{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T17:31:25Z","timestamp":1790443885861,"version":"4.1.0"},"reference-count":53,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T00:00:00Z","timestamp":1722988800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T00:00:00Z","timestamp":1722988800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"University of Innsbruck and Medical University of Innsbruck"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Screw fixation of acetabular column fractures is a well-established alternative option to plate fixation providing comparable biomechanical strength and requiring less surgical exposure. For displaced acetabular fractures involving both columns open reduction and plate fixation of one column in combination with a column-crossing screw fixation of the opposite column via a single approach is a viable treatment option. Preoperative planning of posterior column screws (PCS) via an anterior approach is mandatory to assess the eligibility of the fracture for this technique and to plan the entry point and the screw trajectory. The intraoperative application requires fluoroscopic guidance using several views. A single view showing an extraarticular screw position is adequate to rule out hip joint penetration. The fluoroscopic assessment of cortical perforation of the posterior column requires several oblique views such as lateral oblique views, obturator oblique views and axial views of the posterior column or alternatively intraoperative CT scans. The application of PCS via an anterior approach is a technically demanding procedure, that allows for a relevant reduction of approach-related morbidity, surgical time and blood loss by using a single approach.<\/jats:p>","DOI":"10.1007\/s00402-024-05471-7","type":"journal-article","created":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T11:07:15Z","timestamp":1723028835000},"page":"4561-4568","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Acetabular posterior column screws via an anterior approach"],"prefix":"10.1007","volume":"144","author":[{"given":"Dietmar","family":"Krappinger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Axel","family":"G\u00e4nsslen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lukas","family":"Wilde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4793-4260","authenticated-orcid":false,"given":"Richard A.","family":"Lindtner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,7]]},"reference":[{"key":"5471_CR1","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1007\/BF02433653","volume":"316","author":"E Letournel","year":"1966","unstructured":"Letournel E (1966) [Surgical management of hip joint-acetabulum fractures]. Langenbecks Arch Chir 316:422\u2013437","journal-title":"Langenbecks Arch Chir"},{"issue":"11","key":"5471_CR2","doi-asserted-by":"publisher","first-page":"1531","DOI":"10.1007\/s00402-009-0836-6","volume":"129","author":"WD Mu","year":"2009","unstructured":"Mu WD, Wang XQ, Jia TH, Zhou DS, Cheng AX (2009) Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum. Arch Orthop Trauma Surg 129(11):1531\u20131537","journal-title":"Arch Orthop Trauma Surg"},{"issue":"10","key":"5471_CR3","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1016\/j.injury.2009.01.014","volume":"40","author":"KN Chen","year":"2009","unstructured":"Chen KN, Wang G, Cao LG, Zhang MC (2009) Differences of percutaneous retrograde screw fixation of anterior column acetabular fractures between male and female: a study of 164 virtual three-dimensional models. Injury 40(10):1067\u20131072","journal-title":"Injury"},{"issue":"1","key":"5471_CR4","first-page":"244","volume":"70","author":"U Culemann","year":"2011","unstructured":"Culemann U, Marintschev I, Gras F, Pohlemann T (2011) Infra-acetabular corridor\u2013technical tip for an additional screw placement to increase the fixation strength of acetabular fractures. J Trauma 70(1):244\u2013246","journal-title":"J Trauma"},{"issue":"3","key":"5471_CR5","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1016\/j.injury.2017.01.024","volume":"48","author":"AS Hammad","year":"2017","unstructured":"Hammad