{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T02:34:21Z","timestamp":1776220461903,"version":"3.50.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T00:00:00Z","timestamp":1635724800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"DOI":"10.1007\/s00402-021-04206-2","type":"journal-article","created":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T05:02:41Z","timestamp":1635742961000},"page":"1217-1221","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?"],"prefix":"10.1007","volume":"143","author":[{"given":"Anna","family":"Jungwirth-Weinberger","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carola","family":"Hanreich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian F.","family":"Kasparek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisa","family":"Renner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenzel","family":"Waldstein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7906-9486","authenticated-orcid":false,"given":"Friedrich","family":"Boettner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,11,1]]},"reference":[{"issue":"6","key":"4206_CR1","doi-asserted-by":"publisher","first-page":"578","DOI":"10.3109\/17453679908997845","volume":"70","author":"HL Anissian","year":"1999","unstructured":"Anissian HL, Stark A, Gustafson A, Good V, Clarke IC (1999) Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene. Acta Orthop Scand 70(6):578\u2013582","journal-title":"Acta Orthop Scand"},{"issue":"1","key":"4206_CR2","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.jcot.2019.09.021","volume":"11","author":"JS Chang","year":"2020","unstructured":"Chang JS, Haddad FS (2020) Revision total hip arthroplasty for metal-on-metal failure. J Clin Orthop Trauma 11(1):9\u201315","journal-title":"J Clin Orthop Trauma"},{"issue":"12","key":"4206_CR3","doi-asserted-by":"publisher","first-page":"3542","DOI":"10.1007\/s11999-012-2428-y","volume":"470","author":"R Civinini","year":"2012","unstructured":"Civinini R, Carulli C, Matassi F, Nistri L, Innocenti M (2012) A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions. Clin Orthop Relat Res 470(12):3542\u20133548","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"4206_CR4","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.jos.2015.06.001","volume":"21","author":"J Czekaj","year":"2016","unstructured":"Czekaj J, Ehlinger M, Rahme M, Bonnomet F (2016) Metallosis and cobalt\u2014chrome intoxication after hip resurfacing arthroplasty. J Orthop Sci 21(3):389\u2013394","journal-title":"J Orthop Sci"},{"issue":"8","key":"4206_CR5","doi-asserted-by":"publisher","first-page":"1828","DOI":"10.1016\/j.arth.2016.01.039","volume":"31","author":"MR D'Apuzzo","year":"2016","unstructured":"D\u2019Apuzzo MR, Koch CN, Esposito CI, Elpers ME, Wright TM, Westrich GH (2016) Assessment of damage on a dual mobility acetabular system. J Arthroplast 31(8):1828\u20131835","journal-title":"J Arthroplast"},{"issue":"4 Suppl 1","key":"4206_CR6","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.arth.2006.02.100","volume":"21","author":"KB Fricka","year":"2006","unstructured":"Fricka KB, Marshall A, Paprosky WG (2006) Constrained liners in revision total hip arthroplasty: an overuse syndrome: in the affirmative. J Arthroplast 21(4 Suppl 1):121\u2013125","journal-title":"J Arthroplast"},{"issue":"3","key":"4206_CR7","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1007\/s12012-017-9433-z","volume":"18","author":"ES Fung","year":"2018","unstructured":"Fung ES, Monnot A, Kovochich M et al (2018) Characteristics of cobalt-related cardiomyopathy in metal hip implant patients: an evaluation of 15 published reports. Cardiovasc Toxicol 18(3):206\u2013220","journal-title":"Cardiovasc Toxicol"},{"issue":"10","key":"4206_CR8","doi-asserted-by":"publisher","first-page":"1308","DOI":"10.1302\/0301-620X.93B10.26249","volume":"93","author":"AJ Hart","year":"2011","unstructured":"Hart AJ, Sabah SA, Bandi AS et al (2011) Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Jt Surg Br 93(10):1308\u20131313","journal-title":"J Bone Jt Surg Br"},{"issue":"11","key":"4206_CR9","doi-asserted-by":"publisher","first-page":"3118","DOI":"10.1007\/s11999-012-2329-0","volume":"470","author":"A Hartmann","year":"2012","unstructured":"Hartmann A, Lutzner J, Kirschner S, Witzleb WC, Gunther KP (2012) Do survival rate and serum ion concentrations 