{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T12:36:10Z","timestamp":1740141370194,"version":"3.37.3"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,2,14]],"date-time":"2024-02-14T00:00:00Z","timestamp":1707868800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,14]],"date-time":"2024-02-14T00:00:00Z","timestamp":1707868800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100006034","name":"University of Southern California","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100006034","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Introduction<\/jats:title>\n                <jats:p>The use of magnetic resonance imaging (MRI) with a magnetic intramedullary lengthening nail in place is contraindicated per the manufacturer due to the concern of implant activation and migration. A prior in vitro study did not confirm these complications only noting that a 3.0\u00a0T MRI weakened the internal magnet. Therefore, a retrospective analysis of patients who underwent an MRI with a magnetic nail in place was performed to determine if any adverse effects occurred in the clinical setting.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>A retrospective review of all patients who underwent an MRI with a magnetic lengthening nail in place was performed. The time spent being imaged in the MRI, number of times the patient entered the MRI suite, and the images obtained were recorded. Radiographs were performed before and after the MRI to determine if any hardware complications occurred. The patients were monitored for any adverse symptoms while they were in the suite.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A total of 12 patients with 13 nails were identified. Two patients underwent imaging with a 3.0\u00a0T MRI while the remaining 10 underwent imaging with a 1.5\u00a0T MRI. Each patient entered the MRI suite 2.1 times and spent an average of 84.7\u00a0min being imaged in the MRI (range 21\u2013494). No patients noted any adverse symptoms related to the nail while in the suite and no hardware complications were identified.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>MRI appears to be safe with a magnetic nail in place and did not result in any complications. Given the manufacturer\u2019s recommendations, informed consent should be obtained prior to an MRI being performed and a 3.0\u00a0T MRI should be avoided when possible if further activation of the nail is required.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00402-024-05210-y","type":"journal-article","created":{"date-parts":[[2024,2,14]],"date-time":"2024-02-14T09:02:21Z","timestamp":1707901341000},"page":"1503-1509","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Clinical compatibility of magnetic resonance imaging with magnetic intramedullary nails: a feasibility study"],"prefix":"10.1007","volume":"144","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6664-5678","authenticated-orcid":false,"given":"Joseph D.","family":"Femino","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1065-8442","authenticated-orcid":false,"given":"Samuel R.","family":"Barnes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0122-9304","authenticated-orcid":false,"given":"Scott C.","family":"Nelson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7762-2906","authenticated-orcid":false,"given":"Lee M.","family":"Zuckerman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,2,14]]},"reference":[{"issue":"2","key":"5210_CR1","doi-asserted-by":"publisher","first-page":"110","DOI":"10.5005\/jp-journals-10080-1529","volume":"16","author":"MW Frost","year":"2021","unstructured":"Frost MW, Kold S, Rahbek O, Bafor A, Duncan M, Iobst CA (2021) Complications in elective removal of 271 Bone Lengthening Nails (FITBONE, PRECICE and STRYDE). Strategies Trauma Limb Reconstr 16(2):110\u2013115. https:\/\/doi.org\/10.5005\/jp-journals-10080-1529","journal-title":"Strategies Trauma Limb