{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T17:47:14Z","timestamp":1782928034481,"version":"3.54.5"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T00:00:00Z","timestamp":1773100800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T00:00:00Z","timestamp":1773100800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Herzschr Elektrophys"],"published-print":{"date-parts":[[2026,6]]},"DOI":"10.1007\/s00399-026-01141-w","type":"journal-article","created":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T12:17:39Z","timestamp":1773145059000},"page":"125-138","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["\u00d6sophaguskomplikationen nach Katheterablation","Catheter ablation-induced esophageal complications"],"prefix":"10.1007","volume":"37","author":[{"given":"Philipp","family":"Halbfa\u00df","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Meinhardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,10]]},"reference":[{"issue":"2","key":"1141_CR1","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/j.gie.2024.08.036","volume":"101","author":"K Akiki","year":"2025","unstructured":"Akiki\u00a0K, Minteer\u00a0WB, Chandrasekhara\u00a0V, Mahmoud\u00a0T, Ryan\u00a0J, Law\u00a0RL et\u00a0al (2025) EUS for the evaluation of esophageal injury after catheter ablation for atrial fibrillation. Gastrointest Endosc 101(2):385\u2013390","journal-title":"Gastrointest Endosc"},{"issue":"2","key":"1141_CR2","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1016\/j.athoracsur.2023.04.016","volume":"116","author":"F Amirkhosravi","year":"2023","unstructured":"Amirkhosravi\u00a0F, Azimuddin\u00a0A, Nguyen\u00a0DT, Chihara\u00a0R, Chan\u00a0EY, Graviss\u00a0EA, Reul\u00a0RM, Kim\u00a0MP (2023) Surgical Treatment of Atrioesophageal Fistula: A Systematic Review. Ann Thorac Surg 116(2):421\u2013428. https:\/\/doi.org\/10.1016\/j.athoracsur.2023.04.016","journal-title":"Ann Thorac Surg"},{"issue":"12","key":"1141_CR3","doi-asserted-by":"publisher","first-page":"1862","DOI":"10.1016\/j.hrthm.2011.07.022","volume":"8","author":"FM Contreras-Valdes","year":"2011","unstructured":"Contreras-Valdes\u00a0FM, Heist\u00a0EK, Danik\u00a0SB, Barrett\u00a0CD, Blendea\u00a0D, Brugge\u00a0WR, Ptaszek\u00a0L, Ruskin\u00a0JN, Mansour\u00a0M (2011) Severity of esophageal injury predicts time to healing after radiofrequency catheter ablation for atrial fibrillation. Heart Rhythm O2 8(12):1862\u20131868. https:\/\/doi.org\/10.1016\/j.hrthm.2011.07.022","journal-title":"Heart Rhythm"},{"issue":"9","key":"1141_CR4","doi-asserted-by":"publisher","first-page":"2441","DOI":"10.1111\/jce.15168","volume":"32","author":"DG Della Rocca","year":"2021","unstructured":"Della Rocca\u00a0DG, Magnocavallo\u00a0M, Natale\u00a0VN, Gianni\u00a0C, Mohanty\u00a0S, Trivedi\u00a0C et\u00a0al (2021) Clinical presentation, diagnosis, and treatment of atrioesophageal fistula resulting from atrial fibrillation ablation. J\u00a0Cardiovasc Electrophysiol 32(9):2441\u20132450","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"11","key":"1141_CR5","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.118.006681","volume":"11","author":"T Deneke","year":"2018","unstructured":"Deneke\u00a0T, Nentwich\u00a0K, Berkovitz\u00a0A, Sonne\u00a0K, Ene\u00a0E, Pavlov\u00a0B, Fochler\u00a0F, B\u00f6tsch\u00a0AK, Kuhn\u00a0R, Halbfa\u00df\u00a0P (2018) High-Resolution Infrared Thermal Imaging of the Esophagus During Atrial Fibrillation Ablation as a\u00a0Predictor of Endoscopically Detected Thermal Lesions: Results From the HEAT-AF Study. Circ Arrhythm Electrophysiol 11(11):e006681. https:\/\/doi.org\/10.1161\/CIRCEP.118.006681","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"1141_CR6","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1016\/j.xjon.2024.09.010","volume":"22","author":"L