{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T05:46:36Z","timestamp":1785563196363,"version":"3.56.0"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2020,8,3]],"date-time":"2020-08-03T00:00:00Z","timestamp":1596412800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,8,3]],"date-time":"2020-08-03T00:00:00Z","timestamp":1596412800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1007\/s00402-020-03550-z","type":"journal-article","created":{"date-parts":[[2020,8,3]],"date-time":"2020-08-03T17:05:52Z","timestamp":1596474352000},"page":"1819-1824","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Correlation of tibial component size and rotation with outcomes after total knee arthroplasty"],"prefix":"10.1007","volume":"140","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0819-4706","authenticated-orcid":false,"given":"Antonio","family":"Klasan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua G.","family":"Twiggs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brett A.","family":"Fritsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brad P.","family":"Miles","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas J.","family":"Heyse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Solomon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David A.","family":"Parker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,8,3]]},"reference":[{"key":"3550_CR1","unstructured":"National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (2019) The National Joint Registry Annual Report 2019. https:\/\/www.hqip.org.uk\/wp-content\/uploads\/2018\/11\/NJR-15th-Annual-Report-2018.pdf"},{"key":"3550_CR2","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1302\/0301-620X.95B11.32767","volume":"95-B","author":"MJ Dunbar","year":"2013","unstructured":"Dunbar MJ, Richardson G, Robertsson O (2013) I can\u2019t get no satisfaction after my total knee replacement: rhymes and reasons. Bone Jt J 95-B:148\u2013152. https:\/\/doi.org\/10.1302\/0301-620X.95B11.32767","journal-title":"Bone Jt J"},{"key":"3550_CR3","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1302\/0301-620X.92B9.23516","volume":"92","author":"D Nicoll","year":"2010","unstructured":"Nicoll D, Rowley DI (2010) Internal rotational error of the tibial component is a major cause of pain after total knee replacement. J Bone Jt Surg Br 92:1238\u20131244. https:\/\/doi.org\/10.1302\/0301-620X.92B9.23516","journal-title":"J Bone Jt Surg Br"},{"key":"3550_CR4","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.knee.2012.09.011","volume":"21","author":"SW Bell","year":"2014","unstructured":"Bell SW, Young P, Drury C et al (2014) Component rotational alignment in unexplained painful primary total knee arthroplasty. Knee 21:272\u2013277. https:\/\/doi.org\/10.1016\/j.knee.2012.09.011","journal-title":"Knee"},{"issue":"260\u2013267","key":"3550_CR5","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1016\/j.arth.2010.03.015","volume":"26","author":"MP Bonnin","year":"2011","unstructured":"Bonnin MP, Saffarini M, Mercier P-E et al (2011) Is the anterior tibial tuberosity a reliable rotational landmark for the tibial component in total knee arthroplasty? J Arthroplast 26(260\u2013267):e1\u20132. https:\/\/doi.org\/10.1016\/j.arth.2010.03.015","journal-title":"J Arthroplast"},{"key":"3550_CR6","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s00402-017-2837-1","volume":"138","author":"S Mitsuhashi","year":"2018","unstructured":"Mitsuhashi S, Akamatsu Y, Kobayashi H et al (2018) Combined CT-based and image-free navigation systems in TKA reduces postoperative outliers of rotational alignment of the tibial component. Arch Orthop Trauma Surg 138:259\u2013266. https:\/\/doi.org\/10.1007\/s00402-017-2837-1","journal-title":"Arch Orthop Trauma Surg"},{"key":"3550_CR7","doi-asserted-by":"publisher","first-page":"1636","DOI":"10.1007\/s00167-017-4823-0","volume":"26","author":"AS