Reconstr"},{"issue":"11","key":"5210_CR2","doi-asserted-by":"publisher","first-page":"1731","DOI":"10.1302\/0301-620X.103B.BJJ-2021-0549.R1","volume":"103-B","author":"CA Iobst","year":"2021","unstructured":"Iobst CA, Frost MW, R\u00f6lfing JD, Rahbek O, Bafor A, Duncan M, Kold S (2021) Radiographs of 366 removed limb-lengthening nails reveal differences in bone abnormalities between different nail types. Bone Joint J 103-B(11):1731\u20131735. https:\/\/doi.org\/10.1302\/0301-620X.103B.BJJ-2021-0549.R1","journal-title":"Bone Joint J"},{"issue":"2","key":"5210_CR3","doi-asserted-by":"publisher","first-page":"e192","DOI":"10.1097\/BPO.0000000000002016","volume":"42","author":"C Radler","year":"2022","unstructured":"Radler C, Mindler GT, Stauffer A, Wei\u00df C, Ganger R (2022) Limb lengthening with Precice intramedullary lengthening nails in children and adolescents. J Pediatr Orthop 42(2):e192\u2013e200. https:\/\/doi.org\/10.1097\/BPO.0000000000002016","journal-title":"J Pediatr Orthop"},{"issue":"3","key":"5210_CR4","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1586\/17434440.2015.1005604","volume":"12","author":"D Paley","year":"2015","unstructured":"Paley D (2015) PRECICE intramedullary limb lengthening system. Expert Rev Med Devices 12(3):231\u2013249. https:\/\/doi.org\/10.1586\/17434440.2015.1005604","journal-title":"Expert Rev Med Devices"},{"issue":"3","key":"5210_CR5","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1080\/17434440.2022.2054336","volume":"19","author":"LM Zuckerman","year":"2022","unstructured":"Zuckerman LM, Scolaro JA, Gardner MP, Kern T, Lanz P, Quinnan SM, Watson JT, R\u00f6lfing JD (2022) Technical considerations for the management of segmental osseous defects with an internal bone transport nail. Expert Rev Med Devices 19(3):203\u2013211. https:\/\/doi.org\/10.1080\/17434440.2022.2054336","journal-title":"Expert Rev Med Devices"},{"key":"5210_CR6","unstructured":"NuVasive Specialized Orthopedics, Inc (2021) PRECICE intramedullary limb lengthening systems instructions for use. https:\/\/atlasapi.nuvasive.com\/public\/ifu\/documents\/retrieve?get&pVersion=0046&contRep=ZNUVEP1&docId=005056860AAC1EDC91CC6F532B9FA13D&compId=LC0305_C_MASTER.pdf. Accessed 11 Jan 2023"},{"issue":"4","key":"5210_CR7","doi-asserted-by":"publisher","first-page":"E14","DOI":"10.3171\/2017.7.FOCUS17356","volume":"43","author":"AC Vivas","year":"2017","unstructured":"Vivas AC, Hwang SW, Pahys JM (2017) Insertion of magnetically controlled growing rods in a patient with a diaphragmatic pacemaker: case report. Neurosurg Focus 43(4):E14. https:\/\/doi.org\/10.3171\/2017.7.FOCUS17356","journal-title":"Neurosurg Focus"},{"issue":"2","key":"5210_CR8","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1007\/s00586-015-4178-5","volume":"25","author":"HR Budd","year":"2016","unstructured":"Budd HR, Stokes OM, Meakin J, Fulford J, Hutton M (2016) Safety and compatibility of magnetic-controlled growing rods and magnetic resonance imaging. Eur Spine J 25(2):578\u2013582. https:\/\/doi.org\/10.1007\/s00586-015-4178-5","journal-title":"Eur Spine J"},{"issue":"3","key":"5210_CR9","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1016\/j.jspd.2017.10.004","volume":"6","author":"RP Woon","year":"2018","unstructured":"Woon RP, Andras LM, Noordeen H, Morris S, Hutchinson J, Shah SA, Pawelek J, Johnston CE, Skaggs DL, Children\u2019s Spine Study Group; Growing Spine Study Group (2018) Surgeon survey shows no adverse events with MRI in patients with magnetically controlled growing rods (MCGRs). Spine Deform 6(3):299\u2013302. https:\/\/doi.org\/10.1016\/j.jspd.2017.10.004","journal-title":"Spine Deform"},{"issue":"3","key":"5210_CR10","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.jspd.2017.11.003","volume":"6","author":"S Poon","year":"2018","unstructured":"Poon S, Chen YH, Wendolowski SF, Graver A, Nixon R, Amaral T, DiMauro JP, Walz DM, Gecelter RC, Grande DA (2018) Cadaveric study of the safety and device functionality of magnetically