{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T22:31:11Z","timestamp":1772058671257,"version":"3.50.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2021,5,17]],"date-time":"2021-05-17T00:00:00Z","timestamp":1621209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,5,17]],"date-time":"2021-05-17T00:00:00Z","timestamp":1621209600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Herzschr Elektrophys"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1007\/s00399-021-00763-6","type":"journal-article","created":{"date-parts":[[2021,5,17]],"date-time":"2021-05-17T09:02:17Z","timestamp":1621242137000},"page":"236-243","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Newer generation cryoballoon vs. contact force-sensing radiofrequency ablation catheter in the ablation of paroxysmal atrial fibrillation","Kryoballon der neueren Generation vs. Radiofrequenzablationskatheter mit Anpressdruckmessung bei der Ablation von paroxysmalem Vorhofflimmern"],"prefix":"10.1007","volume":"32","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4323-6243","authenticated-orcid":false,"given":"Ahmed Nabil","family":"Ali","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Omar","family":"Riad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mazen","family":"Tawfik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aaisha","family":"Opel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tom","family":"Wong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,5,17]]},"reference":[{"issue":"4","key":"763_CR1","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1016\/j.hrthm.2011.12.016","volume":"9","author":"H Calkins","year":"2012","unstructured":"Calkins\u00a0H, Kuck\u00a0KH, Cappato\u00a0R, Brugada\u00a0J, Camm\u00a0AJ, Chen\u00a0SA, Crijns\u00a0HJ et al (2012) 2012 HRS\/EHRA\/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a\u00a0report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a\u00a0registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society. Heart Rhythm 9(4):632\u201396.e21","journal-title":"Heart Rhythm"},{"issue":"5","key":"763_CR2","doi-asserted-by":"publisher","first-page":"448.e1","DOI":"10.1016\/j.amjmed.2005.10.057","volume":"119","author":"G Thrall","year":"2006","unstructured":"Thrall\u00a0G, Lane\u00a0D, Carroll\u00a0D, Lip\u00a0GY (2006) Quality of life in patients with atrial fibrillation: a\u00a0systematic review. Am J Med 119(5):448.e1\u2013448.19","journal-title":"Am J Med"},{"issue":"5","key":"763_CR3","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1016\/j.ahj.2014.02.003","volume":"167","author":"BA Steinberg","year":"2014","unstructured":"Steinberg\u00a0BA, Kim\u00a0S, Fonarow\u00a0GC, Thomas\u00a0L, Ansell\u00a0J, Kowey\u00a0PR, Mahaffey\u00a0KW et al (2014) Drivers of hospitalization for patients with atrial fibrillation: Results from the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF). Am Heart\u00a0J 167(5):735\u2013742.e2","journal-title":"Am Heart J"},{"issue":"10","key":"763_CR4","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1056\/NEJM199809033391003","volume":"339","author":"M Ha\u00efssaguerre","year":"1998","unstructured":"Ha\u00efssaguerre\u00a0M, Ja\u00efs\u00a0P, Shah\u00a0DC, Takahashi\u00a0A, Hocini\u00a0M, Quiniou\u00a0G, Garrigue\u00a0S et\u00a0al (1998) Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N\u00a0Engl J Med 339(10):659\u2013666","journal-title":"N\u00a0Engl J Med"},{"issue":"21","key":"763_CR5","doi-asserted-by":"publisher","first-page":"2634","DOI":"10.1001\/jama.293.21.2634","volume":"293","author":"OM Wazni","year":"2005","unstructured":"Wazni\u00a0OM, Marrouche\u00a0NF, Martin\u00a0DO, Verma\u00a0A, Bhargava\u00a0M, Saliba\u00a0W, Bash\u00a0D et al (2005) Radiofrequency ablation vs antiarrhythmic drugs as first-line treatment of symptomatic atrial fibrillation: a\u00a0randomized