Panni","year":"2018","unstructured":"Panni AS, Ascione F, Rossini M et al (2018) Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc 26:1636\u20131644. https:\/\/doi.org\/10.1007\/s00167-017-4823-0","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3550_CR8","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1007\/s11420-016-9491-y","volume":"12","author":"GC Wernecke","year":"2016","unstructured":"Wernecke GC, Harrris IA, Seeto BG et al (2016) Normal femorotibial rotational alignment and implications for total knee arthroplasty: an MRI analysis. HSS J 12:216\u2013222. https:\/\/doi.org\/10.1007\/s11420-016-9491-y","journal-title":"HSS J"},{"key":"3550_CR9","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1302\/0301-620X.90B8.19905","volume":"90","author":"JP Cobb","year":"2008","unstructured":"Cobb JP, Dixon H, Dandachli W, Iranpour F (2008) The anatomical tibial axis: reliable rotational orientation in knee replacement. J Bone Jt Surg Br 90:1032\u20131038. https:\/\/doi.org\/10.1302\/0301-620X.90B8.19905","journal-title":"J Bone Jt Surg Br"},{"key":"3550_CR10","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1302\/0301-620X.95B11.32765","volume":"95-B","author":"RD Scott","year":"2013","unstructured":"Scott RD (2013) Femoral and tibial component rotation in total knee arthroplasty: methods and consequences. Bone Jt J 95-B:140\u2013143. https:\/\/doi.org\/10.1302\/0301-620X.95B11.32765","journal-title":"Bone Jt J"},{"key":"3550_CR11","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/00003086-199402000-00011","volume":"299","author":"SJ Incavo","year":"1994","unstructured":"Incavo SJ, Ronchetti PJ, Howe JG, Tranowski JP (1994) Tibial plateau coverage in total knee arthroplasty. Clin Orthop Relat Res 299:81\u201385","journal-title":"Clin Orthop Relat Res"},{"key":"3550_CR12","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.arth.2008.05.020","volume":"23","author":"ME Berend","year":"2008","unstructured":"Berend ME, Ritter MA, Hyldahl HC et al (2008) Implant migration and failure in total knee arthroplasty is related to body mass index and tibial component size. J Arthroplast 23:104\u2013109. https:\/\/doi.org\/10.1016\/j.arth.2008.05.020","journal-title":"J Arthroplast"},{"key":"3550_CR13","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1016\/j.knee.2014.01.003","volume":"21","author":"MJ Hartel","year":"2014","unstructured":"Hartel MJ, Loosli Y, Delfosse D et al (2014) The influence of tibial morphology on the design of an anatomical tibial baseplate for TKA. Knee 21:415\u2013419. https:\/\/doi.org\/10.1016\/j.knee.2014.01.003","journal-title":"Knee"},{"key":"3550_CR14","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1007\/s11999-013-3047-y","volume":"472","author":"S Martin","year":"2014","unstructured":"Martin S, Saurez A, Ismaily S et al (2014) Maximizing tibial coverage is detrimental to proper rotational alignment. Clin Orthop Relat Res 472:121\u2013125. https:\/\/doi.org\/10.1007\/s11999-013-3047-y","journal-title":"Clin Orthop Relat Res"},{"key":"3550_CR15","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s00402-017-2850-4","volume":"138","author":"ME Simsek","year":"2018","unstructured":"Simsek ME, Akkaya M, Gursoy S et al (2018) Posterolateral overhang affects patient quality of life after total knee arthroplasty. Arch Orthop Trauma Surg 138:409\u2013418. https:\/\/doi.org\/10.1007\/s00402-017-2850-4","journal-title":"Arch Orthop Trauma Surg"},{"key":"3550_CR16","doi-asserted-by":"publisher","first-page":"2532","DOI":"10.1007\/s00167-015-3512-0","volume":"24","author":"MP Bonnin","year":"2016","unstructured":"Bonnin MP, Saffarini M, Shepherd D et al (2016) Oversizing the tibial component in TKAs: incidence, consequences and risk factors. Knee Surg Sports Traumatol Arthrosc 