{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T03:35:20Z","timestamp":1783481720351,"version":"3.55.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2005,1,12]],"date-time":"2005-01-12T00:00:00Z","timestamp":1105488000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2005,3]]},"DOI":"10.1007\/s00402-004-0772-4","type":"journal-article","created":{"date-parts":[[2005,1,11]],"date-time":"2005-01-11T11:36:49Z","timestamp":1105443409000},"page":"80-86","source":"Crossref","is-referenced-by-count":7,"title":["Five-year results of two cemented hip stem models each made of two different alloys"],"prefix":"10.1007","volume":"125","author":[{"given":"A.","family":"Schweizer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"L\ufffdem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"U.","family":"Riede","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Lindenlaub","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. E.","family":"Ochsner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2005,1,12]]},"reference":[{"key":"CR1","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1007\/s004020000254","volume":"121","author":"Acklin","year":"2001","unstructured":"Acklin YP, Berli BJ, Frick W, Elke R, Morscher EW (2001) Nine-year results of Muller cemented titanium straight stems in total hip replacement. Arch Orthop Trauma Surg 121:391?398","journal-title":"Arch Orthop Trauma Surg"},{"key":"CR2","doi-asserted-by":"crossref","first-page":"79","DOI":"10.5435\/00124635-199503000-00003","volume":"3","author":"Barrack","year":"1995","unstructured":"Barrack RL, Folgueras AJ (1995) Revision total hip arthroplasty: the femoral component. J Am Acad Orthop Surg 3:79?85","journal-title":"J Am Acad Orthop Surg"},{"key":"CR3","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1302\/0301-620X.83B5.10846","volume":"83","author":"Bowditch","year":"2001","unstructured":"Bowditch M, Villar R (2001) Is titanium so bad? Medium-term outcome of cemented titanium stems. J Bone Joint Surg Br 83:680?685","journal-title":"J Bone Joint Surg Br"},{"key":"CR4","doi-asserted-by":"crossref","first-page":"586","DOI":"10.2106\/00004623-200204000-00012","volume":"84","author":"Collis","year":"2002","unstructured":"Collis DK, Mohler CG (2002) Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry. J Bone Joint Surg Am 84:586?592","journal-title":"J Bone Joint Surg Am"},{"key":"CR5","doi-asserted-by":"crossref","first-page":"77","DOI":"10.2106\/00004623-199401000-00010","volume":"76","author":"Ebramzadeh","year":"1994","unstructured":"Ebramzadeh E, Sarmiento A, McKellop HA, Llinas A, Gogan W (1994) The cement mantle in total hip arthroplasty. Analysis of long-term radiographic results. J Bone Joint Surg Am 76:77?87","journal-title":"J Bone Joint Surg Am"},{"key":"CR6","doi-asserted-by":"crossref","first-page":"3351","DOI":"10.1016\/S0142-9612(03)00187-X","volume":"24","author":"Ebramzadeh","year":"2003","unstructured":"Ebramzadeh E, Normand PL, Sangiorgio SN, Llinas A, Gruen TA, McKellop HA, Sarmiento A (2003) Long-term radiographic changes in cemented total hip arthroplasty with six designs of femoral components. Biomaterials 24:3351?3363","journal-title":"Biomaterials"},{"key":"CR7","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.1007\/s001040170016","volume":"72","author":"Eggli","year":"2001","unstructured":"Eggli S, Holm J (2001) Implementation of a new electronic patient record in surgery (in German). Chirurg 72:1492?1500","journal-title":"Chirurg"},{"key":"CR8","first-page":"49","volume":"3","author":"Eingartner","year":"1997","unstructured":"Eingartner C, Volkmann R, Kummel K, Weller S (1997) Low loosening rate of a cemented titanium straight shaft prosthesis in long-term follow-up (in German). Swiss Surg 3:49?54","journal-title":"Swiss Surg"},{"key":"CR9","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/s002640100249","volume":"25","author":"Eingartner","year":"2001","unstructured":"Eingartner C, Volkmann R, Winter E, Maurer F, Ihm A, Weller S, Weise