{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T18:57:25Z","timestamp":1773601045497,"version":"3.50.1"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T00:00:00Z","timestamp":1630281600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T00:00:00Z","timestamp":1630281600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Lindenhof Foundation"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"published-print":{"date-parts":[[2022,8]]},"DOI":"10.1007\/s00402-021-04137-y","type":"journal-article","created":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T18:06:52Z","timestamp":1630346812000},"page":"1963-1970","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Novel press-fit technique of patellar bone plug in anterior cruciate ligament reconstruction is comparable to interference screw fixation"],"prefix":"10.1007","volume":"142","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4265-0795","authenticated-orcid":false,"given":"Janosch","family":"H\u00e4berli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian","family":"Heilgemeir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Valet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ameet","family":"Aiyangar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tom","family":"Overes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Henle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Eggli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,8,30]]},"reference":[{"key":"4137_CR1","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1007\/s00402-020-03347-0","volume":"140","author":"M Wenning","year":"2020","unstructured":"Wenning M, Heitner AH, Mauch M et al (2020) The effect of meniscal repair on strength deficits 6 months after ACL reconstruction. Arch Orthop Trauma Surg 140:751\u2013760. https:\/\/doi.org\/10.1007\/s00402-020-03347-0","journal-title":"Arch Orthop Trauma Surg"},{"key":"4137_CR2","doi-asserted-by":"publisher","first-page":"1850","DOI":"10.1007\/s00167-020-06231-x","volume":"29","author":"L Yan","year":"2021","unstructured":"Yan L, Li JJ, Zhu Y et al (2021) Interference screws are more likely to perform better than cortical button and cross-pin fixation for hamstring autograft in ACL reconstruction: a Bayesian network meta-analysis. Knee Surg, Sport Traumatol Arthrosc 29:1850\u20131861. https:\/\/doi.org\/10.1007\/s00167-020-06231-x","journal-title":"Knee Surg, Sport Traumatol Arthrosc"},{"key":"4137_CR3","doi-asserted-by":"publisher","first-page":"e53","DOI":"10.1016\/j.asmr.2019.10.001","volume":"2","author":"FA Barber","year":"2020","unstructured":"Barber FA, Dockery WD (2020) Biocomposite interference screws in anterior cruciate ligament reconstruction: osteoconductivity and degradation. Arthrosc Sport Med Rehabil 2:e53\u2013e58. https:\/\/doi.org\/10.1016\/j.asmr.2019.10.001","journal-title":"Arthrosc Sport Med Rehabil"},{"key":"4137_CR4","doi-asserted-by":"publisher","first-page":"2386","DOI":"10.1177\/0363546519861530","volume":"47","author":"S Shumborski","year":"2019","unstructured":"Shumborski S, Heath E, Salmon LJ et al (2019) A randomized controlled trial of PEEK versus titanium interference screws for anterior cruciate ligament reconstruction with 2-year follow-up. Am J Sports Med 47:2386\u20132393. https:\/\/doi.org\/10.1177\/0363546519861530","journal-title":"Am J Sports Med"},{"key":"4137_CR5","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1177\/0363546520911024","volume":"48","author":"K Sundaraj","year":"2020","unstructured":"Sundaraj K, Salmon LJ, Heath EL et al (2020) Bioabsorbable versus titanium screws in anterior cruciate ligament reconstruction using hamstring autograft: a prospective, randomized controlled trial with 13-year follow-up. Am J Sports Med 48:1316\u20131326. https:\/\/doi.org\/10.1177\/0363546520911024","journal-title":"Am J Sports Med"},{"key":"4137_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/2325967120904010","volume":"8","author":"DE Kramer","year":"2020","unstructured":"Kramer DE, Kalish LA, Kocher MS et al (2020) Complications of bioabsorbable tibial interference screws after anterior cruciate ligament reconstruction in pediatric and adolescent athletes. Orthop J Sport Med 8:1\u20138. https:\/\/doi.org\/10.1177\/2325967120904010","journal-title":"Orthop J Sport