{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T02:42:25Z","timestamp":1768272145704,"version":"3.49.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2024,7,15]],"date-time":"2024-07-15T00:00:00Z","timestamp":1721001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,15]],"date-time":"2024-07-15T00:00:00Z","timestamp":1721001600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100006390","name":"University of Lausanne","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100006390","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>To characterize the intra- and inter-operator reliability of a CT-based 3D preoperative planning software.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>This study analyzed 30 CT scans of de-identified knees with osteoarthritis. For each scan, a case planner segmented the bones and pre-planned the TKA. Three orthopedic surgeons then reviewed each pre-planning three times at least one week apart, in a blinded manner. During the reviews, the surgeons modified the pre-plannings until they felt the plannings matched the objectives defined collegially at the beginning of the study. Reliability was assessed using the Intraclass Correlation Coefficient (ICC) and the Standard Error of Measurement (SEM).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The intra- and inter-operator reliabilities for implant size selection were almost perfect (ICC between 0.97 and 0.99). Implants of same sizes were selected in 67.1\u201390.0% of cases. For implant placements, almost perfect intra- and inter-operator reliability was observed in all degrees-of-freedom (ICC between 0.81 and 1.00), except in flexion-extension for the femur (intra-operator ICC between: 0.76 and 0.99; inter-operator ICC of 0.61) and the tibia (intra-operator ICC between 0.12 and 1.00; inter-operator ICC of 0.03). All implant placements SEM were below 1.3\u00a0mm or 1.7\u00b0.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>This study showed high intra- and inter-operator reliability for implant size selection and, in most of the degrees-of-freedom, also for implant placements. Further research is needed to evaluate the benefit of developing more precise means of describing the objectives of the surgical planning as well as to evaluate the possibility and relevance of adding features in the planning software to assist the operators.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00402-024-05438-8","type":"journal-article","created":{"date-parts":[[2024,7,15]],"date-time":"2024-07-15T04:01:39Z","timestamp":1721016099000},"page":"3625-3630","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Intra- and inter-operator reliability of three-dimensional preoperative planning in total knee arthroplasty"],"prefix":"10.1007","volume":"144","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3997-1616","authenticated-orcid":false,"given":"Killian","family":"Cosendey","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kevin","family":"Moerenhout","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julien","family":"Stanovici","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brigitte M.","family":"Jolles","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julien","family":"Favre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,7,15]]},"reference":[{"key":"5438_CR1","doi-asserted-by":"publisher","first-page":"1455","DOI":"10.2106\/JBJS.17.01617","volume":"100","author":"M Sloan","year":"2018","unstructured":"Sloan M, Premkumar A, Sheth NP (2018) Projected Volume of Primary Total Joint Arthroplasty in the U.S., 2014 to 2030. J Bone Joint Surg Am 100:1455\u20131460. https:\/\/doi.org\/10.2106\/JBJS.17.01617","journal-title":"J Bone Joint Surg Am"},{"key":"5438_CR2","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/s11999-009-1119-9","volume":"468","author":"RB Bourne","year":"2010","unstructured":"Bourne RB, Chesworth BM, Davis AM et al (2010) Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res 468:57\u201363","journal-title":"Clin Orthop Relat Res"},{"key":"5438_CR3","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.arth.2019.01.075","volume":"34","author":"MJ Halawi","year":"2019","unstructured":"Halawi MJ, Jongbloed W, Baron S et al (2019) Patient dissatisfaction after primary total joint arthroplasty: the patient perspective. J Arthroplasty 34:1093\u20131096","journal-title":"J