{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T11:45:06Z","timestamp":1790077506231,"version":"4.0.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2013,4,30]],"date-time":"2013-04-30T00:00:00Z","timestamp":1367280000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2013,7]]},"DOI":"10.1007\/s00402-013-1755-0","type":"journal-article","created":{"date-parts":[[2013,4,30]],"date-time":"2013-04-30T16:10:44Z","timestamp":1367338244000},"page":"893-899","source":"Crossref","is-referenced-by-count":81,"title":["A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine"],"prefix":"10.1007","volume":"133","author":[{"given":"Matjaz","family":"Merc","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Igor","family":"Drstvensek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matjaz","family":"Vogrin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomaz","family":"Brajlih","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregor","family":"Recnik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2013,4,30]]},"reference":[{"issue":"6","key":"1755_CR1","doi-asserted-by":"crossref","first-page":"715","DOI":"10.4103\/0028-3886.59465","volume":"57","author":"TA Mattei","year":"2009","unstructured":"Mattei TA, Meneses MS, Milano JB, Ramina R (2009) \u201cFree-hand\u201d technique for thoracolumbar pedicle screw instrumentation: critical appraisal of current \u201cstate-of-art\u201d. Neurol India 57(6):715\u2013721","journal-title":"Neurol India"},{"key":"1755_CR2","doi-asserted-by":"crossref","first-page":"458","DOI":"10.4103\/0028-3886.22613","volume":"53","author":"SC Zeiller","year":"2005","unstructured":"Zeiller SC, Lee J, Lim M, Vaccaro AR (2005) Posterior thoracic segmental pedicle screw instrumentation: evolving methods of safe and effective placement. Neurol India 53:458\u2013465","journal-title":"Neurol India"},{"key":"1755_CR3","first-page":"463","volume":"26","author":"U Berlemann","year":"1997","unstructured":"Berlemann U, Langlotz F, Langlotz U, Nolte LP (1997) Computer-assisted orthopedic surgery. From pedicle screw insertion to further applications. Orthopade 26:463\u2013469","journal-title":"Orthopade"},{"key":"1755_CR4","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1007\/s00586-006-0109-9","volume":"16","author":"PJ Richards","year":"2007","unstructured":"Richards PJ, Kurta IC, Jasani V, Jones CH, Rahmatalla A, Mackenzie G et al (2007) Assessment of CAOS as a training model in spinal surgery: a randomised study. Eur Spine J 16:239\u2013244","journal-title":"Eur Spine J"},{"key":"1755_CR5","first-page":"771","volume":"48","author":"AS Youkilis","year":"2001","unstructured":"Youkilis AS, Quint DJ, McGillicuddy JE, Papadoupoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771\u2013778","journal-title":"Neurosurgery"},{"issue":"5","key":"1755_CR6","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1302\/0301-620X.81B5.10370","volume":"81","author":"SP Hughes","year":"1999","unstructured":"Hughes SP, Anderson FM (1999) Infection in the operating room. J Bone Jt Surg Br 81(5):754\u2013755","journal-title":"J Bone Jt Surg Br"},{"issue":"15","key":"1755_CR7","doi-asserted-by":"crossref","first-page":"1793","DOI":"10.1097\/01.brs.0000171905.38459.b7","volume":"30","author":"MR Lim","year":"2005","unstructured":"Lim MR, Girardi FP, Yoon SC et al (2005) Accuracy of computerized frameless stereotactic image-guided pedicle screw placement into previously fused lumbar spines. Spine 30(15):1793\u20131798","journal-title":"Spine"},{"issue":"17","key":"1755_CR8","doi-asserted-by":"crossref","first-page":"2013","DOI":"10.1097\/01.BRS.0000087851.51547.00","volume":"28","author":"HC Sagi","year":"2003","unstructured":"Sagi HC, Manos R, Benz R et al (2003) Electromagnetic field-based image-guided spine surgery, part 1: results of a cadaveric study evaluating lumbar pedicle screw placement. Spine 28(17):2013\u20132018","journal-title":"Spine"},{"issue":"4","key":"1755_CR9","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/00007632-200102150-00012","volume":"26","author":"K Birnbaum","year":"2001","unstructured":"Birnbaum K, Schkommodau E, Decker N, Prescher A, Klapper U, Radermacher K (2001) Computer-assisted orthopaedic surgery with individual templates and comparison to conventional operation method. Spine 26(4):365\u2013369","journal-title":"Spine"},{"key":"1755_CR10","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/00003086-199809000-00005","volume":"354","author":"K