{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T16:50:07Z","timestamp":1792687807771,"version":"4.5.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T00:00:00Z","timestamp":1723161600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T00:00:00Z","timestamp":1723161600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Introduction<\/jats:title>\n                <jats:p>This is a retrospective cohort study designed to compare short-term postoperative complication rates between closed humeral shaft fractures treated by open reduction and internal fixation (ORIF) versus intramedullary nailing (IMN), as well as secondary independent risk factors for adverse outcomes.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>The American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database was queried using CPT codes to identify patients that underwent an open reduction and plate fixation or intramedullary nailing procedure for a closed humeral shaft fracture from 2010 to 2021. Cohorts were matched using propensity scores to account for demographic differences and rates of complications were compared between the two groups.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>From the database, a total of 4,222 patients were identified who met inclusion criteria, with 3,326 and 896 undergoing ORIF and IMN respectively. After propensity score matching, 866 of the nearest-neighbor matches were included in each cohort for a total of 1,732 patients in the final analysis. The rate of any adverse event (AAE) was significantly higher in the ORIF cohort (16.3%) than the IMN cohort (12.1%, <jats:italic>p<\/jats:italic>\u2009=\u20090.01). The ORIF group had higher rates of postoperative transfusion (<jats:italic>p<\/jats:italic>\u2009=\u20090.002), return to OR (<jats:italic>p<\/jats:italic>\u2009=\u20090.005), and surgical site infection (SSI, <jats:italic>p<\/jats:italic>\u2009=\u20090.03). After multivariate analysis, ASA class 4, increasing age, increasing operative time, and history of bleeding disorder were found to increase the risk of AAE in both ORIF and IMN patients.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>While prior studies have claimed higher complication rates in IMN patients, this study found a significantly higher short-term risk of AAE in ORIF patients when compared in matched cohorts. However, individual 30-day complication rates do not differ significantly between procedures, and both have been shown to be safe and effective tools in the management of humeral shaft fractures.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00402-024-05491-3","type":"journal-article","created":{"date-parts":[[2024,8,9]],"date-time":"2024-08-09T16:02:01Z","timestamp":1723219321000},"page":"3361-3368","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Short-term complication rates of open reduction and plate fixation and intramedullary nailing in the treatment of humeral shaft fractures: a propensity score matched analysis"],"prefix":"10.1007","volume":"144","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-9847-6053","authenticated-orcid":false,"given":"Sarah","family":"Whitaker","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Cole","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Conor","family":"O\u2019Neill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Satalich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. Cole","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Vanderbeck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,9]]},"reference":[{"issue":"11","key":"5491_CR1","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1302\/0301-620X.88B11.17634","volume":"88\u2013B","author":"R Ekholm","year":"2006","unstructured":"Ekholm R, Adami J, Tidermark J, Hansson K, T\u00f6rnkvist H, Ponzer S (2006) Fractures of the shaft of the humerus: AN EPIDEMIOLOGICAL STUDY OF 401 FRACTURES. J Bone Joint Surg Br 