trial. JAMA 293(21):2634\u20132640","journal-title":"JAMA"},{"issue":"11","key":"763_CR6","doi-asserted-by":"publisher","first-page":"2340","DOI":"10.1016\/j.jacc.2006.08.037","volume":"48","author":"C Pappone","year":"2006","unstructured":"Pappone\u00a0C, Augello\u00a0G, Sala\u00a0S, Gugliotta\u00a0F, Vicedomini\u00a0G, Gulletta\u00a0S, Paglino\u00a0G et\u00a0al (2006) A randomized trial of circumferential pulmonary vein ablation versus antiarrhythmic drug therapy in paroxysmal atrial fibrillation: the APAF Study. J\u00a0Am Coll Cardiol 48(11):2340\u20132347","journal-title":"J Am Coll Cardiol"},{"issue":"24","key":"763_CR7","doi-asserted-by":"publisher","first-page":"2498","DOI":"10.1161\/CIRCULATIONAHA.108.772582","volume":"118","author":"P Ja\u00efs","year":"2008","unstructured":"Ja\u00efs\u00a0P, Cauchemez\u00a0B, Macle\u00a0L, Daoud\u00a0E, Khairy\u00a0P, Subbiah\u00a0R, Hocini\u00a0M et\u00a0al (2008) Catheter ablation versus antiarrhythmic drugs for atrial fibrillation: the A4\u00a0study. Circulation 118(24):2498\u20132505","journal-title":"Circulation"},{"issue":"2","key":"763_CR8","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1093\/europace\/euu342","volume":"17","author":"H Walfridsson","year":"2015","unstructured":"Walfridsson\u00a0H, Walfridsson\u00a0U, Nielsen\u00a0JC, Johannessen\u00a0A, Raatikainen\u00a0P, Janzon\u00a0M, Levin\u00a0LA et al (2015) Radiofrequency ablation as initial therapy in paroxysmal atrial fibrillation: results on health-related quality of life and symptom burden. The MANTRA-PAF trial. Europace 17(2):215\u2013221","journal-title":"Europace"},{"issue":"7","key":"763_CR9","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.jacc.2014.04.072","volume":"64","author":"A Natale","year":"2014","unstructured":"Natale\u00a0A, Reddy\u00a0VY, Monir\u00a0G, Wilber\u00a0DJ, Lindsay\u00a0BD, McElderry\u00a0HT, Kantipudi\u00a0C et al (2014) Paroxysmal AF catheter ablation with a\u00a0contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J\u00a0Am Coll Cardiol 64(7):647\u2013656","journal-title":"J Am Coll Cardiol"},{"issue":"11","key":"763_CR10","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.1111\/j.1540-8159.2012.03503.x","volume":"35","author":"M Martinek","year":"2012","unstructured":"Martinek\u00a0M, Lemes\u00a0C, Sigmund\u00a0E, Derndorfer\u00a0M, Aichinger\u00a0J, Winter\u00a0S, Nesser\u00a0HJ et al (2012) Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation. Pacing Clin Electrophysiol 35(11):1312\u20131318","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"763_CR11","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1161\/CIRCEP.109.859116","volume":"3","author":"R Cappato","year":"2010","unstructured":"Cappato\u00a0R, Calkins\u00a0H, Chen\u00a0SA, Davies\u00a0W, Iesaka\u00a0Y, Kalman\u00a0J, Kim\u00a0YH et\u00a0al (2010) Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circ Arrhythm Electrophysiol 3(1):32\u201338","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"18","key":"763_CR12","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1093\/eurheartj\/ehm227","volume":"28","author":"Y Van Belle","year":"2007","unstructured":"Van Belle\u00a0Y, Janse\u00a0P, Rivero-Ayerza\u00a0MJ, Thornton\u00a0AS, Jessurun\u00a0ER, Theuns\u00a0D, Jordaens\u00a0L (2007) Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. Eur Heart\u00a0J 28(18):2231\u20132237","journal-title":"Eur Heart J"},{"issue":"23","key":"763_CR13","doi-asserted-by":"publisher","first-page":"2235","DOI":"10.1056\/NEJMoa1602014","volume":"374","author":"K-H Kuck","year":"2016","unstructured":"Kuck\u00a0K\u2011H, Brugada\u00a0J, F\u00fcrnkranz\u00a0A, Metzner\u00a0A, Ouyang\u00a0F, Chun\u00a0KR, Elvan\u00a0A et al (2016) Cryoballoon or radiofrequency ablation for paroxysmal atrial fibrillation. N\u00a0Engl J Med 374(23):2235\u20132245","journal-title":"N Engl J