{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T20:10:19Z","timestamp":1770754219161,"version":"3.50.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2020,4,6]],"date-time":"2020-04-06T00:00:00Z","timestamp":1586131200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,4,6]],"date-time":"2020-04-06T00:00:00Z","timestamp":1586131200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2020,12]]},"DOI":"10.1007\/s00402-020-03438-y","type":"journal-article","created":{"date-parts":[[2020,4,6]],"date-time":"2020-04-06T08:04:41Z","timestamp":1586160281000},"page":"1931-1937","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Comparing iatrogenic radial nerve lesions in humeral shaft fractures treated with helical or straight PHILOS plates: a 10-year retrospective cohort study of 62 cases"],"prefix":"10.1007","volume":"140","author":[{"given":"Tomas","family":"Da Silva","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franziska","family":"Rummel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Knop","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Merkle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,6]]},"reference":[{"issue":"Suppl 1","key":"3438_CR1","doi-asserted-by":"publisher","first-page":"S54","DOI":"10.1016\/j.injury.2013.10.030","volume":"45","author":"HW Stedtfeld","year":"2014","unstructured":"Stedtfeld HW, Biber R (2014) Proximal third humeral shaft fractures\u2014a fracture entity not fully characterized by conventional AO classification. Injury 45(Suppl 1):S54\u201359. https:\/\/doi.org\/10.1016\/j.injury.2013.10.030","journal-title":"Injury"},{"key":"3438_CR2","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1302\/0301-620X.88B11.17634","volume":"88","author":"R Ekholm","year":"2006","unstructured":"Ekholm R, Adami J, Tidermark J et al (2006) Fractures of the shaft of the humerus. An epidemiological study of 401 fractures. J Bone Jt Surg Br 88:1469\u20131473. https:\/\/doi.org\/10.1302\/0301-620X.88B11.17634","journal-title":"J Bone Jt Surg Br"},{"key":"3438_CR3","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1007\/s00113-018-0533-4","volume":"121","author":"R Biber","year":"2018","unstructured":"Biber R, Bail HJ, Ge\u00dflein M (2018) Humeral shaft fractures. Unfallchirurg 121:747\u2013758. https:\/\/doi.org\/10.1007\/s00113-018-0533-4","journal-title":"Unfallchirurg"},{"key":"3438_CR4","doi-asserted-by":"publisher","first-page":"1647","DOI":"10.1302\/0301-620X.87B12.16132","volume":"87","author":"YC Shao","year":"2005","unstructured":"Shao YC, Harwood P, Grotz MRW et al (2005) Radial nerve palsy associated with fractures of the shaft of the humerus: a systematic review. J Bone Jt Surg Br 87:1647\u20131652. https:\/\/doi.org\/10.1302\/0301-620X.87B12.16132","journal-title":"J Bone Jt Surg Br"},{"key":"3438_CR5","volume-title":"Prometheus LernAtlas der Anatomie. Allgemeine Anatomie und Bewegungssystem","author":"M Sch\u00fcnke","year":"2007","unstructured":"Sch\u00fcnke M, Schulte E, Schumacher U (2007) Prometheus LernAtlas der Anatomie. Allgemeine Anatomie und Bewegungssystem. Thieme, Stuttgart"},{"key":"3438_CR6","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s00068-017-0775-9","volume":"44","author":"TR Schwab","year":"2018","unstructured":"Schwab TR, Stillhard PF, Schibli S et al (2018) Radial nerve palsy in humeral shaft fractures with internal fixation: analysis of management and outcome. Eur J Trauma Emerg Surg Off Publ Eur Trauma Soc 44:235\u2013243. https:\/\/doi.org\/10.1007\/s00068-017-0775-9","journal-title":"Eur J Trauma Emerg Surg Off Publ Eur Trauma Soc"},{"key":"3438_CR7","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-019-03319-z","author":"BJM van de