{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T09:10:20Z","timestamp":1766481020845,"version":"3.48.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T00:00:00Z","timestamp":1766448000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T00:00:00Z","timestamp":1766448000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"DOI":"10.1007\/s00402-025-06144-9","type":"journal-article","created":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T09:06:09Z","timestamp":1766480769000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Radiographic comparison of compression hip screws and cephalomedullary nails in stable femoral trochanteric fractures"],"prefix":"10.1007","volume":"146","author":[{"given":"Shota","family":"Nakagawa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Sawaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takushi","family":"Nakatani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryutaro","family":"Shibata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuki","family":"Yasutake","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masato","family":"Toyonaga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshitomo","family":"Sano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Matsushita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,12,23]]},"reference":[{"key":"6144_CR1","unstructured":"Japan Orthopaedic Association Clinical practice guideline on the management of hip fractures, 3rd edn. https:\/\/minds.jcqhc.or.jp\/common\/summary\/pdf\/c00625.pdf. Accessed 28 Oct 2024"},{"key":"6144_CR2","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1302\/2633-1462.310.BJO-2022-0104.R1","volume":"3","author":"TE Baldock","year":"2022","unstructured":"Baldock TE, Dixon JR, Koubaesh C, Johansen A, Eardley WGP (2022) Variation of implant use in A1 and A2 trochanteric hip fractures: a study from the National hip fracture database of England and Wales. Bone Jt Open 3:741\u2013745. https:\/\/doi.org\/10.1302\/2633-1462.310.BJO-2022-0104.R1","journal-title":"Bone Jt Open"},{"key":"6144_CR3","first-page":"361","volume-title":"Market report overview: medical bionics (artificial organs) market 2020","author":"Yano Research Institute, Ltd","year":"2020","unstructured":"Yano Research Institute, Ltd (2020) Market report overview: medical bionics (artificial organs) market 2020. Yano Research Institute Ltd., Tokyo, pp 361\u2013362"},{"key":"6144_CR4","doi-asserted-by":"publisher","first-page":"e2317164","DOI":"10.1001\/jamanetworkopen.2023.17164","volume":"6","author":"EH Schemitsch","year":"2023","unstructured":"Schemitsch EH, Nowak LL, Schulz AP, Brink O, Poolman RW, Mehta S, Stengel D, Zhang CQ, Martinez S, Kinner B, Chesser TJS, Bhandari M, INSITE Investigators (2023) Intramedullary nailing vs sliding hip screw in trochanteric fracture management: the INSITE randomized clinical trial. JAMA Netw Open 6:e2317164. https:\/\/doi.org\/10.1001\/jamanetworkopen.2023.17164","journal-title":"JAMA Netw Open"},{"key":"6144_CR5","doi-asserted-by":"publisher","unstructured":"Diffley T, Yee T, Letham C, Ali M, Cove R, Mohammed I, Kindi GA, Samara A, Cunningham C (2024) Post-COVID-19 randomized controlled trials comparing intramedullary nails and sliding hip screw constructs for intertrochanteric fractures do not represent typical patient demographics: a systematic review. Bone Joint J 106\u2013B(Supplement 6):51. https:\/\/doi.org\/10.1302\/1358-992X.2024.6.051","DOI":"10.1302\/1358-992X.2024.6.051"},{"key":"6144_CR6","doi-asserted-by":"publisher","first-page":"10999","DOI":"10.1038\/s41598-023-38209-3","volume":"13","author":"L Fang","year":"2023","unstructured":"Fang L, Qi J, Wang Z, Liu J, Zhao T, Lin Y, Hao W (2023) Inverse relationship between femoral lateralization and neck-shaft angle is a joint event after intramedullary nailing of per trochanteric fractures. Sci Rep 13:10999. https:\/\/doi.org\/10.1038\/s41598-023-38209-3","journal-title":"Sci Rep"},{"key":"6144_CR7","doi-asserted-by":"publisher","unstructured":"Buecking B, Boese CK, Seifert V, Ruchholtz S, Frink M, Lechler P (2015) Femoral offset following