{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T09:08:07Z","timestamp":1769504887687,"version":"3.49.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2020,10,12]],"date-time":"2020-10-12T00:00:00Z","timestamp":1602460800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,10,12]],"date-time":"2020-10-12T00:00:00Z","timestamp":1602460800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Berufsgenossenschaftliches Klinikum Bergmannsheil gGmbH"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2021,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Introduction<\/jats:title>\n                <jats:p>Among the few techniques described for the treatment of coronoid fractures, osteosynthesis techniques include screw osteosynthesis from anterior to posterior (AP) or from posterior to anterior (PA) and plate osteosynthesis. The aim of this study was to test the biomechanical stability of screw osteosynthesis and plate osteosynthesis using anatomical plates in coronoid process fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>On a total of 25 biomechanical synthetical ulnae, a coronoid shear fracture including 70% of the coronoid height was simulated. Osteosynthesis was then performed using two 2.7\u00a0mm screws from anterior, posterior and with use of three different anatomical plates of the coronoid process. For the biomechanical testing, axial load was applied to the fragment with 1000 cycles from 5 to 250\u00a0N, load to failure and load at 100\u00a0\u00b5m displacement. Displacements were measured using a point-based three-dimensional motion analysis system.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Osteosynthesis using the PA-screw showed significant more displacement during cyclic loading compared with all other osteosyntheses (0.99\u00a0mm), whereas AP-screw showed the smallest displacement (0.10\u00a0mm) during cyclic loading. The PA-screw technique showed a significant lower load to failure compared to all other osteosynthesis with the highest load in AP-screw osteosynthesis. The load for 100\u00a0\u00b5m displacement was the smallest in PA-screw with a significant difference to the AP-screw and one plate osteosynthesis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Osteosynthesis of large coronoid shear fractures with two small-fragment screws from anterior allows stable fixation that is not inferior to anterior plate osteosynthesis and might be an alternative in specific fracture types. Posterior screw fixation was found as the weakest fixation method.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>Basic science study<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00402-020-03621-1","type":"journal-article","created":{"date-parts":[[2020,10,12]],"date-time":"2020-10-12T09:02:58Z","timestamp":1602493378000},"page":"1509-1515","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Biomechanical comparison of screw osteosyntheses and anatomical plating for coronoid shear fractures of the ulna"],"prefix":"10.1007","volume":"141","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7987-5173","authenticated-orcid":false,"given":"Valentin","family":"Rausch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Birger","family":"Jettkant","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Lotzien","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Rosteius","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eileen","family":"Mempel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas A.","family":"Schildhauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominik","family":"Seybold","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Ge\u00dfmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"K\u00f6nigshausen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,10,12]]},"reference":[{"key":"3621_CR1","doi-asserted-by":"publisher","first-page":"1749","DOI":"10.2106\/00004623-200012000-00009","volume":"82","author":"RF Closkey","year":"2000","unstructured":"Closkey RF, Goode JR, Kirschenbaum D, Cody RP (2000) The role of the coronoid process in elbow stability: a biomechanical analysis of axial loading. J Bone Jt Surg Ser A 82:1749\u20131753. https:\/\/doi.org\/10.2106\/00004623-200012000-00009","journal-title":"J Bone Jt Surg Ser A"},{"key":"3621_CR2","doi-asserted-by":"publisher","first-page":"1348","DOI":"10.2106\/00004623-198971090-00011","volume":"71","author":"W Regan","year":"1989","unstructured":"Regan W, Morrey B (1989) Fractures of the coronoid process of the ulna. J Bone Jt Surg Am 71:1348\u20131354","journal-title":"J Bone Jt Surg