{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T11:40:06Z","timestamp":1744630806789,"version":"3.40.4"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","license":[{"start":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T00:00:00Z","timestamp":1744588800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T00:00:00Z","timestamp":1744588800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum M\u00fcnster"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Clin Res Cardiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Aims<\/jats:title>\n            <jats:p>The number of patients with cardiac implantable electronic devices (CIEDs) is increasing. However, there is limited experience regarding vasodilator-stress cardiovascular magnetic resonance (CMR) and resulting device artifacts on perfusion images. The aim of this study was to determine CMR image quality in patients with different CIED types for CMR-based perfusion stress testing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods and results<\/jats:title>\n            <jats:p>A total of 156 patients with active CIEDs underwent CMR on a 1.5-Tesla scanner. Both conventional steady-state-free-precession (SSFP) and modified spoiled gradient-echo (sGE) protocols under stress and resting conditions were used to evaluate image artifacts in a 16-segment segment model of the heart. The study group comprised 39% conventional pacemaker (PM), 4% cardiac resynchronization therapy-pacemaker (CRT-P), 38% conventional implantable cardioverter-defibrillator (ICD), 6% cardiac resynchronization therapy-ICD (CRT-D), and 13% subcutaneous ICD (S-ICD) patients. PM-carriers showed only minor image artifacts in both perfusion protocols. Artifacts caused by ICDs were predominantly located in the left-ventricular (LV) inferolateral and anterior segments. S-ICDs showed the highest extent of artifacts with an anterolateral accentuation. The artifact extent was significantly reduced when sGE-based perfusion was used compared to SSFP-based sequences. 69% of the patients received a stress-perfusion protocol, and elective coronary angiography confirmed the presence of coronary stenosis in three cases. No major safety-relevant issues occurred.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Myocardial perfusion imaging by CMR is safe and feasible with moderate-to-high image quality in patients with all types of CIEDs, including non-conditional devices, ICDs, and S-ICDs. A sGE-based perfusion protocol should be preferred in patients with left-sided ICDs, CRT-Ds, or S-ICDs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Graphical abstract<\/jats:title>\n          <\/jats:sec>","DOI":"10.1007\/s00392-025-02636-1","type":"journal-article","created":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T10:58:22Z","timestamp":1744628302000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["First-pass perfusion imaging using cardiovascular magnetic resonance in patients with various cardiac implantable electronic devices"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3097-3500","authenticated-orcid":false,"given":"Claudia","family":"Meier","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Bietenbeck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Theofanidou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Volker","family":"Vehof","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Stalling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dennis","family":"Korthals","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bishwas","family":"Chamling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Misael","family":"Estepa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Doeblin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Kelle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali","family":"Yilmaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,4,14]]},"reference":[{"issue":"14","key":"2636_CR1","doi-asserted-by":"publisher","first-page":"1741","DOI":"10.1016\/j.jacc.2019.07.074","volume":"74","author":"RY