{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T18:06:13Z","timestamp":1793210773394,"version":"4.5.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2015,7,21]],"date-time":"2015-07-21T00:00:00Z","timestamp":1437436800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2015,10]]},"DOI":"10.1007\/s00402-015-2284-9","type":"journal-article","created":{"date-parts":[[2015,7,20]],"date-time":"2015-07-20T15:28:29Z","timestamp":1437406109000},"page":"1349-1356","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Radiologic healing of lateral femoral wall fragments after intramedullary nail fixation for A3.3 intertrochanteric fractures"],"prefix":"10.1007","volume":"135","author":[{"given":"Youngwoo","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Won Jong","family":"Bahk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong-Cheol","family":"Yoon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jae-Woo","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Won-Yong","family":"Shon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chang-Wug","family":"Oh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong-Keon","family":"Oh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,7,21]]},"reference":[{"key":"2284_CR1","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1302\/0301-620X.75B3.8496218","volume":"75","author":"AL Desjardins","year":"1993","unstructured":"Desjardins AL, Roy A, Paiement G, Newman N, Pedlow F, Desloges D, Turcotte RE (1993) Unstable intertrochanteric fracture of the femur. A prospective randomised study comparing anatomical reduction and medial displacement osteotomy. J Bone Joint Surg Br 75:445\u2013447","journal-title":"J Bone Joint Surg Br"},{"key":"2284_CR2","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1097\/00005131-200108000-00003","volume":"15","author":"CI Adams","year":"2001","unstructured":"Adams CI, Robinson CM, Court-Brown CM, McQueen MM (2001) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. J Orthop Trauma 15:394\u2013400","journal-title":"J Orthop Trauma"},{"key":"2284_CR3","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/00005131-200205000-00016","volume":"16","author":"I Bartonicek","year":"2002","unstructured":"Bartonicek I, Dousa P (2002) Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate of intertrochanteric fractures of the femur. J Orthop Trauma 16:363\u2013364 (author reply 364)","journal-title":"J Orthop Trauma"},{"key":"2284_CR4","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1097\/01.blo.0000132264.14046.c2","volume":"425","author":"Y Gotfried","year":"2004","unstructured":"Gotfried Y (2004) The lateral trochanteric wall: a key element in the reconstruction of unstable pertrochanteric hip fractures. Clin Orthop Relat Res 425:82\u201386","journal-title":"Clin Orthop Relat Res"},{"key":"2284_CR5","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/00005131-200711101-00001","volume":"21","author":"JL Marsh","year":"2007","unstructured":"Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA, Prokuski L, Sirkin M, Ziran B, Henley B, Audig\u00e9 L (2007) Fracture and dislocation classification compendium\u20142007: orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21:S1\u2013133","journal-title":"J Orthop Trauma"},{"key":"2284_CR6","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1097\/00003086-199904000-00027","volume":"361","author":"F Baixauli","year":"1999","unstructured":"Baixauli F, Vicent V, Baixauli E, Serra V, S\u00e1nchez-Alepuz E, G\u00f3mez V, Martos F (1999) A reinforced rigid fixation device for unstable intertrochanteric fractures. Clin Orthop Relat Res 361:205\u2013215","journal-title":"Clin Orthop Relat Res"},{"key":"2284_CR7","first-page":"341","volume":"91","author":"J M\u00fcller-F\u00e4rber","year":"1988","unstructured":"M\u00fcller-F\u00e4rber J, Wittner B, Reichel R (1988) Late results in the management of pertrochanteric femoral fractures in the elderly with the dynamic hip screw. Unfallchirurg 91:341\u2013350","journal-title":"Unfallchirurg"},{"key":"2284_CR8","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1097\/00005131-199808000-00005","volume":"12","author":"R Babst","year":"1998","unstructured":"Babst R, Renner N, Biedermann M, Rosso R, Heberer M, Harder F, Regazzoni P (1998) Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma 12:392\u2013399","journal-title":"J Orthop Trauma"},{"key":"2284_CR9","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s00264-009-0744-y","volume":"34","author":"RK Gupta","year":"2010","unstructured":"Gupta RK, Sangwan K, Kamboj P, Punia SS, Walecha P (2010) Unstable trochanteric fractures: the role of lateral wall reconstruction. Int Orthop 34:125\u2013129. doi: 10.1007\/s00264-009-0744-y","journal-title":"Int Orthop"},{"key":"2284_CR10","doi-asserted-by":"crossref","first-page":"643","DOI":"10.2106\/00004623-200105000-00001","volume":"83-A","author":"GJ Haidukewych","year":"2001","unstructured":"Haidukewych GJ, Israel TA, Berry DJ (2001) Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg Am 83-A:643\u2013650","journal-title":"J Bone Joint Surg Am"},{"key":"2284_CR11","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/BOT.0b013e31819211b2","volume":"23","author":"AH Ruecker","year":"2009","unstructured":"Ruecker AH, Rupprecht M, Gruber M, Gebauer M, Barvencik F, Briem D, Rueger JM (2009) The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression. J Orthop Trauma 23:22\u201330. doi: 10.1097\/BOT.0b013e31819211b2","journal-title":"J Orthop Trauma"},{"key":"2284_CR12","doi-asserted-by":"crossref","first-page":"372","DOI":"10.2106\/00004623-200203000-00007","volume":"84-A","author":"C Sadowski","year":"2002","unstructured":"Sadowski C, L\u00fcbbeke A, Saudan M, Riand N, Stern R, Hoffmeyer P (2002) Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg Am 84-A:372\u2013381","journal-title":"J Bone Joint Surg Am"},{"key":"2284_CR13","doi-asserted-by":"crossref","first-page":"618","DOI":"10.2106\/00004623-199805000-00002","volume":"80","author":"DC Hardy","year":"1998","unstructured":"Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE (1998) Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg Am 80:618\u2013630","journal-title":"J Bone Joint Surg Am"},{"key":"2284_CR14","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","volume":"77","author":"MR Baumgaertner","year":"1995","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77:1058\u20131064","journal-title":"J Bone Joint Surg Am"},{"key":"2284_CR15","doi-asserted-by":"crossref","first-page":"117","DOI":"10.3928\/0147-7447-20050201-11","volume":"28","author":"MJ Gardner","year":"2005","unstructured":"Gardner MJ, Bhandari M, Lawrence BD, Helfet DL, Lorich DG (2005) Treatment of intertrochanteric hip fractures with the AO trochanteric fixation nail. Orthopedics 28:117\u2013122","journal-title":"Orthopedics"},{"key":"2284_CR16","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1097\/00003086-199803000-00015","volume":"348","author":"MR Baumgaertner","year":"1998","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res 348:87\u201394","journal-title":"Clin Orthop Relat Res"},{"key":"2284_CR17","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1016\/j.injury.2014.02.007","volume":"45","author":"Y Kim","year":"2014","unstructured":"Kim Y, Dheep K, Lee J, Yoon Y-C, Shon W-Y, Oh C-W, Oh J-K (2014) Hook leverage technique for reduction of intertrochanteric fracture. Injury 45:1006\u20131010. doi: 10.1016\/j.injury.2014.02.007","journal-title":"Injury"},{"key":"2284_CR18","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1097\/BOT.0b013e318251930d","volume":"27","author":"PN Streubel","year":"2013","unstructured":"Streubel PN, Moustoukas MJ, Obremskey WT (2013) Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures. J Orthop Trauma 27:22\u201328. doi: 10.1097\/BOT.0b013e318251930d","journal-title":"J Orthop Trauma"},{"key":"2284_CR19","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.injury.2013.02.020","volume":"44","author":"C Wirtz","year":"2013","unstructured":"Wirtz C, Abbassi F, Evangelopoulos DS, Kohl S, Siebenrock KA, Kr\u00fcger A (2013) High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate. Injury 44:751\u2013756. doi: 10.1016\/j.injury.2013.02.020","journal-title":"Injury"},{"key":"2284_CR20","doi-asserted-by":"crossref","first-page":"470","DOI":"10.2106\/JBJS.F.00679","volume":"89","author":"H Palm","year":"2007","unstructured":"Palm H, Jacobsen S, Sonne-Holm S, Gebuhr P (2007) Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation. J Bone Joint Surg Am 89:470\u2013475. doi: 10.2106\/JBJS.F.00679","journal-title":"J Bone Joint Surg Am"},{"key":"2284_CR21","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1097\/BOT.0b013e318244e5ad","volume":"26","author":"PRJVC Boopalan","year":"2012","unstructured":"Boopalan PRJVC, Oh J-K, Kim T-Y, Oh C-W, Cho J-W, Shon W-Y (2012) Incidence and radiologic outcome of intraoperative lateral wall fractures in OTA 31A1 and A2 fractures treated with cephalomedullary nailing. J Orthop Trauma 26:638\u2013642. doi: 10.1097\/BOT.0b013e318244e5ad","journal-title":"J Orthop Trauma"},{"key":"2284_CR22","doi-asserted-by":"crossref","first-page":"1189","DOI":"10.1016\/j.injury.2007.03.014","volume":"38","author":"MJ Gardner","year":"2007","unstructured":"Gardner MJ, Briggs SM, Kopjar B, Helfet DL, Lorich DG (2007) Radiographic outcomes of intertrochanteric hip fractures treated with the trochanteric fixation nail. Injury 38:1189\u20131196. doi: 10.1016\/j.injury.2007.03.014","journal-title":"Injury"},{"key":"2284_CR23","first-page":"712","volume":"91","author":"GJ Haidukewych","year":"2009","unstructured":"Haidukewych GJ (2009) Intertrochanteric fractures: ten tips to improve results. J Bone Joint Surg Am 91:712\u2013719","journal-title":"J Bone Joint Surg Am"},{"key":"2284_CR24","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1302\/0301-620X.79B6.7949","volume":"79","author":"MR Baumgaertner","year":"1997","unstructured":"Baumgaertner MR, Solberg BD (1997) Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip. J Bone Joint Surg Br 79:969\u2013971","journal-title":"J Bone Joint Surg Br"},{"key":"2284_CR25","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1177\/112070001002000213","volume":"20","author":"F Guerra Pinto","year":"2010","unstructured":"Guerra Pinto F, Dantas P, Moreira R, Mamede R, Amaral LB (2010) Complications relating to accuracy of reduction of intertrochanteric fractures treated with a compressive hip screw. Hip Int 20:221\u2013228","journal-title":"Hip Int"},{"key":"2284_CR26","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.semcdb.2008.07.004","volume":"19","author":"A Schindeler","year":"2008","unstructured":"Schindeler A, McDonald MM, Bokko P, Little DG (2008) Bone remodeling during fracture repair: the cellular picture. Semin Cell Dev Biol 19:459\u2013466. doi: 10.1016\/j.semcdb.2008.07.004","journal-title":"Semin Cell Dev Biol"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-015-2284-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-015-2284-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-015-2284-9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,5]],"date-time":"2020-09-05T07:47:46Z","timestamp":1599292066000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-015-2284-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,7,21]]},"references-count":26,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2015,10]]}},"alternative-id":["2284"],"URL":"https:\/\/doi.org\/10.1007\/s00402-015-2284-9","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,7,21]]}}}