Dupautet","year":"2024","unstructured":"Dupautet\u00a0L, Lebreton\u00a0G, Saiydoun\u00a0G, Bourguignon\u00a0T, Frey\u00a0S, Beaufreton\u00a0C, Galvaing\u00a0G, Cambier\u00a0S, Filaire\u00a0M, Filaire\u00a0L (2024) Surgical management of atrioesophageal fistula after catheter ablation of atrial fibrillation: A\u00a0French nationwide study. JTCVS Open 22:476\u2013484. https:\/\/doi.org\/10.1016\/j.xjon.2024.09.010","journal-title":"JTCVS Open"},{"issue":"4","key":"1141_CR7","doi-asserted-by":"publisher","first-page":"675","DOI":"10.1161\/CIRCEP.113.000384","volume":"6","author":"C Eitel","year":"2013","unstructured":"Eitel\u00a0C, Rolf\u00a0S, Zach\u00e4us\u00a0M, John\u00a0S, Sommer\u00a0P, Bollmann\u00a0A, Arya\u00a0A, Piorkowski\u00a0C, Hindricks\u00a0G, Halm\u00a0U (2013) Successful nonsurgical treatment of esophagopericardial fistulas after atrial fibrillation catheter ablation: a\u00a0case series. Circ Arrhythm Electrophysiol 6(4):675\u2013681. https:\/\/doi.org\/10.1161\/CIRCEP.113.000384","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"7","key":"1141_CR8","doi-asserted-by":"publisher","first-page":"2020","DOI":"10.1038\/s41591-024-03114-3","volume":"30","author":"E Ekanem","year":"2024","unstructured":"Ekanem\u00a0E, Neuzil\u00a0P, Reichlin\u00a0T, Kautzner\u00a0J, van der Voort\u00a0P, Jais\u00a0P et\u00a0al (2024) Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study. Nat Med 30(7):2020\u20132029. https:\/\/doi.org\/10.1038\/s41591-024-03114-3","journal-title":"Nat Med"},{"issue":"1","key":"1141_CR9","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1007\/s10840-008-9307-1","volume":"24","author":"KK Ghia","year":"2009","unstructured":"Ghia\u00a0KK, Chugh\u00a0A, Good\u00a0E, Pelosi\u00a0F, Jongnarangsin\u00a0K, Bogun\u00a0F, Morady\u00a0F, Oral\u00a0H (2009) A nationwide survey on the prevalence of atrioesophageal fistula after left atrial radiofrequency catheter ablation. J\u00a0Interv Card Electrophysiol 24(1):33\u201336","journal-title":"J Interv Card Electrophysiol"},{"issue":"8","key":"1141_CR10","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.117.005233","volume":"10","author":"P Halbfass","year":"2017","unstructured":"Halbfass\u00a0P, Pavlov\u00a0B, M\u00fcller\u00a0P, Nentwich\u00a0K, Sonne\u00a0K, Barth\u00a0S, Hamm\u00a0K, Fochler\u00a0F, M\u00fcgge\u00a0A, L\u00fcsebrink\u00a0U, Kuhn\u00a0R, Deneke\u00a0T (2017) Progression From Esophageal Thermal Asymptomatic Lesion to Perforation Complicating Atrial Fibrillation Ablation: A Single-Center Registry. Circ Arrhythm Electrophysiol 10(8):e005233. https:\/\/doi.org\/10.1161\/CIRCEP.117.005233","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"3","key":"1141_CR11","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1093\/europace\/euab261","volume":"24","author":"P Halbfass","year":"2022","unstructured":"Halbfass\u00a0P, Wielandts\u00a0JY, Knecht\u00a0S, Le Polain de Waroux\u00a0JB, Tavernier\u00a0R et\u00a0al (2022) Safety of very high-power short-duration radiofrequency ablation for pulmonary vein isolation: a two-centre report with emphasis on silent oesophageal injury. Europace 24(3):400\u2013405","journal-title":"Europace"},{"issue":"7","key":"1141_CR12","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1111\/jce.15553","volume":"33","author":"Y Ishidoya","year":"2022","unstructured":"Ishidoya\u00a0Y, Kwan\u00a0E, Dosdall\u00a0DJ, Macleod\u00a0RS, Navaravong\u00a0L, Steinberg\u00a0BA, Bunch\u00a0TJ, Ranjan\u00a0R (2022) Short-term natural course of esophageal thermal injury after ablation for atrial fibrillation. J\u00a0Cardiovasc Electrophysiol 33(7):1450\u20131459. https:\/\/doi.org\/10.1111\/jce.15553","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"11","key":"1141_CR13","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10112346","volume":"10","author":"DH