{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T09:38:28Z","timestamp":1791538708018,"version":"4.3.4"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2005,11,1]],"date-time":"2005-11-01T00:00:00Z","timestamp":1130803200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2005,11]]},"DOI":"10.1007\/s00402-005-0004-6","type":"journal-article","created":{"date-parts":[[2005,8,22]],"date-time":"2005-08-22T10:56:50Z","timestamp":1124708210000},"page":"638-643","source":"Crossref","is-referenced-by-count":88,"title":["The high tibial osteotomy, open versus closed wedge, a comparison of methods in 108 patients"],"prefix":"10.1007","volume":"125","author":[{"given":"S.","family":"Hoell","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Suttmoeller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Stoll","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Fuchs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Gosheger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2005,11,15]]},"reference":[{"issue":"3","key":"4_CR1","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s00167-001-0250-2","volume":"10","author":"A Adili","year":"2002","unstructured":"Adili A et\u00a0al (2002) Valgus high tibial osteotomy. Comparison between an Ilizarov and a Coventry wedge technique for the treatment of medial compartment osteoarthritis of the knee. Knee Surg Sports Traumatol Arthrosc 10(3):169\u2013176","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"4_CR2","first-page":"21","volume":"16","author":"P Aglietti","year":"2003","unstructured":"Aglietti P et\u00a0al (2003) High tibial valgus osteotomy for medial gonarthrosis: a 10- to 21\u00a0year study. J Knee Surg 16(1):21\u201326","journal-title":"J Knee Surg"},{"issue":"4","key":"4_CR3","first-page":"203","volume":"16","author":"D Backstein","year":"2003","unstructured":"Backstein D, Meisami B, Gross AE (2003) Patella baja after the modified Coventry-Maquet high tibial osteotomy. J Knee Surg 16(4):203\u2013208","journal-title":"J Knee Surg"},{"key":"4_CR4","doi-asserted-by":"crossref","unstructured":"Berman AT et\u00a0al (1991) Factors influencing long-term results in high tibial osteotomy. Clin Orthop (272):192\u2013198","DOI":"10.1097\/00003086-199111000-00028"},{"issue":"1","key":"4_CR5","doi-asserted-by":"crossref","first-page":"70","DOI":"10.2106\/00004623-200001000-00009","volume":"82","author":"A Billings","year":"2000","unstructured":"Billings A et\u00a0al (2000) High tibial osteotomy with a calibrated osteotomy guide, rigid internal fixation, and early motion. Long-term follow-up. J Bone Joint Surg Am 82(1):70\u201379","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"4_CR6","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1007\/s007760100003","volume":"6","author":"HR Choi","year":"2001","unstructured":"Choi HR et\u00a0al (2001) High tibial osteotomy for varus gonarthrosis: a 10- to 24\u00a0year follow-up study. J Orthop Sci 6(6):493\u2013497","journal-title":"J Orthop Sci"},{"key":"4_CR7","doi-asserted-by":"crossref","first-page":"984","DOI":"10.2106\/00004623-196547050-00008","volume":"47","author":"MB Coventry","year":"1965","unstructured":"Coventry MB (1965) Osteotomy of the Upper Portion of the Tibia for Degenerative Arthritis of the Knee. A Preliminary Report. J Bone Joint Surg Am 47:984\u2013990","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"4_CR8","doi-asserted-by":"crossref","first-page":"196","DOI":"10.2106\/00004623-199302000-00006","volume":"75","author":"MB Coventry","year":"1993","unstructured":"Coventry MB, Ilstrup DM, Wallrichs SL (1993) Proximal tibial osteotomy. A critical long-term study of eighty-seven cases. J Bone Joint Surg Am 75(2):196\u2013201","journal-title":"J Bone Joint Surg Am"},{"issue":"7\u20138","key":"4_CR9","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1007\/s004020050019","volume":"119","author":"CH Flamme","year":"1999","unstructured":"Flamme CH et\u00a0al (1999) Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg 119(7\u20138):450\u2013455","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"4_CR10","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1007\/s00402-002-0446-z","volume":"123","author":"CH Flamme","year":"2003","unstructured":"Flamme CH et\u00a0al (2003) Long-term