trochanteric femoral fractures: a prospective observational study. Injury 46 (Supplement 4):S88-S92. https:\/\/doi.org\/10.1016\/S0020-1383(15)30024-3","DOI":"10.1016\/S0020-1383(15)30024-3"},{"key":"6144_CR8","doi-asserted-by":"publisher","first-page":"215145932311867","DOI":"10.1177\/21514593231186724","volume":"14","author":"AN Pearce","year":"2023","unstructured":"Pearce AN, Sieber FE, Wang N-Y, Stambough JB, Stronach BM, Mears SC (2023) Leg length discrepancy after hip fracture repair is associated with reduced gait speed. Geriatr Orthop Surg Rehabil 14:21514593231186724. https:\/\/doi.org\/10.1177\/21514593231186724","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"6144_CR9","doi-asserted-by":"publisher","unstructured":"Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF (2018) Fracture and dislocation classification compendium-2018. J Orthop Trauma 32 (Supplement 1):S1-S170. https:\/\/doi.org\/10.1097\/BOT.0000000000001063","DOI":"10.1097\/BOT.0000000000001063"},{"key":"6144_CR10","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1097\/00000542-194105000-00004","volume":"2","author":"M Saklad","year":"1941","unstructured":"Saklad M (1941) Grading of patients for surgical procedures. Anesthesiology 2:281\u2013284. https:\/\/doi.org\/10.1097\/00000542-194105000-00004","journal-title":"Anesthesiology"},{"key":"6144_CR11","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1016\/j.injury.2019.03.032","volume":"50","author":"J Li","year":"2019","unstructured":"Li J, Tang S, Zhang H, Li Z, Deng W, Zhao C, Fan L, Wang G, Liu J, Yin P, Xu G, Zhang L, Tang P (2019) Clustering of morphological fracture lines for identifying intertrochanteric fracture classification with hausdorff distance-based K-means approach. Injury 50:939\u2013949. https:\/\/doi.org\/10.1016\/j.injury.2019.03.032","journal-title":"Injury"},{"key":"6144_CR12","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","volume":"77","author":"MR Baumgaertner","year":"1995","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. JBJS Am 77:1058\u20131064. https:\/\/doi.org\/10.2106\/00004623-199507000-00012","journal-title":"JBJS Am"},{"key":"6144_CR13","doi-asserted-by":"publisher","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM (1998) Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures. Clin Orthop Relat Res 34887\u201394. https:\/\/doi.org\/10.1097\/00003086-199803000-00015","DOI":"10.1097\/00003086-199803000-00015"},{"key":"6144_CR14","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1007\/s00402-015-2206-x","volume":"135","author":"SM Chang","year":"2015","unstructured":"Chang SM, Zhang YQ, Ma Z, Li Q, Dargel J, Eysel P (2015) Fracture reduction with positive medial cortical support: a key element in stability reconstruction for the unstable Pertrochanteric hip fractures. Arch Orthop Trauma Surg 135:811\u2013818. https:\/\/doi.org\/10.1007\/s00402-015-2206-x","journal-title":"Arch Orthop Trauma Surg"},{"key":"6144_CR15","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1093\/ptj\/64.1.35","volume":"64","author":"MK Holden","year":"1984","unstructured":"Holden MK, Gill KM, Magliozzi MR, Nathan J, Piehl-Baker L (1984) Clinical gait assessment in the neurologically impaired. Reliab Meaningfulness Phys Ther 64:35\u201340. https:\/\/doi.org\/10.1093\/ptj\/64.1.35","journal-title":"Reliab Meaningfulness Phys Ther"},{"key":"6144_CR16","doi-asserted-by":"publisher","first-page":"389","DOI":"10.3109\/17453674.2014.931196","volume":"85","author":"P Lechler","year":"2014","unstructured":"Lechler P, Frink M, Gulati A, Murray D, Renkawitz T, B\u00fccking B, Ruchholtz S, Boese CK (2014) The influence of hip rotation on femoral offset in plain radiographs. Acta Orthop 85:389\u2013395. https:\/\/doi.org\/10.3109\/17453674.2014.931196","journal-title":"Acta Orthop"},{"key":"6144_CR17","doi-asserted-by":"publisher","unstructured":"Mingo-Robinet J, Gonzalez-Alonso C, Alonso Del Olmo JA (2021) Fluoroscopic landmarks to recognize iatrogenic varus displacement (wedge effect) during cephalomedullary nailing of intertrochanteric fractures. Injury 52 (Supplement 