{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T18:21:58Z","timestamp":1763662918630},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2011,8,4]],"date-time":"2011-08-04T00:00:00Z","timestamp":1312416000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2012,1]]},"DOI":"10.1007\/s00402-011-1364-8","type":"journal-article","created":{"date-parts":[[2011,8,3]],"date-time":"2011-08-03T18:38:15Z","timestamp":1312396695000},"page":"123-129","source":"Crossref","is-referenced-by-count":18,"title":["Cushion bearings versus large diameter head metal-on-metal bearings in total hip arthroplasty: a short-term metal ion study"],"prefix":"10.1007","volume":"132","author":[{"given":"Antonio","family":"Moroni","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emanuele","family":"Nocco","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martha","family":"Hoque","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elena","family":"Diremigio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dario","family":"Buffoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Cant\u00f9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simona","family":"Catalani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pietro","family":"Apostoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2011,8,4]]},"reference":[{"issue":"4","key":"1364_CR1","doi-asserted-by":"crossref","first-page":"780","DOI":"10.2106\/JBJS.F.00222","volume":"89","author":"S Kurtz","year":"2007","unstructured":"Kurtz S, Ong K, Lau E, Mowat F, Halpern M (2007) Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am 89(4):780\u2013785","journal-title":"J Bone Joint Surg Am"},{"key":"1364_CR2","first-page":"46","volume":"311","author":"WH Harris","year":"1995","unstructured":"Harris WH (1995) The problem is osteolysis. Clin Orthop Relat Res 311:46\u201353","journal-title":"Clin Orthop Relat Res."},{"key":"1364_CR3","doi-asserted-by":"crossref","unstructured":"Weber BG (1996) Experience with the Metasul total hip bearing system. Clin Orthop (329 Suppl):S69","DOI":"10.1097\/00003086-199608001-00007"},{"key":"1364_CR4","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/01.blo.0000193810.23706.73","volume":"441","author":"TM Smith","year":"2005","unstructured":"Smith TM, Berend KR, Lombardi AV, Emerson RH, Mallory TH (2005) Metal-on-metal hip arthroplasty with large heads may prevent early dislocation. Clin Orthop Rel Res 441:137\u2013142","journal-title":"Clin Orthop Rel Res"},{"issue":"1","key":"1364_CR5","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.arth.2004.07.008","volume":"20","author":"BR Burroughs","year":"2005","unstructured":"Burroughs BR, Hallstrom B, Golladay GJ, Hoeffel D, Harris WH (2005) Range of motion and stability in total hip arthroplasty with 28, 32, 38 and 44\u00a0mm femoral head sizes. J Arthroplasty 20(1):11\u201319","journal-title":"J Arthroplasty"},{"key":"1364_CR6","doi-asserted-by":"crossref","unstructured":"Cuckler JM, Moore KD, Lombardi AV, McPherson E, Emerson R (2004) Large versus small femoral heads in metal-on-metal total hip arthroplasty. J Arthroplasty 19(8 s3):41\u201344","DOI":"10.1016\/j.arth.2004.09.006"},{"key":"1364_CR7","doi-asserted-by":"crossref","first-page":"2456","DOI":"10.2106\/JBJS.D.02860","volume":"87","author":"DJ Berry","year":"2005","unstructured":"Berry DJ, von Klnoch M, Schleck CD, Harmsen WS (2005) Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg [Am] 87:2456\u20132463","journal-title":"J Bone Joint Surg [Am]"},{"key":"1364_CR8","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.arth.2008.06.015","volume":"23","author":"MJ Quesada","year":"2008","unstructured":"Quesada MJ, Marker DR, Mont MA (2008) Metal-on-metal hip resurfacing: advantages and disadvantages. J Arthroplasty 23:69\u201373","journal-title":"J Arthroplasty"},{"key":"1364_CR9","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.arth.2006.03.010","volume":"22","author":"MA Mont","year":"2007","unstructured":"Mont MA, Seyler TM, Ragland PS, Starr R, Erhart J, Bhave A (2007) Gait analysis of patients with resurfacing hip arthroplasty compared with hip osteoarthritis and standard total hip arthroplasty. J