Kwong","year":"2019","unstructured":"Kwong RY, Ge Y, Steel K, Bingham S, Abdullah S, Fujikura K et al (2019) Cardiac magnetic resonance stress perfusion imaging for evaluation of patients with chest pain. J Am Coll Cardiol 74(14):1741\u20131755","journal-title":"J Am Coll Cardiol"},{"issue":"25","key":"2636_CR2","doi-asserted-by":"publisher","first-page":"2418","DOI":"10.1056\/NEJMoa1716734","volume":"380","author":"E Nagel","year":"2019","unstructured":"Nagel E, Greenwood JP, McCann GP, Bettencourt N, Shah AM, Hussain ST et al (2019) Magnetic resonance perfusion or fractional flow reserve in coronary disease. N Engl J Med 380(25):2418\u20132428","journal-title":"N Engl J Med"},{"issue":"3","key":"2636_CR3","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1093\/eurheartj\/ehz425","volume":"41","author":"J Knuuti","year":"2019","unstructured":"Knuuti J, Wijns W, Saraste A, Capodanno D, Barbato E, Funck-Brentano C et al (2019) ESC guidelines for the diagnosis and management of chronic coronary syndromes: the task force for the diagnosis and management of chronic coronary syndromes of the European Society of Cardiology (ESC). Eur Heart J 41(3):407\u201377. https:\/\/doi.org\/10.1093\/eurheartj\/ehz425","journal-title":"Eur Heart J"},{"issue":"9","key":"2636_CR4","doi-asserted-by":"publisher","first-page":"e9","DOI":"10.1161\/CIR.0000000000001168","volume":"148","author":"SS Virani","year":"2023","unstructured":"Virani SS, Newby LK, Arnold SV, Bittner V, Brewer LC, Demeter SH et al (2023) AHA\/ACC\/ACCP\/ASPC\/NLA\/PCNA guideline for the management of patients with chronic coronary disease: a report of the American heart association\/American college of cardiology joint committee on clinical practice guidelines. Circulation 148(9):e9-119. https:\/\/doi.org\/10.1161\/CIR.0000000000001168","journal-title":"Circulation"},{"issue":"9814","key":"2636_CR5","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1016\/S0140-6736(11)61335-4","volume":"379","author":"JP Greenwood","year":"2012","unstructured":"Greenwood JP, Maredia N, Younger JF, Brown JM, Nixon J, Everett CC et al (2012) Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet 379(9814):453\u2013460","journal-title":"Lancet"},{"key":"2636_CR6","doi-asserted-by":"publisher","first-page":"ii1","DOI":"10.1093\/europace\/eux258","volume":"19","author":"MJP Raatikainen","year":"2017","unstructured":"Raatikainen MJP, Arnar DO, Merkely B, Nielsen JC, Hindricks G, Heidbuchel H et al (2017) A decade of information on the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European society of cardiology countries: 2017 report from the European heart rhythm association. Europace 19:ii1\u2013ii90","journal-title":"Europace"},{"issue":"4","key":"2636_CR7","doi-asserted-by":"publisher","first-page":"E126","DOI":"10.1148\/rg.2021200092","volume":"41","author":"EM Lee","year":"2021","unstructured":"Lee EM, Ibrahim ESH, Dudek N, Lu JC, Kalia V, Runge M et al (2021) Improving MR image quality in patients with metallic implants. Radiographics 41(4):E126\u2013E137","journal-title":"Radiographics"},{"issue":"1","key":"2636_CR8","doi-asserted-by":"publisher","first-page":"e33","DOI":"10.1093\/ehjci\/jead273","volume":"25","author":"I Stankovic","year":"2023","unstructured":"Stankovic I, Voigt JU, Burri H, Muraru D, Sade LE, Haugaa KH et al (2023) Imaging in patients with cardiovascular implantable electronic devices: part 2-imaging after device implantation. A clinical consensus statement of the European association of cardiovascular imaging (EACVI) and the European heart rhythm association (EHRA) of the ESC. Eur Heart J Cardiovasc Imaging 25(1):e33-54","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"2636_CR9","doi-asserted-by":"crossref","unstructured":"Kim D, Collins JD, White JA, Hanneman K, Lee DC, Patel AR, et al. (2024) SCMR expert consensus statement for cardiovascular magnetic resonance of patients with a cardiac implantable electronic device. Journal of Cardiovascular Magnetic Resonance [Internet]. 