{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T11:18:52Z","timestamp":1761823132895},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2009,2,4]],"date-time":"2009-02-04T00:00:00Z","timestamp":1233705600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2009,10]]},"DOI":"10.1007\/s00402-009-0823-y","type":"journal-article","created":{"date-parts":[[2009,2,3]],"date-time":"2009-02-03T09:47:49Z","timestamp":1233654469000},"page":"1375-1382","source":"Crossref","is-referenced-by-count":30,"title":["A new distractable implant for vertebral body replacement: biomechanical testing of four implants for the thoracolumbar spine"],"prefix":"10.1007","volume":"129","author":[{"given":"M.","family":"Reinhold","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W.","family":"Schmoelz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Canto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Krappinger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Blauth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Knop","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2009,2,4]]},"reference":[{"key":"823_CR1","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/00003086-197711000-00018","volume":"129","author":"GB Andersson","year":"1977","unstructured":"Andersson GB, \u00d6rtengren R, Nachemson A (1977) Intradiscal pressure, intraabdominal pressure and myoelectric back muscle activity related to posture and loading. Clin Orthop Relat Res 129:156\u2013164","journal-title":"Clin Orthop Relat Res"},{"issue":"9","key":"823_CR2","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1097\/00007632-199505000-00012","volume":"20","author":"JC Banwart","year":"1995","unstructured":"Banwart JC, Asher MA, Hassanein RS (1995) Iliac crest bone graft harvest donor site morbidity: a statistical evaluation. Spine 20(9):1055\u20131060. doi: 10.1097\/00007632-199505000-00012","journal-title":"Spine"},{"issue":"4","key":"823_CR3","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1007\/s00132-001-0285-6","volume":"31","author":"R Beisse","year":"2002","unstructured":"Beisse R, Potulski M, Beger J, Buhren V (2002) Development and clinical application of a thoracoscopy implantable plate frame for treatment of thoracolumbar fractures and instabilities. Orthopade 31(4):413\u2013422. doi: 10.1007\/s00132-001-0285-6","journal-title":"Orthopade"},{"issue":"8","key":"823_CR4","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1007\/s001130050315","volume":"101","author":"R Beisse","year":"1998","unstructured":"Beisse R, Potulski M, Temme C, Buhren V (1998) Endoscopically controlled division of the diaphragm: a minimally invasive approach to ventral management of thoracolumbar fractures of the spine. Unfallchirurg 101(8):619\u2013627. doi: 10.1007\/s001130050315","journal-title":"Unfallchirurg"},{"issue":"2","key":"823_CR5","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1007\/BF02678144","volume":"68","author":"C Bergot","year":"2001","unstructured":"Bergot C, Laval-Jeantet AM, Hutchinson K, Dautraix I, Caulin F, Genant HK (2001) A comparison of spinal quantitative computed tomography with dual energy X-ray absorptiometry in European women with vertebral and nonvertebral fractures. Calcif Tissue Int 68(2):74\u201382. doi: 10.1007\/BF02678144","journal-title":"Calcif Tissue Int"},{"issue":"5","key":"823_CR6","first-page":"437","volume":"26","author":"M Blauth","year":"1997","unstructured":"Blauth M, Knop C, Bastian L, Lobenhoffer P (1997) New developments in surgery of the injured spine. Orthopade 26(5):437\u2013449","journal-title":"Orthopade"},{"issue":"8","key":"823_CR7","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1097\/00007632-199306150-00010","volume":"18","author":"RF Closkey","year":"1993","unstructured":"Closkey RF, Parsons JR, Lee CK, Blacksin MF, Zimmerman MC (1993) Mechanics of interbody spinal fusion: analysis of critical bone graft area. Spine 18(8):1011\u20131015. doi: 10.1097\/00007632-199306150-00010","journal-title":"Spine"},{"issue":"21","key":"823_CR8","doi-asserted-by":"crossref","first-page":"2354","DOI":"10.1097\/00007632-199511000-00017","volume":"20","author":"VK Goel","year":"1995","unstructured":"Goel