Med"},{"issue":"14","key":"763_CR14","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.1161\/CIRCULATIONAHA.115.016871","volume":"132","author":"A Luik","year":"2015","unstructured":"Luik\u00a0A, Radzewitz\u00a0A, Kieser\u00a0M, Walter\u00a0M, Bramlage\u00a0P, H\u00f6rmann\u00a0P, Schmidt\u00a0K et\u00a0al (2015) Cryoballoon versus open irrigated radiofrequency ablation in patients with paroxysmal atrial fibrillation. Circulation 132(14):1311\u20131319","journal-title":"Circulation"},{"issue":"12","key":"763_CR15","doi-asserted-by":"publisher","first-page":"1307","DOI":"10.1111\/jce.12846","volume":"26","author":"RJ Hunter","year":"2015","unstructured":"Hunter\u00a0RJ, Baker\u00a0V, Finlay\u00a0MC, Duncan\u00a0ER, Lovell\u00a0MJ, Tayebjee\u00a0MH, Ullah\u00a0W et al (2015) Point-by-point radiofrequency ablation versus the cryoballoon or a\u00a0novel combined approach: a randomized trial comparing 3 methods of pulmonary vein isolation for paroxysmal atrial fibrillation (the Cryo versus RF trial). J\u00a0Cardiovasc Electrophysiol 26(12):1307\u20131314","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"5","key":"763_CR16","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1093\/ejcts\/ezw313","volume":"50","author":"P Kirchhof","year":"2016","unstructured":"Kirchhof\u00a0P, Benussi\u00a0S, Kotecha\u00a0D, Ahlsson\u00a0A, Atar\u00a0D, Casadei\u00a0B, Castella\u00a0M et\u00a0al (2016) 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. Eur J Cardiothorac Surg 50(5):e1\u2013e88","journal-title":"Eur J Cardiothorac Surg"},{"issue":"7","key":"763_CR17","doi-asserted-by":"publisher","first-page":"1658","DOI":"10.1016\/j.hrthm.2015.03.021","volume":"12","author":"W Su","year":"2015","unstructured":"Su\u00a0W, Kowal\u00a0R, Kowalski\u00a0M, Metzner\u00a0A, Svinarich\u00a0JT, Wheelan\u00a0K, Wang\u00a0P (2015) Best practice guide for cryoballoon ablation in atrial fibrillation: The compilation experience of more than 3000 procedures. Heart Rhythm 12(7):1658\u20131666","journal-title":"Heart Rhythm"},{"issue":"21","key":"763_CR18","doi-asserted-by":"publisher","first-page":"2619","DOI":"10.1161\/01.CIR.102.21.2619","volume":"102","author":"C Pappone","year":"2000","unstructured":"Pappone\u00a0C, Rosanio\u00a0S, Oreto\u00a0G, Tocchi\u00a0M, Gugliotta\u00a0F, Vicedomini\u00a0G, Salvati\u00a0A et\u00a0al (2000) Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation. Circulation 102(21):2619\u20132628","journal-title":"Circulation"},{"issue":"4","key":"763_CR19","doi-asserted-by":"publisher","first-page":"141","DOI":"10.2459\/JCM.0000000000000633","volume":"19","author":"M Matta","year":"2018","unstructured":"Matta\u00a0M, Anselmino\u00a0M, Ferraris\u00a0F, Scaglione\u00a0M, Gaita\u00a0F (2018) Cryoballoon vs. radiofrequency contact force ablation for paroxysmal atrial fibrillation: a\u00a0propensity score analysis. J\u00a0Cardiovasc Med 19(4):141\u2013147","journal-title":"J Cardiovasc Med"},{"issue":"5","key":"763_CR20","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1093\/europace\/euv060","volume":"17","author":"F Squara","year":"2015","unstructured":"Squara\u00a0F, Zhao\u00a0A, Marijon\u00a0E, Latcu\u00a0DG, Providencia\u00a0R, Di Giovanni\u00a0G, Jauvert\u00a0G et al (2015) Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a\u00a0multicentre European evaluation. Europace 17(5):718\u2013724","journal-title":"Europace"},{"issue":"2","key":"763_CR21","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1111\/jce.13378","volume":"29","author":"M Yokokawa","year":"2018","unstructured":"Yokokawa\u00a0M, Chugh\u00a0A, Latchamsetty\u00a0R, Ghanbari\u00a0H, Crawford\u00a0T, Jongnarangsin\u00a0K, Cunnane\u00a0R et\u00a0al (2018) Ablation of paroxysmal atrial fibrillation using a\u00a0second-generation cryoballoon catheter or contact-force sensing radiofrequency ablation catheter: a\u00a0comparison