24:2532\u20132540. https:\/\/doi.org\/10.1007\/s00167-015-3512-0","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3550_CR17","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1007\/s001670050059","volume":"5","author":"P Lemaire","year":"1997","unstructured":"Lemaire P, Pioletti DP, Meyer FM et al (1997) Tibial component positioning in total knee arthroplasty: bone coverage and extensor apparatus alignment. Knee Surg Sports Traumatol Arthrosc 5:251\u2013257. https:\/\/doi.org\/10.1007\/s001670050059","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3550_CR18","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1007\/s11999-013-2800-6","volume":"471","author":"S Mori","year":"2013","unstructured":"Mori S, Akagi M, Asada S et al (2013) Tibia vara affects the aspect ratio of tibial resected surface in female Japanese patients undergoing TKA. Clin Orthop Relat Res 471:1465\u20131471. https:\/\/doi.org\/10.1007\/s11999-013-2800-6","journal-title":"Clin Orthop Relat Res"},{"key":"3550_CR19","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1186\/s13018-018-0957-0","volume":"13","author":"EA Wakelin","year":"2018","unstructured":"Wakelin EA, Tran L, Twiggs JG et al (2018) Accurate determination of post-operative 3D component positioning in total knee arthroplasty: the AURORA protocol. J Orthop Surg Res 13:275. https:\/\/doi.org\/10.1186\/s13018-018-0957-0","journal-title":"J Orthop Surg Res"},{"key":"3550_CR20","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.arth.2017.08.023","volume":"33","author":"JG Twiggs","year":"2018","unstructured":"Twiggs JG, Dickison DM, Kolos EC et al (2018) Patient variation limits use of fixed references for femoral rotation component alignment in total knee arthroplasty. J Arthroplasty 33:67\u201374. https:\/\/doi.org\/10.1016\/j.arth.2017.08.023","journal-title":"J Arthroplasty"},{"key":"3550_CR21","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s00264-015-2733-7","volume":"40","author":"J Hutt","year":"2016","unstructured":"Hutt J, Mass\u00e9 V, Lavigne M, Vendittoli P-A (2016) Functional joint line obliquity after kinematic total knee arthroplasty. Int Orthop 40:29\u201334. https:\/\/doi.org\/10.1007\/s00264-015-2733-7","journal-title":"Int Orthop"},{"key":"3550_CR22","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1016\/j.arth.2009.07.004","volume":"25","author":"D Lakstein","year":"2010","unstructured":"Lakstein D, Zarrabian M, Kosashvili Y et al (2010) Revision total knee arthroplasty for component malrotation is highly beneficial: a case control study. J Arthroplast 25:1047\u20131052. https:\/\/doi.org\/10.1016\/j.arth.2009.07.004","journal-title":"J Arthroplast"},{"key":"3550_CR23","doi-asserted-by":"publisher","first-page":"1658","DOI":"10.1002\/jor.22711","volume":"32","author":"S Kuriyama","year":"2014","unstructured":"Kuriyama S, Ishikawa M, Furu M et al (2014) Malrotated tibial component increases medial collateral ligament tension in total knee arthroplasty. J Orthop Res 32:1658\u20131666. https:\/\/doi.org\/10.1002\/jor.22711","journal-title":"J Orthop Res"},{"key":"3550_CR24","doi-asserted-by":"publisher","first-page":"2288","DOI":"10.1007\/s00167-012-1987-5","volume":"21","author":"SM Howell","year":"2013","unstructured":"Howell SM, Chen J, Hull ML (2013) Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 21:2288\u20132295. https:\/\/doi.org\/10.1007\/s00167-012-1987-5","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3550_CR25","doi-asserted-by":"publisher","first-page":"2734","DOI":"10.1007\/s11999-010-1330-8","volume":"468","author":"BP Graw","year":"2010","unstructured":"Graw BP, Harris AH, Tripuraneni KR, Giori NJ (2010) Rotational references for total knee arthroplasty tibial components change with level of resection. Clin Orthop Relat Res 468:2734\u20132738. https:\/\/doi.org\/10.1007\/s11999-010-1330-8","journal-title":"Clin Orthop Relat Res"},{"key":"3550_CR26","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-017-1609-y","author":"JI