Arthroplasty"},{"key":"5438_CR4","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1097\/00003086-199402000-00021","volume":"299","author":"MA Ritter","year":"1994","unstructured":"Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postopera-tive alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153\u2013156","journal-title":"Clin Orthop Relat Res"},{"key":"5438_CR5","doi-asserted-by":"publisher","first-page":"2353","DOI":"10.1016\/J.ARTH.2016.05.026","volume":"31","author":"DJ Jacofsky","year":"2016","unstructured":"Jacofsky DJ, Allen M (2016) Robotics in Arthroplasty: a Comprehensive Review. J Arthroplasty 31:2353\u20132363. https:\/\/doi.org\/10.1016\/J.ARTH.2016.05.026","journal-title":"J Arthroplasty"},{"key":"5438_CR6","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1055\/s-0039-1681053","volume":"32","author":"M Bautista","year":"2019","unstructured":"Bautista M, Manrique J, Hozack WJ (2019) Robotics in total knee arthroplasty. J Knee Surg 32:600\u2013606. https:\/\/doi.org\/10.1055\/s-0039-1681053","journal-title":"J Knee Surg"},{"key":"5438_CR7","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1136\/postgradmedj-2018-136190","volume":"95","author":"Y Ren","year":"2019","unstructured":"Ren Y, Cao S, Wu J et al (2019) Efficacy and reliability of active robotic-assisted total knee arthroplasty compared with conventional total knee arthroplasty: a systematic review and meta-analysis. Postgrad Med J 95:125\u2013133","journal-title":"Postgrad Med J"},{"key":"5438_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/S40634-020-00278-Y","volume":"7","author":"J Shatrov","year":"2020","unstructured":"Shatrov J, Parker D (2020) Computer and robotic \u2013 assisted total knee arthroplasty: a review of outcomes. J Exp Orthop 7:1\u201315. https:\/\/doi.org\/10.1186\/S40634-020-00278-Y","journal-title":"J Exp Orthop"},{"key":"5438_CR9","doi-asserted-by":"publisher","first-page":"521","DOI":"10.2106\/JBJS.16.00496","volume":"99","author":"E Thienpont","year":"2017","unstructured":"Thienpont E, Schwab PE, Fennema P (2017) Efficacy of Patient-Specific Instruments in total knee arthroplasty: a systematic review and Meta-analysis. J Bone Joint Surg Am 99:521\u2013530. https:\/\/doi.org\/10.2106\/JBJS.16.00496","journal-title":"J Bone Joint Surg Am"},{"key":"5438_CR10","doi-asserted-by":"publisher","first-page":"1572","DOI":"10.1016\/j.arth.2017.12.035","volume":"33","author":"M Miura","year":"2018","unstructured":"Miura M, Hagiwara S, Nakamura J et al (2018) Interobserver and Intraobserver reliability of computed tomography\u2013based three-Dimensional Preoperative Planning for primary total knee arthroplasty. J Arthroplasty 33:1572\u20131578. https:\/\/doi.org\/10.1016\/j.arth.2017.12.035","journal-title":"J Arthroplasty"},{"key":"5438_CR11","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1007\/S00167-020-05946-1","volume":"29","author":"DAL Schoenmakers","year":"2021","unstructured":"Schoenmakers DAL, Theeuwen DMJ, Schotanus MGM et al (2021) High intra- and inter-observer reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 29:573\u2013578. https:\/\/doi.org\/10.1007\/S00167-020-05946-1","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"5438_CR12","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1002\/(SICI)1097-0258(19980115)17:1<101::AID-SIM727>3.0.CO;2-E","volume":"17","author":"SD Walter","year":"1998","unstructured":"Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101\u2013110","journal-title":"Stat Med"},{"key":"5438_CR13","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1016\/j.knee.2009.01.001","volume":"16","author":"J Victor","year":"2009","unstructured":"Victor J, Van Doninck D, Labey L et al (2009) How precise can bony landmarks be determined on a CT scan of the knee? Knee 16:358\u2013365","journal-title":"Knee"},{"key":"5438_CR14","doi-asserted-by":"publisher","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG (1977) The measurement of Observer Agreement for Categorical Data. Biometrics 33:159. https:\/\/doi.org\/10.2307\/2529310","journal-title":"Biometrics"},{"key":"5438_CR15","doi-asserted-by":"publisher","first-page":"2314","DOI":"10.1007\/S00167-013-2443-X","volume":"21","author":"MP Bonnin","year":"2013","unstructured":"Bonnin MP, Schmidt A, Basiglini L et al (2013) Mediolateral oversizing influences pain, function, and flexion after TKA. Knee Surg Sports Traumatol Arthrosc 