2024 Jun 1 [cited 2024 Apr 26];26(1):100995. Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S1097664724009864","DOI":"10.1016\/j.jocmr.2024.100995"},{"issue":"4","key":"2636_CR10","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2022-320810","volume":"110","author":"A Bhuva","year":"2024","unstructured":"Bhuva A, Charles-Edwards G, Ashmore J, Lipton A, Benbow M, Grainger D et al (2024) Joint British Society consensus recommendations for magnetic resonance imaging for patients with cardiac implantable electronic devices. Heart 110(4):e3","journal-title":"Heart"},{"issue":"7","key":"2636_CR11","doi-asserted-by":"publisher","first-page":"e97","DOI":"10.1016\/j.hrthm.2017.04.025","volume":"14","author":"JH Indik","year":"2017","unstructured":"Indik JH, Gimbel JR, Abe H, Alkmim-Teixeira R, Birgersdotter-Green U, Clarke GD et al (2017) 2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices. Heart Rhythm 14(7):e97-153","journal-title":"Heart Rhythm"},{"issue":"3","key":"2636_CR12","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1055\/s-0043-102029","volume":"189","author":"T Sommer","year":"2017","unstructured":"Sommer T, Bauer W, Fischbach K, Kolb C, Luechinger R, Wiegand U et al (2017) MR imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators. Rofo 189(3):204\u2013217","journal-title":"Rofo"},{"key":"2636_CR13","doi-asserted-by":"crossref","unstructured":"Kramer CM, Barkhausen J, Bucciarelli-Ducci C, Flamm SD, Kim RJ, Nagel E. Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update. J Cardiovasc Magn Reson [Internet]. 2020 Feb 24 [cited 2022 Jan 30];22:17. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC7038611\/","DOI":"10.1186\/s12968-020-00607-1"},{"issue":"1","key":"2636_CR14","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/s12968-020-00626-y","volume":"22","author":"V Holtstiege","year":"2020","unstructured":"Holtstiege V, Meier C, Bietenbeck M, Chatzantonis G, Florian A, K\u00f6be J et al (2020) Clinical experience regarding safety and diagnostic value of cardiovascular magnetic resonance in patients with a subcutaneous implanted cardioverter\/defibrillator (S-ICD) at 1.5 T. J Cardiovasc Magn Reson. 22(1):35","journal-title":"J Cardiovasc Magn Reson."},{"issue":"1","key":"2636_CR15","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1186\/1532-429X-15-55","volume":"15","author":"V Klinke","year":"2013","unstructured":"Klinke V, Muzzarelli S, Lauriers N, Locca D, Vincenti G, Monney P et al (2013) Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR registry: description and validation of standardized criteria. J Cardiovasc Magn Reson 15(1):55","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"2636_CR16","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1186\/s12968-020-00683-3","volume":"22","author":"N Kawel-Boehm","year":"2020","unstructured":"Kawel-Boehm N, Hetzel SJ, Ambale-Venkatesh B, Captur G, Francois CJ, Jerosch-Herold M et al (2020) Reference ranges (\u2018normal values\u2019) for cardiovascular magnetic resonance (CMR) in adults and children: 2020 update. J Cardiovasc Magn Reson 22(1):87","journal-title":"J Cardiovasc Magn Reson"},{"issue":"20","key":"2636_CR17","doi-asserted-by":"publisher","first-page":"6673","DOI":"10.3390\/jcm12206673","volume":"12","author":"A Barison","year":"2023","unstructured":"Barison A, Ricci F, Pavon AG, Muscogiuri G, Bisaccia G, Camastra G et al (2023) Cardiovascular magnetic resonance in patients with cardiac electronic devices: evidence from a multicenter study. J Clin Med 12(20):6673","journal-title":"J Clin Med"},{"key":"2636_CR18","doi-asserted-by":"crossref","unstructured":"Sasaki T, Hansford R, Zviman MM, Kolandaivelu A, Bluemke DA, Berger RD, et al. Quantitative Assessment of Artifacts on Cardiac Magnetic Resonance Imaging of Patients with Pacemakers and Implantable Cardioverter Defibrillators. Circ Cardiovasc Imaging [Internet]. 