Kim","year":"2017","unstructured":"Kim JI, Jang J, Lee KW et al (2017) Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty. BMC Musculoskelet Disord. https:\/\/doi.org\/10.1186\/s12891-017-1609-y","journal-title":"BMC Musculoskelet Disord"},{"key":"3550_CR27","doi-asserted-by":"publisher","first-page":"155","DOI":"10.11138\/jts\/2013.1.4.1455","volume":"1","author":"A Baldini","year":"2013","unstructured":"Baldini A, Indelli PF, Luca DEL et al (2013) Rotational alignment of the tibial component in total knee arthroplasty: the anterior tibial cortex is a reliable landmark. Joints 1:155\u2013160","journal-title":"Joints"},{"key":"3550_CR28","doi-asserted-by":"publisher","first-page":"2751","DOI":"10.1007\/s11999-008-0452-8","volume":"466","author":"P Aglietti","year":"2008","unstructured":"Aglietti P, Sensi L, Cuomo P, Ciardullo A (2008) Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis. Clin Orthop Relat Res 466:2751\u20132755. https:\/\/doi.org\/10.1007\/s11999-008-0452-8","journal-title":"Clin Orthop Relat Res"},{"key":"3550_CR29","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1097\/01.blo.0000160027.52481.32","volume":"436","author":"M Akagi","year":"2005","unstructured":"Akagi M, Mori S, Nishimura S et al (2005) Variability of extraarticular tibial rotation references for total knee arthroplasty. Clin Orthop Relat Res 436:172\u2013176","journal-title":"Clin Orthop Relat Res"},{"key":"3550_CR30","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1007\/s00167-011-1606-x","volume":"20","author":"N Sahin","year":"2012","unstructured":"Sahin N, At\u0131c\u0131 T, \u00d6zt\u00fcrk A et al (2012) Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 20:565\u2013570. https:\/\/doi.org\/10.1007\/s00167-011-1606-x","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3550_CR31","doi-asserted-by":"publisher","first-page":"e015587","DOI":"10.1136\/bmjopen-2016-015587","volume":"7","author":"T Devji","year":"2017","unstructured":"Devji T, Guyatt GH, Lytvyn L et al (2017) Application of minimal important differences in degenerative knee disease outcomes: a systematic review and case study to inform BMJ rapid recommendations. BMJ Open 7:e015587. https:\/\/doi.org\/10.1136\/bmjopen-2016-015587","journal-title":"BMJ Open"},{"key":"3550_CR32","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1016\/S0268-0033(01)00109-7","volume":"17","author":"JJ Liau","year":"2002","unstructured":"Liau JJ, Cheng CK, Huang CH, Lo WH (2002) The effect of malalignment on stresses in polyethylene component of total knee prostheses\u2013a finite element analysis. Clin Biomech (Bristol, Avon) 17:140\u2013146","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"3550_CR33","doi-asserted-by":"publisher","first-page":"2911","DOI":"10.1007\/s00167-014-3282-0","volume":"22","author":"Y Dai","year":"2014","unstructured":"Dai Y, Scuderi GR, Bischoff JE et al (2014) Anatomic tibial component design can increase tibial coverage and rotational alignment accuracy: a comparison of six contemporary designs. Knee Surg Sports Traumatol Arthrosc 22:2911\u20132923. https:\/\/doi.org\/10.1007\/s00167-014-3282-0","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3550_CR34","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1007\/s00402-017-2828-2","volume":"138","author":"Y Ma","year":"2018","unstructured":"Ma Y, Mizu-Uchi H, Okazaki K et al (2018) Effects of tibial baseplate shape on rotational alignment in total knee arthroplasty: three-dimensional surgical simulation using osteoarthritis knees. Arch Orthop Trauma Surg 138:105\u2013114. https:\/\/doi.org\/10.1007\/s00402-017-2828-2","journal-title":"Arch Orthop Trauma Surg"},{"key":"3550_CR35","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1016\/j.arth.2017.12.027","volume":"33","author":"CS Nielsen","year":"2018","unstructured":"Nielsen CS, Nebergall