{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T12:46:33Z","timestamp":1782909993276,"version":"3.54.5"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2021,7,13]],"date-time":"2021-07-13T00:00:00Z","timestamp":1626134400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,7,13]],"date-time":"2021-07-13T00:00:00Z","timestamp":1626134400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s00402-021-04039-z","type":"journal-article","created":{"date-parts":[[2021,7,13]],"date-time":"2021-07-13T10:24:13Z","timestamp":1626171853000},"page":"2175-2184","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["Joint line is restored in robotic-arm-assisted total knee arthroplasty performed with a tibia-based functional alignment"],"prefix":"10.1007","volume":"141","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7634-5692","authenticated-orcid":false,"given":"Francesco","family":"Zambianchi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriele","family":"Bazzan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Marcovigi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Pavesi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Illuminati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Ensini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabio","family":"Catani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,7,13]]},"reference":[{"issue":"7","key":"4039_CR1","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1007\/s00167-019-05558-4","volume":"27","author":"MT Hirschmann","year":"2019","unstructured":"Hirschmann MT, Becker R, Tandogan R, Vendittoli PA, Howell S (2019) Alignment in TKA: what has been clear is not anymore! Knee Surg Sports Traumatol Arthrosc 27(7):2037\u20132039. https:\/\/doi.org\/10.1007\/s00167-019-05558-4","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"4039_CR2","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1097\/00003086-198501000-00003","volume":"192","author":"JN Insall","year":"1985","unstructured":"Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13\u201322. https:\/\/doi.org\/10.1097\/00003086-198501000-00003","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"4039_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1302\/2058-5241.3.170021","volume":"3","author":"C Rivi\u00e8re","year":"2018","unstructured":"Rivi\u00e8re C, Lazic S, Boughton O, Wiart Y, V\u00efllet L, Cobb J (2018) Current concepts for aligning knee implants: patient-specific or systematic? EFORT Open Rev 3(1):1\u20136. https:\/\/doi.org\/10.1302\/2058-5241.3.170021","journal-title":"EFORT Open Rev"},{"issue":"3","key":"4039_CR4","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.1007\/s11999-012-2613-z","volume":"471","author":"SM Howell","year":"2013","unstructured":"Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471(3):1000\u20131007. https:\/\/doi.org\/10.1007\/s11999-012-2613-z","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"4039_CR5","doi-asserted-by":"publisher","first-page":"1368","DOI":"10.1007\/s00167-019-05506-2","volume":"27","author":"S Hess","year":"2019","unstructured":"Hess S, Moser LB, Amsler F, Behrend H, Hirschmann MT (2019) Highly variable coronal tibial and femoral alignment in osteoarthritic knees: a systematic review. Knee Surg Sports Traumatol Arthrosc 27(5):1368\u20131377. https:\/\/doi.org\/10.1007\/s00167-019-05506-2","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"5","key":"4039_CR6","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.1007\/s00167-019-05562-8","volume":"28","author":"W Blakeney","year":"2020","unstructured":"Blakeney W, Beaulieu Y, Puliero B, Kiss MO, Vendittoli PA (2020) Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances. Knee Surg Sports Traumatol Arthrosc 28(5):1532\u20131541. https:\/\/doi.org\/10.1007\/s00167-019-05562-8","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"4039_CR7","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1302\/0301-620X.102B1.BJJ-2019-0674.R2","volume":"102-B","author":"SJ MacDessi","year":"2020","unstructured":"MacDessi SJ, Griffiths-Jones W, Chen DB, Griffiths-Jones S, Wood JA, Diwan AD, Harris IA (2020) Restoring the constitutional alignment with a restrictive kinematic protocol improves quantitative soft-tissue balance in total knee arthroplasty: a randomized controlled trial. Bone Joint J. 102-B(1):117\u2013124. https:\/\/doi.org\/10.1302\/0301-620X.102B1.BJJ-2019-0674.R2","journal-title":"Bone Joint J."