88\u2013B(11):1469\u20131473. https:\/\/doi.org\/10.1302\/0301-620X.88B11.17634","journal-title":"J Bone Joint Surg Br"},{"issue":"8","key":"5491_CR2","doi-asserted-by":"publisher","first-page":"661","DOI":"10.22038\/ABJS.2021.59413.2947","volume":"10","author":"KM Amer","year":"2022","unstructured":"Amer KM, Kurland AM, Smith B et al (2022) Intramedullary Nailing Versus plate fixation for Humeral Shaft fractures: a systematic review and Meta-analysis. Arch Bone Jt Surg 10(8):661\u2013667. https:\/\/doi.org\/10.22038\/ABJS.2021.59413.2947","journal-title":"Arch Bone Jt Surg"},{"issue":"11","key":"5491_CR3","doi-asserted-by":"publisher","first-page":"e599","DOI":"10.1097\/MD.0000000000000599","volume":"94","author":"JG Zhao","year":"2015","unstructured":"Zhao JG, Wang J, Wang C, Kan SL (2015) Intramedullary nail Versus plate fixation for Humeral Shaft fractures: a systematic review of overlapping Meta-analyses. Med (Baltim) 94(11):e599. https:\/\/doi.org\/10.1097\/MD.0000000000000599","journal-title":"Med (Baltim)"},{"issue":"4","key":"5491_CR4","doi-asserted-by":"publisher","first-page":"e87","DOI":"10.1016\/j.jse.2017.10.028","volume":"27","author":"GF Updegrove","year":"2018","unstructured":"Updegrove GF, Mourad W, Abboud JA (2018) Humeral shaft fractures. J Shoulder Elb Surg 27(4):e87\u2013e97. https:\/\/doi.org\/10.1016\/j.jse.2017.10.028","journal-title":"J Shoulder Elb Surg"},{"issue":"7","key":"5491_CR5","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1016\/j.otsr.2019.12.016","volume":"106","author":"R Zhang","year":"2020","unstructured":"Zhang R, Yin Y, Li S, Hou Z, Jin L, Zhang Y (2020) Intramedullary nailing versus a locking compression plate for humeral shaft fracture (AO\/OTA 12-A and B): a retrospective study. Orthop Traumatol Surg Res 106(7):1391\u20131397. https:\/\/doi.org\/10.1016\/j.otsr.2019.12.016","journal-title":"Orthop Traumatol Surg Res"},{"issue":"4","key":"5491_CR6","doi-asserted-by":"publisher","first-page":"356","DOI":"10.2106\/JBJS.20.02087","volume":"103","author":"W Obremskey","year":"2021","unstructured":"Obremskey W (2021) Closed Humeral Shaft fractures, internal fixation surgery did not improve functional outcomes at 12 months compared with nonoperative functional bracing. JBJS 103(4):356. https:\/\/doi.org\/10.2106\/JBJS.20.02087","journal-title":"JBJS"},{"issue":"3","key":"5491_CR7","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1007\/s00264-006-0200-1","volume":"31","author":"M Changulani","year":"2007","unstructured":"Changulani M, Jain UK, Keswani T (2007) Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study. Int Orthop 31(3):391\u2013395. https:\/\/doi.org\/10.1007\/s00264-006-0200-1","journal-title":"Int Orthop"},{"issue":"2","key":"5491_CR8","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1177\/230949900901700202","volume":"17","author":"AB Putti","year":"2009","unstructured":"Putti AB, Uppin RB, Putti BB (2009) Locked intramedullary nailing versus dynamic compression plating for humeral shaft fractures. J Orthop Surg Hong Kong 17(2):139\u2013141. https:\/\/doi.org\/10.1177\/230949900901700202","journal-title":"J Orthop Surg Hong Kong"},{"issue":"46","key":"5491_CR9","doi-asserted-by":"publisher","first-page":"e17952","DOI":"10.1097\/MD.0000000000017952","volume":"98","author":"H Wen","year":"2019","unstructured":"Wen H, Zhu S, Li C, Chen Z, Yang H, Xu Y (2019) Antegrade intramedullary nail versus plate fixation in the treatment of humeral shaft fractures: an update meta-analysis. Med (Baltim) 98(46):e17952. https:\/\/doi.org\/10.1097\/MD.0000000000017952","journal-title":"Med (Baltim)"},{"issue":"4","key":"5491_CR10","doi-asserted-by":"publisher","first-page":"942","DOI":"10.1016\/j.injury.2020.02.001","volume":"51","author":"RK Merrill","year":"2020","unstructured":"Merrill RK, Low SL, Arvind V, Whitaker CM, Illical EM (2020) Length of stay and 30-day readmissions after isolated humeral shaft fracture open reduction and internal fixation