controlled growing rods after exposure to magnetic resonance imaging. Spine Deform 6(3):290\u2013298. https:\/\/doi.org\/10.1016\/j.jspd.2017.11.003","journal-title":"Spine Deform"},{"issue":"9","key":"5210_CR11","doi-asserted-by":"publisher","first-page":"E504","DOI":"10.1097\/BRS.0000000000001880","volume":"42","author":"M Eroglu","year":"2017","unstructured":"Eroglu M, Demirkiran G, Kocyigit IA, Bilgili H, Kaynar MB, Bumin A, Ozcan S, Yazici M (2017) Magnetic resonance imaging safety of magnetically controlled growing rods in an in vivo animal model. Spine (Phila Pa 1976) 42(9):E504\u2013E508. https:\/\/doi.org\/10.1097\/BRS.0000000000001880","journal-title":"Spine (Phila Pa 1976)"},{"issue":"10","key":"5210_CR12","doi-asserted-by":"publisher","first-page":"e584","DOI":"10.1097\/BPO.0000000000001236","volume":"38","author":"C Gomez","year":"2018","unstructured":"Gomez C, Nelson S, Speirs J, Barnes S (2018) Magnetic intramedullary lengthening nails and MRI compatibility. J Pediatr Orthop 38(10):e584\u2013e587. https:\/\/doi.org\/10.1097\/BPO.0000000000001236","journal-title":"J Pediatr Orthop"},{"issue":"5","key":"5210_CR13","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1097\/00006416-200609000-00005","volume":"25","author":"M Patterson","year":"2006","unstructured":"Patterson M (2006) Impact of external fixation on adolescents: an integrative research review. Orthop Nurs 25(5):300\u2013308. https:\/\/doi.org\/10.1097\/00006416-200609000-00005","journal-title":"Orthop Nurs"},{"issue":"45","key":"5210_CR14","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000008569","volume":"96","author":"H Wang","year":"2017","unstructured":"Wang H, Wei X, Liu P, Fu YH, Wang PF, Cong YX, Zhang BF, Li Z, Lei JL, Zhang K, Zhuang Y (2017) Quality of life and complications at the different stages of bone transport for treatment infected nonunion of the tibia. Medicine (Baltimore) 96(45):e8569. https:\/\/doi.org\/10.1097\/MD.0000000000008569","journal-title":"Medicine (Baltimore)"},{"issue":"6","key":"5210_CR15","doi-asserted-by":"publisher","first-page":"1367","DOI":"10.1007\/s00264-022-05399-w","volume":"46","author":"M Hafez","year":"2022","unstructured":"Hafez M, Nicolaou N, Offiah A, Offorha B, Giles S, Madan S, Fernandes JA (2022) Quality of life of children during distraction osteogenesis: a comparison between intramedullary magnetic lengthening nails and external fixators. Int Orthop 46(6):1367\u20131373. https:\/\/doi.org\/10.1007\/s00264-022-05399-w","journal-title":"Int Orthop"},{"issue":"Suppl 3","key":"5210_CR16","doi-asserted-by":"publisher","first-page":"S81","DOI":"10.1016\/j.injury.2022.06.028","volume":"53","author":"PR Calder","year":"2022","unstructured":"Calder PR, Wright J, Goodier WD (2022) An update on the intramedullary implant in limb lengthening: a quinquennial review part 1: the further influence of the intramedullary nail in limb lengthening. Injury 53(Suppl 3):S81\u2013S87. https:\/\/doi.org\/10.1016\/j.injury.2022.06.028","journal-title":"Injury"},{"issue":"1","key":"5210_CR17","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1007\/s00776-014-0659-3","volume":"20","author":"M K\u00fc\u00e7\u00fckkaya","year":"2015","unstructured":"K\u00fc\u00e7\u00fckkaya M, Karakoyun \u00d6, S\u00f6k\u00fcc\u00fc S, Soydan R (2015) Femoral lengthening and deformity correction using the Fitbone motorized lengthening nail. J Orthop Sci 20(1):149\u2013154. https:\/\/doi.org\/10.1007\/s00776-014-0659-3","journal-title":"J Orthop Sci"},{"issue":"2","key":"5210_CR18","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.otsr.2015.10.011","volume":"102","author":"F Accadbled","year":"2016","unstructured":"Accadbled F, Pailh\u00e9 R, Cavaignac E, Sales de Gauzy J (2016) Bone lengthening using the Fitbone(\u00ae) motorized intramedullary nail: the first experience in France. Orthop Traumatol Surg Res 102(2):217\u2013222. https:\/\/doi.org\/10.1016\/j.otsr.2015.10.011","journal-title":"Orthop