outcome following high tibial osteotomy with tension bend principle. Arch Orthop Trauma Surg 123(1):12\u201316","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"4_CR11","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1055\/s-2008-1037403","volume":"137","author":"S Fuchs","year":"1999","unstructured":"Fuchs S (1999) Value of alignment osteotomy of the proximal tibia in the endoprosthesis period. Z Orthop Ihre Grenzgeb 137(3):253\u2013258","journal-title":"Z Orthop Ihre Grenzgeb"},{"issue":"7\u20138","key":"4_CR12","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1007\/s004020050018","volume":"119","author":"EM Giagounidis","year":"1999","unstructured":"Giagounidis EM, Sell S (1999) High tibial osteotomy: factors influencing the duration of satisfactory function. Arch Orthop Trauma Surg 119(7\u20138):445\u2013449","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"4_CR13","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1054\/arth.2000.6621","volume":"15","author":"FS Haddad","year":"2000","unstructured":"Haddad FS, Bentley G (2000) Total knee arthroplasty after high tibial osteotomy: a medium-term review. J Arthroplasty 15(5):597\u2013603","journal-title":"J Arthroplasty"},{"key":"4_CR14","doi-asserted-by":"crossref","unstructured":"Hsu RW et\u00a0al (1990) Normal axial alignment of the lower extremity and load- bearing distribution at the knee. Clin Orthop (255):215\u2013227","DOI":"10.1097\/00003086-199006000-00029"},{"issue":"7","key":"4_CR15","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.2106\/00004623-197456070-00008","volume":"56","author":"J Insall","year":"1974","unstructured":"Insall J, Shoji H, Mayer V (1974) High tibial osteotomy. A five-year evaluation. J Bone Joint Surg Am 56(7):1397\u20131405","journal-title":"J Bone Joint Surg Am"},{"issue":"7","key":"4_CR16","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.2106\/00004623-198466070-00010","volume":"66","author":"JN Insall","year":"1984","unstructured":"Insall JN, Joseph DM, Msika C (1984) High tibial osteotomy for varus gonarthrosis. A long-term follow-up study. J Bone Joint Surg Am 66(7):1040\u20131048","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"4_CR17","doi-asserted-by":"crossref","first-page":"78","DOI":"10.2106\/00004623-200301000-00013","volume":"85-A","author":"T Koshino","year":"2003","unstructured":"Koshino T, Murase T, Saito T (2003) Medial opening-wedge high tibial osteotomy with use of porous hydroxyapatite to treat medial compartment osteoarthritis of the knee. J Bone Joint Surg Am 85-A(1):78\u201385","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"4_CR18","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s002640100244","volume":"25","author":"D Leutloff","year":"2001","unstructured":"Leutloff D, Tobian F, Perka C (2001) High tibial osteotomy for valgus and varus deformities of the knee. Int Orthop 25(2):93\u201396","journal-title":"Int Orthop"},{"issue":"3","key":"4_CR19","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1177\/036354658201000306","volume":"10","author":"J Lysholm","year":"1982","unstructured":"Lysholm J, Gillquist J (1982) Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale. Am J Sports Med 10(3):150\u2013154","journal-title":"Am J Sports Med"},{"issue":"3","key":"4_CR20","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1302\/0301-620X.81B3.8925","volume":"81","author":"G Magyar","year":"1999","unstructured":"Magyar G et\u00a0al (1999) Open-wedge osteotomy by hemicallotasis or the closed-wedge technique for osteoarthritis of the knee A randomised study of 50 operations. J Bone Joint Surg Br 81(3):444\u2013448","journal-title":"J Bone Joint Surg Br"},{"key":"4_CR21","doi-asserted-by":"crossref","unstructured":"Meding JB et\u00a0al (2000) Total knee arthroplasty after high tibial osteotomy. Clin Orthop (375):175\u201384","DOI":"10.1097\/00003086-200006000-00021"},{"issue":"8","key":"4_CR22","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1302\/0301-620X.83B8.11993","volume":"83","author":"E Nakamura","year":"2001","unstructured":"Nakamura E et\u00a0al (2001) Open-wedge osteotomy of the proximal tibia hemicallotasis. J Bone Joint Surg Br 83(8):1111\u20131115","journal-title":"J Bone Joint Surg Br"},{"key":"4_CR23","unstructured":"Naudie