Wall","year":"2019","unstructured":"van de Wall BJM, Ganzert C, Theus C et al (2019) Results of plate fixation for humerus fractures in a large single-center cohort. Arch Orthop Trauma Surg. https:\/\/doi.org\/10.1007\/s00402-019-03319-z","journal-title":"Arch Orthop Trauma Surg"},{"key":"3438_CR8","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1097\/BOT.0000000000000232","volume":"29","author":"JW Kim","year":"2015","unstructured":"Kim JW, Oh C-W, Byun Y-S et al (2015) A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis. J Orthop Trauma 29:189\u2013194. https:\/\/doi.org\/10.1097\/BOT.0000000000000232","journal-title":"J Orthop Trauma"},{"key":"3438_CR9","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1097\/00005373-196705000-00007","volume":"7","author":"DB Kettelkamp","year":"1967","unstructured":"Kettelkamp DB, Alexander H (1967) Clinical review of radial nerve injury. J Trauma 7:424\u2013432","journal-title":"J Trauma"},{"key":"3438_CR10","doi-asserted-by":"publisher","first-page":"e307","DOI":"10.1016\/j.jse.2015.07.012","volume":"24","author":"FMAP Claessen","year":"2015","unstructured":"Claessen FMAP, Peters RM, Verbeek DO et al (2015) Factors associated with radial nerve palsy after operative treatment of diaphyseal humeral shaft fractures. J Shoulder Elb Surg 24:e307\u2013311. https:\/\/doi.org\/10.1016\/j.jse.2015.07.012","journal-title":"J Shoulder Elb Surg"},{"key":"3438_CR11","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s00113-016-0264-3","volume":"120","author":"B Jacoby","year":"2017","unstructured":"Jacoby B, Wasylewski K, Zinser W (2017) Regeneration of a radial nerve after compression under an osteosynthesis plate. Unfallchirurg 120:257\u2013261. https:\/\/doi.org\/10.1007\/s00113-016-0264-3","journal-title":"Unfallchirurg"},{"key":"3438_CR12","doi-asserted-by":"publisher","first-page":"184","DOI":"10.2174\/1874325001206010184","volume":"6","author":"JCH Tan","year":"2012","unstructured":"Tan JCH, Kagda FHY, Murphy D et al (2012) Minimally invasive helical plating for shaft of humerus fractures: technique and outcome. Open Orthop J 6:184\u2013188. https:\/\/doi.org\/10.2174\/1874325001206010184","journal-title":"Open Orthop J"},{"key":"3438_CR13","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1097\/00005131-199902000-00013","volume":"13","author":"DR Gill","year":"1999","unstructured":"Gill DR, Torchia ME (1999) The spiral compression plate for proximal humeral shaft nonunion: a case report and description of a new technique. J Orthop Trauma 13:141\u2013144","journal-title":"J Orthop Trauma"},{"key":"3438_CR14","doi-asserted-by":"publisher","first-page":"e237","DOI":"10.3928\/01477447-20140225-55","volume":"37","author":"J-G Moon","year":"2014","unstructured":"Moon J-G, Kwon H-N, Biraris S, Shon W-Y (2014) Minimally invasive plate osteosynthesis using a helical plate for metadiaphyseal complex fractures of the proximal humerus. Orthopedics 37:e237\u2013243. https:\/\/doi.org\/10.3928\/01477447-20140225-55","journal-title":"Orthopedics"},{"key":"3438_CR15","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.injury.2004.03.023","volume":"36","author":"KH Yang","year":"2005","unstructured":"Yang KH (2005) Helical plate fixation for treatment of comminuted fractures of the proximal and middle one-third of the humerus. Injury 36:75\u201380. https:\/\/doi.org\/10.1016\/j.injury.2004.03.023","journal-title":"Injury"},{"key":"3438_CR16","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1016\/j.injury.2005.06.038","volume":"36","author":"MJ Gardner","year":"2005","unstructured":"Gardner MJ, Griffith MH, Lorich DG (2005) Helical plating of the proximal humerus. Injury 