Jung","year":"2021","unstructured":"Jung\u00a0DH, Yun\u00a0HR, Lee\u00a0SJ, Kim\u00a0NW, Huh\u00a0CW (2021) Endoscopic Vacuum Therapy in Patients with Transmural Defects of the Upper Gastrointestinal Tract: A Systematic Review with Meta-Analysis. J\u00a0Clin Med 10(11):2346. https:\/\/doi.org\/10.3390\/jcm10112346","journal-title":"J Clin Med"},{"issue":"10","key":"1141_CR14","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.120.008602","volume":"13","author":"T Kaneshiro","year":"2020","unstructured":"Kaneshiro\u00a0T, Kamioka\u00a0M, Hijioka\u00a0N, Yamada\u00a0S, Yokokawa\u00a0T, Misaka\u00a0T et\u00a0al (2020) Characteristics of Esophageal Injury in Ablation of Atrial Fibrillation Using a High-Power Short-Duration Setting. Circ Arrhythm Electrophysiol 13(10):e008602","journal-title":"Circ Arrhythm Electrophysiol"},{"issue":"10","key":"1141_CR15","doi-asserted-by":"publisher","first-page":"2190","DOI":"10.1016\/j.jacep.2025.05.021","volume":"11","author":"AA Kocharian","year":"2025","unstructured":"Kocharian\u00a0AA, Lador\u00a0A, Wang\u00a0S, Schurmann\u00a0PA, Dave\u00a0AS, Hong\u00a0TE, Chen\u00a0Q, Maffre\u00a0J, Sharma\u00a0T, Altmann\u00a0A, Beeckler\u00a0C, Valderr\u00e1bano\u00a0M (2025) Esophageal Heating and Damage With High-Power-Short-Duration Radiofrequency and Pulsed Field Ablation. JACC Clin Electrophysiol 11(10):2190\u20132201. https:\/\/doi.org\/10.1016\/j.jacep.2025.05.021","journal-title":"JACC Clin Electrophysiol"},{"issue":"2","key":"1141_CR16","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1093\/europace\/euaa276","volume":"23","author":"LWM Leung","year":"2021","unstructured":"Leung\u00a0LWM, Bajpai\u00a0A, Zuberi\u00a0Z, Li\u00a0A, Norman\u00a0M, Kaba\u00a0RA, Akhtar\u00a0Z, Evranos\u00a0B, Gonna\u00a0H, Harding\u00a0I, Sohal\u00a0M, Al-Subaie\u00a0N, Louis-Auguste\u00a0J, Hayat\u00a0J, Gallagher\u00a0MM (2021) Randomized comparison of oesophageal protection with a temperature control device: results of the IMPACT study. Europace 23(2):205\u2013215. https:\/\/doi.org\/10.1093\/europace\/euaa276","journal-title":"Europace"},{"issue":"1","key":"1141_CR17","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1111\/jce.15731","volume":"34","author":"S List","year":"2023","unstructured":"List\u00a0S, Meinhardt\u00a0C, Mueller\u00a0J, Deneke\u00a0T, Barth\u00a0S, Waechter\u00a0C, Luesebrink\u00a0U, Elsaesser\u00a0A, Arlt\u00a0A, Halbfass\u00a0P (2023) Incidence of ablation-induced esophageal lesions and gastroparesis in patients undergoing ablation index guided high power short duration atrial fibrillation ablation. J\u00a0Cardiovasc Electrophysiol 34(1):82\u201389. https:\/\/doi.org\/10.1111\/jce.15731","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"3","key":"1141_CR18","doi-asserted-by":"publisher","DOI":"10.14309\/crj.0000000000001650","volume":"12","author":"L Lushniak","year":"2025","unstructured":"Lushniak\u00a0L, Dharmadhikari\u00a0N, Zivari\u00a0K, Reyes Genere\u00a0JP, Kushnir\u00a0V, Bazarbashi\u00a0AN (2025) Endoscopic Vacuum Therapy for the Treatment of Atrial Fibrillation Ablation-Induced Esophageal Perforation. ACG Case Rep J 12(3):e01650. https:\/\/doi.org\/10.14309\/crj.0000000000001650","journal-title":"ACG Case Rep J"},{"issue":"6","key":"1141_CR19","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1111\/jce.12386","volume":"25","author":"S Mohanty","year":"2014","unstructured":"Mohanty\u00a0S, Santangeli\u00a0P, Mohanty\u00a0P, Di Biase\u00a0L, Trivedi\u00a0C, Bai\u00a0R, Horton\u00a0R, Burkhardt\u00a0JD, Sanchez\u00a0JE, Zagrodzky\u00a0J, Bailey\u00a0S, Gallinghouse\u00a0JG, Hranitzky\u00a0PM, Sun\u00a0AY, Hongo\u00a0R, Beheiry\u00a0S, Natale\u00a0A (2014) Outcomes of atrioesophageal fistula following catheter ablation