Radermacher","year":"1998","unstructured":"Radermacher K, Portheine F, Anton M, Zimolong A, Kaspers G, Rau G, Staudte HW (1998) Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 354:28\u201338","journal-title":"Clin Orthop Relat Res"},{"key":"1755_CR11","first-page":"347","volume":"2","author":"K Brussel Van","year":"1998","unstructured":"Van Brussel K, Vander SJ, van Audekercke R, Swaelens B, Vanden Berghe L, Fabry G (1998) A medical image based template for pedicle screw insertion. Comput Methods Biomech Biomed Eng 2:347\u2013354","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"2","key":"1755_CR12","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1243\/095441105X9273","volume":"219","author":"E Berry","year":"2005","unstructured":"Berry E, Cuppone M, Porada S, Millner PA, Rao A, Chiverton N, Seedhom BB (2005) Personalised image-based templates for intra-operative guidance. Proc Inst Mech Eng H 219(2):111\u2013118","journal-title":"Proc Inst Mech Eng H"},{"issue":"12","key":"1755_CR13","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1097\/00007632-200106150-00017","volume":"26","author":"J Goffin","year":"2001","unstructured":"Goffin J, Van Brussel K, Martens K, Vander Sloten J, Van Audekercke R, Smet MH (2001) Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1\u2013C2. Spine 26(12):1343\u20131347","journal-title":"Spine"},{"issue":"5","key":"1755_CR14","doi-asserted-by":"crossref","first-page":"303","DOI":"10.3109\/10929080701662826","volume":"12","author":"BD Owen","year":"2007","unstructured":"Owen BD, Christensen GE, Reinhardt JM, Ryken TC (2007) Rapid prototype patient-specific drill template for cervical pedicle screw placement. Comput Aided Surg 12(5):303\u2013308","journal-title":"Comput Aided Surg"},{"issue":"2","key":"1755_CR15","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1002\/rcs.249","volume":"5","author":"S Lu","year":"2009","unstructured":"Lu S, Xu YQ, Zhang YZ, Li YB, Xie L, Shi JH et al (2009) A novel computer-assisted drill guide template for lumbar pedicle screw placement: a cadaveric and clinical study. Int J Med Robot 5(2):184\u2013191","journal-title":"Int J Med Robot"},{"issue":"1","key":"1755_CR16","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s00402-011-1383-5","volume":"132","author":"T Ma","year":"2012","unstructured":"Ma T, Xu YQ, Cheng YB, Jiang MY, Xu XM, Xie L, Lu S (2012) A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study. Arch Orthop Trauma Surg 132(1):65\u201372","journal-title":"Arch Orthop Trauma Surg"},{"issue":"7","key":"1755_CR17","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1007\/s11517-012-0900-1","volume":"50","author":"S Lu","year":"2012","unstructured":"Lu S, Zhang YZ, Wang Z, Shi JH, Chen YB, Xu XM, Xu YQ (2012) Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template. Med Biol Eng Comput 50(7):751\u2013758","journal-title":"Med Biol Eng Comput"},{"key":"1755_CR18","first-page":"29","volume":"1","author":"I Drstvensek","year":"2008","unstructured":"Drstvensek I, Ihan Hren N, Strojnik T, Brajlih T, Valentan B, Pogacar V, Zupancic Hartner T (2008) Applications of rapid prototyping in cranio-maxilofacial surgery procedures. Int J Biol Biomed Eng 1:29\u201338","journal-title":"Int J Biol Biomed Eng"},{"issue":"5","key":"1755_CR19","doi-asserted-by":"crossref","first-page":"503","DOI":"10.3171\/2009.11.SPINE09408","volume":"12","author":"LB Brasiliense","year":"2010","unstructured":"Brasiliense LB, Theodore N, Lazaro BC, Sayed ZA, Deniz FE, Sonntag VK, Crawford NR (2010) Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost? J Neurosurg Spine 12(5):503\u2013508","journal-title":"J Neurosurg Spine"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-013-1755-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-013-1755-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-013-1755-0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,28]],"date-time":"2019-05-28T13:35:44Z","timestamp":1559050544000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-013-1755-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,4,30]]},"references-count":19,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2013,7]]}},"alternative-id":["1755"],"URL":"https:\/\/doi.org\/10.1007\/s00402-013-1755-0","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,4,30]]}}}