compared to intramedullary nailing. Injury 51(4):942\u2013946. https:\/\/doi.org\/10.1016\/j.injury.2020.02.001","journal-title":"Injury"},{"issue":"4","key":"5491_CR11","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1007\/s00264-009-0813-2","volume":"34","author":"K Singisetti","year":"2010","unstructured":"Singisetti K, Ambedkar M (2010) Nailing versus plating in humerus shaft fractures: a prospective comparative study. Int Orthop 34(4):571\u2013576. https:\/\/doi.org\/10.1007\/s00264-009-0813-2","journal-title":"Int Orthop"},{"issue":"3","key":"5491_CR12","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/j.jse.2012.06.007","volume":"22","author":"H Ouyang","year":"2013","unstructured":"Ouyang H, Xiong J, Xiang P, Cui Z, Chen L, Yu B (2013) Plate versus intramedullary nail fixation in the treatment of humeral shaft fractures: an updated meta-analysis. J Shoulder Elb Surg 22(3):387\u2013395. https:\/\/doi.org\/10.1016\/j.jse.2012.06.007","journal-title":"J Shoulder Elb Surg"},{"issue":"4","key":"5491_CR13","doi-asserted-by":"publisher","first-page":"2667","DOI":"10.1007\/s00068-021-01728-7","volume":"48","author":"FJP Beeres","year":"2022","unstructured":"Beeres FJP, van Veelen N, Houwert RM et al (2022) Open plate fixation versus nailing for humeral shaft fractures: a meta-analysis and systematic review of randomised clinical trials and observational studies. Eur J Trauma Emerg Surg off Publ Eur Trauma Soc 48(4):2667\u20132682. https:\/\/doi.org\/10.1007\/s00068-021-01728-7","journal-title":"Eur J Trauma Emerg Surg off Publ Eur Trauma Soc"},{"issue":"3","key":"5491_CR14","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1302\/0301-620x.82b3.9675","volume":"82","author":"RG McCormack","year":"2000","unstructured":"McCormack RG, Brien D, Buckley RE, McKee MD, Powell J, Schemitsch EH (2000) Fixation of fractures of the shaft of the humerus by dynamic compression plate or intramedullary nail. A prospective, randomised trial. J Bone Joint Surg Br 82(3):336\u2013339. https:\/\/doi.org\/10.1302\/0301-620x.82b3.9675","journal-title":"J Bone Joint Surg Br"},{"issue":"3","key":"5491_CR15","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1007\/s00776-013-0355-8","volume":"18","author":"X Wang","year":"2013","unstructured":"Wang X, Chen Z, Shao Y, Xia Q, Ma Y, Fu D (2013) A meta-analysis of plate fixation versus intramedullary nailing for humeral shaft fractures. J Orthop Sci 18(3):388\u2013397. https:\/\/doi.org\/10.1007\/s00776-013-0355-8","journal-title":"J Orthop Sci"},{"issue":"8","key":"5491_CR16","doi-asserted-by":"publisher","first-page":"1460","DOI":"10.1016\/j.injury.2019.06.014","volume":"50","author":"JG Putnam","year":"2019","unstructured":"Putnam JG, Nowak L, Sanders D et al (2019) Early post-operative outcomes of plate versus nail fixation for humeral shaft fractures. Injury 50(8):1460\u20131463. https:\/\/doi.org\/10.1016\/j.injury.2019.06.014","journal-title":"Injury"},{"issue":"1","key":"5491_CR17","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1007\/s00590-020-02734-y","volume":"31","author":"R Burgmeier","year":"2021","unstructured":"Burgmeier R, Bolia IK, Gipsman A, Jalali O, Weber AE (2021) Plate fixation versus intramedullary nailing of proximal humerus fractures: an ACS NSQIP-based comparative analysis over 8 years. Eur J Orthop Surg Traumatol 31(1):33\u201341. https:\/\/doi.org\/10.1007\/s00590-020-02734-y","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"5491_CR18","unstructured":"User Guide for the 2014 ACS NSQIP Participant Use Data File (PUF). Published online October 2015"},{"issue":"5","key":"5491_CR19","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1016\/j.surg.2005.08.016","volume":"138","author":"SF Khuri","year":"2005","unstructured":"Khuri SF (2005) The NSQIP: a new frontier in surgery. Surgery 138(5):837\u2013843. https:\/\/doi.org\/10.1016\/j.surg.2005.08.016","journal-title":"Surgery"},{"issue":"5","key":"5491_CR20","doi-asserted-by":"publisher","first-page":"1574","DOI":"10.1007\/s11999-014-3597-7","volume":"473","author":"CS