of atrial fibrillation treated with surgical repair versus esophageal stenting. J\u00a0Cardiovasc Electrophysiol 25(6):579\u2013584. https:\/\/doi.org\/10.1111\/jce.12386","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"7","key":"1141_CR20","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.1016\/j.hrthm.2015.04.005","volume":"12","author":"P M\u00fcller","year":"2015","unstructured":"M\u00fcller\u00a0P, Dietrich\u00a0JW, Halbfass\u00a0P, Abouarab\u00a0A, Fochler\u00a0F, Sz\u00f6ll\u00f6si\u00a0A, Nentwich\u00a0K, Roos\u00a0M, Krug\u00a0J, Schade\u00a0A, M\u00fcgge\u00a0A, Deneke\u00a0T (2015) Higher incidence of esophageal lesions after ablation of atrial fibrillation related to the use of esophageal temperature probes. Heart Rhythm O2 12(7):1464\u20131469. https:\/\/doi.org\/10.1016\/j.hrthm.2015.04.005","journal-title":"Heart Rhythm"},{"issue":"2","key":"1141_CR21","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1007\/s10840-013-9853-z","volume":"39","author":"KK Nair","year":"2014","unstructured":"Nair\u00a0KK, Shurrab\u00a0M, Skanes\u00a0A, Danon\u00a0A, Birnie\u00a0D, Morillo\u00a0C et\u00a0al (2014) The prevalence and risk factors for atrioesophageal fistula after percutaneous radiofrequency catheter ablation for atrial fibrillation: the Canadian experience. J\u00a0Interv Card Electrophysiol 39(2):139\u2013144","journal-title":"J Interv Card Electrophysiol"},{"issue":"7","key":"1141_CR22","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.jacep.2019.04.009","volume":"5","author":"VY Reddy","year":"2019","unstructured":"Reddy\u00a0VY, Grimaldi\u00a0M, De Potter\u00a0T, Vijgen\u00a0JM, Bulava\u00a0A, Duytschaever\u00a0MF et\u00a0al (2019) Pulmonary Vein Isolation With Very High Power, Short Duration, Temperature-Controlled Lesions: The QDOT-FAST Trial. JACC Clin Electrophysiol 5(7):778\u2013786","journal-title":"JACC Clin Electrophysiol"},{"issue":"5","key":"1141_CR23","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1111\/pace.14972","volume":"47","author":"A Salihu","year":"2024","unstructured":"Salihu\u00a0A, Lu\u00a0H, Maurizi\u00a0N, Tzimas\u00a0G, Siklody C\u00a0H, Le Bloa\u00a0M, Domenichini\u00a0G, Teres\u00a0C, Hugelshofer\u00a0S, Monney\u00a0P, Pruvot\u00a0E, Muller\u00a0O, Antiochos\u00a0P, Pascale\u00a0P (2024) Prevention of esophageal lesions during atrial fibrillation catheter ablation using esophageal temperature monitoring: A systematic review and meta-analysis. Pacing Clin Electrophysiol 47(5):614\u2013625. https:\/\/doi.org\/10.1111\/pace.14972","journal-title":"Pacing Clin Electrophysiol"},{"issue":"12","key":"1141_CR24","doi-asserted-by":"publisher","first-page":"2558","DOI":"10.1016\/j.jacep.2023.08.022","volume":"9","author":"J Sanchez","year":"2023","unstructured":"Sanchez\u00a0J, Woods\u00a0C, Zagrodzky\u00a0J, Nazari\u00a0J, Singleton\u00a0MJ, Schricker\u00a0A et\u00a0al (2023) Atrioesophageal Fistula Rates Before and After Adoption of Active Esophageal Cooling During Atrial Fibrillation Ablation. JACC Clin Electrophysiol 9(12):2558\u20132570","journal-title":"JACC Clin Electrophysiol"},{"issue":"11","key":"1141_CR25","doi-asserted-by":"publisher","first-page":"1591","DOI":"10.1016\/j.hrthm.2013.08.012","volume":"10","author":"SM Singh","year":"2013","unstructured":"Singh\u00a0SM, d\u2019Avila\u00a0A, Singh\u00a0SK, Stelzer\u00a0P, Saad\u00a0EB, Skanes\u00a0A, Aryana\u00a0A, Chinitz\u00a0JS, Kulina\u00a0R, Miller\u00a0MA, Reddy\u00a0VY (2013) Clinical outcomes after repair of left atrial esophageal fistulas occurring after atrial fibrillation ablation procedures. Heart Rhythm O2 10(11):1591\u20131597. https:\/\/doi.org\/10.1016\/j.hrthm.2013.08.012","journal-title":"Heart Rhythm"},{"issue":"27","key":"1141_CR26","doi-asserted-by":"publisher","first-page":"2458","DOI":"10.1093\/eurheartj\/ehad250","volume":"44","author":"RR