AS, El-Khadrawe TA, Waly AH, Abu-Sheasha GA (2017) The efficacy of posterior plating and anterior column screw fixation in the management of T-shaped acetabular fractures - CART analysis of prospective cohort study. Injury 48(3):680\u2013686","journal-title":"Injury"},{"key":"5471_CR6","doi-asserted-by":"crossref","unstructured":"Guimar\u00e3es JAM, Martin MP 3rd, da Silva FR et al (2019) The obturator oblique and iliac oblique\/outlet views predict most accurately the adequate position of an anterior column acetabular screw. Int Orthop 43(5):1205\u20131213","DOI":"10.1007\/s00264-018-3989-5"},{"issue":"4","key":"5471_CR7","doi-asserted-by":"publisher","first-page":"103288","DOI":"10.1016\/j.otsr.2022.103288","volume":"108","author":"G Cavali\u00e9","year":"2022","unstructured":"Cavali\u00e9 G, Boudissa M, Kerschbaumer G, Seurat O, Ruatti S, Tonetti J (2022) Clinical and radiological outcomes of antegrade posterior column screw fixation of the acetabulum. Orthop Traumatol Surg Res 108(4):103288","journal-title":"Orthop Traumatol Surg Res"},{"issue":"10","key":"5471_CR8","doi-asserted-by":"publisher","first-page":"2158","DOI":"10.1016\/j.injury.2020.07.008","volume":"51","author":"H Le Quang","year":"2020","unstructured":"Le Quang H, Schmoelz W, Lindtner RA, Schwendinger P, Blauth M, Krappinger D (2020) Biomechanical comparison of fixation techniques for transverse acetabular fractures - single-leg stance vs. sit-to-stand loading. Injury 51(10):2158\u20132164","journal-title":"Injury"},{"issue":"4","key":"5471_CR9","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1016\/j.injury.2020.12.041","volume":"52","author":"H Le Quang","year":"2021","unstructured":"Le Quang H, Schmoelz W, Lindtner RA, Dammerer D, Schwendinger P, Krappinger D (2021) Single column plate plus other column lag screw fixation vs. both column plate fixation for anterior column with posterior hemitransverse acetabular fractures - a biomechanical analysis using different loading protocols. Injury 52(4):699\u2013704","journal-title":"Injury"},{"key":"5471_CR10","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/1749-799X-5-30","volume":"5","author":"K Khajavi","year":"2010","unstructured":"Khajavi K, Lee AT, Lindsey DP, Leucht P, Bellino MJ, Giori NJ (2010) Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis. J Orthop Surg Res 5:30","journal-title":"J Orthop Surg Res"},{"issue":"6","key":"5471_CR11","doi-asserted-by":"publisher","first-page":"1664","DOI":"10.1097\/TA.0b013e3182463b45","volume":"72","author":"F Gras","year":"2012","unstructured":"Gras F, Marintschev I, Schwarz CE, Hofmann GO, Pohlemann T, Culemann U (2012) Screw- versus plate-fixation strength of acetabular anterior column fractures: a biomechanical study. J Trauma Acute Care Surg 72(6):1664\u20131670","journal-title":"J Trauma Acute Care Surg"},{"issue":"7","key":"5471_CR12","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1016\/j.otsr.2018.06.013","volume":"104","author":"CA Becker","year":"2018","unstructured":"Becker CA, Kammerlander C, Cavalcanti Ku\u00dfmaul A et al (2018) Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures - a biomechanical study. Orthop Traumatol Surg Res 104(7):1055\u20131061","journal-title":"Orthop Traumatol Surg Res"},{"issue":"1","key":"5471_CR13","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/s12891-019-2422-6","volume":"20","author":"T Busuttil","year":"2019","unstructured":"Busuttil T, Teuben M, Pfeifer R, Cinelli P, Pape HC, Osterhoff G (2019) Screw fixation of ACPHT acetabular fractures offers sufficient biomechanical stability when compared to standard buttress plate fixation. BMC Musculoskelet Disord 20(1):39","journal-title":"BMC Musculoskelet Disord"},{"issue":"3","key":"5471_CR14","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/s00264-021-05298-6","volume":"46","author":"T Wang","year":"2022","unstructured":"Wang T, Zhao B, Yan J, Shao B, Mu W (2022) Finite element analysis of infra-acetabular screw fixation for the treatment of acetabular posterior column fracture. Int Orthop 46(3):623\u2013634","journal-title":"Int Orthop"},{"key":"5471_CR15","doi-asserted-by":"publisher","first-page":"100580","DOI":"10.1016\/j.tcr.2021.100580","volume":"37","author":"J