2011 Nov 1 [cited 2019 Aug 28];4(6):662\u201370. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3218212\/","DOI":"10.1161\/CIRCIMAGING.111.965764"},{"issue":"2","key":"2636_CR19","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.hrthm.2013.10.032","volume":"11","author":"SM Stevens","year":"2014","unstructured":"Stevens SM, Tung R, Rashid S, Gima J, Cote S, Pavez G et al (2014) Device artifact reduction for magnetic resonance imaging of patients with implantable cardioverter-defibrillators and ventricular tachycardia: late gadolinium enhancement correlation with electroanatomic mapping. Heart Rhythm 11(2):289\u2013298","journal-title":"Heart Rhythm"},{"key":"2636_CR20","doi-asserted-by":"crossref","unstructured":"Pavon AG, Porretta AP, Arangalage D, Domenichini G, Rutz T, Hugelshofer S, et al. (2023) Feasibility of adenosine stress cardiovascular magnetic resonance perfusion imaging in patients with MR-conditional transvenous permanent pacemakers and defibrillators. J Cardiovasc Magn Reson [Internet]. 2022 Jan 13 [cited 2023 Oct 27];24:9. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC8756706\/","DOI":"10.1186\/s12968-021-00842-0"},{"issue":"2","key":"2636_CR21","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1093\/ehjci\/jeac202","volume":"24","author":"T Pezel","year":"2023","unstructured":"Pezel T, Lacotte J, Horvilleur J, Toupin S, Hovasse T, Unterseeh T et al (2023) Safety, feasibility, and prognostic value of stress perfusion CMR in patients with MR-conditional pacemaker. Eur Heart J Cardiovasc Imaging 24(2):202\u2013211","journal-title":"Eur Heart J Cardiovasc Imaging"},{"issue":"10","key":"2636_CR22","doi-asserted-by":"publisher","first-page":"2127","DOI":"10.1111\/jce.15630","volume":"33","author":"L Miller","year":"2022","unstructured":"Miller L, Airapetov S, Pillai A, Kalahasty G, Ellenbogen KA, Gregory Hundley W et al (2022) Hemodynamic response and safety of vasodilator stress cardiovascular magnetic resonance in patients with permanent pacemakers or implantable cardioverter-defibrillators. J Cardiovasc Electrophysiol 33(10):2127\u20132135","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"9","key":"2636_CR23","doi-asserted-by":"publisher","first-page":"1051","DOI":"10.1093\/ehjci\/jex243","volume":"19","author":"S Hilbert","year":"2023","unstructured":"Hilbert S, Jahnke C, Loebe S, Oebel S, Weber A, Spampinato R et al (2023) Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: a device-dependent imaging strategy for improved image quality. Eur Heart J-Cardiovasc Imaging 19(9):1051\u201361. https:\/\/doi.org\/10.1093\/ehjci\/jex243","journal-title":"Eur Heart J-Cardiovasc Imaging"},{"issue":"2","key":"2636_CR24","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1002\/mrm.27458","volume":"81","author":"K Hong","year":"2019","unstructured":"Hong K, Collins JD, Knight BP, Carr JC, Lee DC, Kim D (2019) Wideband myocardial perfusion pulse sequence for imaging patients with a cardiac implantable electronic device. Magn Reson Med 81(2):1219\u20131228","journal-title":"Magn Reson Med"},{"issue":"2","key":"2636_CR25","doi-asserted-by":"publisher","DOI":"10.1148\/ryct.2020190114","volume":"2","author":"K Hong","year":"2020","unstructured":"Hong K, Collins JD, Freed BH, Fan L, Arai AE, Hsu LY et al (2020) Accelerated wideband myocardial perfusion pulse sequence with compressed sensing reconstruction for myocardial blood flow quantification in patients with a cardiac implantable electronic device. Radiol Cardiothorac Imaging 2(2):e190114","journal-title":"Radiol Cardiothorac Imaging"},{"key":"2636_CR26","doi-asserted-by":"crossref","unstructured":"Shah AD, Morris MA, Hirsh DS, Warnock M, Huang Y, Mollerus M, et al. (2018) Magnetic resonance imaging safety in nonconditional pacemaker and defibrillator recipients: A meta-analysis and systematic review. Heart Rhythm [Internet]. 