of costs and long-term clinical outcomes. J Cardiovasc Electrophysiol 29(2):284\u2013290","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"6","key":"763_CR22","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1007\/s00392-018-1211-9","volume":"107","author":"TJ Buist","year":"2018","unstructured":"Buist\u00a0TJ, Adiyaman\u00a0A, Smit\u00a0JJJ, Ramdat Misier\u00a0AR, Elvan\u00a0A (2018) Arrhythmia-free survival and pulmonary vein reconnection patterns after second-generation cryoballoon and contact-force radiofrequency pulmonary vein isolation. Clin Res Cardiol 107(6):498\u2013506","journal-title":"Clin Res Cardiol"},{"issue":"2","key":"763_CR23","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1093\/europace\/euu215","volume":"17","author":"F Jourda","year":"2015","unstructured":"Jourda\u00a0F, Providencia\u00a0R, Marijon\u00a0E, Bouzeman\u00a0A, Hireche\u00a0H, Khoueiry\u00a0Z, Cardin\u00a0C et al (2015) Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation\u2014a prospective evaluation. Europace 17(2):225\u2013231","journal-title":"Europace"},{"issue":"10","key":"763_CR24","doi-asserted-by":"publisher","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","volume":"14","author":"H Calkins","year":"2017","unstructured":"Calkins\u00a0H, Hindricks\u00a0G, Cappato\u00a0R, Kim\u00a0YH, Saad\u00a0EB, Aguinaga\u00a0L, Akar\u00a0JG et\u00a0al (2017) 2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm 14(10):e275\u2013e444","journal-title":"Heart Rhythm"},{"key":"763_CR25","volume-title":"Real-world safety of catheter ablation for atrial fibrillation with contact force or cryoballoon ablation","author":"A Natale","year":"2020","unstructured":"Natale\u00a0A, Mohanty\u00a0S, Goldstein\u00a0L, Gomez\u00a0T, Hunter\u00a0TD (2020) Real-world safety of catheter ablation for atrial fibrillation with contact force or cryoballoon ablation"},{"issue":"2","key":"763_CR26","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1007\/s10840-015-0084-3","volume":"45","author":"F Straube","year":"2016","unstructured":"Straube\u00a0F, Dorwarth\u00a0U, Hartl\u00a0S, Bunz\u00a0B, Wankerl\u00a0M, Ebersberger\u00a0U, Hoffmann\u00a0E (2016) Outcome of paroxysmal atrial fibrillation ablation with the cryoballoon using two different application times: the 4\u2011 versus 3\u2011min protocol. J\u00a0Interv Card Electrophysiol 45(2):169\u2013177","journal-title":"J Interv Card Electrophysiol"}],"container-title":["Herzschrittmachertherapie + Elektrophysiologie"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00399-021-00763-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00399-021-00763-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00399-021-00763-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,31]],"date-time":"2021-05-31T12:09:57Z","timestamp":1622462997000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00399-021-00763-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,17]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["763"],"URL":"https:\/\/doi.org\/10.1007\/s00399-021-00763-6","relation":{},"ISSN":["0938-7412","1435-1544"],"issn-type":[{"value":"0938-7412","type":"print"},{"value":"1435-1544","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,17]]},"assertion":[{"value":"21 February 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A.N.\u00a0Ali, O.\u00a0Riad, M.\u00a0Tawfik, A.\u00a0Opel and T.\u00a0Wong declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants or on human tissue were in accordance with the ethical standards of the institutional (Ain Shams University ethical committee) and\/or national research committee and with the 1975 Helsinki declaration and its later amendments or comparable ethical standards. Informed consent was obtained from all individual participants included in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}