Ye","year":"2022","unstructured":"Ye J, Xie L, Liu Z, Lin J, Yan H, Chen Z (2022) Anterograde lag screw placement in the posterior column of the acetabulum: a case report and literature review. Trauma Case Rep 37:100580","journal-title":"Trauma Case Rep"},{"issue":"1","key":"5471_CR16","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1186\/s13018-023-03879-2","volume":"18","author":"T Berk","year":"2023","unstructured":"Berk T, Zderic I, Schwarzenberg P et al (2023) Simulated full weight bearing following posterior column acetabular fracture fixation: a biomechanical comparability study. J Orthop Surg Res 18(1):401","journal-title":"J Orthop Surg Res"},{"key":"5471_CR17","doi-asserted-by":"crossref","unstructured":"Hinz N, Baumeister D, Dehoust J et al (2024) The infraacetabular screw versus the antegrade posterior column screw in acetabulum fractures with posterior column involvement: a biomechanical comparison. Arch Orthop Trauma Surg","DOI":"10.1007\/s00402-024-05324-3"},{"issue":"2","key":"5471_CR18","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1007\/s00402-014-2127-0","volume":"135","author":"Z Zheng","year":"2015","unstructured":"Zheng Z, Wu W, Yu X et al (2015) Axial view of acetabular anterior column: a new X-ray projection of percutaneous screw placement. Arch Orthop Trauma Surg 135(2):187\u2013192","journal-title":"Arch Orthop Trauma Surg"},{"issue":"8","key":"5471_CR19","doi-asserted-by":"publisher","first-page":"1347","DOI":"10.1007\/s11548-015-1149-6","volume":"10","author":"X Feng","year":"2015","unstructured":"Feng X, Fang J, Lin C et al (2015) Axial perspective to find the largest intraosseous space available for percutaneous screw fixation of fractures of the acetabular anterior column. Int J Comput Assist Radiol Surg 10(8):1347\u20131353","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"4","key":"5471_CR20","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1007\/s11548-015-1308-9","volume":"11","author":"Y Peng","year":"2016","unstructured":"Peng Y, Zhang L, Min W, Tang P (2016) Comparison of anterograde versus retrograde percutaneous screw fixation of anterior column acetabular fractures. Int J Comput Assist Radiol Surg 11(4):635\u2013639","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"5471_CR21","doi-asserted-by":"publisher","first-page":"1086","DOI":"10.1111\/os.12943","volume":"13","author":"X Wang","year":"2021","unstructured":"Wang X, Ran G, Chen X et al (2021) Obturator Oblique and Pubic Ramus Inlet views can Better Guide the insertion of an Anterior Column Acetabular Screw. Orthop Surg 13(3):1086\u20131093","journal-title":"Orthop Surg"},{"issue":"1","key":"5471_CR22","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1186\/s13018-022-03347-3","volume":"17","author":"K Yu","year":"2022","unstructured":"Yu K, Zhou R, Gao S, Liang A, Yang M, Yang H (2022) The placement of percutaneous retrograde acetabular posterior column screw based on imaging anatomical study of acetabular posterior column corridor. J Orthop Surg Res 17(1):492","journal-title":"J Orthop Surg Res"},{"issue":"9","key":"5471_CR23","doi-asserted-by":"publisher","first-page":"5713","DOI":"10.1007\/s00402-023-04939-2","volume":"143","author":"S Cattaneo","year":"2023","unstructured":"Cattaneo S, Galante C, Biancardi E et al (2023) Use of the iliac-outlet and iliac-inlet combined views in percutaneous posterior column retrograde screw fixation. Arch Orthop Trauma Surg 143(9):5713\u20135717","journal-title":"Arch Orthop Trauma Surg"},{"issue":"8","key":"5471_CR24","doi-asserted-by":"publisher","first-page":"1625","DOI":"10.1016\/j.injury.2015.04.042","volume":"46","author":"G Osterhoff","year":"2015","unstructured":"Osterhoff G, Amiri S, Unno F et al (2015) The Down the PC view - a new tool to assess screw positioning in the posterior column of the acetabulum. Injury 46(8):1625\u20131628","journal-title":"Injury"},{"issue":"11","key":"5471_CR25","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.2106\/00004623-199611000-00002","volume":"78","author":"JM Matta","year":"1996","unstructured":"Matta JM (1996) Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury. J Bone Joint Surg Am 78(11):1632\u20131645","journal-title":"J Bone Joint Surg Am"},{"issue":"17","key":"5471_CR26","doi-asserted-by":"publisher","first-page":"1559","DOI":"10.2106\/JBJS.K.00444","volume":"94","author":"M Tannast","year":"2012","unstructured":"Tannast M, Najibi S, Matta JM (2012) Two to twenty-year survivorship of the hip in 810 patients with operatively treated acetabular fractures. J Bone Joint Surg Am 94(17):1559\u20131567","journal-title":"J Bone Joint Surg Am"},{"issue":"11","key":"5471_CR27","doi-asserted-by":"publisher","first-page":"922","DOI":"10.2106\/JBJS.17.00692","volume":"100","author":"DO Verbeek","year":"2018","unstructured":"Verbeek DO, van der List JP, Tissue CM, Helfet DL (2018) Predictors for long-term hip survivorship following Acetabular fracture surgery: importance of gap compared with step displacement. J Bone Joint Surg Am 100(11):922\u2013929","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"5471_CR28","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1016\/j.injury.2017.01.028","volume":"48","author":"GH Jung","year":"2017","unstructured":"Jung GH, Lee Y, Kim JW, Kim JW (2017) Computational analysis of the safe zone for the antegrade lag screw in posterior column fixation with the anterior approach in acetabular fracture: a cadaveric study. Injury 48(3):608\u2013614","journal-title":"Injury"},{"issue":"1","key":"5471_CR29","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1186\/s12891-022-05313-w","volume":"23","author":"ZJ Liu","year":"2022","unstructured":"Liu ZJ, Gu Y, Jia J (2022) The Kocher-Langenbeck approach combined with robot-aided percutaneous anterior column screw fixation for transverse-oriented acetabular fractures: a retrospective study. BMC Musculoskelet Disord 23(1):345","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"5471_CR30","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1007\/s00264-015-2813-8","volume":"40","author":"H Chen","year":"2016","unstructured":"Chen H, Wang G, Li R et al (2016) A novel navigation template for fixation of acetabular posterior column fractures with antegrade lag screws: design and application. Int Orthop 40(4):827\u2013834","journal-title":"Int Orthop"},{"issue":"1","key":"5471_CR31","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1186\/s13018-023-04208-3","volume":"18","author":"Y Sun","year":"2023","unstructured":"Sun Y, Chen J, Liu F, Chen Z, Li X, Lv F (2023) Study of anatomical parameters and intraoperative fluoroscopic techniques for transiliac crest anterograde lag screws fixation of the posterior column of the acetabulum. J Orthop Surg Res 18(1):697","journal-title":"J Orthop Surg Res"},{"issue":"11","key":"5471_CR32","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1016\/j.injury.2010.08.011","volume":"41","author":"L Pierannunzii","year":"2010","unstructured":"Pierannunzii L, Fischer F, Tagliabue L, Calori GM, d\u2019Imporzano M (2010) Acetabular both-column fractures: essentials of operative management. Injury 41(11):1145\u20131149","journal-title":"Injury"},{"issue":"1","key":"5471_CR33","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1186\/s13018-018-0786-1","volume":"13","author":"F Baumann","year":"2018","unstructured":"Baumann F, Schmitz P, Mahr D et al (2018) A guideline for placement of an infra-acetabular screw based on anatomic landmarks via an intra-pelvic approach. J Orthop Surg Res 13(1):77","journal-title":"J Orthop Surg Res"},{"key":"5471_CR34","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-75435-7","volume-title":"Fractures of the Acetabulum","author":"E Letournel","year":"1993","unstructured":"Letournel E, Judet R (1993) Fractures of the Acetabulum. Springer, Berlin Heidelberg"},{"issue":"1","key":"5471_CR35","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1186\/s13018-018-0833-y","volume":"13","author":"S Arlt","year":"2018","unstructured":"Arlt S, Noser H, Wienke A, Radetzki F, Hofmann GO, Mendel T (2018) Secure corridor for infraacetabular screws in acetabular fracture fixation-a 3-D radiomorphometric analysis of 124 pelvic CT datasets. J Orthop Surg Res 13(1):119","journal-title":"J