10 years after metal-on-metal hip resurfacing provide evidence for continued use? Clin Orthop Relat Res 470(11):3118\u20133126","journal-title":"Clin Orthop Relat Res"},{"issue":"8 Suppl 3","key":"4206_CR10","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1016\/j.arth.2004.09.011","volume":"19","author":"OL Huk","year":"2004","unstructured":"Huk OL, Catelas I, Mwale F, Antoniou J, Zukor DJ, Petit A (2004) Induction of apoptosis and necrosis by metal ions in vitro. J Arthroplast 19(8 Suppl 3):84\u201387","journal-title":"J Arthroplast"},{"issue":"2","key":"4206_CR11","doi-asserted-by":"publisher","first-page":"69","DOI":"10.5435\/00124635-200902000-00003","volume":"17","author":"JJ Jacobs","year":"2009","unstructured":"Jacobs JJ, Urban RM, Hallab NJ, Skipor AK, Fischer A, Wimmer MA (2009) Metal-on-metal bearing surfaces. J Am Acad Orthop Surg 17(2):69\u201376","journal-title":"J Am Acad Orthop Surg"},{"key":"4206_CR12","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1186\/s13018-014-0091-6","volume":"9","author":"A Kanaji","year":"2014","unstructured":"Kanaji A, Orhue V, Caicedo MS et al (2014) Cytotoxic effects of cobalt and nickel ions on osteocytes in vitro. J Orthop Surg Res 9:91","journal-title":"J Orthop Surg Res"},{"issue":"5","key":"4206_CR13","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1007\/s00264-017-3641-9","volume":"42","author":"MF Kasparek","year":"2018","unstructured":"Kasparek MF, Renner L, Faschingbauer M, Waldstein W, Rueckl K, Boettner F (2018) Salvage of a monoblock metal-on-metal cup using a dual mobility liner: a two-year MRI follow-up study. Int Orthop 42(5):1035\u20131041","journal-title":"Int Orthop"},{"issue":"2","key":"4206_CR14","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/s00402-017-2856-y","volume":"138","author":"MF Kasparek","year":"2018","unstructured":"Kasparek MF, Renner L, Faschingbauer M, Waldstein W, Weber M, Boettner F (2018) Predictive factors for metal ion levels in metal-on-metal total hip arthroplasty. Arch Orthop Trauma Surg 138(2):281\u2013286","journal-title":"Arch Orthop Trauma Surg"},{"issue":"3","key":"4206_CR15","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1016\/j.arth.2018.11.023","volume":"34","author":"CH Kim","year":"2019","unstructured":"Kim CH, Ryu JJ, Jeong MY, Kim JW, Chang JS, Yoon PW (2019) Serum metal ion levels in cementless metal-on-metal total hip arthroplasty: long-term follow-up trends. J Arthroplast 34(3):534\u2013537","journal-title":"J Arthroplast"},{"key":"4206_CR16","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-021-03891-3","author":"C Klemt","year":"2021","unstructured":"Klemt C, Limmahakhun S, Bounajem G, Melnic CM, Harvey MJ, Kwon YM (2021) Outcome of revision surgery for adverse local tissue reactions in patients with recalled total hip arthroplasty. Arch Orthop Trauma Surg. https:\/\/doi.org\/10.1007\/s00402-021-03891-3","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"4206_CR17","doi-asserted-by":"publisher","first-page":"e4","DOI":"10.2106\/JBJS.M.00160","volume":"96","author":"YM Kwon","year":"2014","unstructured":"Kwon YM, Lombardi AV, Jacobs JJ, Fehring TK, Lewis CG, Cabanela ME (2014) Risk stratification algorithm for management of patients with metal-on-metal hip arthroplasty: consensus statement of the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and the Hip Society. J Bone Jt Surg Am 96(1):e4","journal-title":"J Bone Jt Surg Am"},{"issue":"9","key":"4206_CR18","doi-asserted-by":"publisher","first-page":"3025","DOI":"10.1016\/j.arth.2018.04.007","volume":"33","author":"YM Kwon","year":"2018","unstructured":"Kwon YM, MacAuliffe J, Arauz PG, Peng Y (2018) Sensitivity and specificity of metal ion level in predicting adverse local tissue reactions due to head-neck taper corrosion in primary metal-on-polyethylene total hip arthroplasty. J Arthroplast 33(9):3025\u20133029","journal-title":"J Arthroplast"},{"issue":"8 Suppl 3","key":"4206_CR19","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.arth.2004.09.010","volume":"19","author":"D Ladon","year":"2004","unstructured":"Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP (2004) Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplast 19(8 Suppl 3):78\u201383","journal-title":"J Arthroplast"},{"issue":"2","key":"4206_CR20","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1007\/s11999-014-3976-0","volume":"473","author":"AV