{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T21:59:01Z","timestamp":1761947941538},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2014,5,18]],"date-time":"2014-05-18T00:00:00Z","timestamp":1400371200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1007\/s00402-014-2005-9","type":"journal-article","created":{"date-parts":[[2014,5,17]],"date-time":"2014-05-17T06:56:19Z","timestamp":1400309779000},"page":"1009-1015","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["MRI does not detect acetabular osteolysis around metal-on-metal Birmingham THA"],"prefix":"10.1007","volume":"134","author":[{"given":"Wenzel","family":"Waldstein","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tom","family":"Schmidt-Braekling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Friedrich","family":"Boettner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2014,5,18]]},"reference":[{"issue":"2","key":"2005_CR1","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1302\/0301-620X.92B2.22653","volume":"92","author":"C Berton","year":"2010","unstructured":"Berton C, Girard J, Krantz N, Migaud H (2010) The Durom large diameter head acetabular component: early results with a large-diameter metal-on-metal bearing. J Bone Joint Surg Br 92(2):202\u2013208. doi: 10.1302\/0301-620X.92B2.22653","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"2005_CR2","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1302\/0301-620X.85B5.13993","volume":"85","author":"MT Clarke","year":"2003","unstructured":"Clarke MT, Lee PT, Villar RN (2003) Dislocation after total hip replacement in relation to metal-on-metal bearing surfaces. J Bone Joint Surg Br 85(5):650\u2013654","journal-title":"J Bone Joint Surg Br"},{"key":"2005_CR3","first-page":"165","volume":"50","author":"HA McKellop","year":"2001","unstructured":"McKellop HA (2001) Bearing surfaces in total hip replacements: state of the art and future developments. Instr Course Lect 50:165\u2013179","journal-title":"Instr Course Lect"},{"issue":"4","key":"2005_CR4","first-page":"436","volume":"28","author":"MA Wimmer","year":"2010","unstructured":"Wimmer MA, Fischer A, Buscher R, Pourzal R, Sprecher C, Hauert R, Jacobs JJ (2010) Wear mechanisms in metal-on-metal bearings: the importance of tribochemical reaction layers. J Orthop Res 28(4):436\u2013443. doi: 10.1002\/jor.21020","journal-title":"J Orthop Res"},{"issue":"8","key":"2005_CR5","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1302\/0301-620X.92B8.24194","volume":"92","author":"G Grammatopoulos","year":"2010","unstructured":"Grammatopoulos G, Pandit H, Glyn-Jones S, McLardy-Smith P, Gundle R, Whitwell D, Gill HS, Murray DW (2010) Optimal acetabular orientation for hip resurfacing. J Bone Joint Surg Br 92(8):1072\u20131078. doi: 10.1302\/0301-620X.92B8.2419492-B\/8\/1072","journal-title":"J Bone Joint Surg Br"},{"issue":"9","key":"2005_CR6","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1302\/0301-620X.94B9.29462","volume":"94","author":"DW Murray","year":"2012","unstructured":"Murray DW, Grammatopoulos G, Pandit H, Gundle R, Gill HS, McLardy-Smith P (2012) The ten-year survival of the Birmingham hip resurfacing: an independent series. J Bone Joint Surg Br 94(9):1180\u20131186. doi: 10.1302\/0301-620X.94B9.29462","journal-title":"J Bone Joint Surg Br"},{"issue":"2","key":"2005_CR7","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1007\/s00264-010-1148-8","volume":"35","author":"DJ McMinn","year":"2011","unstructured":"McMinn DJ, Daniel J, Ziaee H, Pradhan C (2011) Indications and results of hip resurfacing. Int Orthop 35(2):231\u2013237. doi: 10.1007\/s00264-010-1148-8","journal-title":"Int Orthop"},{"issue":"1","key":"2005_CR8","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1302\/0301-620X.93B1.24134","volume":"93","author":"RB Treacy","year":"2011","unstructured":"Treacy RB, McBryde CW, Shears E, Pynsent PB (2011) Birmingham hip resurfacing: a minimum follow-up of ten years. J Bone Joint Surg Br 93(1):27\u201333. doi: 10.1302\/0301-620X.93B1.24134","journal-title":"J Bone Joint Surg Br"},{"issue":"8","key":"2005_CR9","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1302\/0301-620X.93B8.26040","volume":"93","author":"DJ Langton","year":"2011","unstructured":"Langton DJ, Jameson SS, Joyce TJ, Gandhi JN, Sidaginamale R, Mereddy P, Lord J, Nargol AV (2011) Accelerating failure rate of the ASR total hip replacement. J Bone Joint Surg Br 93(8):1011\u20131016. doi: 10.1302\/0301-620X.93B8.26040","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"2005_CR10","doi-asserted-by":"crossref","first-page":"28","DOI":"10.2106\/JBJS.A.02039pp","volume":"87","author":"HG Willert","year":"2005","unstructured":"Willert HG, Buchhorn GH, Fayyazi A, Flury