A, Huddleston J et al (2018) Medial overhang of the tibial component is associated with higher risk of inferior knee injury and osteoarthritis outcome score pain after knee replacement. J Arthroplast 33:1394\u20131398. https:\/\/doi.org\/10.1016\/j.arth.2017.12.027","journal-title":"J Arthroplast"},{"key":"3550_CR36","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1016\/j.knee.2014.05.010","volume":"21","author":"SGF Abram","year":"2014","unstructured":"Abram SGF, Marsh AG, Brydone AS et al (2014) The effect of tibial component sizing on patient reported outcome measures following uncemented total knee replacement. Knee 21:955\u2013959. https:\/\/doi.org\/10.1016\/j.knee.2014.05.010","journal-title":"Knee"},{"key":"3550_CR37","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.knee.2012.10.009","volume":"21","author":"TJ Heyse","year":"2014","unstructured":"Heyse TJ, Tibesku CO (2014) Improved femoral component rotation in TKA using patient-specific instrumentation. Knee 21:268\u2013271. https:\/\/doi.org\/10.1016\/j.knee.2012.10.009","journal-title":"Knee"},{"key":"3550_CR38","doi-asserted-by":"publisher","first-page":"1767","DOI":"10.1007\/s00167-017-4778-1","volume":"26","author":"TJ Heyse","year":"2018","unstructured":"Heyse TJ, El-Zayat BF, De Corte R et al (2018) Internal femoral component malrotation in TKA significantly alters tibiofemoral kinematics. Knee Surg Sports Traumatol Arthrosc 26:1767\u20131775. https:\/\/doi.org\/10.1007\/s00167-017-4778-1","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"3550_CR39","doi-asserted-by":"publisher","first-page":"1561","DOI":"10.1007\/s00264-017-3490-6","volume":"41","author":"AJ Nedopil","year":"2017","unstructured":"Nedopil AJ, Howell SM, Hull ML (2017) What mechanisms are associated with tibial component failure after kinematically-aligned total knee arthroplasty? Int Orthop 41:1561\u20131569. https:\/\/doi.org\/10.1007\/s00264-017-3490-6","journal-title":"Int Orthop"},{"key":"3550_CR40","unstructured":"National Joint Replacement Registry AOA (2019) 2019 Hip, knee and shoulder arthroplasty annual report. https:\/\/aoanjrr.sahmri.com\/documents\/10180\/668596\/Hip%2C+Knee+%26+Shoulder+Arthroplasty\/c287d2a3-22df-a3bb-37a2-91e6c00bfcf0"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-020-03550-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-020-03550-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-020-03550-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,5]],"date-time":"2022-11-05T15:55:19Z","timestamp":1667663719000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-020-03550-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,3]]},"references-count":40,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["3550"],"URL":"https:\/\/doi.org\/10.1007\/s00402-020-03550-z","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,3]]},"assertion":[{"value":"10 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Antonio Klasan has received research support from Implantcast. Joshua Twiggs is an employee of 360 Knee Systems. Brett Fritsch has been paid for presentations by and is a consultant for Arthrex and Omni. He has stock options in 360 Knee Systems, he has received research support from Arthrex, Smith & Nephew and Zimmer. Brad Miles has Stock Options in 360 Knee Systems. Thomas Heyse has been paid for presentations by Smith & Nephew, Zimmer Biomet and Implantcast, he has received research support from Smith & Nephew, Zimmer Biomet and Implantcast and he is a consultant to Smith & Nephew. Michael Solomon receives royalties from Corin and Medacta, has been paid for presentations and received research support from Corin. David Parker has been paid for presentations by Arthrex and Smith & Nephew, he is a consultant for Arthrex and Global, has stock options in 360 Knee Systems and Trium.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}