21:2314\u20132324. https:\/\/doi.org\/10.1007\/S00167-013-2443-X","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"5438_CR16","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.2106\/JBJS.H.00434","volume":"92","author":"OM Mahoney","year":"2010","unstructured":"Mahoney OM, Kinsey T (2010) Overhang of the femoral component in total knee arthroplasty: risk factors and clinical consequences. J Bone Joint Surg Am 92:1115\u20131121. https:\/\/doi.org\/10.2106\/JBJS.H.00434","journal-title":"J Bone Joint Surg Am"},{"key":"5438_CR17","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1016\/J.ARTH.2017.12.027","volume":"33","author":"CS Nielsen","year":"2018","unstructured":"Nielsen CS, Nebergall A, Huddleston J et al (2018) Medial overhang of the tibial component is Associated with higher risk of inferior knee Injury and Osteoarthritis Outcome score Pain after knee replacement. J Arthroplasty 33:1394\u20131398. https:\/\/doi.org\/10.1016\/J.ARTH.2017.12.027","journal-title":"J Arthroplasty"},{"key":"5438_CR18","doi-asserted-by":"publisher","first-page":"2532","DOI":"10.1007\/S00167-015-3512-0","volume":"24","author":"MP Bonnin","year":"2016","unstructured":"Bonnin MP, Saffarini M, Shepherd D et al (2016) Oversizing the tibial component in TKAs: incidence, consequences and risk factors. Knee Surg Sports Traumatol Arthrosc 24:2532\u20132540. https:\/\/doi.org\/10.1007\/S00167-015-3512-0","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"5438_CR19","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/J.ARTH.2008.05.020","volume":"23","author":"ME Berend","year":"2008","unstructured":"Berend ME, Ritter MA, Hyldahl HC et al (2008) Implant migration and failure in total knee arthroplasty is related to body mass index and tibial component size. J Arthroplasty 23:104\u2013109. https:\/\/doi.org\/10.1016\/J.ARTH.2008.05.020","journal-title":"J Arthroplasty"},{"key":"5438_CR20","doi-asserted-by":"publisher","first-page":"3844","DOI":"10.1007\/S00167-016-4345-1","volume":"25","author":"MGM Schotanus","year":"2017","unstructured":"Schotanus MGM, Schoenmakers DAL, Sollie R, Kort NP (2017) Patient-specific instruments for total knee arthroplasty can accurately predict the component size as used peroperative. Knee Surg Sports Traumatol Arthrosc 25:3844\u20133848. https:\/\/doi.org\/10.1007\/S00167-016-4345-1","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"5438_CR21","doi-asserted-by":"publisher","first-page":"1699","DOI":"10.1016\/J.ARTH.2015.04.043","volume":"30","author":"AS McLawhorn","year":"2015","unstructured":"McLawhorn AS, Carroll KM, Blevins JL et al (2015) Template-Directed Instrumentation reduces cost and Improves Efficiency for Total Knee Arthroplasty: an Economic Decision Analysis and pilot study. J Arthroplasty 30:1699\u20131704. https:\/\/doi.org\/10.1016\/J.ARTH.2015.04.043","journal-title":"J Arthroplasty"},{"key":"5438_CR22","doi-asserted-by":"publisher","first-page":"3714","DOI":"10.3390\/JCM10163714","volume":"10","author":"K Cosendey","year":"2021","unstructured":"Cosendey K, Stanovici J, Mahlouly J et al (2021) Bone cuts accuracy of a system for total knee arthroplasty including an active robotic arm. J Clin Med 10:3714. https:\/\/doi.org\/10.3390\/JCM10163714","journal-title":"J Clin Med"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-024-05438-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-024-05438-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-024-05438-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,23]],"date-time":"2024-09-23T02:02:52Z","timestamp":1727056972000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-024-05438-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,15]]},"references-count":22,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2024,8]]}},"alternative-id":["5438"],"URL":"https:\/\/doi.org\/10.1007\/s00402-024-05438-8","relation":{},"ISSN":["1434-3916"],"issn-type":[{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,15]]},"assertion":[{"value":"5 December 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures were done in accordance with the local ethics committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The study was designed in consultation with Think Surgical Inc. and partially funded by Think Surgical. Data acquisition and analysis, as well as reporting were done independently by the authors. To avoid public disclosure of confidential information, Think Surgical Inc. had the opportunity to review the manuscript before its submission for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}