Traumatol Surg Res"},{"issue":"6","key":"5210_CR19","doi-asserted-by":"publisher","first-page":"330","DOI":"10.3928\/01477447-20181102-02","volume":"41","author":"RC Vercio","year":"2018","unstructured":"Vercio RC, Shields TG, Zuckerman LM (2018) Use of magnetic growing intramedullary nails in compression during intercalary allograft reconstruction. Orthopedics 41(6):330\u2013335. https:\/\/doi.org\/10.3928\/01477447-20181102-02","journal-title":"Orthopedics"},{"issue":"3","key":"5210_CR20","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/j.jseint.2021.11.022","volume":"6","author":"DJ Cognetti","year":"2022","unstructured":"Cognetti DJ, Ghali A, Gutierrez-Naranjo JM, Handcox J, Karia R, Dutta AK (2022) Technical considerations and early results of magnetic compressive intramedullary nailing for humeral shaft delayed unions and nonunions. JSES Int 6(3):385\u2013390. https:\/\/doi.org\/10.1016\/j.jseint.2021.11.022","journal-title":"JSES Int"},{"key":"5210_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2021.105508","volume":"90","author":"A Mierke","year":"2021","unstructured":"Mierke A, Shields TG, Williams NL, Zuckerman LM (2021) Comparison of forces generated using compression plating versus a magnetic lengthening nail in a sawbones femur model. Clin Biomech (Bristol, Avon) 90:105508. https:\/\/doi.org\/10.1016\/j.clinbiomech.2021.105508","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"11","key":"5210_CR22","doi-asserted-by":"publisher","first-page":"1551","DOI":"10.1007\/s00402-019-03225-4","volume":"139","author":"AT Fragomen","year":"2019","unstructured":"Fragomen AT, Wellman D, Rozbruch SR (2019) The PRECICE magnetic IM compression nail for long bone nonunions: a preliminary report. Arch Orthop Trauma Surg 139(11):1551\u20131560. https:\/\/doi.org\/10.1007\/s00402-019-03225-4","journal-title":"Arch Orthop Trauma Surg"},{"issue":"8","key":"5210_CR23","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOSGlobal-D-19-00064","volume":"3","author":"UK Olesen","year":"2019","unstructured":"Olesen UK, Nygaard T, Prince DE, Gardner MP, Singh UM, McNally MA, Green CJ, Herzenberg JE (2019) Plate-assisted bone segment transport with motorized lengthening nails and locking plates: a technique to treat femoral and tibial bone defects. J Am Acad Orthop Surg Glob Res Rev 3(8):e064. https:\/\/doi.org\/10.5435\/JAAOSGlobal-D-19-00064","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"issue":"Suppl 4","key":"5210_CR24","doi-asserted-by":"publisher","first-page":"S19","DOI":"10.1097\/BOT.0000000000002123","volume":"35","author":"MP Gardner","year":"2021","unstructured":"Gardner MP, Beason AM (2021) Plate-assisted bone segment transport versus precice bone transport nail. J Orthop Trauma 35(Suppl 4):S19\u2013S24. https:\/\/doi.org\/10.1097\/BOT.0000000000002123","journal-title":"J Orthop Trauma"},{"issue":"Suppl 4","key":"5210_CR25","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1097\/BOT.0000000000002118","volume":"35","author":"LM Zuckerman","year":"2021","unstructured":"Zuckerman LM (2021) Biologic reconstruction with a motorized intramedullary bone transport nail after tumor resection. J Orthop Trauma 35(Suppl 4):S25\u2013S30. https:\/\/doi.org\/10.1097\/BOT.0000000000002118","journal-title":"J Orthop Trauma"},{"issue":"12","key":"5210_CR26","doi-asserted-by":"publisher","first-page":"3869","DOI":"10.1007\/s11999-014-3575-0","volume":"472","author":"YM Kirane","year":"2014","unstructured":"Kirane YM, Fragomen AT, Rozbruch SR (2014) Precision of the PRECICE internal bone lengthening nail. Clin Orthop Relat Res 472(12):3869\u20133878. https:\/\/doi.org\/10.1007\/s11999-014-3575-0","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"5210_CR27","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1007\/s11420-017-9596-y","volume":"14","author":"AT Fragomen","year":"2018","unstructured":"Fragomen AT, Kurtz AM, Barclay JR, Nguyen J, Rozbruch SR (2018) A comparison of femoral lengthening