Molina","year":"2015","unstructured":"Molina CS, Thakore RV, Blumer A, Obremskey WT, Sethi MK (2015) Use of the National Surgical Quality Improvement Program in Orthopaedic surgery. Clin Orthop Relat Res 473(5):1574. https:\/\/doi.org\/10.1007\/s11999-014-3597-7","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"5491_CR21","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1016\/j.jamcollsurg.2007.01.012","volume":"204","author":"CL Davis","year":"2007","unstructured":"Davis CL, Pierce JR, Henderson W et al (2007) Assessment of the Reliability of Data Collected for the Department of Veterans Affairs National Surgical Quality Improvement Program. J Am Coll Surg 204(4):550. https:\/\/doi.org\/10.1016\/j.jamcollsurg.2007.01.012","journal-title":"J Am Coll Surg"},{"issue":"2","key":"5491_CR22","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1177\/1062860615623854","volume":"32","author":"AW Trickey","year":"2017","unstructured":"Trickey AW, Wright JM, Donovan J et al (2017) Interrater Reliability of Hospital Readmission Evaluations for Surgical patients. Am J Med Qual 32(2):201\u2013207. https:\/\/doi.org\/10.1177\/1062860615623854","journal-title":"Am J Med Qual"},{"key":"5491_CR23","unstructured":"ACS NSQIP | ACS. Accessed July 21 (2023) https:\/\/www.facs.org\/quality-programs\/data-and-registries\/acs-nsqip\/"},{"issue":"5","key":"5491_CR24","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1001\/jama.2015.25","volume":"313","author":"NH Osborne","year":"2015","unstructured":"Osborne NH, Nicholas LH, Ryan AM, Thumma JR, Dimick JB (2015) Association of Hospital Participation in a Quality Reporting Program with Surgical outcomes and expenditures for Medicare Beneficiaries. JAMA 313(5):496\u2013504. https:\/\/doi.org\/10.1001\/jama.2015.25","journal-title":"JAMA"},{"issue":"11","key":"5491_CR25","doi-asserted-by":"publisher","first-page":"2122","DOI":"10.1097\/CORR.0000000000002391","volume":"480","author":"DJ Cognetti","year":"2022","unstructured":"Cognetti DJ, Arana AA, Hoof M, Mason G, Lin A, Sheean AJ (2022) Short-term complications for proximal Humerus fracture surgery have decreased: an analysis of the National Surgical Quality Improvement Program Database. Clin Orthop Relat Res 480(11):2122. https:\/\/doi.org\/10.1097\/CORR.0000000000002391","journal-title":"Clin Orthop Relat Res"},{"issue":"10","key":"5491_CR26","doi-asserted-by":"publisher","first-page":"e356","DOI":"10.1097\/BOT.0000000000002072","volume":"35","author":"P Bovonratwet","year":"2021","unstructured":"Bovonratwet P, Suhardi VJ, Andarawis-Puri N, Ricci WM, Fu MC (2021) Outpatient Surgical fixation of proximal Humerus fractures can be performed without increased rates of short-term complications or readmissions. J Orthop Trauma 35(10):e356. https:\/\/doi.org\/10.1097\/BOT.0000000000002072","journal-title":"J Orthop Trauma"},{"issue":"4","key":"5491_CR27","doi-asserted-by":"publisher","first-page":"1117","DOI":"10.1007\/s00590-022-03260-9","volume":"33","author":"P Ramamurti","year":"2023","unstructured":"Ramamurti P, Quan T, Swansen T et al (2023) Comparison of 30-day complications between reverse shoulder arthroplasty and open reduction internal fixation for the treatment of proximal humerus fractures. Eur J Orthop Surg Traumatol 33(4):1117\u20131124. https:\/\/doi.org\/10.1007\/s00590-022-03260-9","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"4","key":"5491_CR28","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1016\/j.jse.2015.09.011","volume":"25","author":"GL Cvetanovich","year":"2016","unstructured":"Cvetanovich GL, Chalmers PN, Verma NN, Nicholson GP, Romeo AA (2016) Open reduction internal fixation has fewer short-term complications than shoulder arthroplasty for proximal humeral fractures. J Shoulder Elb Surg 25(4):624\u2013631e3. https:\/\/doi.org\/10.1016\/j.jse.2015.09.011","journal-title":"J