Am"},{"key":"3621_CR3","first-page":"113","volume":"52","author":"SW O\u2019Driscoll","year":"2003","unstructured":"O\u2019Driscoll SW, Jupiter JB, Cohen MS et al (2003) Difficult elbow fractures: pearls and pitfalls. Instr Course Lect 52:113\u2013134","journal-title":"Instr Course Lect"},{"key":"3621_CR4","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.jse.2004.04.012","volume":"14","author":"J Sanchez-Sotelo","year":"2005","unstructured":"Sanchez-Sotelo J, O\u2019Driscoll SW, Morrey BF (2005) Medial oblique compression fracture of the coronoid process of the ulna. J Shoulder Elb Surg 14:60\u201364. https:\/\/doi.org\/10.1016\/j.jse.2004.04.012","journal-title":"J Shoulder Elb Surg"},{"key":"3621_CR5","doi-asserted-by":"publisher","first-page":"2216","DOI":"10.2106\/JBJS.E.01127","volume":"88","author":"JN Doornberg","year":"2006","unstructured":"Doornberg JN, Ring DC (2006) Fracture of the anteromedial facet of the coronoid process. J Bone Jt Surg Am 88:2216\u20132224. https:\/\/doi.org\/10.2106\/JBJS.E.01127","journal-title":"J Bone Jt Surg Am"},{"key":"3621_CR6","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1016\/j.jse.2016.02.025","volume":"25","author":"K Chan","year":"2016","unstructured":"Chan K, Faber KJ, King GJW, Athwal GS (2016) Selected anteromedial coronoid fractures can be treated nonoperatively. J Shoulder Elb Surg 25:1251\u20131257. https:\/\/doi.org\/10.1016\/j.jse.2016.02.025","journal-title":"J Shoulder Elb Surg"},{"key":"3621_CR7","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1302\/0301-620X.91B5.21755","volume":"91","author":"JE Adams","year":"2009","unstructured":"Adams JE, Hoskin TL, Morrey BF, Steinmann SP (2009) Management and outcome of 103 acute fractures of the coronoid process of the ulna. J Bone Joint Surg Br 91:632\u2013635. https:\/\/doi.org\/10.1302\/0301-620X.91B5.21755","journal-title":"J Bone Joint Surg Br"},{"key":"3621_CR8","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1097\/BOT.0b013e31819df8c9","volume":"23","author":"J-G Moon","year":"2009","unstructured":"Moon J-G, Zobitz ME, An K-N, O\u2019Driscoll SW (2009) Optimal screw orientation for fixation of coronoid fractures. J Orthop Trauma 23:277\u2013280. https:\/\/doi.org\/10.1097\/BOT.0b013e31819df8c9","journal-title":"J Orthop Trauma"},{"key":"3621_CR9","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1097\/BOT.0000000000001266","volume":"32","author":"J Morellato","year":"2018","unstructured":"Morellato J, Hons M, Louati H et al (2018) Fixation of anteromedial coronoid facet fractures: a biomechanical evaluation of plated versus screw constructs. J Orthop Trauma 32:451\u2013456. https:\/\/doi.org\/10.1097\/BOT.0000000000001266","journal-title":"J Orthop Trauma"},{"key":"3621_CR10","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1016\/j.jhsa.2006.08.020","volume":"31A","author":"D Ring","year":"2006","unstructured":"Ring D (2006) Fractures of the coronoid process of the Ulna. J Hand Surg Am 31A:1679\u20131689","journal-title":"J Hand Surg Am"},{"key":"3621_CR11","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1007\/s00776-003-0735-6","volume":"9","author":"H Wake","year":"2004","unstructured":"Wake H, Hashizume H, Nishida K et al (2004) Biomechanical analysis of the mechanism of elbow fracture-dislocations by compression force. J Orthop Sci 9:44\u201350. https:\/\/doi.org\/10.1007\/s00776-003-0735-6","journal-title":"J Orthop Sci"},{"key":"3621_CR12","doi-asserted-by":"publisher","first-page":"2068","DOI":"10.1007\/s11999-014-3477-1","volume":"472","author":"RU Hartzler","year":"2014","unstructured":"Hartzler RU, Llusa-Perez M, Steinmann SP et al (2014) Transverse coronoid fracture: When does it have to be fixed? Clin Orthop Relat Res 472:2068\u20132074. https:\/\/doi.org\/10.1007\/s11999-014-3477-1","journal-title":"Clin Orthop Relat Res"},{"key":"3621_CR13","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1177\/0363546510364053","volume":"86","author":"AG Schneeberger","year":"2004","unstructured":"Schneeberger AG, Sadowski MM, Jacob HAC (2004) Coronoid process and radial head as posterolateral rotatory stabilizers of the elbow. J Bone Joint Surg Am 86:975\u2013982. https:\/\/doi.org\/10.1177\/0363546510364053","journal-title":"J Bone Joint Surg Am"},{"key":"3621_CR14","doi-asserted-by":"publisher","first-page":"1448","DOI":"10.2106\/JBJS.H.00222","volume":"91","author":"JW Pollock","year":"2009","unstructured":"Pollock JW, Brownhill J, Ferreira L et al (2009) The effect of anteromedial facet fractures of the coronoid and lateral collateral ligament injury on elbow stability and kinematics. J Bone Jt Surg Ser