methods favors the magnetic internal lengthening nail when compared with lengthening over a nail. HSS J 14(2):166\u2013176. https:\/\/doi.org\/10.1007\/s11420-017-9596-y","journal-title":"HSS J"},{"issue":"17","key":"5210_CR28","doi-asserted-by":"publisher","first-page":"e767","DOI":"10.5435\/JAAOS-D-18-00038","volume":"27","author":"BC Taylor","year":"2019","unstructured":"Taylor BC, Triplet JJ, El-Sabawi T (2019) Off-label use in orthopaedic surgery. J Am Acad Orthop Surg 27(17):e767\u2013e774. https:\/\/doi.org\/10.5435\/JAAOS-D-18-00038","journal-title":"J Am Acad Orthop Surg"},{"issue":"1","key":"5210_CR29","first-page":"53","volume":"49","author":"SA Syed","year":"2021","unstructured":"Syed SA, Dixson BA, Constantino E, Regan J (2021) The law and practice of off-label prescribing and physician promotion. J Am Acad Psychiatry Law 49(1):53\u201359","journal-title":"J Am Acad Psychiatry Law"},{"issue":"11","key":"5210_CR30","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1302\/2058-5241.6.210080","volume":"6","author":"K Tucker","year":"2021","unstructured":"Tucker K, G\u00fcnther KP, Kjaersgaard-Andersen P, L\u00fctzner J, Kretzer JP, Nelissen RGHH, Lange T, Zagra L (2021) EFFORT recommendations for off-label use, mix & match and mismatch in hip and knee arthroplasty. EFFORT Open Rev 6(11):982\u20131005. https:\/\/doi.org\/10.1302\/2058-5241.6.210080","journal-title":"EFFORT Open Rev"},{"issue":"7","key":"5210_CR31","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.1016\/j.spinee.2022.02.005","volume":"22","author":"DS Weinberg","year":"2022","unstructured":"Weinberg DS, Eoh JH, Manz WJ, Fakunle OP, Dawes AM, Park ET, Rhee JM (2022) Off-label usage of RhBMP-2 in posterior cervical fusion is not associated with early increased complication rate and has similar clinical outcomes. Spine J 22(7):1079\u20131088. https:\/\/doi.org\/10.1016\/j.spinee.2022.02.005","journal-title":"Spine J"},{"issue":"12","key":"5210_CR32","doi-asserted-by":"publisher","first-page":"2601","DOI":"10.1007\/s00264-014-2534-4","volume":"38","author":"A Courvoisier","year":"2014","unstructured":"Courvoisier A, Sailhan F, Laffen\u00eatre O, Obert L, French Study Group of BMP in Orthopedic Surgery (2014) Bone morphogenetic protein and orthopaedic surgery: can we legitimate its off-label use? Int Orthop 38(12):2601\u20132605. https:\/\/doi.org\/10.1007\/s00264-014-2534-4","journal-title":"Int Orthop"},{"issue":"11","key":"5210_CR33","doi-asserted-by":"publisher","first-page":"1872","DOI":"10.1016\/j.arth.2015.05.020","volume":"30","author":"T Malcolm","year":"2015","unstructured":"Malcolm T, Szubski CR, Schiltz NK, Klika AK, Koroukian SM, Barsoum WK (2015) Prevalence and perioperative outcomes of off-label total hip and knee arthroplasty in the United States, 2000\u20132010. J Arthroplasty 30(11):1872\u20131878. https:\/\/doi.org\/10.1016\/j.arth.2015.05.020","journal-title":"J Arthroplasty"},{"issue":"15","key":"5210_CR34","doi-asserted-by":"publisher","first-page":"3625","DOI":"10.2147\/JPR.S357416","volume":"22","author":"T Ragukonis","year":"2022","unstructured":"Ragukonis T (2022) Off-label magnetic resonance imaging (MRI) in patients with persistent pain with spinal cord stimulators: a case series. J Pain Res 22(15):3625\u20133638. https:\/\/doi.org\/10.2147\/JPR.S357416","journal-title":"J Pain Res"},{"issue":"4","key":"5210_CR35","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1159\/000503730","volume":"97","author":"J Manfield","year":"2019","unstructured":"Manfield J, Bartlett R, Park N (2019) Safety and utility of spinal magnetic resonance imaging in patients with high-frequency spinal cord stimulators: a prospective single-centre study. Stereotact Funct Neurosurg 97(4):272\u2013277. https:\/\/doi.org\/10.1159\/000503730","journal-title":"Stereotact Funct Neurosurg"},{"issue":"3","key":"5210_CR36","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.M.00288","volume":"96","author":"ED