Arthroplasty 22:100\u2013108","journal-title":"J Arthroplasty"},{"key":"1364_CR10","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1002\/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.0.CO;2-M","volume":"42","author":"PF Doorn","year":"1998","unstructured":"Doorn PF, Campbell PA, Worrall J, Benya PD, McKellop HA, Amstutz HC (1998) Metal wear particle characterization from metal-on-metal total hip replacements: transmission electron microscopy study of periprosthetic tissues and isolated particles. J Biomed Mater Res 42:103\u2013111","journal-title":"J Biomed Mater Res"},{"key":"1364_CR11","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/01.blo.0000150309.48474.8b","volume":"429","author":"SJ MacDonald","year":"2004","unstructured":"MacDonald SJ (2004) Metal-on-metal total hip arthroplasty: the concerns. Clin Orthop. 429:86\u201393","journal-title":"Clin Orthop."},{"issue":"Suppl","key":"1364_CR12","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1097\/00003086-199608001-00025","volume":"329","author":"T Visuri","year":"1996","unstructured":"Visuri T, Pukkala E, Paavolainen P, Pulkkinen P, Riska EB (1996) Cancer risk after metal-on-metal and polyethylene-on-metal total hip arthroplasty. Clin Orthop 329(Suppl):280\u2013289","journal-title":"Clin Orthop"},{"issue":"3","key":"1364_CR13","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1177\/112070000801800304","volume":"18","author":"AJ Hart","year":"2008","unstructured":"Hart AJ, Buddhev P, Winship P, Faria N, Powell J, Skinner J (2008) Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing. Hip Int 18(3):212\u2013219","journal-title":"Hip Int"},{"issue":"6","key":"1364_CR14","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1007\/s11999-010-1636-6","volume":"469","author":"NM Desy","year":"2011","unstructured":"Desy NM, Bergeron SG, Petit A, Huk OL, Antoniou J (2011) Surgical variables influence metal ion levels after hip resurfacing. Clin Orthop Relat Res 469(6):1635\u20131641","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"1364_CR15","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1243\/095441105X9318","volume":"219","author":"SC Scholes","year":"2005","unstructured":"Scholes SC, Unsworth A, Blamey JM, Burgess IC, Jones E, Smith N (2005) Design aspects of compliant, soft layer bearings for an experimental hip prosthesis. Proc Inst Mech Eng H 219(2):79\u201387","journal-title":"Proc Inst Mech Eng H"},{"issue":"3","key":"1364_CR16","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1115\/1.3452605","volume":"97","author":"A Unsworth","year":"1975","unstructured":"Unsworth A, Dowson D, Wright V (1975) The frictional behaviour of human synovial joints\u2013Part 1: natural joints. Trans ASME J Lubr Technol 97(3):369\u2013376","journal-title":"Trans ASME J Lubr Technol"},{"issue":"11","key":"1364_CR17","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1002\/jor.20921","volume":"27","author":"JP Kretzer","year":"2009","unstructured":"Kretzer JP, Kleinhans JA, Jakubowitz E, Thomsen M, Heisel C (2009) A meta-analysis of design- and manufacturing-related parameters influencing the wear behaviour of metal-on-metal hip joint replacements. J Orthop Res 27(11):1473\u20131480","journal-title":"J Orthop Res"},{"key":"1364_CR18","doi-asserted-by":"crossref","unstructured":"Elsner JJ, Shemesh M, Mezape Y, Levenshtein M, Hakshur K, Shterling A, Linder-Ganz E, Eliaz N (2011) Long-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: a 20 million cycles wear simulation. J Orthop Res. doi: 10.1002\/jor.21471","DOI":"10.1002\/jor.21471"},{"key":"1364_CR19","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/00003086-199912000-00003","volume":"369","author":"FW Chan","year":"1999","unstructured":"Chan FW, Bobyn JD, Medley JB, Krygier JJ, Tanzer M (1999) Wear and lubrication of metal-on-metal hip implants. Clin Orthop 369:10\u201324","journal-title":"Clin Orthop"},{"issue":"3","key":"1364_CR20","doi-asserted-by":"crossref","first-page":"125","DOI":"10.2106\/JBJS.H.00437","volume":"90","author":"C Heisel","year":"2008","unstructured":"Heisel C, Streich N, Krachler M, Jakubowitz E, Kretzer JP (2008) Characterization of the