},{"key":"4039_CR8","doi-asserted-by":"publisher","first-page":"2872","DOI":"10.1016\/j.arth.2020.05.065","volume":"35","author":"A Klasan","year":"2020","unstructured":"Klasan A, de Steiger R, Holland S, Hatton A, Vertullo CJ, Young SW (2020) Similar risk of revision after kinematically aligned, patient-specific instrumented total knee arthroplasty, and all other total knee arthroplasty: combined results from the Australian and New Zealand joint replacement registries. J Arthroplasty 35:2872\u20132877. https:\/\/doi.org\/10.1016\/j.arth.2020.05.065","journal-title":"J Arthroplasty"},{"issue":"6","key":"4039_CR9","doi-asserted-by":"publisher","first-page":"1610","DOI":"10.1007\/s00167-017-4765-6","volume":"26","author":"MG Teeter","year":"2018","unstructured":"Teeter MG, Naudie DD, McCalden RW, Yuan X, Holdsworth DW, MacDonald SJ, Lanting BA (2018) Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 26(6):1610\u20131617. https:\/\/doi.org\/10.1007\/s00167-017-4765-6","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"4039_CR10","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.arth.2015.07.038","volume":"31","author":"B Innocenti","year":"2016","unstructured":"Innocenti B, Bellemans J, Catani F (2016) Deviations from optimal alignment in TKA: is there a biomechanical difference between femoral or tibial component alignment? J Arthroplasty 31(1):295\u2013301. https:\/\/doi.org\/10.1016\/j.arth.2015.07.038","journal-title":"J Arthroplasty"},{"issue":"7","key":"4039_CR11","doi-asserted-by":"publisher","first-page":"2133","DOI":"10.1016\/j.arth.2017.02.028","volume":"32","author":"AM Almaawi","year":"2017","unstructured":"Almaawi AM, Hutt JRB, Masse V, Lavigne M, Vendittoli PA (2017) The impact of mechanical and restricted kinematic alignment on knee anatomy in total knee arthroplasty. J Arthroplasty 32(7):2133\u20132140. https:\/\/doi.org\/10.1016\/j.arth.2017.02.028","journal-title":"J Arthroplasty"},{"issue":"7","key":"4039_CR12","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1016\/j.otsr.2017.07.010","volume":"103","author":"C Rivi\u00e8re","year":"2017","unstructured":"Rivi\u00e8re C, Iranpour F, Auvinet E, Howell S, Vendittoli PA, Cobb J, Parratte S (2017) Alignment options for total knee arthroplasty: a systematic review. Orthop Traumatol Surg Res 103(7):1047\u20131056. https:\/\/doi.org\/10.1016\/j.otsr.2017.07.010","journal-title":"Orthop Traumatol Surg Res"},{"issue":"3","key":"4039_CR13","doi-asserted-by":"publisher","first-page":"966","DOI":"10.1007\/s00167-020-06056-8","volume":"29","author":"F Zambianchi","year":"2021","unstructured":"Zambianchi F, Giorgini A, Ensini A, Lombari V, Daffara V, Catani F (2021) Navigated, soft tissue-guided total knee arthroplasty restores the distal femoral joint line orientation in a modified mechanically aligned technique. Knee Surg Sports Traumatol Arthrosc 29(3):966\u2013974. https:\/\/doi.org\/10.1007\/s00167-020-06056-8","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"10","key":"4039_CR14","doi-asserted-by":"publisher","first-page":"1533","DOI":"10.1007\/s00402-020-03512-5","volume":"140","author":"JR Onggo","year":"2020","unstructured":"Onggo JR, Onggo JD, de Steiger R, Hau R (2020) Robotic-assisted total knee arthroplasty is comparable to conventional total knee arthroplasty: a meta-analysis and systematic review. Arch Orthop Trauma Surg 140(10):1533\u20131549. https:\/\/doi.org\/10.1007\/s00402-020-03512-5","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"4039_CR15","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1302\/0301-620X.102B3.BJJ-2019-1729","volume":"102-B","author":"S Oussedik","year":"2020","unstructured":"Oussedik S, Abdel MP, Victor J, Pagnano MW, Haddad FS (2020) Alignment in total knee arthroplasty. Bone Joint J 102-B(3):276\u2013279. https:\/\/doi.org\/10.1302\/0301-620X.102B3.BJJ-2019-1729","journal-title":"Bone Joint J"},{"issue":"1","key":"4039_CR16","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1186\/s13063-020-4123-8","volume":"21","author":"B Kayani","year":"2020","unstructured":"Kayani B, Konan S, Tahmassebi J, Oussedik S, Moriarty PD, Haddad FS (2020) A prospective double-blinded randomised