VK, Wilder DG, Pope MH, Edwards WT (1995) Biomechanical testing of the spine: load-controlled versus displacement-controlled analysis. Spine 20(21):2354\u20132357. doi: 10.1097\/00007632-199511000-00017","journal-title":"Spine"},{"key":"823_CR9","doi-asserted-by":"crossref","unstructured":"Goldhahn J, Reinhold M, Stauber M, Frei R, Schneider E, Linke B (2006) Improved anchorage in osteoporotic vertebrae with new implant designs. J Orthop Res (in press)","DOI":"10.1002\/jor.20133"},{"key":"823_CR10","doi-asserted-by":"crossref","unstructured":"Goulet JA, Senunas LE, DeSilva GL, Greenfield ML (1997) Autogenous iliac crest bone graft: complications and functional assessment. Clin Orthop Relat Res 339:76\u201381. doi: 10.1097\/00003086-199706000-00011","DOI":"10.1097\/00003086-199706000-00011"},{"issue":"2","key":"823_CR11","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1097\/00007632-198103000-00007","volume":"6","author":"T Hansson","year":"1981","unstructured":"Hansson T, Roos B (1981) The relation between bone mineral content, experimental compression fractures, and disc degeneration in lumbar vertebrae. Spine 6(2):147\u2013153. doi: 10.1097\/00007632-198103000-00007","journal-title":"Spine"},{"issue":"1","key":"823_CR12","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/00007632-198001000-00009","volume":"5","author":"T Hansson","year":"1980","unstructured":"Hansson T, Roos B, Nachemson A (1980) The bone mineral content and ultimate compressive strength of lumbar vertebrae. Spine 5(1):46\u201355. doi: 10.1097\/00007632-198001000-00009","journal-title":"Spine"},{"issue":"9","key":"823_CR13","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1097\/00007632-199605010-00007","volume":"21","author":"JP Hollowell","year":"1996","unstructured":"Hollowell JP, Vollmer DG, Wilson CR, Pintar FA, Yoganandan N (1996) Biomechanical analysis of thoracolumbar interbody constructs: how important is the endplate? Spine 21(9):1032\u20131036. doi: 10.1097\/00007632-199605010-00007","journal-title":"Spine"},{"issue":"4","key":"823_CR14","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1007\/s004649900987","volume":"13","author":"TJ Huang","year":"1999","unstructured":"Huang TJ, Hsu RW, Sum CW, Liu HP (1999) Complications in thoracoscopic spinal surgery: a study of 90 consecutive patients. Surg Endosc 13(4):346\u2013350. doi: 10.1007\/s004649900987","journal-title":"Surg Endosc"},{"issue":"15","key":"823_CR15","doi-asserted-by":"crossref","first-page":"1731","DOI":"10.1097\/00007632-199408000-00013","volume":"19","author":"KS James","year":"1994","unstructured":"James KS, Wenger KH, Schlegel JD, Dunn HK (1994) Biomechanical evaluation of the stability of thoracolumbar burst fractures. Spine 19(15):1731\u20131740. doi: 10.1097\/00007632-199408000-00013","journal-title":"Spine"},{"issue":"2","key":"823_CR16","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1007\/s005860050043","volume":"7","author":"B Jost","year":"1998","unstructured":"Jost B, Cripton PA, Lund T, Oxland TR et al (1998) Compressive strength of interbody cages in the lumbar spine: the effect of cage shape, posterior instrumentation and bone density. Eur Spine J 7(2):132\u2013141. doi: 10.1007\/s005860050043","journal-title":"Eur Spine J"},{"key":"823_CR17","first-page":"520","volume-title":"Handbuch der gesamten Unfallchirurgie, Band Bd. II","author":"H Junghanns","year":"1955","unstructured":"Junghanns H (1955) Wirbels\u00e4ule. In: Buerkle de la Camp H, Rostock P (eds) Handbuch der gesamten Unfallchirurgie, Band Bd. II. Enke, Stuttgart, pp 520\u2013564"},{"issue":"1 Suppl","key":"823_CR18","first-page":"91","volume":"99","author":"F Kandziora","year":"2003","unstructured":"Kandziora F, Pflugmacher R, Schaefer J, Scholz M et al (2003) Biomechanical comparison of expandable cages for vertebral body replacement in the cervical spine. J Neurosurg 99(1 Suppl):91\u201397","journal-title":"J Neurosurg"},{"issue":"8","key":"823_CR19","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1007\/s00113-002-0426-3","volume":"105","author":"C Karches","year":"2002","unstructured":"Karches C, Friedl W (2002) Secondary dislocations after Synex Cage implantation. Unfallchirurg 