Orthop Surg Res"},{"issue":"5","key":"5471_CR36","doi-asserted-by":"publisher","first-page":"3757","DOI":"10.1007\/s00068-021-01805-x","volume":"48","author":"I Graul","year":"2022","unstructured":"Graul I, Marintschev I, Pizanis A, Herath SC, Pohlemann T, Fritz T (2022) The effect of an infra-acetabular screw for anatomically shaped three-dimensional plate or standard plate designs in acetabulum fractures: a biomechanical analysis. Eur J Trauma Emerg Surg 48(5):3757\u20133764","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"5","key":"5471_CR37","doi-asserted-by":"publisher","first-page":"1319","DOI":"10.1007\/s00068-020-01455-5","volume":"47","author":"JD Bastian","year":"2021","unstructured":"Bastian JD, N\u00e4f DR, Cullmann JL, Keel MJ, Giannoudis PV (2021) Does increased acetabular depth affect safe infra-acetabular screw placement in acetabular fracture fixation? Eur J Trauma Emerg Surg 47(5):1319\u20131326","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"1","key":"5471_CR38","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1007\/s11999-014-3932-z","volume":"473","author":"F Gras","year":"2015","unstructured":"Gras F, Gottschling H, Schr\u00f6der M, Marintschev I, Reimers N, Burgkart R (2015) Sex-specific differences of the infraacetabular corridor: a biomorphometric CT-based analysis on a database of 523 pelves. Clin Orthop Relat Res 473(1):361\u2013369","journal-title":"Clin Orthop Relat Res"},{"key":"5471_CR39","volume-title":"Acetabular fractures","author":"A G\u00e4nsslen","year":"2018","unstructured":"G\u00e4nsslen A, Hildebrand F, Klebingat M, Nerlich M, Lindahl J (2018) Chap. 22: special screws and views. In: G\u00e4nsslen A, M\u00fcller M, Nerlich M, Lindahl J (eds) Acetabular fractures. Georg Thieme Verlag KG, Stuttgart"},{"issue":"4","key":"5471_CR40","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1007\/s00264-012-1740-1","volume":"37","author":"T Dienstknecht","year":"2013","unstructured":"Dienstknecht T, M\u00fcller M, Sellei R et al (2013) Screw placement in percutaneous acetabular surgery: gender differences of anatomical landmarks in a cadaveric study. Int Orthop 37(4):673\u2013679","journal-title":"Int Orthop"},{"issue":"6","key":"5471_CR41","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1007\/s00402-012-1486-7","volume":"132","author":"P Puchwein","year":"2012","unstructured":"Puchwein P, Enninghorst N, Sisak K et al (2012) Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion. Arch Orthop Trauma Surg 132(6):805\u2013811","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"5471_CR42","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.injury.2009.08.004","volume":"41","author":"A Shahulhameed","year":"2010","unstructured":"Shahulhameed A, Roberts CS, Pomeroy CL, Acland RD, Giannoudis PV (2010) Mapping the columns of the acetabulum\u2013implications for percutaneous fixation. Injury 41(4):339\u2013342","journal-title":"Injury"},{"key":"5471_CR43","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1186\/s12891-015-0697-9","volume":"16","author":"BG Ochs","year":"2015","unstructured":"Ochs BG, Stuby FM, Stoeckle U, Gonser CE (2015) Virtual mapping of 260 three-dimensional hemipelvises to analyse gender-specific differences in minimally invasive retrograde lag screw placement in the posterior acetabular column using the anterior pelvic and midsagittal plane as reference. BMC Musculoskelet Disord 16:240","journal-title":"BMC Musculoskelet Disord"},{"issue":"11","key":"5471_CR44","doi-asserted-by":"publisher","first-page":"3774","DOI":"10.1016\/j.injury.2022.08.056","volume":"53","author":"EJ Lim","year":"2022","unstructured":"Lim EJ, Sakong S, Choi W et al (2022) The difference in the corridor of the antegrade posterior column screw according to the presence of pelvic dysmorphism. Injury 53(11):3774\u20133780","journal-title":"Injury"},{"issue":"3","key":"5471_CR45","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1016\/j.injury.2016.01.026","volume":"47","author":"X Feng","year":"2016","unstructured":"Feng X, Zhang S, Luo Q et al (2016) Definition of a safe zone for antegrade lag screw fixation of fracture of posterior column of