running-in period in total hip resurfacing arthroplasty\u2014an in vivo and in vitro metal ion analysis. J Bone Joint Surg [Am] 90(3):125\u2013133","journal-title":"J Bone Joint Surg [Am]"},{"issue":"4","key":"1364_CR21","doi-asserted-by":"crossref","first-page":"737","DOI":"10.2106\/00004623-196951040-00012","volume":"51","author":"WH Harris","year":"1969","unstructured":"Harris WH (1969) Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg [Am] 51(4):737\u2013755","journal-title":"J Bone Joint Surg [Am]"},{"issue":"8","key":"1364_CR22","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1302\/0301-620X.89B8.19424","volume":"89","author":"DW Murray","year":"2007","unstructured":"Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ, Dawson J (2007) The use of the Oxford hip and knee scores. J Bone Joint Surg [Br] 89(8):1010\u20131014","journal-title":"J Bone Joint Surg [Br]"},{"key":"1364_CR23","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/0141-5425(89)90153-2","volume":"11","author":"PR Jones","year":"1989","unstructured":"Jones PR, Taylor CJ, Hukins DW, Porter ML, Hardinge K (1989) Prosthetic hip failure: retrospective radiograph image analysis of the acetabular cup. J Biomed Eng 11:253\u2013257","journal-title":"J Biomed Eng"},{"key":"1364_CR24","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.2106\/00004623-199711000-00004","volume":"79","author":"JM Martell","year":"1997","unstructured":"Martell JM, Berdia S (1997) Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg [Am] 79:1635\u20131641","journal-title":"J Bone Joint Surg [Am]"},{"key":"1364_CR25","doi-asserted-by":"crossref","first-page":"690","DOI":"10.2106\/00004623-199705000-00008","volume":"79","author":"SM Shaver","year":"1997","unstructured":"Shaver SM, Brown TD, Hillis SL, Callaghan JJ (1997) Digital edge-detection measurement of polyethylene wear after total hip arthroplasty. J Bone Joint Surg [Am]. 79:690\u2013700","journal-title":"J Bone Joint Surg [Am]."},{"issue":"8 Suppl 3","key":"1364_CR26","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.arth.2004.09.009","volume":"19","author":"SJ MacDonald","year":"2004","unstructured":"MacDonald SJ, Brodner W, Jacobs JJ (2004) A consensus paper on metal ions in metal-on-metal hip arthroplasties. J Arthroplasty 19(8 Suppl 3):12\u201316","journal-title":"J Arthroplasty"},{"key":"1364_CR27","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1243\/0954411001535381","volume":"214","author":"IC Clarke","year":"2000","unstructured":"Clarke IC, Good IV, Williams P, Schroeder D, Anissian L, Stark A, Oonishi H, Schuldies J, Gustafson G (2000) Ultra-low wear rates for rigid-on-rigid bearings in total hip replacement. Proc Inst Mech Eng H 214:331\u2013347","journal-title":"Proc Inst Mech Eng H"},{"key":"1364_CR28","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1302\/0301-620X.81B1.9047","volume":"81","author":"HP Sieber","year":"1999","unstructured":"Sieber HP, Rieker CB, K\u00f6ttig P (1999) Analysis of 118 second-generation metal-on-metal retrieved hip implants. J Bone Joint Surg [Br] 81:46\u201350","journal-title":"J Bone Joint Surg [Br]"},{"issue":"1","key":"1364_CR29","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1302\/0301-620X.78B1.0780018","volume":"78","author":"DN Kreibich","year":"1996","unstructured":"Kreibich DN, Moran CG, Delves HT, Owen TD, Pinder IM (1996) Systemic release of cobalt and chromium after total hip replacement. J Bone Joint Surg [Br] 78(1):18\u201321","journal-title":"J Bone Joint Surg [Br]"},{"issue":"10","key":"1364_CR30","doi-asserted-by":"crossref","first-page":"1447","DOI":"10.2106\/00004623-199810000-00006","volume":"80","author":"JJ Jacobs","year":"1998","unstructured":"Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J, Galante JO (1998) Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg [Am] 80(10):1447\u20131458","journal-title":"J Bone Joint Surg [Am]"},{"issue":"5","key":"1364_CR31","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1002\/jbm.10299","volume":"63","author":"L Savarino","year":"2002","unstructured":"Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A (2002) Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J