105(8):744\u2013747. doi: 10.1007\/s00113-002-0426-3","journal-title":"Unfallchirurg"},{"issue":"7","key":"823_CR20","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1007\/s001130170089","volume":"104","author":"C Knop","year":"2001","unstructured":"Knop C, Blauth M, Buhren V, Arand M et al (2001) Operative Behandlung von Verletzungen des thorakolumbalen \u00dcberganges\u2014Teil 3: Nachuntersuchung. Unfallchirurg 104(7):583\u2013600. doi: 10.1007\/s001130170089","journal-title":"Unfallchirurg"},{"issue":"3","key":"823_CR21","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s00586-001-0360-z","volume":"11","author":"C Knop","year":"2002","unstructured":"Knop C, Fabian HF, Bastian L, Rosenthal H et al (2002) Fate of the transpedicular intervertebral bone graft after posterior stabilisation of thoracolumbar fractures. Eur Spine J 11(3):251\u2013257. doi: 10.1007\/s00586-001-0360-z","journal-title":"Eur Spine J"},{"issue":"6","key":"823_CR22","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1007\/s005860000185","volume":"9","author":"C Knop","year":"2000","unstructured":"Knop C, Lange U, Bastian L, Blauth M (2000) Three-dimensional motion analysis with Synex: comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine. Eur Spine J 9(6):472\u2013485. doi: 10.1007\/s005860000185","journal-title":"Eur Spine J"},{"issue":"1","key":"823_CR23","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1007\/s005860000211","volume":"10","author":"C Knop","year":"2001","unstructured":"Knop C, Lange U, Bastian L, Oeser M, Blauth M (2001) Biomechanical compression tests with a new implant for thoracolumbar vertebral body replacement. Eur Spine J 10(1):30\u201337. doi: 10.1007\/s005860000211","journal-title":"Eur Spine J"},{"issue":"3","key":"823_CR24","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s00064-005-1132-4","volume":"17","author":"C Knop","year":"2005","unstructured":"Knop C, Lange U, Reinhold M, Blauth M (2005) Vertebral body replacement with Synex in combined posteroanterior surgery for treatment of thoracolumbar injuries. Oper Orthop Traumatol 17(3):249\u2013280. doi: 10.1007\/s00064-005-1132-4","journal-title":"Oper Orthop Traumatol"},{"issue":"5","key":"823_CR25","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/s00402-003-0486-z","volume":"123","author":"U Lange","year":"2003","unstructured":"Lange U, Knop C, Bastian L, Blauth M (2003) Prospective multicenter study with a new implant for thoracolumbar vertebral body replacement. Arch Orthop Trauma Surg 123(5):203\u2013208","journal-title":"Arch Orthop Trauma Surg"},{"key":"823_CR26","first-page":"127","volume-title":"Manual of internal fixation of the spine","author":"GL Lowery","year":"1996","unstructured":"Lowery GL, Harms J (1996) Titanium surgical mesh for vertebral defect replacement and intervertebral spacers. In: Thalgott J, Aebi M (eds) Manual of internal fixation of the spine. Lippincott & Raven, Philadelphia, pp 127\u2013146"},{"issue":"2","key":"823_CR27","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1302\/0301-620X.80B2.7693","volume":"80","author":"T Lund","year":"1998","unstructured":"Lund T, Oxland TR, Jost B, Cripton P et al (1998) Interbody cage stabilisation in the lumbar spine: biomechanical evaluation of cage design, posterior instrumentation and bone density. J Bone Joint Surg Br 80(2):351\u2013359. doi: 10.1302\/0301-620X.80B2.7693","journal-title":"J Bone Joint Surg Br"},{"issue":"8","key":"823_CR28","doi-asserted-by":"crossref","first-page":"1206","DOI":"10.2106\/00004623-198567080-00010","volume":"67","author":"RJ McBroom","year":"1985","unstructured":"McBroom RJ, Hayes WC, Edwards WT, Goldberg RP, White AAIII (1985) Prediction of vertebral body compressive fracture using quantitative computed tomography. J Bone Joint Surg Am 67(8):1206\u20131214","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"823_CR29","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1097\/00007632-198101000-00020","volume":"6","author":"AL Nachemson","year":"1981","unstructured":"Nachemson AL (1981) Disc pressure measurements. Spine 6(1):93\u201397. doi: 10.1097\/00007632-198101000-00020","journal-title":"Spine"},{"issue":"10","key":"823_CR30","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1097\/00007632-198810000-00013","volume":"13","author":"MM