4):S47-S53. https:\/\/doi.org\/10.1016\/j.injury.2021.03.065","DOI":"10.1016\/j.injury.2021.03.065"},{"key":"6144_CR18","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1007\/s00590-016-1746-2","volume":"26","author":"M Marmor","year":"2016","unstructured":"Marmor M, Liddle K, Buckley J, Matityahu A (2016) Effect of varus and valgus alignment on implant loading after proximal femur fracture fixation. Eur J Orthop Surg Traumatol 26:379\u2013383. https:\/\/doi.org\/10.1007\/s00590-016-1746-2","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"6144_CR19","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1016\/j.injury.2003.10.028","volume":"35","author":"H Pervez","year":"2004","unstructured":"Pervez H, Parker MJ, Vowler S (2004) Prediction of fixation failure after sliding hip screw fixation. Injury 35:994\u2013998. https:\/\/doi.org\/10.1016\/j.injury.2003.10.028","journal-title":"Injury"},{"key":"6144_CR20","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1007\/s00264-009-0866-2","volume":"34","author":"KK Hsueh","year":"2010","unstructured":"Hsueh KK, Fang CK, Chen CM, Su YP, Wu HF, Chiu FY (2010) Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. Int Orthop 34:1273\u20131276. https:\/\/doi.org\/10.1007\/s00264-009-0866-2","journal-title":"Int Orthop"},{"key":"6144_CR21","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/s00402-016-2410-3","volume":"136","author":"A Turgut","year":"2016","unstructured":"Turgut A, Kalenderer \u00d6, Karap\u0131nar L, Kumbarac\u0131 M, Akkan HA, A\u011fu\u015f H (2016) Which factor is most important for occurrence of cutout complications in patients treated with proximal femoral nail antirotation? Retrospective analysis of 298 patients. Arch Orthop Trauma Surg 136:623\u2013630. https:\/\/doi.org\/10.1007\/s00402-016-2410-3","journal-title":"Arch Orthop Trauma Surg"},{"key":"6144_CR22","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1007\/s00264-015-2815-6","volume":"40","author":"M Gordon","year":"2016","unstructured":"Gordon M, Berntsson PO, Sj\u00f6lund E, Demir Y, Hedbeck CJ, Stark A, Sk\u00f6ldenberg O (2016) Loss of offset after Pertrochanteric hip fractures affects hip function one year after surgery with a short intramedullary nail. A prospective cohort study. Int Orthop 40:799\u2013806. https:\/\/doi.org\/10.1007\/s00264-015-2815-6","journal-title":"Int Orthop"},{"key":"6144_CR23","doi-asserted-by":"publisher","first-page":"1170","DOI":"10.1016\/j.injury.2017.03.022","volume":"48","author":"HM Ji","year":"2017","unstructured":"Ji HM, Won SH, Han J, Won YY (2017) Does femoral offset recover and affect the functional outcome of patients with displaced femoral neck fracture following hemiarthroplasty? Injury 48:1170\u20131174. https:\/\/doi.org\/10.1016\/j.injury.2017.03.022","journal-title":"Injury"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-025-06144-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-025-06144-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-025-06144-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T09:06:11Z","timestamp":1766480771000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-025-06144-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,23]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6144"],"URL":"https:\/\/doi.org\/10.1007\/s00402-025-06144-9","relation":{},"ISSN":["1434-3916"],"issn-type":[{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,23]]},"assertion":[{"value":"18 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"T.M. is the inventor of a patent related to the implant used in this study and receives royalties from HOYA Technosurgical Corporation. The patent is licensed and generates income. T.M. had no influence on the study design, data analysis, or interpretation of results. \u201dAll other authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study was approved by the Institutional Review Board of our hospital (Approval No. 2024-12-1) and was conducted in accordance with the principles of the Declaration of Helsinki and its subsequent amendments.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"15"}}