A 91:1448\u20131458. https:\/\/doi.org\/10.2106\/JBJS.H.00222","journal-title":"J Bone Jt Surg Ser A"},{"key":"3621_CR15","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.jse.2004.09.032","volume":"14","author":"MR Safran","year":"2005","unstructured":"Safran MR, Baillargeon D (2005) Soft-tissue stabilizers of the elbow. J Shoulder Elb Surg 14:179\u2013185. https:\/\/doi.org\/10.1016\/j.jse.2004.09.032","journal-title":"J Shoulder Elb Surg"},{"key":"3621_CR16","doi-asserted-by":"publisher","first-page":"2308","DOI":"10.1007\/s11999-017-5348-z","volume":"475","author":"IH Rhyou","year":"2017","unstructured":"Rhyou IH, Lee JH, Kim KC et al (2017) What Injury mechanism and patterns of ligament status are associated with isolated coronoid, isolated radial head, and combined fractures? Clin Orthop Relat Res 475:2308\u20132315. https:\/\/doi.org\/10.1007\/s11999-017-5348-z","journal-title":"Clin Orthop Relat Res"},{"key":"3621_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2018.08.006","author":"V Rausch","year":"2018","unstructured":"Rausch V, Wegmann S, Hackl M et al (2018) Insertional anatomy of the anterior medial collateral ligament on the sublime tubercle of the elbow. J Shoulder Elb Surg. https:\/\/doi.org\/10.1016\/j.jse.2018.08.006","journal-title":"J Shoulder Elb Surg"},{"key":"3621_CR18","doi-asserted-by":"publisher","first-page":"307","DOI":"10.3944\/AOTT.2015.14.0183","volume":"49","author":"O Hapa","year":"2015","unstructured":"Hapa O, Karakasli A, Dincer C et al (2015) Biomechanical comparison of headless antegrade screw versus retrograde cortical screw for coronoid fracture fixation. Acta Orthop Traumatol Turc 49:307\u2013310. https:\/\/doi.org\/10.3944\/AOTT.2015.14.0183","journal-title":"Acta Orthop Traumatol Turc"},{"key":"3621_CR19","doi-asserted-by":"publisher","first-page":"e11","DOI":"10.1016\/j.jhsa.2016.11.003","volume":"42","author":"NP Iannuzzi","year":"2017","unstructured":"Iannuzzi NP, Paez AG, Parks BG, Murphy MS (2017) Fixation of regan-morrey type II coronoid fractures: a comparison of screws and suture lasso technique for resistance to displacement. J Hand Surg Am 42:e11\u2013e14. https:\/\/doi.org\/10.1016\/j.jhsa.2016.11.003","journal-title":"J Hand Surg Am"},{"key":"3621_CR20","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.jhsa.2010.10.022","volume":"36","author":"JE Budoff","year":"2011","unstructured":"Budoff JE, Meyers DN, Ambrose CG (2011) The comparative stability of screw versus plate versus screw and plate coronoid fixation. J Hand Surg Am 36:238\u2013245. https:\/\/doi.org\/10.1016\/j.jhsa.2010.10.022","journal-title":"J Hand Surg Am"},{"key":"3621_CR21","doi-asserted-by":"publisher","first-page":"1873","DOI":"10.2106\/JBJS.I.01673","volume":"93","author":"GE Garrigues","year":"2011","unstructured":"Garrigues GE, Wray WH, Lindenhovius ALC et al (2011) Fixation of the coronoid process in elbow fracture-dislocations. J Bone Jt Surg Ser A 93:1873\u20131881. https:\/\/doi.org\/10.2106\/JBJS.I.01673","journal-title":"J Bone Jt Surg Ser A"},{"key":"3621_CR22","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1016\/0021-9290(81)90048-8","volume":"14","author":"KN An","year":"1981","unstructured":"An KN, Hui FC, Morrey BF et al (1981) Muscles across the elbow joint: a biomechanical analysis. J Biomech 14:659\u2013669","journal-title":"J Biomech"},{"key":"3621_CR23","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(80)90238-9","author":"AA Amis","year":"1980","unstructured":"Amis AA, Dowson D, Wright V (1980) Elbow joint force predictions for some strenuous isometric actions. J Biomech. https:\/\/doi.org\/10.1016\/0021-9290(80)90238-9","journal-title":"J Biomech"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-020-03621-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-020-03621-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-020-03621-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,12]],"date-time":"2021-10-12T09:07:14Z","timestamp":1634029634000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-020-03621-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,12]]},"references-count":23,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2021,9]]}},"alternative-id":["3621"],"URL":"https:\/\/doi.org\/10.1007\/s00402-020-03621-1","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,12]]},"assertion":[{"value":"22 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All osteosynthetic material was provided by the respective manufacturer. No other conflicts of interest are declared by the authors.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}