Lombardi Jr","year":"2015","unstructured":"Lombardi AV Jr, Berend KR, Morris MJ, Adams JB, Sneller MA (2015) Large-diameter metal-on-metal total hip arthroplasty: dislocation infrequent but survivorship poor. Clin Orthop Relat Res 473(2):509\u2013520","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"4206_CR21","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1016\/j.arth.2015.08.016","volume":"31","author":"DR Plummer","year":"2016","unstructured":"Plummer DR, Botero HG, Berend KR, Pritchett JW, Lombardi AV, Della Valle CJ (2016) Salvage of monoblock metal-on-metal acetabular components using a dual-mobility bearing. J Arthroplast 31(4):846\u2013849","journal-title":"J Arthroplast"},{"issue":"11","key":"4206_CR22","doi-asserted-by":"publisher","first-page":"2559","DOI":"10.1016\/j.arth.2016.04.033","volume":"31","author":"WA Rahman","year":"2016","unstructured":"Rahman WA, Amenabar T, Hetaimish BM, Safir OA, Kuzyk PR, Gross AE (2016) Outcome of revision total hip arthroplasty in management of failed metal-on-metal hip arthroplasty. J Arthroplast 31(11):2559\u20132563","journal-title":"J Arthroplast"},{"issue":"5","key":"4206_CR23","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1007\/s00402-016-2439-3","volume":"136","author":"L Renner","year":"2016","unstructured":"Renner L, Faschingbauer M, Schmidt-Braekling T, Boettner F (2016) Cobalt serum levels differ in well functioning Birmingham resurfacing and Birmingham modular THA. Arch Orthop Trauma Surg 136(5):715\u2013721","journal-title":"Arch Orthop Trauma Surg"},{"issue":"12","key":"4206_CR24","doi-asserted-by":"publisher","first-page":"1657","DOI":"10.1007\/s00402-016-2565-y","volume":"136","author":"L Renner","year":"2016","unstructured":"Renner L, Schmidt-Braekling T, Faschingbauer M, Boettner F (2016) Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty? Arch Orthop Trauma Surg 136(12):1657\u20131662","journal-title":"Arch Orthop Trauma Surg"},{"issue":"9668","key":"4206_CR25","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1016\/S0140-6736(09)60490-6","volume":"373","author":"MC Rizzetti","year":"2009","unstructured":"Rizzetti MC, Liberini P, Zarattini G et al (2009) Loss of sight and sound. Could it be the hip? Lancet 373(9668):1052","journal-title":"Lancet"},{"issue":"4","key":"4206_CR26","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1016\/j.arth.2014.10.034","volume":"30","author":"J Wegrzyn","year":"2015","unstructured":"Wegrzyn J, Tebaa E, Jacquel A, Carret JP, Bejui-Hugues J, Pibarot V (2015) Can dual mobility cups prevent dislocation in all situations after revision total hip arthroplasty? J Arthroplast 30(4):631\u2013640","journal-title":"J Arthroplast"},{"issue":"7","key":"4206_CR27","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1016\/j.arth.2013.03.027","volume":"28","author":"KF Wiley","year":"2013","unstructured":"Wiley KF, Ding K, Stoner JA, Teague DC, Yousuf KM (2013) Incidence of pseudotumor and acute lymphocytic vasculitis associated lesion (ALVAL) reactions in metal-on-metal hip articulations: a meta-analysis. J Arthroplast 28(7):1238\u20131245","journal-title":"J Arthroplast"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-021-04206-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-021-04206-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-021-04206-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,24]],"date-time":"2023-02-24T16:07:03Z","timestamp":1677254823000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-021-04206-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,1]]},"references-count":27,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2023,3]]}},"alternative-id":["4206"],"URL":"https:\/\/doi.org\/10.1007\/s00402-021-04206-2","relation":{},"ISSN":["1434-3916"],"issn-type":[{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,1]]},"assertion":[{"value":"23 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 November 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"FB receives royalties from Orthodevelopment\u00a0Inc. and Smith and Nephew and compensation from Orthodevelopment\u00a0Inc., Smith and Nephew, JNJ\u00a0Depuy and Medtronic, unrelated to this research.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was approved by the institutional review board.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}