R, Windler M, Koster G, Lohmann CH (2005) Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am 87(1):28\u201336. doi: 10.2106\/JBJS.A.02039pp","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"2005_CR11","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1302\/0301-620X.92B1.22770","volume":"92","author":"DJ Langton","year":"2010","unstructured":"Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV (2010) Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg Br 92(1):38\u201346. doi: 10.1302\/0301-620X.92B1.22770","journal-title":"J Bone Joint Surg Br"},{"issue":"3","key":"2005_CR12","doi-asserted-by":"crossref","first-page":"237","DOI":"10.3109\/17453674.2013.797313","volume":"84","author":"AD Liddle","year":"2013","unstructured":"Liddle AD, Satchithananda K, Henckel J, Sabah SA, Vipulendran KV, Lewis A, Skinner JA, Mitchell AW, Hart AJ (2013) Revision of metal-on-metal hip arthroplasty in a tertiary center: a prospective study of 39 hips with between 1 and 4\u00a0years of follow-up. Acta Orthop 84(3):237\u2013245. doi: 10.3109\/17453674.2013.797313","journal-title":"Acta Orthop"},{"issue":"8","key":"2005_CR13","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/j.arth.2013.02.019","volume":"28","author":"F Randelli","year":"2013","unstructured":"Randelli F, Banci L, Favilla S, Maglione D, Aliprandi A (2013) Radiographically undetectable periprosthetic osteolysis with ASR implants: the implication of blood metal ions. J Arthroplasty 28(8):1259\u20131264. doi: 10.1016\/j.arth.2013.02.019","journal-title":"J Arthroplasty"},{"issue":"11","key":"2005_CR14","doi-asserted-by":"crossref","first-page":"3101","DOI":"10.1007\/s11999-012-2502-5","volume":"470","author":"H Meyer","year":"2012","unstructured":"Meyer H, Mueller T, Goldau G, Chamaon K, Ruetschi M, Lohmann CH (2012) Corrosion at the cone\/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties. Clin Orthop Relat Res 470(11):3101\u20133108. doi: 10.1007\/s11999-012-2502-5","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"2005_CR15","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1007\/s11999-013-2788-y","volume":"472","author":"DH Nawabi","year":"2013","unstructured":"Nawabi DH, Gold S, Lyman S, Fields K, Padgett DE, Potter HG (2013) MRI predicts ALVAL and tissue damage in metal-on-metal hip arthroplasty. Clin Orthop Relat Res 472(2):471\u2013481. doi: 10.1007\/s11999-013-2788-y","journal-title":"Clin Orthop Relat Res"},{"issue":"10","key":"2005_CR16","doi-asserted-by":"crossref","first-page":"895","DOI":"10.2106\/JBJS.K.01476","volume":"95","author":"DH Nawabi","year":"2013","unstructured":"Nawabi DH, Hayter CL, Su EP, Koff MF, Perino G, Gold SL, Koch KM, Potter HG (2013) Magnetic resonance imaging findings in symptomatic versus asymptomatic subjects following metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Am 95(10):895\u2013902. doi: 10.2106\/JBJS.K.01476","journal-title":"J Bone Joint Surg Am"},{"key":"2005_CR17","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/BLO.0b013e3181566320","volume":"463","author":"E Garcia-Cimbrelo","year":"2007","unstructured":"Garcia-Cimbrelo E, Tapia M, Martin-Hervas C (2007) Multislice computed tomography for evaluating acetabular defects in revision THA. Clin Orthop Relat Res 463:138\u2013143","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"2005_CR18","doi-asserted-by":"crossref","first-page":"609","DOI":"10.2106\/00004623-200204000-00016","volume":"84-A","author":"L Puri","year":"2002","unstructured":"Puri L, Wixson RL, Stern SH, Kohli J, Hendrix RW, Stulberg SD (2002) Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty. J Bone Joint Surg Am 84-A(4):609\u2013614","journal-title":"J Bone Joint Surg Am"},{"key":"2005_CR19","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/01.blo.0000164028.14504.46","volume":"437","author":"TA Walde","year":"2005","unstructured":"Walde TA, Weiland DE, Leung SB, Kitamura N, Sychterz CJ, Engh CA Jr, Claus AM, Potter HG, Engh CA Sr (2005) Comparison of CT, MRI, and radiographs in assessing pelvic osteolysis: a cadaveric study. Clin Orthop Relat Res 437:138\u2013144","journal-title":"Clin Orthop Relat Res"},{"issue":"16","key":"2005_CR20","doi-asserted-by":"crossref","first-page":"2663","DOI":"10.2106\/JBJS.I.01715","volume":"92","author":"HC Amstutz","year":"2010","unstructured":"Amstutz HC, Le Duff MJ, Campbell PA, Gruen TA, Wisk LE (2010) Clinical and radiographic results of metal-on-metal hip resurfacing with a minimum ten-year follow-up. J Bone Joint Surg Am 92(16):2663\u20132671. doi: 10.2106\/JBJS.I.0171592\/16\/2663","journal-title":"J Bone Joint Surg Am"},{"key":"2005_CR21","first-page":"20","volume":"121","author":"JG DeLee","year":"1976","unstructured":"DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20\u201332","journal-title":"Clin