Tilz","year":"2023","unstructured":"Tilz\u00a0RR, Schmidt\u00a0V, P\u00fcrerfellner\u00a0H, Maury\u00a0P, Chun\u00a0KRJU, Martinek\u00a0M et\u00a0al (2023) A worldwide survey on incidence, management, and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: the POTTER-AF study. Eur Heart J 44(27):2458\u20132469","journal-title":"Eur Heart J"},{"issue":"1","key":"1141_CR27","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s10840-021-00960-w","volume":"63","author":"CM Tschabrunn","year":"2022","unstructured":"Tschabrunn\u00a0CM, Attalla\u00a0S, Salas\u00a0J, Frankel\u00a0DS, Hyman\u00a0MC, Simon\u00a0E et\u00a0al (2022) Active esophageal cooling for the prevention of thermal injury during atrial fibrillation ablation: a randomized controlled pilot study. J\u00a0Interv Card Electrophysiol 63(1):197\u2013205","journal-title":"J Interv Card Electrophysiol"},{"issue":"1","key":"1141_CR28","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.jacep.2023.09.004","volume":"10","author":"R Weiss","year":"2024","unstructured":"Weiss\u00a0R, Osorio\u00a0J, Nair\u00a0D, Aguinaga\u00a0L, Arabia\u00a0L, Alcivar\u00a0D, Al-Ahmad\u00a0A, Tomassoni\u00a0G, Kahaly\u00a0O, Mehta\u00a0R, Ward\u00a0C, Holmes\u00a0B, Patel\u00a0D, Killu\u00a0AM, Munger\u00a0T, Essandoh\u00a0M, Houmsse\u00a0M, Rajendra\u00a0A, Morales\u00a0G, Hummel\u00a0JD, Balasubramanian\u00a0G, Daoud\u00a0EG (2024) EsophAguS Deviation During RadiofrequencY Ablation of Atrial Fibrillation: The EASY AF Trial. JACC Clin Electrophysiol 10(1):68\u201378. https:\/\/doi.org\/10.1016\/j.jacep.2023.09.004","journal-title":"JACC Clin Electrophysiol"},{"issue":"2","key":"1141_CR29","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.hrthm.2018.09.027","volume":"16","author":"B Yarlagadda","year":"2019","unstructured":"Yarlagadda\u00a0B, Deneke\u00a0T, Turagam\u00a0M, Dar\u00a0T, Paleti\u00a0S, Parikh\u00a0V, DiBiase\u00a0L, Halfbass\u00a0P, Santangeli\u00a0P, Mahapatra\u00a0S, Cheng\u00a0J, Russo\u00a0A, Edgerton\u00a0J, Mansour\u00a0M, Ruskin\u00a0J, Dukkipati\u00a0S, Wilber\u00a0D, Reddy\u00a0V, Packer\u00a0D, Natale\u00a0A, Lakkireddy\u00a0D (2019) Temporal relationships between esophageal injury type and progression in patients undergoing atrial fibrillation catheter ablation. Heart Rhythm O2 16(2):204\u2013212. https:\/\/doi.org\/10.1016\/j.hrthm.2018.09.027","journal-title":"Heart Rhythm"}],"container-title":["Herzschrittmachertherapie + Elektrophysiologie"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00399-026-01141-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00399-026-01141-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00399-026-01141-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T17:04:43Z","timestamp":1782925483000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00399-026-01141-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,10]]},"references-count":29,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["1141"],"URL":"https:\/\/doi.org\/10.1007\/s00399-026-01141-w","relation":{},"ISSN":["0938-7412","1435-1544"],"issn-type":[{"value":"0938-7412","type":"print"},{"value":"1435-1544","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,10]]},"assertion":[{"value":"25 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Einhaltung ethischer Richtlinien"}},{"value":"P.\u00a0Halbfa\u00df und C.\u00a0Meinhardt geben an, dass kein Interessenkonflikt besteht.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}},{"value":"F\u00fcr diesen Beitrag wurden von den Autor\/-innen keine Studien an Menschen oder Tieren durchgef\u00fchrt. F\u00fcr die aufgef\u00fchrten Studien gelten die jeweils dort angegebenen ethischen Richtlinien.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Interessenkonflikt"}}]}}