Shoulder Elb Surg"},{"issue":"17","key":"5491_CR29","doi-asserted-by":"publisher","first-page":"e71","DOI":"10.2106\/JBJS.15.01049","volume":"98","author":"MB Gottschalk","year":"2016","unstructured":"Gottschalk MB, Carpenter W, Hiza E, Reisman W, Roberson J (2016) Humeral Shaft fracture fixation: incidence rates and complications as reported by American Board of Orthopaedic surgery part II candidates. JBJS 98(17):e71. https:\/\/doi.org\/10.2106\/JBJS.15.01049","journal-title":"JBJS"},{"issue":"1","key":"5491_CR30","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1186\/s13018-023-03663-2","volume":"18","author":"KS Oldenburg","year":"2023","unstructured":"Oldenburg KS, Welsh ME, Goodloe JB, Friedman RJ, Eichinger JK (2023) Outcome and complication comparison for intramedullary nail versus open reduction internal fixation in humeral diaphyseal fractures for 2800 matched patient pairs utilizing the Nationwide Readmissions Database. J Orthop Surg 18(1):442. https:\/\/doi.org\/10.1186\/s13018-023-03663-2","journal-title":"J Orthop Surg"},{"key":"5491_CR31","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1186\/1471-2474-12-231","volume":"12","author":"JA Singh","year":"2011","unstructured":"Singh JA, Sperling JW, Cofield RH (2011) Ninety day mortality and its predictors after primary shoulder arthroplasty: an analysis of 4,019 patients from 1976\u20132008. BMC Musculoskelet Disord 12:231. https:\/\/doi.org\/10.1186\/1471-2474-12-231","journal-title":"BMC Musculoskelet Disord"},{"issue":"10","key":"5491_CR32","doi-asserted-by":"publisher","first-page":"232596711455316","DOI":"10.1177\/2325967114553164","volume":"2","author":"E Shields","year":"2014","unstructured":"Shields E, Iannuzzi JC, Thorsness R, Noyes K, Voloshin I (2014) Postoperative morbidity by Procedure and patient factors influencing major complications within 30 days following shoulder surgery. Orthop J Sports Med 2(10):2325967114553164. https:\/\/doi.org\/10.1177\/2325967114553164","journal-title":"Orthop J Sports Med"},{"issue":"11","key":"5491_CR33","doi-asserted-by":"publisher","first-page":"e307","DOI":"10.1016\/j.jse.2015.07.012","volume":"24","author":"FMAP Claessen","year":"2015","unstructured":"Claessen FMAP, Peters RM, Verbeek DO, Helfet DL, Ring D (2015) Factors associated with radial nerve palsy after operative treatment of diaphyseal humeral shaft fractures. J Shoulder Elb Surg 24(11):e307\u2013e311. https:\/\/doi.org\/10.1016\/j.jse.2015.07.012","journal-title":"J Shoulder Elb Surg"},{"issue":"2","key":"5491_CR34","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s00068-017-0775-9","volume":"44","author":"TR Schwab","year":"2018","unstructured":"Schwab TR, Stillhard PF, Schibli S, Furrer M, Sommer C (2018) Radial nerve palsy in humeral shaft fractures with internal fixation: analysis of management and outcome. Eur J Trauma Emerg Surg 44(2):235\u2013243. https:\/\/doi.org\/10.1007\/s00068-017-0775-9","journal-title":"Eur J Trauma Emerg Surg"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-024-05491-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-024-05491-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-024-05491-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,23]],"date-time":"2024-09-23T17:04:06Z","timestamp":1727111046000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-024-05491-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,9]]},"references-count":34,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2024,8]]}},"alternative-id":["5491"],"URL":"https:\/\/doi.org\/10.1007\/s00402-024-05491-3","relation":{},"ISSN":["1434-3916"],"issn-type":[{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,9]]},"assertion":[{"value":"1 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declaration"}},{"value":"No potential conflict of interest relevant to this article was reported.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}