{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T14:13:56Z","timestamp":1768313636340,"version":"3.49.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,12]],"date-time":"2020-05-12T00:00:00Z","timestamp":1589241600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,5,12]],"date-time":"2020-05-12T00:00:00Z","timestamp":1589241600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Res Cardiol"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Low prosthesis position after transcatheter aortic valve implantation (TAVI) is associated with higher rates of new onset conduction disturbances and permanent pacemaker implantations. Purpose of this study was to investigate possible predictors of a low prosthesis position of the SAPIEN 3 (Edwards Lifesciences, Irvine, California, USA) valve type using fusion imaging of pre- and post-procedural computed tomography angiography (CTA).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>CTA fusion imaging was performed in 120 TAVI-patients with 3D-reconstruction of the transcatheter heart valve (THV) position within the device landing zone. A low implantation position was defined according to the manufacturer\u2019s recommendations as &gt;\u200930% of the prosthesis below the native annulus plane.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A low THV position was found in 17 patients (14%). Patients with low THV position had less calcification of the annulus region and a smaller annulus size compared to patients with a normal or high THV position (<jats:italic>P<\/jats:italic>\u2009=\u20090.003 and 0.041, respectively). The only independent predictor of a low THV position in multivariate logistic regression analysis was the extent of calcification of the cusp region (odds ratio [CI] 0.842 [0.727\u20130.976], <jats:italic>P<\/jats:italic>\u2009=\u20090.022).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Fusion imaging of pre-and post-procedural CTA identified reduced calcification of the cusp region as an independent predictor of a low THV position of the SAPIEN 3. This should be considered when planning the TAVI procedure.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Graphic abstract<\/jats:title>\n                <jats:p>Correlation of cusp region calcification and prosthesis position after TAVI<\/jats:p>\n                \n              <\/jats:sec>","DOI":"10.1007\/s00392-020-01654-5","type":"journal-article","created":{"date-parts":[[2020,5,12]],"date-time":"2020-05-12T13:03:51Z","timestamp":1589288631000},"page":"93-101","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Predictors for low TAVI-prosthesis position assessed by fusion imaging of pre- and post-procedural CT angiography"],"prefix":"10.1007","volume":"110","author":[{"given":"Philipp","family":"Breitbart","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gregor","family":"Pache","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Minners","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manuel","family":"Hein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Holger","family":"Schr\u00f6fel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franz-Josef","family":"Neumann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Ruile","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,5,12]]},"reference":[{"key":"1654_CR1","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1016\/j.jcin.2015.09.036","volume":"9","author":"O Husser","year":"2016","unstructured":"Husser O, Pellegrini C, Kessler T, Burgdorf C, Thaller H, Mayr NP, Kasel AM, Kastrati A, Schunkert H, Hengstenberg C (2016) Predictors of permanent pacemaker implantations and new-onset conduction abnormalities with the SAPIEN 3 balloon-expandable transcatheter heart valve. JACC Cardiovasc Interv 9:244\u2013254. https:\/\/doi.org\/10.1016\/j.jcin.2015.09.036","journal-title":"JACC Cardiovasc Interv"},{"key":"1654_CR2","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.1161\/CIRCULATIONAHA.116.025103","volume":"135","author":"O Wendler","year":"2017","unstructured":"Wendler O, Schymik G, Treede H, Baumgartner H, Dumonteil N, Ihlberg L, Neumann FJ, Tarantini G, Zamarano JL, Vahanian A (2017) SOURCE 3 registry: design and 30-day results of the european postapproval registry of the latest generation of the SAPIEN 3 transcatheter heart valve. Circulation 135:1123\u20131132. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.116.025103","journal-title":"Circulation"},{"key":"1654_CR3","doi-asserted-by":"publisher","first-page":"2252","DOI":"10.1093\/eurheartj\/ehw112","volume":"37","author":"S Kodali","year":"2016","unstructured":"Kodali S, Thourani VH, White J, Malaisrie SC, Lim S, Greason KL, Williams M, Guerrero M, Eisenhauer AC, Kapadia S, Kereiakes DJ, Herrmann HC, Babaliaros V, Szeto WY, Hahn RT, Pibarot P, Weissman NJ, Leipsic J, Blanke P, Whisenant BK, Suri RM, Makkar RR, Ayele GM, Svensson LG, Webb JG, Mack MJ, Smith CR, Leon MB (2016) Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis. Eur Heart J 37:2252\u20132262. https:\/\/doi.org\/10.1093\/eurheartj\/ehw112","journal-title":"Eur Heart J"},{"key":"1654_CR4","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.116.004088","author":"T Pilgrim","year":"2016","unstructured":"Pilgrim T, Stortecky S, Nietlispach F, Heg D, Tueller D, Toggweiler S, Ferrari E, Noble S, Maisano F, Jeger R, Roffi M, Gr\u00fcnenfelder J, Huber C, Wenaweser P, Windecker S (2016) Repositionable versus balloon-expandable devices for transcatheter aortic valve implantation in patients with aortic stenosis. J Am Heart Assoc. https:\/\/doi.org\/10.1161\/JAHA.116.004088","journal-title":"J Am Heart Assoc"},{"key":"1654_CR5","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1136\/heartjnl-2015-307666","volume":"101","author":"JM Dizon","year":"2015","unstructured":"Dizon JM, Nazif TM, Hess PL, Biviano A, Garan H, Douglas PS, Kapadia S, Babaliaros V, Herrmann HC, Szeto WY, Jilaihawi H, Fearon WF, Tuzcu EM, Pichard AD, Makkar R, Williams M, Hahn RT, Xu K, Smith CR, Leon MB, Kodali SK (2015) Chronic pacing and adverse outcomes after transcatheter aortic valve implantation. Heart 101:1665\u20131671. https:\/\/doi.org\/10.1136\/heartjnl-2015-307666","journal-title":"Heart"},{"key":"1654_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00392-014-0739-6","volume":"104","author":"M Martinez-Selles","year":"2015","unstructured":"Martinez-Selles M, Bramlage P, Thoenes M, Schymik G (2015) Clinical significance of conduction disturbances after aortic valve intervention: current evidence. Clin Res Cardiol 104:1\u201312. https:\/\/doi.org\/10.1007\/s00392-014-0739-6","journal-title":"Clin Res Cardiol"},{"key":"1654_CR7","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-020-01601-4","author":"J Blumenstein","year":"2020","unstructured":"Blumenstein J, M\u00f6llmann H, Bleiziffer S, Bauer T, Ensminger S, Bekeredjian R, Walther T, Frerker C, Beyersdorf F, Hamm C, Beckmann A (2020) Transcatheter aortic valve implantation in nonagenarians: insights from the German Aortic Valve Registry (GARY). Clin Res Cardiol. https:\/\/doi.org\/10.1007\/s00392-020-01601-4","journal-title":"Clin Res Cardiol"},{"key":"1654_CR8","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1111\/joic.12302","volume":"29","author":"M Schwerg","year":"2016","unstructured":"Schwerg M, Fulde F, Dreger H, Poller WC, Stangl K, Laule M (2016) Optimized implantation height of the edwards SAPIEN 3 valve to minimize pacemaker implantation after. J Intervent Cardiol 29:370\u2013374. https:\/\/doi.org\/10.1111\/joic.12302","journal-title":"J Intervent Cardiol"},{"key":"1654_CR9","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1016\/j.amjcard.2010.10.054","volume":"107","author":"C Fraccaro","year":"2011","unstructured":"Fraccaro C, Buja G, Tarantini G, Gasparetto V, Leoni L, Razzolini R, Corrado D, Bonato R, Basso C, Thiene G, Gerosa G, Isabella G, Iliceto S, Napodano M (2011) Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation. Am J Cardiol 107:747\u2013754. https:\/\/doi.org\/10.1016\/j.amjcard.2010.10.054","journal-title":"Am J Cardiol"},{"key":"1654_CR10","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1093\/ehjci\/jey195","volume":"20","author":"P Ruile","year":"2019","unstructured":"Ruile P, Pache G, Minners J, Hein M, Neumann F-J, Breitbart P (2019) Fusion imaging of pre- and post-procedural computed tomography angiography in transcatheter aortic valve implantation patients: evaluation of prosthesis position and its influence on new conduction disturbances. Eur Heart J Cardiovasc Imaging 20:781\u2013788. https:\/\/doi.org\/10.1093\/ehjci\/jey195","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"1654_CR11","doi-asserted-by":"publisher","first-page":"2263","DOI":"10.1093\/eurheartj\/ehv526","volume":"37","author":"G Pache","year":"2016","unstructured":"Pache G, Schoechlin S, Blanke P, Dorfs S, Jander N, Arepalli CD, Gick M, Buettner HJ, Leipsic J, Langer M, Neumann FJ, Ruile P (2016) Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves. Eur Heart J 37:2263\u20132271. https:\/\/doi.org\/10.1093\/eurheartj\/ehv526","journal-title":"Eur Heart J"},{"key":"1654_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00392-019-01528-5","volume":"109","author":"W von Scheidt","year":"2020","unstructured":"von Scheidt W, Welz A, Pauschinger M et al (2020) Interdisciplinary consensus on indications for transfemoral transcatheter aortic valve implantation (TF-TAVI): Joint Consensus Document of the Arbeitsgemeinschaft Leitende Kardiologische Krankenhaus\u00e4rzte e.V. (ALKK) and cooperating Cardiac Surgery Departments. Clin Res Cardiol 109:1\u201312. https:\/\/doi.org\/10.1007\/s00392-019-01528-5","journal-title":"Clin Res Cardiol"},{"key":"1654_CR13","doi-asserted-by":"publisher","first-page":"842","DOI":"10.1161\/CIRCULATIONAHA.105.582882","volume":"113","author":"JG Webb","year":"2006","unstructured":"Webb JG, Chandavimol M, Thompson CR, Ricci DR, Carere RG, Munt BI, Buller CE, Pasupati S, Lichtenstein S (2006) Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation 113:842\u2013850. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.105.582882","journal-title":"Circulation"},{"key":"1654_CR14","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1148\/radiol.13120696","volume":"269","author":"P Blanke","year":"2013","unstructured":"Blanke P, Schoepf UJ, Leipsic JA (2013) CT in transcatheter aortic valve replacement. Radiology 269:650\u2013669. https:\/\/doi.org\/10.1148\/radiol.13120696","journal-title":"Radiology"},{"key":"1654_CR15","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1111\/joic.12182","volume":"28","author":"MI Murray","year":"2015","unstructured":"Murray MI, Geis N, Pleger ST, Kallenbach K, Katus HA, Bekeredjian R, Chorianopoulos E (2015) First experience with the new generation Edwards Sapien 3 aortic bioprosthesis: procedural results and short term outcome. J Intervent Cardiol 28:109\u2013116. https:\/\/doi.org\/10.1111\/joic.12182","journal-title":"J Intervent Cardiol"},{"key":"1654_CR16","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/j.jcin.2015.12.023","volume":"9","author":"F De Torres-Alba","year":"2016","unstructured":"De Torres-Alba F, Kaleschke G, Diller GP, Vormbrock J, Orwat S, Radke R, Reinke F, Fischer D, Reinecke H, Baumgartner H (2016) Changes in the pacemaker rate after transition from edwards SAPIEN XT to SAPIEN 3 transcatheter aortic valve implantation: the critical role of valve implantation height. JACC Cardiovasc Interv 9:805\u2013813. https:\/\/doi.org\/10.1016\/j.jcin.2015.12.023","journal-title":"JACC Cardiovasc Interv"},{"key":"1654_CR17","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1007\/s00392-019-01509-8","volume":"109","author":"L Gaede","year":"2020","unstructured":"Gaede L, Blumenstein J, Liebetrau C, D\u00f6rr O, Kim WK, Nef H, Husser O, G\u00fclker J, Els\u00e4sser A, Hamm CW, Achenbach S, M\u00f6llmann H (2020) Transvascular transcatheter aortic valve implantation in 2017. Clin Res Cardiol 109:303\u2013314. https:\/\/doi.org\/10.1007\/s00392-019-01509-8","journal-title":"Clin Res Cardiol"},{"key":"1654_CR18","doi-asserted-by":"publisher","first-page":"2200","DOI":"10.1016\/j.jcin.2016.08.034","volume":"9","author":"V Mauri","year":"2016","unstructured":"Mauri V, Reimann A, Stern D, Scherner M, Kuhn E, Rudolph V, Rosenkranz S, Eghbalzadeh K, Friedrichs K, Wahlers T, Baldus S, Madershahian N, Rudolph TK (2016) Predictors of permanent pacemaker implantation after transcatheter aortic valve replacement with the SAPIEN 3. JACC Cardiovasc Interv 9:2200\u20132209. https:\/\/doi.org\/10.1016\/j.jcin.2016.08.034","journal-title":"JACC Cardiovasc Interv"},{"key":"1654_CR19","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1002\/ccd.22563","volume":"76","author":"G Latsios","year":"2010","unstructured":"Latsios G, Gerckens U, Buellesfeld L, Mueller R, John D, Yuecel S, Syring J, Sauren B, Grube E (2010) \u201cDevice landing zone\u201d calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI. Catheter Cardiovasc Interv 76:431\u2013439. https:\/\/doi.org\/10.1002\/ccd.22563","journal-title":"Catheter Cardiovasc Interv"}],"container-title":["Clinical Research in Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00392-020-01654-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00392-020-01654-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00392-020-01654-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,11]],"date-time":"2021-05-11T23:49:44Z","timestamp":1620776984000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00392-020-01654-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,12]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["1654"],"URL":"https:\/\/doi.org\/10.1007\/s00392-020-01654-5","relation":{},"ISSN":["1861-0684","1861-0692"],"issn-type":[{"value":"1861-0684","type":"print"},{"value":"1861-0692","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,12]]},"assertion":[{"value":"20 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}