K (2001) Results of a cemented titanium alloy straight femoral shaft prosthesis after 10 years of follow-up. Int Orthop 25:81?84","journal-title":"Int Orthop"},{"key":"CR10","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1007\/s00113-002-0425-4","volume":"105","author":"Eingartner","year":"2002","unstructured":"Eingartner C, Ihm A, Maurer F, Volkmann R, Weise K, Weller S (2002) Good long term results with a cemented straight femoral shaft prosthesis made of titanium (in German). Unfallchirurg 105:804?810","journal-title":"Unfallchirurg"},{"key":"CR11","first-page":"17","volume":"141","author":"Gruen","year":"1979","unstructured":"Gruen TA, McNeice GM, Amstutz HC (1979) ?Modes of failure? of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 141:17?27","journal-title":"Clin Orthop"},{"key":"CR12","doi-asserted-by":"crossref","first-page":"573","DOI":"10.2106\/00004623-200204000-00010","volume":"84","author":"Harrington","year":"2002","unstructured":"Harrington MA Jr, O?Connor DO, Lozynsky AJ, Kovach I, Harris WH (2002) Effects of femoral neck length, stem size, and body weight on strains in the proximal cement mantle. J Bone Joint Surg Am 84:573?579","journal-title":"J Bone Joint Surg Am"},{"key":"CR13","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1055\/s-2000-10113","volume":"138","author":"Hinrichs","year":"2000","unstructured":"Hinrichs F, Boudriot U, Griss P (2000) 10\u00a0year results with a cemented fine-grit-blasted titanium-aluminum- vanadium hip endoprosthesis shaft (in German). Z Orthop 138:52?56","journal-title":"Z Orthop"},{"key":"CR14","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1054\/arth.2002.32697","volume":"17","author":"Jergesen","year":"2002","unstructured":"Jergesen HE, Karlen JW (2002) Clinical outcome in total hip arthroplasty using a cemented titanium femoral prosthesis. J Arthroplasty 17:592?599","journal-title":"J Arthroplasty"},{"key":"CR15","first-page":"33","volume":"68","author":"Kalairajah","year":"2002","unstructured":"Kalairajah Y, Molloy S, Patterson M (2002) The effect of femoral stem size on failure rates in total hip replacement cemented with Boneloc. Acta Orthop Belg 68:33?36","journal-title":"Acta Orthop Belg"},{"key":"CR16","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1016\/S1350-4533(03)00120-6","volume":"25","author":"Lennon","year":"2003","unstructured":"Lennon AB, McCormack BA, Prendergast PJ (2003) The relationship between cement fatigue damage and implant surface finish in proximal femoral prostheses. Med Eng Phys 25:833?841","journal-title":"Med Eng Phys"},{"key":"CR17","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1007\/s001130050652","volume":"103","author":"Lichtinger","year":"2000","unstructured":"Lichtinger TK, Schurmann N, Muller RT (2000) Early loosening of a cemented hip endoprosthesis stem of titanium (in German). Unfallchirurg 103:956?960","journal-title":"Unfallchirurg"},{"key":"CR18","unstructured":"Malchau H, Herberts P, Soderman P, Oden A (2000) Prognosis of total hip replacement. Results from the Swedish National Hip Arthroplasty Register. Scientific Exhibition, 67th AAOS Meeting, March 15?19, Orlando, USA"},{"key":"CR19","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1302\/0301-620X.79B4.7131","volume":"79","author":"Massoud","year":"1997","unstructured":"Massoud SN, Hunter JB, Holdsworth BJ, Wallace WA, Juliusson R (1997) Early femoral loosening in one design of cemented hip replacement. J Bone Joint Surg Br 79:603?608","journal-title":"J Bone Joint Surg Br"},{"key":"CR20","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1007\/s002640000219","volume":"25","author":"Maurer","year":"2001","unstructured":"Maurer TB, Ochsner PE, Schwarzer G, Schumacher M (2001) Increased loosening of cemented straight stem prostheses made from titanium alloys. An analysis and comparison with prostheses made of cobalt-chromium-nickel alloy. Int Orthop 25:77?80","journal-title":"Int