{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T03:36:45Z","timestamp":1776224205618,"version":"3.50.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T00:00:00Z","timestamp":1770681600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T00:00:00Z","timestamp":1770681600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Childs Nerv Syst"],"DOI":"10.1007\/s00381-026-07157-4","type":"journal-article","created":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T03:16:12Z","timestamp":1770693372000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Carbon fiber-reinforced polyetheretherketone spinal instrumentation in pediatric spinal tumors: report of two cases and review of the literature"],"prefix":"10.1007","volume":"42","author":[{"given":"Tomoko","family":"Tanaka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eliezer","family":"Villanueva-Castro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hector","family":"Soriano-Baron","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,2,10]]},"reference":[{"key":"7157_CR1","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s11060-024-04842-9","volume":"171","author":"J Ward","year":"2025","unstructured":"Ward J, Damante M, Wilson S et al (2025) Impact of instrumentation material on local recurrence: a case-matched series using carbon fiber\u2013PEEK vs titanium. J Neurooncol 171:155\u2013162. https:\/\/doi.org\/10.1007\/s11060-024-04842-9","journal-title":"J Neurooncol"},{"key":"7157_CR2","doi-asserted-by":"publisher","first-page":"e131","DOI":"10.1016\/j.prro.2024.10.011","volume":"15","author":"J Ward","year":"2025","unstructured":"Ward J, Damante M, Wilson S et al (2025) Use of magnetic resonance imaging for postoperative radiation therapy planning in patients with carbon fiber\u2013reinforced polyetheretherketone instrumentation. Pract Radiat Oncol 15:e131\u2013e137. https:\/\/doi.org\/10.1016\/j.prro.2024.10.011","journal-title":"Pract Radiat Oncol"},{"key":"7157_CR3","doi-asserted-by":"publisher","first-page":"317","DOI":"10.14245\/ns.2244920.460","volume":"20","author":"C Alvarez-Breckenridge","year":"2023","unstructured":"Alvarez-Breckenridge C, de Almeida R, Haider A et al (2023) Carbon fiber\u2013reinforced polyetheretherketone spinal implants for treatment of spinal tumors: perceived advantages and limitations. Neurospine 20:317\u2013326. https:\/\/doi.org\/10.14245\/ns.2244920.460","journal-title":"Neurospine"},{"key":"7157_CR4","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1159\/000531984","volume":"58","author":"JI Kumar","year":"2023","unstructured":"Kumar JI, Jallo GI, Shimony N (2023) Knowledge review of spinal deformity and the need for fusion and fixation following treatment for spinal tumors among the pediatric age group. Pediatr Neurosurg 58:281\u2013289. https:\/\/doi.org\/10.1159\/000531984","journal-title":"Pediatr Neurosurg"},{"key":"7157_CR5","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2024.1416046","volume":"12","author":"C Li","year":"2024","unstructured":"Li C, Zhao Y, Qi L et al (2024) Comparison of biomechanical effects of polyetheretherketone (PEEK) rods and titanium rods in lumbar long-segment instrumentation: a finite element study. Front Bioeng Biotechnol 12:1416046. https:\/\/doi.org\/10.3389\/fbioe.2024.1416046","journal-title":"Front Bioeng Biotechnol"},{"key":"7157_CR6","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1007\/s00701-022-05314-7","volume":"165","author":"A Shtaya","year":"2023","unstructured":"Shtaya A, Wahab S, Waters R et al (2023) Carbon fibre instrumentation for scoliosis surgery in children with spinal cord intramedullary tumours: a novel technical note. Acta Neurochir (Wien) 165:83\u201388. https:\/\/doi.org\/10.1007\/s00701-022-05314-7","journal-title":"Acta Neurochir (Wien)"},{"key":"7157_CR7","doi-asserted-by":"publisher","first-page":"3229","DOI":"10.1007\/s00586-020-06534-0","volume":"29","author":"S Boriani","year":"2020","unstructured":"Boriani S, Pipola V, Cecchinato R et al (2020) Composite PEEK\/carbon fiber rods in the treatment for bone tumors of the cervical spine: a case series. Eur Spine J 29:3229\u20133236. https:\/\/doi.org\/10.1007\/s00586-020-06534-0","journal-title":"Eur Spine J"},{"key":"7157_CR8","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1007\/s00586-017-5258-5","volume":"27","author":"S Boriani","year":"2018","unstructured":"Boriani S, Tedesco G, Ming L et al (2018) Carbon-fiber\u2013reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report. Eur Spine J 27:874\u2013881. https:\/\/doi.org\/10.1007\/s00586-017-5258-5","journal-title":"Eur Spine J"},{"key":"7157_CR9","doi-asserted-by":"publisher","first-page":"323","DOI":"10.21037\/jss.2017.06.20","volume":"3","author":"G Tedesco","year":"2017","unstructured":"Tedesco G, Gasbarrini A, Bandiera S et al (2017) Composite PEEK\/carbon fiber implants can increase the effectiveness of radiotherapy in the management of spine tumors. J Spine Surg 3:323\u2013329. https:\/\/doi.org\/10.21037\/jss.2017.06.20","journal-title":"J Spine Surg"},{"key":"7157_CR10","doi-asserted-by":"publisher","first-page":"534","DOI":"10.3171\/2023.5.SPINE23106","volume":"39","author":"HA Khan","year":"2023","unstructured":"Khan HA, Ber R, Neifert SN et al (2023) Carbon fiber\u2013reinforced PEEK spinal implants for primary and metastatic spine tumors: a systematic review