Panjabi","year":"1988","unstructured":"Panjabi MM (1988) Biomechanical evaluation of spinal fixation devices: I. A conceptual framework. Spine 13(10):1129\u20131134","journal-title":"Spine"},{"issue":"13","key":"823_CR31","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.1097\/01.BRS.0000129895.90939.1E","volume":"29","author":"R Pflugmacher","year":"2004","unstructured":"Pflugmacher R, Schleicher P, Schaefer J, Scholz M et al (2004) Biomechanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine. Spine 29(13):1413\u20131419. doi: 10.1097\/01.BRS.0000129895.90939.1E","journal-title":"Spine"},{"issue":"2","key":"823_CR32","first-page":"159","volume":"110","author":"R Plaue","year":"1972","unstructured":"Plaue R (1972) Behavior of thoracic and lumbar vertebral fractures: 1. Compression experiments on macerated vertebral bodies. Z Orthop Ihre Grenzgeb 110(2):159\u2013166","journal-title":"Z Orthop Ihre Grenzgeb"},{"key":"823_CR33","doi-asserted-by":"crossref","unstructured":"Reinhold M, Schmid R, Knop C, Blauth M (2004) Komplikationsspektrum operativ versorgter Wirbels\u00e4ulenverletzungen\u2014Eine Analyse der Multicenterstdien I und II der AG Wirbels\u00e4ule [Spectrum of complications involved in surgical management of spinal injuries\u2014analysis of two multicenter studies]. Trauma und Berufskrankheit","DOI":"10.1007\/s10039-004-0933-2"},{"issue":"4","key":"823_CR34","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1097\/01.brs.0000199894.63450.70","volume":"31","author":"M Reinhold","year":"2006","unstructured":"Reinhold M, Schwieger K, Goldhahn J, Linke B, Knop C, Blauth M (2006) Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae\u2014a biomechanical in vitro Study. Spine 31(4):406\u2013413. doi: 10.1097\/01.brs.0000199894.63450.70","journal-title":"Spine"},{"issue":"2","key":"823_CR35","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/BF02058659","volume":"3","author":"SD Rockoff","year":"1969","unstructured":"Rockoff SD, Sweet E, Bleustein J (1969) The relative contribution of trabecular and cortical bone to the strength of human lumbar vertebrae. Calcif Tissue Res 3(2):163\u2013175. doi: 10.1007\/BF02058659","journal-title":"Calcif Tissue Res"},{"issue":"8","key":"823_CR36","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1080\/00140130120943","volume":"44","author":"A Rohlmann","year":"2001","unstructured":"Rohlmann A, Claes LE, Bergmannt G, Graichen F, Neef P, Wilke HJ (2001) Comparison of intradiscal pressures and spinal fixator loads for different body positions and exercises. Ergonomics 44(8):781\u2013794. doi: 10.1080\/00140130110047657","journal-title":"Ergonomics"},{"issue":"23","key":"823_CR37","doi-asserted-by":"crossref","first-page":"2468","DOI":"10.1097\/00007632-199912010-00008","volume":"24","author":"K Sato","year":"1999","unstructured":"Sato K, Kikuchi S, Yonezawa T (1999) In vivo intradiscal pressure measurement in healthy individuals and in patients with ongoing back problems. Spine 24(23):2468\u20132474. doi: 10.1097\/00007632-199912010-00008","journal-title":"Spine"},{"issue":"19","key":"823_CR38","doi-asserted-by":"crossref","first-page":"2222","DOI":"10.1097\/00007632-199710010-00005","volume":"22","author":"CL Schnee","year":"1997","unstructured":"Schnee CL, Freese A, Weil RJ, Marcotte PJ (1997) Analysis of harvest morbidity and radiographic outcome using autograft for anterior cervical fusion. Spine 22(19):2222\u20132227. doi: 10.1097\/00007632-199710010-00005","journal-title":"Spine"},{"key":"823_CR39","doi-asserted-by":"crossref","first-page":"713","DOI":"10.2106\/00004623-198264050-00008","volume":"64","author":"AB Schultz","year":"1982","unstructured":"Schultz AB, Andersson GB, \u00d6rtengren R, Haderspeck K, Nachemson A (1982) Loads on the lumbar spine: validation of a biomechanical analysis by measurements of intradiscal pressure and myoelectric signals. J Bone Joint Surg Am 64:713\u2013720","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"823_CR40","first-page":"731","volume":"28","author":"D Stoltze","year":"1999","unstructured":"Stoltze D, Harms J (1999) Correction