36:1197\u20131200. https:\/\/doi.org\/10.1016\/j.injury.2005.06.038","journal-title":"Injury"},{"key":"3438_CR17","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1186\/s13018-018-0908-9","volume":"13","author":"Q Wang","year":"2018","unstructured":"Wang Q, Hu J, Guan J et al (2018) Proximal third humeral shaft fractures fixed with long helical PHILOS plates in elderly patients: benefit of pre-contouring plates on a 3D-printed model-a retrospective study. J Orthop Surg 13:203. https:\/\/doi.org\/10.1186\/s13018-018-0908-9","journal-title":"J Orthop Surg"},{"issue":"Suppl 1","key":"3438_CR18","doi-asserted-by":"publisher","first-page":"SA1","DOI":"10.1016\/S0020-1383(02)00064-5","volume":"33","author":"AA Fern\u00e1ndez Dell\u2019Oca","year":"2002","unstructured":"Fern\u00e1ndez Dell\u2019Oca AA (2002) The principle of helical implants. Unusual ideas worth considering. Injury 33(Suppl 1):SA1\u2013SA27","journal-title":"Injury"},{"key":"3438_CR19","unstructured":"DePuy Synthes (2016) PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus. https:\/\/synthes.vo.llnwd.net\/o16\/LLNWMB8\/INT%20Mobile\/Synthes%20International\/Product%20Support%20Material\/legacy_Synthes_PDF\/DSEM-TRM-0815-0449_LR.pdf. Accessed April 2020"},{"key":"3438_CR20","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1097\/00003086-200004000-00032","volume":"373","author":"CM Bono","year":"2000","unstructured":"Bono CM, Grossman MG, Hochwald N, Tornetta P (2000) Radial and axillary nerves. Anatomic considerations for humeral fixation. Clin Orthop 373:259\u2013264","journal-title":"Clin Orthop"},{"key":"3438_CR21","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1007\/s00590-013-1324-9","volume":"24","author":"B Arumilli","year":"2014","unstructured":"Arumilli B, Suhm N, Marcel J, Rikli D (2014) Long PHILOS plate fixation in a series of humeral fractures. Eur J Orthop Surg Traumatol Orthop Traumatol 24:1383\u20131387. https:\/\/doi.org\/10.1007\/s00590-013-1324-9","journal-title":"Eur J Orthop Surg Traumatol Orthop Traumatol"},{"key":"3438_CR22","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1186\/s13018-016-0394-x","volume":"11","author":"X Hu","year":"2016","unstructured":"Hu X, Xu S, Lu H et al (2016) Minimally invasive plate osteosynthesis vs conventional fixation techniques for surgically treated humeral shaft fractures: a meta-analysis. J Orthop Surg 11:59. https:\/\/doi.org\/10.1186\/s13018-016-0394-x","journal-title":"J Orthop Surg"},{"key":"3438_CR23","doi-asserted-by":"publisher","first-page":"241968","DOI":"10.1155\/2015\/241968","volume":"2015","author":"U Bichsel","year":"2015","unstructured":"Bichsel U, Nyffeler RW (2015) Secondary radial nerve palsy after minimally invasive plate osteosynthesis of a distal humeral shaft fracture. Case Rep Orthop 2015:241968. https:\/\/doi.org\/10.1155\/2015\/241968","journal-title":"Case Rep Orthop"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-020-03438-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00402-020-03438-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-020-03438-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,5]],"date-time":"2021-04-05T23:27:05Z","timestamp":1617665225000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00402-020-03438-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,6]]},"references-count":23,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["3438"],"URL":"https:\/\/doi.org\/10.1007\/s00402-020-03438-y","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,6]]},"assertion":[{"value":"24 November 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 April 2020","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Nothing to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Support\/grants"}}]}}