control trial comparing robotic arm-assisted functionally aligned total knee arthroplasty versus robotic arm-assisted mechanically aligned total knee arthroplasty. Trials 21(1):194. https:\/\/doi.org\/10.1186\/s13063-020-4123-8","journal-title":"Trials"},{"issue":"3","key":"4039_CR17","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1302\/0301-620X.103B.BJJ-2020-0940.R1","volume":"103-B","author":"JS Chang","year":"2021","unstructured":"Chang JS, Kayani B, Wallace C, Haddad FS (2021) Functional alignment achieves soft-tissue balance in total knee arthroplasty as measured with quantitative sensor-guided technology. Bone Joint J. 103-B(3):507\u2013514. https:\/\/doi.org\/10.1302\/0301-620X.103B.BJJ-2020-0940.R1","journal-title":"Bone Joint J."},{"issue":"5","key":"4039_CR18","doi-asserted-by":"publisher","first-page":"1378","DOI":"10.1007\/s00167-019-05507-1","volume":"27","author":"MT Hirschmann","year":"2019","unstructured":"Hirschmann MT, Hess S, Behrend H, Amsler F, Leclercq V, Moser LB (2019) Phenotyping of hip-knee-ankle angle in young non-osteoarthritic knees provides better understanding of native alignment variability. Knee Surg Sports Traumatol Arthrosc 27(5):1378\u20131384. https:\/\/doi.org\/10.1007\/s00167-019-05507-1","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"4039_CR19","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1007\/s00167-020-06052-y","volume":"29","author":"M Meier","year":"2021","unstructured":"Meier M, Janssen D, Koeck FX, Thienpont E, Beckmann J, Best R (2021) Variations in medial and lateral slope and medial proximal tibial angle. Knee Surg Sports Traumatol Arthrosc 29(3):939\u2013946. https:\/\/doi.org\/10.1007\/s00167-020-06052-y","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"8","key":"4039_CR20","doi-asserted-by":"publisher","first-page":"2496","DOI":"10.1016\/j.arth.2018.03.042","volume":"33","author":"B Kayani","year":"2018","unstructured":"Kayani B, Konan S, Pietrzak JRT, Haddad FS (2018) Iatrogenic bone and soft tissue trauma in robotic-arm assisted total knee arthroplasty compared with conventional jig-based total knee arthroplasty: a prospective cohort study and validation of a new classification system. J Arthroplasty 33(8):2496\u20132501. https:\/\/doi.org\/10.1016\/j.arth.2018.03.042","journal-title":"J Arthroplasty"},{"issue":"10","key":"4039_CR21","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.1302\/0301-620X.101B10.BJJ-2018-1428.R2","volume":"101-B","author":"B Kayani","year":"2019","unstructured":"Kayani B, Konan S, Horriat S, Ibrahim MS, Haddad FS (2019) Posterior cruciate ligament resection in total knee arthroplasty: the effect on flexion-extension gaps, mediolateral laxity, and fixed flexion deformity. Bone Joint J. 101-B(10):1230\u20131237. https:\/\/doi.org\/10.1302\/0301-620X.101B10.BJJ-2018-1428.R2","journal-title":"Bone Joint J."},{"key":"4039_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06165-4","author":"P Winnock de Grave","year":"2020","unstructured":"Winnock de Grave P, Luyckx T, Claeys K, Tampere T, Kellens J, M\u00fcller J, Gunst P (2020) Higher satisfaction after total knee arthroplasty using restricted inverse kinematic alignment compared to adjusted mechanical alignment. Knee Surg Sports Traumatol Arthrosc. https:\/\/doi.org\/10.1007\/s00167-020-06165-4","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"17","key":"4039_CR23","doi-asserted-by":"publisher","first-page":"1588","DOI":"10.2106\/JBJS.J.00772","volume":"93","author":"MA Ritter","year":"2011","unstructured":"Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA (2011) The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am 93(17):1588\u20131596. https:\/\/doi.org\/10.2106\/JBJS.J.00772","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"4039_CR24","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1302\/0301-620X.101B8.BJJ-2018-0755.R3","volume":"101","author":"EK Laende","year":"2019","unstructured":"Laende EK, Richardson CG, Dunbar MJ (2019) A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty. Bone Joint J 101(8):929\u2013940. https:\/\/doi.org\/10.1302\/0301-620X.101B8.BJJ-2018-0755.R3","journal-title":"Bone Joint J"},{"key":"4039_CR25","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06427-1","author":"G Laforest","year":"2021","unstructured":"Laforest