Orthop Relat Res"},{"issue":"8","key":"2005_CR22","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.2106\/00004623-200308000-00013","volume":"85-A","author":"AM Claus","year":"2003","unstructured":"Claus AM, Engh CA Jr, Sychterz CJ, Xenos JS, Orishimo KF, Engh CA Sr (2003) Radiographic definition of pelvic osteolysis following total hip arthroplasty. J Bone Joint Surg Am 85-A(8):1519\u20131526","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"2005_CR23","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1302\/0301-620X.93B5.26309","volume":"93","author":"BJ Bolland","year":"2011","unstructured":"Bolland BJ, Culliford DJ, Langton DJ, Millington JP, Arden NK, Latham JM (2011) High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis. J Bone Joint Surg Br 93(5):608\u2013615. doi: 10.1302\/0301-620X.93B5.26309","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"2005_CR24","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1302\/0301-620X.74B4.1624507","volume":"74","author":"JP Collier","year":"1992","unstructured":"Collier JP, Surprenant VA, Jensen RE, Mayor MB, Surprenant HP (1992) Corrosion between the components of modular femoral hip prostheses. J Bone Joint Surg Br 74(4):511\u2013517","journal-title":"J Bone Joint Surg Br"},{"issue":"12","key":"2005_CR25","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1002\/jbm.820271210","volume":"27","author":"JL Gilbert","year":"1993","unstructured":"Gilbert JL, Buckley CA, Jacobs JJ (1993) In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res 27(12):1533\u20131544. doi: 10.1002\/jbm.820271210","journal-title":"J Biomed Mater Res"},{"issue":"2","key":"2005_CR26","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1002\/jbm.b.10526","volume":"64","author":"JR Goldberg","year":"2003","unstructured":"Goldberg JR, Gilbert JL (2003) In vitro corrosion testing of modular hip tapers. J Biomed Mater Res B Appl Biomater 64(2):78\u201393. doi: 10.1002\/jbm.b.10526","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"2005_CR27","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/1471-2474-11-3","volume":"11","author":"TM Grupp","year":"2010","unstructured":"Grupp TM, Weik T, Bloemer W, Knaebel HP (2010) Modular titanium alloy neck adapter failures in hip replacement\u2014failure mode analysis and influence of implant material. BMC Musculoskelet Disord 11:3. doi: 10.1186\/1471-2474-11-3","journal-title":"BMC Musculoskelet Disord"},{"issue":"7","key":"2005_CR28","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1016\/j.arth.2008.09.009","volume":"24","author":"AM Kop","year":"2009","unstructured":"Kop AM, Swarts E (2009) Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. J Arthroplast 24(7):1019\u20131023. doi: 10.1016\/j.arth.2008.09.009","journal-title":"J Arthroplasty"},{"issue":"2","key":"2005_CR29","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0736-0266(03)00186-4","volume":"22","author":"NJ Hallab","year":"2004","unstructured":"Hallab NJ, Messina C, Skipor A, Jacobs JJ (2004) Differences in the fretting corrosion of metal\u2013metal and ceramic\u2013metal modular junctions of total hip replacements. J Orthop Res 22(2):250\u2013259. doi: 10.1016\/S0736-0266(03)00186-4","journal-title":"J Orthop Res"},{"key":"2005_CR30","author":"GB Higgs","year":"2013","unstructured":"Higgs GB, Hanzlik JA, Macdonald DW, Gilbert JL, Rimnac CM, Kurtz SM, The Implant Research Center Writing C (2013) Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study. J Arthroplast. doi: 10.1016\/j.arth.2013.05.040","journal-title":"J Arthroplast"},{"issue":"4","key":"2005_CR31","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1302\/0301-620X.94B4.27895","volume":"94","author":"JP Holland","year":"2012","unstructured":"Holland JP, Langton DJ, Hashmi M (2012) Ten-year clinical, radiological and metal ion analysis of the Birmingham hip resurfacing: from a single, non-designer surgeon. J Bone Joint Surg Br 94(4):471\u2013476. doi: 10.1302\/0301-620X.94B4.27895","journal-title":"J Bone Joint Surg Br"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-014-2005-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-014-2005-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-014-2005-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,3]],"date-time":"2022-04-03T19:12:02Z","timestamp":1649013122000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-014-2005-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5,18]]},"references-count":31,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2014,7]]}},"alternative-id":["2005"],"URL":"https:\/\/doi.org\/10.1007\/s00402-014-2005-9","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5,18]]}}}