of posttraumatic deformities: principles and methods. Orthopade 28(8):731\u2013745","journal-title":"Orthopade"},{"issue":"6","key":"823_CR41","first-page":"265","volume":"21","author":"S Gumppenberg von","year":"1991","unstructured":"von Gumppenberg S, Vieweg J, Claudi B, Harms J (1991) Primary management of fresh injuries of the thoracic and lumbar vertebrae. Aktuelle Traumatol 21(6):265\u2013273","journal-title":"Aktuelle Traumatol"},{"key":"823_CR42","doi-asserted-by":"crossref","unstructured":"Whitesides TE (1977) Traumatic kyphosis of the thoracolumbar spine. Clin Orthop Relat Res 128:78\u201392","DOI":"10.1097\/00003086-197710000-00011"},{"issue":"4","key":"823_CR43","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1302\/0301-620X.83B4.9072","volume":"83","author":"HJ Wilke","year":"2001","unstructured":"Wilke HJ, Kemmerich V, Claes LE, Arand M (2001) Combined anteroposterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure. J Bone Joint Surg Br 83(4):609\u2013617. doi: 10.1302\/0301-620X.83B4.9072","journal-title":"J Bone Joint Surg Br"},{"issue":"8","key":"823_CR44","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1097\/00007632-199904150-00005","volume":"24","author":"HJ Wilke","year":"1999","unstructured":"Wilke HJ, Neef P, Caimi M, Hoogland T, Claes LE (1999) New in vivo measurements of pressures in the intervertebral disc in daily life. Spine 24(8):755\u2013762. doi: 10.1097\/00007632-199904150-00005","journal-title":"Spine"},{"issue":"2","key":"823_CR45","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1007\/s005860050045","volume":"7","author":"HJ Wilke","year":"1998","unstructured":"Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7(2):148\u2013154. doi: 10.1007\/s005860050045","journal-title":"Eur Spine J"},{"issue":"12","key":"823_CR46","doi-asserted-by":"crossref","first-page":"1286","DOI":"10.1007\/s001040050361","volume":"68","author":"BW Wippermann","year":"1997","unstructured":"Wippermann BW, Schratt HE, Steeg S, Tscherne H (1997) Complications of spongiosa harvesting of the ilial crest: a retrospective analysis of 1,191 cases. Chirurg 68(12):1286\u20131291. doi: 10.1007\/s001040050361","journal-title":"Chirurg"},{"issue":"10","key":"823_CR47","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1097\/00007632-199015100-00017","volume":"15","author":"RH Wittenberg","year":"1990","unstructured":"Wittenberg RH, Moeller J, Shea M, White AAIII, Hayes WC (1990) Compressive strength of autologous and allogenous bone grafts for thoracolumbar and cervical spine fusion. Spine 15(10):1073\u20131078. doi: 10.1097\/00007632-199015100-00017","journal-title":"Spine"},{"issue":"15","key":"823_CR48","doi-asserted-by":"crossref","first-page":"1736","DOI":"10.1097\/01.brs.0000172158.31437.ce","volume":"30","author":"C Woiciechowsky","year":"2005","unstructured":"Woiciechowsky C (2005) Distractable vertebral cages for reconstruction after cervical corpectomy. Spine 30(15):1736\u20131741. doi: 10.1097\/01.brs.0000172158.31437.ce","journal-title":"Spine"},{"issue":"3","key":"823_CR49","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1097\/00007632-199402000-00006","volume":"19","author":"L Wolfinbarger Jr","year":"1994","unstructured":"Wolfinbarger L Jr, Zhang Y, Adam BL, Sutherland V, Gates K, Brame B (1994) A comprehensive study of physical parameters, biomechanical properties, and statistical correlations of iliac crest bone wedges used in spinal fusion surgery: II. Mechanical properties and correlation with physical parameters. Spine 19(3):284\u2013295","journal-title":"Spine"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-009-0823-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-009-0823-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-009-0823-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T17:31:48Z","timestamp":1559064708000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-009-0823-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,2,4]]},"references-count":49,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2009,10]]}},"alternative-id":["823"],"URL":"https:\/\/doi.org\/10.1007\/s00402-009-0823-y","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,2,4]]}}}