G, Kostretzis L, Kiss MO, Vendittoli PA (2021) Restricted kinematic alignment leads to uncompromised osseointegration of cementless total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. https:\/\/doi.org\/10.1007\/s00167-020-06427-1","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"12","key":"4039_CR26","doi-asserted-by":"publisher","first-page":"2373","DOI":"10.1016\/j.arth.2013.12.010","volume":"29","author":"MH Liow","year":"2014","unstructured":"Liow MH, Xia Z, Wong MK, Tay KJ, Yeo SJ, Chin PL (2014) Robot-assisted total knee arthroplasty accurately restores the joint line and mechanical axis. A prospective randomised study. J Arthroplasty 29(12):2373\u20132377. https:\/\/doi.org\/10.1016\/j.arth.2013.12.010","journal-title":"J Arthroplasty"},{"issue":"3","key":"4039_CR27","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1007\/s11999.0000000000000067","volume":"476","author":"T Luyckx","year":"2018","unstructured":"Luyckx T, Vandenneucker H, Ing LS, Vereecke E, Ing AV, Victor J (2018) Raising the joint line in TKA is associated with mid-flexion laxity: a study in cadaver knees. Clin Orthop Relat Res 476(3):601\u2013611. https:\/\/doi.org\/10.1007\/s11999.0000000000000067","journal-title":"Clin Orthop Relat Res"},{"issue":"12","key":"4039_CR28","doi-asserted-by":"publisher","first-page":"101","DOI":"10.2106\/JBJS.M.00306","volume":"96","author":"Y Gu","year":"2014","unstructured":"Gu Y, Roth JD, Howell SM, Hull ML (2014) How frequently do four methods for mechanically aligning a total knee arthroplasty cause collateral ligament imbalance and change alignment from normal in white patients? AAOS exhibit selection. J Bone Joint Surg Am 96(12):101. https:\/\/doi.org\/10.2106\/JBJS.M.00306","journal-title":"J Bone Joint Surg Am"},{"key":"4039_CR29","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06283-z","author":"C Batailler","year":"2020","unstructured":"Batailler C, Fernandez A, Swan J, Servien E, Haddad FS, Catani F, Lustig S (2020) MAKO CT-based robotic arm-assisted system is a reliable procedure for total knee arthroplasty: a systematic review. Knee Surg Sports Traumatol Arthrosc. https:\/\/doi.org\/10.1007\/s00167-020-06283-z","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"4","key":"4039_CR30","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1007\/s00167-018-5138-5","volume":"27","author":"B Kayani","year":"2019","unstructured":"Kayani B, Konan S, Huq SS, Tahmassebi J, Haddad FS (2019) Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning. Knee Surg Sports Traumatol Arthrosc 27(4):1132\u20131141. https:\/\/doi.org\/10.1007\/s00167-018-5138-5","journal-title":"Knee Surg Sports Traumatol Arthrosc"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-021-04039-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-021-04039-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-021-04039-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,16]],"date-time":"2021-11-16T13:12:46Z","timestamp":1637068366000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-021-04039-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,13]]},"references-count":30,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["4039"],"URL":"https:\/\/doi.org\/10.1007\/s00402-021-04039-z","relation":{},"ISSN":["0936-8051","1434-3916"],"issn-type":[{"value":"0936-8051","type":"print"},{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,13]]},"assertion":[{"value":"21 March 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors Francesco Zambianchi, Gabriele Bazzan, Andrea Marcovigi, Andrea Illuminati and Andrea Ensini or any member of their immediate family, have no funding or commercial associations (e.g. consultancies, stock ownership, equity interest, patent\/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article. The author Marco Pavesi is a paid employee of Ab Medica S.p.A. The author Fabio Catani reports consultancy and speaking fees, royalties, and fees for participation in review activities from Stryker and consultancy fees from Adler.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Given the retrospective nature of the study, which was conducted on already available data and without involving subjects, Ethics Approval was not necessary.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}]}}