D et\u00a0al (1999) The Install Award. Survivorship of the high tibial valgus osteotomy. A 10- to \u221222\u00a0year followup study. Clin Orthop (367):18\u201327"},{"issue":"2","key":"4_CR24","doi-asserted-by":"crossref","first-page":"128","DOI":"10.3109\/17453679009006503","volume":"61","author":"S Odenbring","year":"1990","unstructured":"Odenbring S et\u00a0al (1990) Revision after osteotomy for gonarthrosis A 10\u201319\u00a0year follow-up of 314 cases. Acta Orthop Scand 61(2):128\u2013130","journal-title":"Acta Orthop Scand"},{"key":"4_CR25","doi-asserted-by":"crossref","unstructured":"Paley D (2002) In: Principles of Deformity Correction. Springer Verlag, Berlin Heidelberg New York","DOI":"10.1007\/978-3-642-59373-4"},{"issue":"1","key":"4_CR26","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1055\/s-2003-37294","volume":"141","author":"A Pascher","year":"2003","unstructured":"Pascher A, Materna W, Windhager R (2003) Analysis of two different techniques of osteosynthesis in high tibial osteotomy. Z Orthop Ihre Grenzgeb 141(1):37\u201341","journal-title":"Z Orthop Ihre Grenzgeb"},{"key":"4_CR27","doi-asserted-by":"crossref","unstructured":"Rinonapoli E et\u00a0al (1998) Tibial osteotomy for varus gonarthrosis. A 10- to 21\u00a0year followup study. Clin Orthop (353):185\u2013193","DOI":"10.1097\/00003086-199808000-00021"},{"issue":"3","key":"4_CR28","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/s00167-003-0344-0","volume":"11","author":"C Sen","year":"2003","unstructured":"Sen C, Kocaoglu M, Eralp L (2003) The advantages of circular external fixation used in high tibial osteotomy (average 6\u00a0years follow-up). Knee Surg Sports Traumatol Arthrosc 11(3):139\u2013144","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"4_CR29","doi-asserted-by":"crossref","unstructured":"Spahn G (2003) Complications in high tibial (medial opening wedge) osteotomy. Arch Orthop Trauma Surg, online first, DOI: 10.1007\/s00402-003-0588-7","DOI":"10.1007\/s00402-003-0588-7"},{"issue":"Suppl 2","key":"4_CR30","doi-asserted-by":"crossref","first-page":"B55","DOI":"10.1016\/j.injury.2003.09.025","volume":"34","author":"AE Staubli","year":"2003","unstructured":"Staubli AE et\u00a0al (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia\u2013early results in 92 cases. Injury 34(Suppl 2):B55\u2013B62","journal-title":"Injury"},{"key":"4_CR31","doi-asserted-by":"crossref","unstructured":"Tegner Y, Lysholm J (1985) Rating systems in the evaluation of knee ligament injuries. Clin Orthop (198):43\u20139","DOI":"10.1097\/00003086-198509000-00007"},{"issue":"6","key":"4_CR32","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s002640000173","volume":"24","author":"D Tigani","year":"2001","unstructured":"Tigani D et\u00a0al (2001) Patellar height after high tibial osteotomy. Int Orthop 24(6):331\u2013334","journal-title":"Int Orthop"},{"key":"4_CR33","doi-asserted-by":"crossref","unstructured":"Weale AE, Lee AS, MacEachern AG (2001) High tibial osteotomy using a dynamic axial external fixator. Clin Orthop (382):154\u2013167","DOI":"10.1097\/00003086-200101000-00022"},{"key":"4_CR34","doi-asserted-by":"crossref","unstructured":"Westrich GH et\u00a0al (1998) Patella height after high tibial osteotomy with internal fixation and early motion. Clin Orthop (354):169\u2013174","DOI":"10.1097\/00003086-199809000-00020"},{"issue":"3","key":"4_CR35","first-page":"163","volume":"14","author":"JM Wright","year":"2001","unstructured":"Wright JM et\u00a0al (2001) Observations on patellar height following opening wedge proximal tibial osteotomy. Am J Knee Surg 14(3):163\u2013173","journal-title":"Am J Knee Surg"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-005-0004-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-005-0004-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-005-0004-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T17:31:28Z","timestamp":1559064688000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-005-0004-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,11]]},"references-count":35,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2005,11]]}},"alternative-id":["4"],"URL":"https:\/\/doi.org\/10.1007\/s00402-005-0004-6","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,11]]}}}