Orthop"},{"key":"CR21","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1007\/s00264-002-0386-9","volume":"26","author":"Meek","year":"2002","unstructured":"Meek RM, Michos J, Grigoris P, Hamblen DL (2002) Mid-term results and migration behaviour of a Ti-alloy cemented stem. Int Orthop 26:356?360","journal-title":"Int Orthop"},{"key":"CR22","first-page":"305","volume":"80","author":"Osorovitz","year":"1994","unstructured":"Osorovitz P, Goutallier D (1994) Clinical and radiographic results of a continuous series of 124 type Ceraver-Osteal hip prostheses with a 9-year survival analysis (in French). Rev Chir Orthop Reparatrice Appar Mot 80:305?315","journal-title":"Rev Chir Orthop Reparatrice Appar Mot"},{"key":"CR23","doi-asserted-by":"crossref","first-page":"11","DOI":"10.3928\/0147-7447-19930101-03","volume":"16","author":"Paterson","year":"1993","unstructured":"Paterson D (1993) The International Documentation and Evaluation System (IDES). Orthopedics 16:11?14","journal-title":"Orthopedics"},{"key":"CR24","doi-asserted-by":"crossref","first-page":"846","DOI":"10.1007\/s001130050631","volume":"103","author":"Rader","year":"2000","unstructured":"Rader CP, Hendrich C, Low S, Walther M, Eulert J (2000) 5- to 8-year results of total hip endoprosthesis implantation with the Muller straight shaft prosthesis (cemented TiAlNb shaft) (in German). Unfallchirurg 103:846?852","journal-title":"Unfallchirurg"},{"key":"CR25","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/S0883-5403(89)80054-3","volume":"4","author":"Robinson","year":"1989","unstructured":"Robinson RP, Lovell TP, Green TM, Bailey GA (1989) Early femoral component loosening in DF-80 total hip arthroplasty. J Arthroplasty 4:55?64","journal-title":"J Arthroplasty"},{"key":"CR26","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1007\/s00264-003-0498-x","volume":"27","author":"Roder","year":"2003","unstructured":"Roder C, Eggli S, Muller U, Ambrose T, Roosli E, Busato A, Aebi M (2003) The International Documentation and Evaluation System (IDES)--10-years experience. Int Orthop 27:259?261","journal-title":"Int Orthop"},{"key":"CR27","doi-asserted-by":"crossref","first-page":"48","DOI":"10.2106\/00004623-198567010-00007","volume":"67","author":"Sarmiento","year":"1985","unstructured":"Sarmiento A, Gruen TA (1985) Radiographic analysis of a low-modulus titanium-alloy femoral total hip component. Two to six-year follow-up. J Bone Joint Surg Am 67:48?56","journal-title":"J Bone Joint Surg Am"},{"key":"CR28","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1054\/arth.2000.6618","volume":"15","author":"Scholl","year":"2000","unstructured":"Scholl E, Eggli S, Ganz R (2000) Osteolysis in cemented titanium alloy hip prosthesis. J Arthroplasty 15:570?575","journal-title":"J Arthroplasty"},{"key":"CR29","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/0883-5403(94)90063-9","volume":"9","author":"Star","year":"1994","unstructured":"Star MJ, Colwell CW Jr, Kelman GJ, Ballock RT, Walker RH (1994) Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization. J Arthroplasty 9:143?149","journal-title":"J Arthroplasty"},{"key":"CR30","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/0883-5403(94)90116-3","volume":"9","author":"Tompkins","year":"1994","unstructured":"Tompkins GS, Lachiewicz PF, DeMasi R (1994) A prospective study of a titanium femoral component for cemented total hip arthroplasty. J Arthroplasty 9:623?630","journal-title":"J Arthroplasty"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-004-0772-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-004-0772-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-004-0772-4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,3]],"date-time":"2021-07-03T21:51:46Z","timestamp":1625349106000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-004-0772-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,1,12]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2005,3]]}},"alternative-id":["772"],"URL":"https:\/\/doi.org\/10.1007\/s00402-004-0772-4","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,1,12]]}}}