the acetabulum by 3D technology. Injury 47(3):702\u2013706","journal-title":"Injury"},{"key":"5471_CR46","doi-asserted-by":"publisher","first-page":"110579","DOI":"10.1016\/j.injury.2023.01.017","volume":"54","author":"G Boni","year":"2023","unstructured":"Boni G, Pires RE, Sanchez GT, Giordano V (2023) Antegrade posterior column screw fixation for acetabular fractures: it\u2019s time to standardize the surgical technique. Injury 54:110579","journal-title":"Injury"},{"issue":"6","key":"5471_CR47","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1007\/s00064-019-00631-0","volume":"31","author":"D Krappinger","year":"2019","unstructured":"Krappinger D, Schwendinger P, Lindtner RA (2019) Fluoroscopically guided acetabular posterior column screw fixation via an anterior approach. Oper Orthop Traumatol 31(6):503\u2013512","journal-title":"Oper Orthop Traumatol"},{"key":"5471_CR48","doi-asserted-by":"publisher","first-page":"106503","DOI":"10.1016\/j.ijscr.2021.106503","volume":"88","author":"H Do Phuoc","year":"2021","unstructured":"Do Phuoc H, Nguyen Hoang P, Cao Ba H (2021) The use of a 3D-printed personalised drill guide for posterior column lag screw fixation in displaced transverse acetabular fracture: a case report. Int J Surg Case Rep 88:106503","journal-title":"Int J Surg Case Rep"},{"issue":"2","key":"5471_CR49","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1055\/s-2008-1038370","volume":"146","author":"F Gras","year":"2008","unstructured":"Gras F, Marintschev I, Mendler F, Wilharm A, M\u00fcckley T, Hofmann GO (2008) [2D-fluoroscopic navigated screw osteosynthesis of acetabular fractures: a preliminary report]. Z Orthop Unfall 146(2):231\u2013239","journal-title":"Z Orthop Unfall"},{"issue":"1","key":"5471_CR50","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1097\/00005131-199801000-00009","volume":"12","author":"AJ Starr","year":"1998","unstructured":"Starr AJ, Reinert CM, Jones AL (1998) Percutaneous fixation of the columns of the acetabulum: a new technique. J Orthop Trauma 12(1):51\u201358","journal-title":"J Orthop Trauma"},{"issue":"11","key":"5471_CR51","doi-asserted-by":"publisher","first-page":"1330","DOI":"10.1016\/j.injury.2004.09.016","volume":"36","author":"E Mouhsine","year":"2005","unstructured":"Mouhsine E, Garofalo R, Borens O et al (2005) Percutaneous retrograde screwing for stabilisation of acetabular fractures. Injury 36(11):1330\u20131336","journal-title":"Injury"},{"issue":"6","key":"5471_CR52","doi-asserted-by":"publisher","first-page":"1502","DOI":"10.1097\/TA.0b013e318246efe5","volume":"72","author":"JA Bishop","year":"2012","unstructured":"Bishop JA, Routt ML Jr. (2012) Osseous fixation pathways in pelvic and acetabular fracture surgery: osteology, radiology, and clinical applications. J Trauma Acute Care Surg 72(6):1502\u20131509","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"5471_CR53","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1007\/s00264-023-06002-6","volume":"48","author":"A Elmhiregh","year":"2024","unstructured":"Elmhiregh A, Hantouly AT, Alzoubi O, George B, Ahmadi M, Ahmed G (2024) The optimal fluoroscopic views to rule out intra-articular screw penetration during acetabular fracture fixation. Int Orthop 48(1):243\u2013252","journal-title":"Int Orthop"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-024-05471-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-024-05471-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-024-05471-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,19]],"date-time":"2024-11-19T23:03:12Z","timestamp":1732057392000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-024-05471-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,7]]},"references-count":53,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2024,10]]}},"alternative-id":["5471"],"URL":"https:\/\/doi.org\/10.1007\/s00402-024-05471-7","relation":{},"ISSN":["1434-3916"],"issn-type":[{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,7]]},"assertion":[{"value":"4 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest. No funding was received for this work.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}