2018 Jul 1 [cited 2023 Sep 26];15(7):1001\u20138. Available from: https:\/\/www.heartrhythmjournal.com\/article\/S1547-5271(18)30129-2\/fulltext","DOI":"10.1016\/j.hrthm.2018.02.019"},{"issue":"2","key":"2636_CR27","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1093\/europace\/euz343","volume":"22","author":"DA Munawar","year":"2020","unstructured":"Munawar DA, Chan JEZ, Emami M, Kadhim K, Khokhar K, O\u2019Shea C et al (2020) Magnetic resonance imaging in non-conditional pacemakers and implantable cardioverter-defibrillators: a systematic review and meta-analysis. Europace 22(2):288\u2013298","journal-title":"Europace"},{"key":"2636_CR28","doi-asserted-by":"crossref","unstructured":"Qu Z, Liu MB, Olcese R, Karagueuzian H, Garfinkel A, Chen PS, et al. R-on-T and the initiation of reentry revisited: Integrating old and new concepts. Heart Rhythm [Internet]. 2022 Aug 1 [cited 2023 Oct 27];19(8):1369\u201383. Available from: https:\/\/www.sciencedirect.com\/science\/article\/pii\/S1547527122016964","DOI":"10.1016\/j.hrthm.2022.03.1224"},{"issue":"2","key":"2636_CR29","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/j.jacc.2007.08.074","volume":"53","author":"X Ren","year":"2009","unstructured":"Ren X, Hongo RH (2009) Polymorphic ventricular tachycardia from R-on-T pacing. J Am Coll Cardiol 53(2):218","journal-title":"J Am Coll Cardiol"},{"issue":"6","key":"2636_CR30","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1016\/j.hrthm.2012.01.023","volume":"9","author":"PM Schulman","year":"2012","unstructured":"Schulman PM, Stecker EC, Rozner MA (2012) R-on-T and cardiac arrest from dual-chamber pacing without an atrial lead. Heart Rhythm 9(6):970\u2013973","journal-title":"Heart Rhythm"},{"issue":"1","key":"2636_CR31","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/s00392-006-0309-7","volume":"95","author":"B Nowak","year":"2006","unstructured":"Nowak B, Hemmer W, Israel CW, Kr\u00e4mer LI, Neuzner J, Pfeiffer D et al (2006) Statement of the working group of the Germany society on the safety of asynchronous ventricular pacemaker stimulation. Clin Res Cardiol 95(1):57\u201360","journal-title":"Clin Res Cardiol"},{"key":"2636_CR32","doi-asserted-by":"crossref","unstructured":"Klein-Wiele O, Garmer M, Barbone G, Urbien R, Busch M, Kara K, et al. (2017) Deactivation vs. asynchronous pacing - prospective evaluation of a protocol for rhythm management in patients with magnetic resonance conditional pacemakers undergoing adenosine stress cardiovascular magnetic resonance imaging. BMC Cardiovasc Disord [Internet]. 2017 Jun 2 [cited 2023 Oct 27];17:142. Available from: https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC5457583\/","DOI":"10.1186\/s12872-017-0579-1"},{"issue":"2","key":"2636_CR33","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1093\/europace\/euj038","volume":"8","author":"CW Israel","year":"2006","unstructured":"Israel CW (2006) The role of pacing mode in the development of atrial fibrillation. Europace 8(2):89\u201395","journal-title":"Europace"}],"container-title":["Clinical Research in Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00392-025-02636-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00392-025-02636-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00392-025-02636-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T10:58:25Z","timestamp":1744628305000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00392-025-02636-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,14]]},"references-count":33,"alternative-id":["2636"],"URL":"https:\/\/doi.org\/10.1007\/s00392-025-02636-1","relation":{},"ISSN":["1861-0684","1861-0692"],"issn-type":[{"type":"print","value":"1861-0684"},{"type":"electronic","value":"1861-0692"}],"subject":[],"published":{"date-parts":[[2025,4,14]]},"assertion":[{"value":"16 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Nothing to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. The study protocol was approved by the local ethics committee (Ethik-Kommission Westfalen-Lippe, Germany, Nr. 2023-128-f-S).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}