Med"},{"key":"4137_CR7","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1016\/j.arthro.2018.08.039","volume":"35","author":"ER Chiang","year":"2019","unstructured":"Chiang ER, Chen KH, Chih-Chang Lin A et al (2019) Comparison of tunnel enlargement and clinical outcome between bioabsorbable interference screws and cortical button-post fixation in arthroscopic double-bundle anterior cruciate ligament reconstruction: a prospective, randomized study with a minimum follow up of 2 years. Arthrosc - J Arthrosc Relat Surg 35:544\u2013551. https:\/\/doi.org\/10.1016\/j.arthro.2018.08.039","journal-title":"Arthrosc - J Arthrosc Relat Surg"},{"key":"4137_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-019-2499-y","author":"R Akoto","year":"2019","unstructured":"Akoto R, Albers M, Balke M et al (2019) ACL reconstruction with quadriceps tendon graft and press-fit fixation versus quadruple hamstring graft and interference screw fixation-a matched pair analysis after one year follow up. BMC Musculoskelet Disord. https:\/\/doi.org\/10.1186\/s12891-019-2499-y","journal-title":"BMC Musculoskelet Disord"},{"key":"4137_CR9","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1007\/s00402-020-03508-1","volume":"140","author":"A Bari\u00e9","year":"2020","unstructured":"Bari\u00e9 A, Sprinckstub T, Huber J, Jaber A (2020) Quadriceps tendon vs. patellar tendon autograft for ACL reconstruction using a hardware-free press-fit fixation technique: comparable stability, function and return-to-sport level but less donor site morbidity in athletes after 10 years. Arch Orthop Trauma Surg 140:1465\u20131474. https:\/\/doi.org\/10.1007\/s00402-020-03508-1","journal-title":"Arch Orthop Trauma Surg"},{"key":"4137_CR10","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-021-03862-8","author":"H Horstmann","year":"2021","unstructured":"Horstmann H, Petri M, Tegtbur U et al (2021) Quadriceps and hamstring tendon autografts in ACL reconstruction yield comparably good results in a prospective, randomized controlled trial. Arch Orthop Trauma Surg. https:\/\/doi.org\/10.1007\/s00402-021-03862-8","journal-title":"Arch Orthop Trauma Surg"},{"key":"4137_CR11","doi-asserted-by":"publisher","first-page":"1750","DOI":"10.1007\/s00167-020-06173-4","volume":"29","author":"A Shanmugaraj","year":"2021","unstructured":"Shanmugaraj A, Mahendralingam M, Gohal C et al (2021) Press-fit fixation in anterior cruciate ligament reconstruction yields low graft failure and revision rates: a systematic review and meta-analysis. Knee Surg, Sport Traumatol Arthrosc 29:1750\u20131759. https:\/\/doi.org\/10.1007\/s00167-020-06173-4","journal-title":"Knee Surg, Sport Traumatol Arthrosc"},{"key":"4137_CR12","doi-asserted-by":"publisher","first-page":"e205","DOI":"10.1016\/j.eats.2019.09.024","volume":"9","author":"G Brandl","year":"2020","unstructured":"Brandl G, Ostermann RC, Pauzenberger L et al (2020) Bone-on-bone anatomic patellar tendon graft anterior cruciate ligament reconstruction: a reproducible technique combining press-fit and extracortical fixation. Arthrosc Tech 9:e205\u2013e212. https:\/\/doi.org\/10.1016\/j.eats.2019.09.024","journal-title":"Arthrosc Tech"},{"key":"4137_CR13","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1007\/s00402-006-0206-6","volume":"127","author":"J Dargel","year":"2007","unstructured":"Dargel J, Schmidt-Wiethoff R, Br\u00fcggemann GP, Koebke J (2007) The effect of bone tunnel dilation versus extraction drilling on the initial fixation strength of press-fit anterior cruciate ligament reconstruction. Arch Orthop Trauma Surg 127:801\u2013807. https:\/\/doi.org\/10.1007\/s00402-006-0206-6","journal-title":"Arch Orthop Trauma Surg"},{"key":"4137_CR14","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.jajs.2018.12.002","volume":"6","author":"DRW MacDonald","year":"2019","unstructured":"MacDonald DRW, Bruce E, Stevenson I (2019) A novel technique for bone debris clearance during anterior cruciate ligament reconstruction. J Arthrosc Jt Surg 6:131\u2013132. https:\/\/doi.org\/10.1016\/j.jajs.2018.12.002","journal-title":"J Arthrosc Jt Surg"},{"key":"4137_CR15","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1055\/s-0039-1697625","volume":"34","author":"K Nagira","year":"2021","unstructured":"Nagira K, Enokida M, Hayashi I et al (2021) A simple method to reduce the incidence of cyclops lesion after anterior cruciate ligament reconstruction. J Knee