Biomed Mater Res 63(5):467\u2013474","journal-title":"J Biomed Mater Res"},{"key":"1364_CR32","doi-asserted-by":"crossref","first-page":"472","DOI":"10.2106\/JBJS.E.00003","volume":"88","author":"L Savarino","year":"2006","unstructured":"Savarino L, Greco M, Cenni E, Cavasinni L, Rotini R, Baldini N, Giunti A (2006) Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. Medium-term follow-up. J Bone Joint Surg [Br] 88:472\u2013476","journal-title":"J Bone Joint Surg [Br]"},{"key":"1364_CR33","first-page":"94","volume":"319","author":"JJ Jacobs","year":"1995","unstructured":"Jacobs JJ, Urban RM, Gilbert JL, Skipor AK, Black J, Jasty M, Galante JO (1995) Local and distant products from modularity. Clin Orthop 319:94\u2013105","journal-title":"Clin Orthop"},{"key":"1364_CR34","doi-asserted-by":"crossref","first-page":"2168","DOI":"10.2106\/00004623-200311000-00017","volume":"85","author":"W Brodner","year":"2003","unstructured":"Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsaumer-Wolf F, Kotz R (2003) Elevated serum cobalt with metal-on-metal articulating surfaces. J Bone Joint Surg [Am] 85:2168\u20132173","journal-title":"J Bone Joint Surg [Am]"},{"issue":"3","key":"1364_CR35","doi-asserted-by":"crossref","first-page":"142","DOI":"10.2106\/JBJS.H.00442","volume":"90","author":"J Antoniou","year":"2008","unstructured":"Antoniou J, Zukor DJ, Mwale F, Minarik W, Petit A, Huk OL (2008) Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six millimeter-head metal-on-metal prostheses. J Bone Joint Surg [Am] 90(3):142\u2013148","journal-title":"J Bone Joint Surg [Am]"},{"issue":"2","key":"1364_CR36","doi-asserted-by":"crossref","first-page":"128","DOI":"10.2106\/JBJS.J.01885","volume":"93","author":"M Lavigne","year":"2011","unstructured":"Lavigne M, Belzile EL, Roy A, Morin F, Amzica T, Vendittoli PA (2011) Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve. J Bone Joint Surg [Am] 93(2):128\u2013136","journal-title":"J Bone Joint Surg [Am]"},{"issue":"6","key":"1364_CR37","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1007\/s00264-009-0729-x","volume":"33","author":"JP Kretzer","year":"2009","unstructured":"Kretzer JP, Jakubowitz E, Krachler M, Thomsen M, Heisel C (2009) Metal release and corrosion effects of modular neck total hip arthroplasty. Int Orthop 33(6):1531\u20131536","journal-title":"Int Orthop"},{"issue":"1","key":"1364_CR38","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1002\/jab.770060104","volume":"6","author":"SA Brown","year":"1995","unstructured":"Brown SA, Flemming CA, Kawalec JS, Placko HE, Vassaux C, Merritt K, Payer JH, Kraay MJ (1995) Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater 6(1):19\u201326","journal-title":"J Appl Biomater"},{"issue":"2","key":"1364_CR39","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1007\/s11999-009-1029-x","volume":"468","author":"DS Garbuz","year":"2010","unstructured":"Garbuz DS, Tanzer M, Greidanus NV, Masri BA, Duncan CP (2010) The John Charnley Award: metal-on-metal hip resurfacing versus large-diameter head metal-on-metal hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res 468(2):318\u2013325","journal-title":"Clin Orthop Relat Res"},{"key":"1364_CR40","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1302\/0301-620X.89B4.18054","volume":"89","author":"PA Vendittoli","year":"2007","unstructured":"Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M (2007) Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg [Br] 89:441\u2013448","journal-title":"J Bone Joint Surg [Br]"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-011-1364-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-011-1364-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-011-1364-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,13]],"date-time":"2019-06-13T18:18:22Z","timestamp":1560449902000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-011-1364-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,8,4]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,1]]}},"alternative-id":["1364"],"URL":"https:\/\/doi.org\/10.1007\/s00402-011-1364-8","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,8,4]]}}}