{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,4]],"date-time":"2025-05-04T06:26:15Z","timestamp":1746339975641},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2019,2,12]],"date-time":"2019-02-12T00:00:00Z","timestamp":1549929600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"The 2016th Science and technology breakthrough project of Henan province","award":["162102310018"],"award-info":[{"award-number":["162102310018"]}]},{"name":"Henan provincial science and technology innovation outstanding talent project","award":["154200510027"],"award-info":[{"award-number":["154200510027"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2019,6]]},"DOI":"10.1007\/s00402-018-03106-2","type":"journal-article","created":{"date-parts":[[2019,2,12]],"date-time":"2019-02-12T06:50:12Z","timestamp":1549954212000},"page":"751-760","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Design and preliminary biomechanical analysis of a novel motion preservation device for lumbar spinal disease after vertebral corpectomy"],"prefix":"10.1007","volume":"139","author":[{"given":"Jiantao","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xijing","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhengchao","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Binbin","family":"Niu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dongbo","family":"Lv","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanzheng","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,2,12]]},"reference":[{"issue":"6","key":"3106_CR1","doi-asserted-by":"publisher","first-page":"1066","DOI":"10.1016\/j.wneu.2014.12.039","volume":"83","author":"B Chen","year":"2015","unstructured":"Chen B et al (2015) Comparison of the therapeutic efficacy of surgery with or without adjuvant radiotherapy versus radiotherapy alone for metastatic spinal cord compression: a meta-analysis. World Neurosurg 83(6):1066\u20131073","journal-title":"World Neurosurg"},{"issue":"12","key":"3106_CR2","doi-asserted-by":"publisher","first-page":"2109","DOI":"10.1016\/j.injury.2012.04.008","volume":"43","author":"H Wang","year":"2012","unstructured":"Wang H et al (2012) Epidemiology of spinal fractures among the elderly in Chongqing, China. Inj Int J Care Inj 43(12):2109\u20132116","journal-title":"Inj Int J Care Inj"},{"key":"3106_CR3","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.wneu.2017.08.179","volume":"108","author":"R Bradford","year":"2017","unstructured":"Bradford R et al (2017) Anterior lumbar corpectomy with expandable titanium cage reconstruction\u2014a case series of 42 patients. World Neurosurg 108:317\u2013324","journal-title":"World Neurosurg"},{"issue":"7","key":"3106_CR4","doi-asserted-by":"publisher","first-page":"E265","DOI":"10.1097\/BSD.0b013e3182867489","volume":"26","author":"C-N Kang","year":"2013","unstructured":"Kang C-N et al (2013) Anterior operation for unstable thoracolumbar and lumbar burst fractures tricortical autogenous iliac bone versus titanium mesh cage. J Spinal Disord Tech 26(7):E265\u2013E271","journal-title":"J Spinal Disord Tech"},{"key":"3106_CR5","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1007\/s00586-017-5011-0","volume":"26","author":"A Pingel","year":"2017","unstructured":"Pingel A, Castein J, Kandziora F (2017) Anterior monosegmental stabilization and fusion of an incomplete cranial burst fracture in the thoracolumbar spine via a mini-open, thoracoscopically assisted transthoracic approach. Eur Spine J 26:431\u2013432","journal-title":"Eur Spine J"},{"key":"3106_CR6","doi-asserted-by":"publisher","first-page":"3016","DOI":"10.1007\/s00586-017-5356-4","volume":"27","author":"M Scholz","year":"2017","unstructured":"Scholz M et al. (2017) Prospective randomized controlled comparison of posterior vs. posterior\u2013anterior stabilization of thoracolumbar incomplete cranial burst fractures in neurological intact patients: the RASPUTHINE pilot study. Eur Spine J 27:3016\u20133024","journal-title":"Eur Spine J"},{"key":"3106_CR7","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.clineuro.2014.10.019","volume":"128","author":"P Liu","year":"2015","unstructured":"Liu P et al (2015) A retrospective controlled study of three different operative approaches for the treatment of thoracic and lumbar spinal tuberculosis: three years of follow-up. Clin Neurol Neurosurg 128:25\u201334","journal-title":"Clin Neurol Neurosurg"},{"issue":"1","key":"3106_CR8","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1097\/BSD.0000000000000328","volume":"29","author":"C Zhang","year":"2016","unstructured":"Zhang C et al (2016) Adjacent segment degeneration versus disease after lumbar