on implant complications and radiotherapy benefits. J Neurosurg Spine 39:534\u2013547. https:\/\/doi.org\/10.3171\/2023.5.SPINE23106","journal-title":"J Neurosurg Spine"},{"key":"7157_CR11","doi-asserted-by":"publisher","first-page":"1737","DOI":"10.1007\/s00256-024-04624-4","volume":"53","author":"GC Feuerriegel","year":"2024","unstructured":"Feuerriegel GC, Sutter R (2024) Managing hardware-related metal artifacts in MRI: current and evolving techniques. Skelet Radiol 53:1737\u20131750. https:\/\/doi.org\/10.1007\/s00256-024-04624-4","journal-title":"Skelet Radiol"},{"issue":"Suppl 4","key":"7157_CR12","doi-asserted-by":"publisher","DOI":"10.1002\/pbc.30150","volume":"70","author":"SN Rogers","year":"2023","unstructured":"Rogers SN, Udayasankar U, Pruthi S et al (2023) Imaging of pediatric spine and spinal cord tumors: a COG diagnostic imaging committee\/SPR oncology committee\/ASPNR white paper. Pediatr Blood Cancer 70(Suppl 4):e30150. https:\/\/doi.org\/10.1002\/pbc.30150","journal-title":"Pediatr Blood Cancer"},{"key":"7157_CR13","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.jocn.2016.06.003","volume":"34","author":"V Tsitouras","year":"2016","unstructured":"Tsitouras V, Wang S, Dirks P et al (2016) Management and outcome of chordomas in the pediatric population: the Hospital for Sick Children experience and review of the literature. J Clin Neurosci 34:169\u2013176. https:\/\/doi.org\/10.1016\/j.jocn.2016.06.003","journal-title":"J Clin Neurosci"},{"key":"7157_CR14","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1007\/s10143-020-01384-2","volume":"44","author":"T Kr\u00e4tzig","year":"2021","unstructured":"Kr\u00e4tzig T, Mende KC, Mohme M et al (2021) Carbon fiber\u2013reinforced PEEK versus titanium implants: an in vitro comparison of susceptibility artifacts in CT and MR imaging. Neurosurg Rev 44:2163\u20132170. https:\/\/doi.org\/10.1007\/s10143-020-01384-2","journal-title":"Neurosurg Rev"},{"key":"7157_CR15","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.wneu.2021.05.100","volume":"152","author":"A Takayanagi","year":"2021","unstructured":"Takayanagi A, Siddiqi I, Ghanchi H et al (2021) Radiolucent carbon fiber\u2013reinforced implants for treatment of spinal tumors\u2014clinical, radiographic, and dosimetric considerations. World Neurosurg 152:61\u201370. https:\/\/doi.org\/10.1016\/j.wneu.2021.05.100","journal-title":"World Neurosurg"},{"issue":"5","key":"7157_CR16","doi-asserted-by":"publisher","DOI":"10.3171\/2025.2.FOCUS24976","volume":"58","author":"M Damante","year":"2025","unstructured":"Damante M, Wilson S, Ward J et al (2025) Durability of carbon fiber\u2013reinforced PEEK spinal instrumentation in spine oncology: a single-institution longitudinal experience. Neurosurg Focus 58(5):E10. https:\/\/doi.org\/10.3171\/2025.2.FOCUS24976","journal-title":"Neurosurg Focus"},{"key":"7157_CR17","unstructured":"CarboFix Orthopedics Ltd (2023) CarboClear\u00ae Pedicle Screw System brochure. Available at: https:\/\/mf2com.com.br\/ortospine\/pdf\/pediclescrewsystem\/carboclear_brochure_v5.pdf (Accessed 10 Sep 2025)"},{"key":"7157_CR18","unstructured":"Icotec AG (2024) VADER\u00ae Pedicle System\u2014Fact Sheet. Available at: https:\/\/www.icotec-medical.com\/wp-content\/uploads\/2021\/10\/Factsheets_Pedicle-Systems_US.pdf (Accessed 10 Sep 2025)"},{"key":"7157_CR19","doi-asserted-by":"publisher","first-page":"504","DOI":"10.3171\/2015.6.PEDS14523","volume":"17","author":"Y Li","year":"2016","unstructured":"Li Y, Shen Z, Wang X et al (2016) Computed tomography morphometric analysis of anterior instrumentation in the pediatric thoracic spine. J Neurosurg Pediatr 17:504\u2013509. https:\/\/doi.org\/10.3171\/2015.6.PEDS14523","journal-title":"J Neurosurg Pediatr"},{"key":"7157_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.aanat.2024.152349","volume":"257","author":"C Liu","year":"2025","unstructured":"Liu C, Chen J, Huang C et al (2025) CT imaging analysis of the C7 pedicle and lateral mass in children aged 0\u201314 years. Ann Anat - Anat Anz 257:152349. https:\/\/doi.org\/10.1016\/j.aanat.2024.152349","journal-title":"Ann Anat - Anat Anz"},{"key":"7157_CR21","doi-asserted-by":"publisher","first-page":"499","DOI":"10.3390\/surgeries5030041","volume":"5","author":"I Amadi","year":"2024","unstructured":"Amadi I, Kabangu JLK, Bhargav AG, Ohiorhenuan IE (2024) Advances in instrumentation and implant technology for spine oncology: a focus on carbon fiber technologies. Surgeries 5:499\u2013516. https:\/\/doi.org\/10.3390\/surgeries5030041","journal-title":"Surgeries"}],"container-title":["Child's Nervous System"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00381-026-07157-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00381-026-07157-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00381-026-07157-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T16:06:37Z","timestamp":1770739597000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00381-026-07157-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,10]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["7157"],"URL":"https:\/\/doi.org\/10.1007\/s00381-026-07157-4","relation":{},"ISSN":["1433-0350"],"issn-type":[{"value":"1433-0350","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,10]]},"assertion":[{"value":"5 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"65"}}