Sheha","year":"2014","unstructured":"Sheha ED, Hammouri Q, Snyder BD, Campbell RM Jr, Vitale MG, POSNA, SRS Task Force for Pediatric Medical Devices (2014) Off-label use of pediatric orthopaedic devices: important issues for the future. J Bone Joint Surg Am 96(3):e21. https:\/\/doi.org\/10.2106\/JBJS.M.00288","journal-title":"J Bone Joint Surg Am"},{"key":"5210_CR37","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/00003086-200009000-00006","volume":"378","author":"MR Zindrick","year":"2000","unstructured":"Zindrick MR (2000) Orthopaedic surgery and food and drug administration off-label uses. Clin Orthop Relat Res 378:31\u201338. https:\/\/doi.org\/10.1097\/00003086-200009000-00006","journal-title":"Clin Orthop Relat Res"},{"key":"5210_CR38","unstructured":"NuVasive Specialized Orthopedics, Inc (2022) MAGEC spinal bracing and distraction system instructions for use. https:\/\/atlasapi.nuvasive.com\/public\/ifu\/documents\/retrieve?get&pVersion=0046&contRep=ZNUVEP1&docId=0050568619A61EDD81F6F5930C4DE14A&compId=LC0063_V_MASTER.pdf. Accessed 22 Mar 2023"},{"issue":"1","key":"5210_CR39","doi-asserted-by":"publisher","first-page":"e44","DOI":"10.1097\/BPO.0000000000001672","volume":"41","author":"AD Iliadis","year":"2021","unstructured":"Iliadis AD, Palloni V, Wright J, Goodier D, Calder P (2021) Pediatric lower limb lengthening using the PRECICE nail: our experience with 50 cases. J Pediatr Orthop 41(1):e44\u2013e49. https:\/\/doi.org\/10.1097\/BPO.0000000000001672","journal-title":"J Pediatr Orthop"},{"issue":"6","key":"5210_CR40","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1097\/BPB.0000000000000651","volume":"29","author":"LA Nasto","year":"2020","unstructured":"Nasto LA, Coppa V, Riganti S, Ruzzini L, Manfrini M, Campanacci L, Palmacci O, Boero S (2020) Clinical results and complication rates of lower limb lengthening in paediatric patients using the PRECICE 2 intramedullary magnetic nail: a multicentre study. J Pediatr Orthop B 29(6):611\u2013617. https:\/\/doi.org\/10.1097\/BPB.0000000000000651","journal-title":"J Pediatr Orthop B"},{"key":"5210_CR41","unstructured":"NuVasive Specialized Orthopedics, Inc (2023) NuVasive specialized orthopedics expands indications of precice limb lengthening system to treat pediatric patients. https:\/\/www.prnewswire.com\/news-releases\/nuvasive-specialized-orthopedics-expands-indications-of-precice-limb-lengthening-system-to-treat-pediatric-patients-301775389.html. Accessed 22 Mar 2023"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-024-05210-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-024-05210-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-024-05210-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,26]],"date-time":"2024-03-26T15:18:18Z","timestamp":1711466298000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-024-05210-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,14]]},"references-count":41,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["5210"],"URL":"https:\/\/doi.org\/10.1007\/s00402-024-05210-y","relation":{},"ISSN":["1434-3916"],"issn-type":[{"type":"electronic","value":"1434-3916"}],"subject":[],"published":{"date-parts":[[2024,2,14]]},"assertion":[{"value":"22 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Financial interests: Dr. Femino has stock in Stryker Corp. and Intuitive Surgical, Inc. Dr. Barnes declares he has no financial interests. Dr. Nelson has received speaker and consultant honoraria from DePuy Synthes and Orthofix, Inc. Dr. Zuckerman has received speaker and consultant honoraria from NuVasive Specialized Orthopedics, Inc. and research funding from Onkos Surgical, Inc.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Institutional Review Board of Loma Linda University (20 December 2022, IRB #5210002).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The requirement for informed consent was waived by our Institutional Review Board.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}]}}