spine fusion for degenerative pathology a systematic review with meta-analysis of the literature. Clin Spine Surg 29(1):21\u201329","journal-title":"Clin Spine Surg"},{"issue":"5","key":"3106_CR9","doi-asserted-by":"publisher","first-page":"1522","DOI":"10.1007\/s00586-016-4415-6","volume":"25","author":"A Pan","year":"2016","unstructured":"Pan A et al (2016) Adjacent segment degeneration after lumbar spinal fusion compared with motion-preservation procedures: a meta-analysis. Eur Spine J 25(5):1522\u20131532","journal-title":"Eur Spine J"},{"issue":"4","key":"3106_CR10","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1007\/s00586-014-3462-0","volume":"24","author":"H-J Kim","year":"2015","unstructured":"Kim H-J et al (2015) The influence of intrinsic disc degeneration of the adjacent segments on its stress distribution after one-level lumbar fusion. Eur Spine J 24(4):827\u2013837","journal-title":"Eur Spine J"},{"issue":"9","key":"3106_CR11","doi-asserted-by":"publisher","first-page":"2056","DOI":"10.1007\/s00586-015-3939-5","volume":"24","author":"S-b Lu","year":"2015","unstructured":"Lu S-b et al (2015) An 11-year minimum follow-up of the Charite III lumbar disc replacement for the treatment of symptomatic degenerative disc disease. Eur Spine J 24(9):2056\u20132064","journal-title":"Eur Spine J"},{"key":"3106_CR12","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.spinee.2017.06.035","volume":"18","author":"C Wuertinger","year":"2017","unstructured":"Wuertinger C et al (2017) Motion preservation following total lumbar disc replacement at the lumbosacral junction: a prospective long-term clinical and radiographic investigation. Spine J 18:72\u201380","journal-title":"Spine J"},{"issue":"5","key":"3106_CR13","first-page":"350","volume":"46","author":"Y-Z Ma","year":"2008","unstructured":"Ma Y-Z et al (2008) The mid- or long-term clinical results of prosthetic disc nucleus replacement in the treatment of lumbar disc disease. Zhonghua wai ke za zhi [Chinese journal of surgery] 46(5):350\u2013353","journal-title":"Zhonghua wai ke za zhi [Chinese journal of surgery]"},{"issue":"6","key":"3106_CR14","first-page":"e637","volume":"8","author":"A Kashkoush","year":"2016","unstructured":"Kashkoush A et al (2016) Evaluation of a hybrid dynamic stabilization and fusion system in the lumbar spine: a 10 year experience. Cureus 8(6):e637\u2013e637","journal-title":"Cureus"},{"issue":"11","key":"3106_CR15","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.1007\/s00402-017-2753-4","volume":"137","author":"J Liu","year":"2017","unstructured":"Liu J et al (2017) Lumbar subtotal corpectomy non-fusion model produced using a novel prosthesis. Arch Orthop Trauma Surg 137(11):1467\u20131476","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"3106_CR16","first-page":"5","volume":"14","author":"J Liu","year":"2017","unstructured":"Liu J, Li H, Niu B (2017) Design and activity analysis of bionic artificial lumbar vertebra and disc complex. Orthop Biomech Mater Clin Stud 14(2):5\u201310","journal-title":"Orthop Biomech Mater Clin Stud"},{"key":"3106_CR17","doi-asserted-by":"publisher","first-page":"3105","DOI":"10.12659\/MSM.901993","volume":"23","author":"T Lu","year":"2017","unstructured":"Lu T et al (2017) Single-level anterior cervical corpectomy and fusion using a new 3D-printed anatomy-adaptive titanium mesh cage for treatment of cervical spondylotic myelopathy and ossification of the posterior longitudinal ligament: a retrospective case series study. Med Sci Monit 23:3105\u20133114","journal-title":"Med Sci Monit"},{"issue":"2","key":"3106_CR18","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1007\/s005860050045","volume":"7","author":"HJ Wilke","year":"1998","unstructured":"Wilke HJ, Wenger K, Claes L (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 7(2):148\u2013154","journal-title":"Eur Spine J"},{"issue":"9","key":"3106_CR19","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/j.clinbiomech.2007.07.010","volume":"22","author":"AC Disch","year":"2007","unstructured":"Disch AC et al (2007) Three-dimensional stiffness in a thoracolumbar en-bloc spondylectomy model: a biomechanical in vitro study. Clin Biomech 22(9):957\u2013964","journal-title":"Clin Biomech"},{"issue":"5","key":"3106_CR20","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1007\/s00586-008-0588-y","volume":"17","author":"AC Disch","year":"2008","unstructured":"Disch AC et al (2008) En bloc spondylectomy reconstructions in a biomechanical in-vitro study. Eur Spine J 17(5):715\u2013725","journal-title":"Eur Spine J"},{"issue":"20","key":"3106_CR21","doi-asserted-by":"publisher","first-page":"2365","DOI":"10.1097\/00007632-199710150-00009","volume":"22","author":"HJ Wilke","year":"1997","unstructured":"Wilke HJ, Kettler A, Claes LE (1997) Are sheep spines a valid biomechanical model for human spines? Spine 22(20):2365\u20132374","journal-title":"Spine"},{"issue":"6","key":"3106_CR22","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1016\/j.arcmed.2010.08.013","volume":"41","author":"JJ Ramirez","year":"2010","unstructured":"Ramirez JJ et al (2010) An expandable prosthesis with dual cage-and-plate function in a single device for vertebral body replacement: clinical experience on 14 cases with vertebral tumors. Arch Med Res 41(6):478\u2013482","journal-title":"Arch Med Res"},{"issue":"7","key":"3106_CR23","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1007\/s00104-003-0786-4","volume":"75","author":"C Khodadadyan-Klostermann","year":"2004","unstructured":"Khodadadyan-Klostermann C et al (2004) Expandable cages: biomechanical comparison of different cages for ventral spondylodesis in the thoracolumbar spine. Chirurg 75(7):694\u2013701","journal-title":"Chirurg"},{"issue":"9","key":"3106_CR24","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1007\/s00402-011-1284-7","volume":"131","author":"R Penzkofer","year":"2011","unstructured":"Penzkofer R et al (2011) Biomechanical comparison of the end plate design of three vertebral body replacement systems. Arch Orthop Trauma Surg 131(9):1253\u20131259","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"3106_CR25","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1007\/s10195-007-0166-9","volume":"8","author":"U Vieweg","year":"2007","unstructured":"Vieweg U (2007) Vertebral body replacement system Synex in unstable burst fractures of the thoracic and lumbar spine. J Orthop Traumatol 8(2):64\u201370","journal-title":"J Orthop Traumatol"},{"issue":"12","key":"3106_CR26","doi-asserted-by":"publisher","first-page":"e52910","DOI":"10.1371\/journal.pone.0052910","volume":"7","author":"J Qin","year":"2012","unstructured":"Qin J et al (2012) Artificial cervical vertebra and intervertebral complex replacement through the anterior approach in animal model: a biomechanical and in vivo evaluation of a successful goat model. PLoS One 7(12):e52910","journal-title":"PLoS One"},{"issue":"7","key":"3106_CR27","doi-asserted-by":"publisher","first-page":"493","DOI":"10.6061\/clinics\/2015(07)06","volume":"70","author":"J Dong","year":"2015","unstructured":"Dong J et al (2015) Artificial disc and vertebra system: a novel motion preservation device for cervical spinal disease after vertebral corpectomy. Clinics 70(7):493\u2013499","journal-title":"Clinics"},{"issue":"9","key":"3106_CR28","doi-asserted-by":"publisher","first-page":"1329","DOI":"10.1007\/s00402-013-1826-2","volume":"133","author":"J Yu","year":"2013","unstructured":"Yu J, Liu L-T, Zhao J-N (2013) Design and preliminary biomechanical analysis of artificial cervical joint complex (vol 133, pg 735, 2013). Arch Orthop Trauma Surg 133(9):1329\u20131329","journal-title":"Arch Orthop Trauma Surg"},{"issue":"10","key":"3106_CR29","doi-asserted-by":"publisher","first-page":"1779","DOI":"10.1016\/j.jocn.2014.02.016","volume":"21","author":"J-W Jang","year":"2014","unstructured":"Jang J-W et al (2014) Effect of posterior subsidence on cervical alignment after anterior cervical corpectomy and reconstruction using titanium mesh cages in degenerative cervical disease. J Clin Neurosci 21(10):1779\u20131785","journal-title":"J Clin Neurosci"},{"key":"3106_CR30","doi-asserted-by":"publisher","first-page":"2863","DOI":"10.12659\/MSM.905466","volume":"23","author":"T Lu","year":"2017","unstructured":"Lu T et al (2017) Effects of titanium mesh cage end structures on the compressive load at the endplate interface: a cadaveric biomechanical study. Med Sci Monit 23:2863\u20132870","journal-title":"Med Sci Monit"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-018-03106-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-018-03106-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-018-03106-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,12]],"date-time":"2020-02-12T00:12:31Z","timestamp":1581466351000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-018-03106-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,12]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019,6]]}},"alternative-id":["3106"],"URL":"https:\/\/doi.org\/10.1007\/s00402-018-03106-2","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,12]]},"assertion":[{"value":"12 September 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 February 2019","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}