straight Foundation. Outside the submitted work: personal fees from DePuy Synthes Spine, personal fees from Globus, personal fees from Orthopediatrics, personal fees from Pacira. Mark Abel, MD During the conduct of the study: grants to his institution from Setting Scoliosis Straight Foundation (grant from DePuy Synthes Spine to SSSF). Jonathan Phillips, MD During the conduct of the study: grants to his institution from Setting Scoliosis Straight Foundation. Outside the submitted work: Royalties from Biomet, board or committee member for and royalties from OrthoPaediatrics, other from Spine Advisory Board OrthoPaediatrics, other from Springer. Michelle Marks, MA, PT During the conduct of the study: employee of and serves on the Board of Directors of the Setting Scoliosis Straight Foundation. Burt Yaszay, MD During the conduct of the study: grants to his institution from Setting Scoliosis Straight. Outside the submitted work: grants and personal fees from Stryker, grants and personal fees from Depuy Synthes, grants and personal fees from Nuvasive, personal fees from Globus, personal fees from Orthopediatrics, personal fees from Biogen, personal fees from Medtronic.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}