Surg 34:546\u2013551. https:\/\/doi.org\/10.1055\/s-0039-1697625","journal-title":"J Knee Surg"},{"key":"4137_CR16","first-page":"625","volume":"73","author":"E Ugutmen","year":"2007","unstructured":"Ugutmen E, Ozkan K, G\u00fcven M et al (2007) Early tunnel enlargement after arthroscopic ACL reconstructions. Acta Orthop Belg 73:625\u2013629","journal-title":"Acta Orthop Belg"},{"key":"4137_CR17","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.1302\/0301-620X.87B11.16138","volume":"87","author":"AJ Hart","year":"2005","unstructured":"Hart AJ, Buscombe J, Malone A, Dowd GSE (2005) Assessment of osteoarthritis after reconstruction of the anterior cruciate ligament. A study using single-photon emission computed tomography at ten years. J Bone Jt Sur-Ser B 87:1483\u20131487. https:\/\/doi.org\/10.1302\/0301-620X.87B11.16138","journal-title":"J Bone Jt Sur-Ser B"},{"key":"4137_CR18","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1016\/S0749-8063(97)90190-0","volume":"13","author":"DC Wnorowski","year":"1997","unstructured":"Wnorowski DC (1997) The fate of intra-articular debris following arthroscopic anterior cruciate ligament reconstruction. Arthroscopy 13:620\u2013626. https:\/\/doi.org\/10.1016\/S0749-8063(97)90190-0","journal-title":"Arthroscopy"},{"key":"4137_CR19","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1177\/03635465980260061301","volume":"26","author":"R Seil","year":"1998","unstructured":"Seil R, Rupp S, Krauss PW et al (1998) Comparison of initial fixation strength between biodegradable and metallic interference screws and a press-fit fixation technique in a porcine model. Am J Sports Med 26:815\u2013819. https:\/\/doi.org\/10.1177\/03635465980260061301","journal-title":"Am J Sports Med"},{"key":"4137_CR20","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1007\/s00167-005-0645-6","volume":"14","author":"R Schmidt-Wiethoff","year":"2006","unstructured":"Schmidt-Wiethoff R, Dargel J, Gerstner M et al (2006) Bone plug length and loading angle determine the primary stability of patellar tendon-bone grafts in press-fit ACL reconstruction. Knee Surg, Sport Traumatol Arthrosc 14:108\u2013111. https:\/\/doi.org\/10.1007\/s00167-005-0645-6","journal-title":"Knee Surg, Sport Traumatol Arthrosc"},{"key":"4137_CR21","doi-asserted-by":"publisher","first-page":"1772","DOI":"10.1007\/s00198-006-0192-0","volume":"17","author":"R Hamdy","year":"2006","unstructured":"Hamdy R, Kiebzak GM, Seier E, Watts NB (2006) The prevalence of significant left-right differences in hip bone mineral density. Osteoporos Int 17:1772\u20131780. https:\/\/doi.org\/10.1007\/s00198-006-0192-0","journal-title":"Osteoporos Int"},{"key":"4137_CR22","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s00167-003-0351-1","volume":"11","author":"MC Lee","year":"2003","unstructured":"Lee MC, Jo H, Bae TS et al (2003) Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction: a comparative study with titanium and bioabsorbable interference screw using porcine lower limb. Knee Surg, Sport Traumatol Arthrosc 11:91\u201398. https:\/\/doi.org\/10.1007\/s00167-003-0351-1","journal-title":"Knee Surg, Sport Traumatol Arthrosc"},{"key":"4137_CR23","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/S0749-8063(97)90210-3","volume":"13","author":"S Rupp","year":"1997","unstructured":"Rupp S, Krauss PW, Fritsch EW (1997) Fixation strength of a biodegradable interference screw and a press-fit technique in anterior cruciate ligament reconstruction with a BPTB graft. Arthroscopy 13:61\u201365. https:\/\/doi.org\/10.1016\/S0749-8063(97)90210-3","journal-title":"Arthroscopy"},{"key":"4137_CR24","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1016\/j.arthro.2014.11.010","volume":"31","author":"HS Slone","year":"2015","unstructured":"Slone HS, Romine SE, Premkumar A, Xerogeanes JW (2015) Quadriceps tendon autograft for anterior cruciate ligament reconstruction: a comprehensive review of current literature and systematic review of clinical results. Arthrosc-J Arthrosc Relat Surg 31:541\u2013554. https:\/\/doi.org\/10.1016\/j.arthro.2014.11.010","journal-title":"Arthrosc-J Arthrosc Relat Surg"},{"key":"4137_CR25","doi-asserted-by":"publisher","first-page":"208","DOI":"10.2519\/jospt.2012.3768","volume":"42","author":"RF Escamilla","year":"2012","unstructured":"Escamilla RF, MacLeod TD, Wilk KE et al (2012) Anterior cruciate ligament strain and tensile forces for weight-bearing and non-weight-bearing exercises: a guide to exercise selectiona. J Orthop Sports Phys Ther 42:208\u2013220. https:\/\/doi.org\/10.2519\/jospt.2012.3768","journal-title":"J Orthop Sports Phys Ther"},{"key":"4137_CR26","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/S0268-0033(99)00063-7","volume":"15","author":"DE Toutoungi","year":"2000","unstructured":"Toutoungi DE, Lu TW, Leardini A et al (2000) Cruciate ligament forces in the human knee during rehabilitation exercises. Clin Biomech 15:176\u2013187. https:\/\/doi.org\/10.1016\/S0268-0033(99)00063-7","journal-title":"Clin Biomech"},{"key":"4137_CR27","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1016\/j.jbiomech.2006.05.004","volume":"40","author":"CS Shin","year":"2007","unstructured":"Shin CS, Chaudhari AM, Andriacchi TP (2007) The influence of deceleration forces on ACL strain during single-leg landing: a simulation study. J Biomech 40:1145\u20131152. https:\/\/doi.org\/10.1016\/j.jbiomech.2006.05.004","journal-title":"J Biomech"},{"key":"4137_CR28","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s00167-009-0865-2","volume":"18","author":"C Foldager","year":"2010","unstructured":"Foldager C, Jakobsen BW, Lund B et al (2010) Tibial tunnel widening after bioresorbable poly-lactide calcium carbonate interference screw usage in ACL reconstruction. Knee Surg, Sport Traumatol Arthrosc 18:79\u201384. https:\/\/doi.org\/10.1007\/s00167-009-0865-2","journal-title":"Knee Surg, Sport Traumatol Arthrosc"},{"key":"4137_CR29","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1007\/s00402-011-1276-7","volume":"131","author":"S Lenschow","year":"2011","unstructured":"Lenschow S, Herbort M, Str\u00e4sser A et al (2011) Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique. Arch Orthop Trauma Surg 131:1067\u20131072. https:\/\/doi.org\/10.1007\/s00402-011-1276-7","journal-title":"Arch Orthop Trauma Surg"},{"key":"4137_CR30","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1007\/s00167-009-0738-8","volume":"17","author":"ME Hantes","year":"2009","unstructured":"Hantes ME, Zachos VC, Liantsis A et al (2009) Differences in graft orientation using the transtibial and anteromedial portal technique in anterior cruciate ligament reconstruction: a magnetic resonance imaging study. Knee Surg, Sport Traumatol Arthrosc 17:880\u2013886. https:\/\/doi.org\/10.1007\/s00167-009-0738-8","journal-title":"Knee Surg, Sport Traumatol Arthrosc"},{"key":"4137_CR31","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1007\/s00167-009-0829-6","volume":"17","author":"G Basdekis","year":"2009","unstructured":"Basdekis G, Christel P, Anne F (2009) Validation of the position of the femoral tunnels in anatomic double-bundle ACL reconstruction with 3-D CT scan. Knee Surg, Sport Traumatol Arthrosc 17:1089\u20131094. https:\/\/doi.org\/10.1007\/s00167-009-0829-6","journal-title":"Knee Surg, Sport Traumatol Arthrosc"},{"key":"4137_CR32","doi-asserted-by":"publisher","first-page":"1108","DOI":"10.1016\/j.arthro.2009.05.018","volume":"25","author":"G Basdekis","year":"2009","unstructured":"Basdekis G, Abisafi C, Christel P (2009) Effect of knee flexion angle on length and orientation of posterolateral femoral tunnel drilled through anteromedial portal during anatomic double-bundle anterior cruciate ligament reconstruction. Arthrosc-J Arthrosc Relat Surg 25:1108\u20131114. https:\/\/doi.org\/10.1016\/j.arthro.2009.05.018","journal-title":"Arthrosc-J Arthrosc Relat Surg"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-021-04137-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-021-04137-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-021-04137-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T13:07:33Z","timestamp":1658236053000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-021-04137-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,30]]},"references-count":32,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2022,8]]}},"alternative-id":["4137"],"URL":"https:\/\/doi.org\/10.1007\/s00402-021-04137-y","relation":{},"ISSN":["1434-3916"],"issn-type":[{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8,30]]},"assertion":[{"value":"26 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 August 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}