{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:00:00Z","timestamp":1786118400081,"version":"build-2736575974"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T00:00:00Z","timestamp":1785974400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T00:00:00Z","timestamp":1785974400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100012330","name":"Okayama University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012330","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Orthop Trauma Surg"],"DOI":"10.1007\/s00402-026-06464-4","type":"journal-article","created":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T15:47:37Z","timestamp":1786031257000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of iliac crest reference pin placement in total hip arthroplasty: a CT-based analysis of risk factors for cortical perforation"],"prefix":"10.1007","volume":"146","author":[{"given":"Yasutaka","family":"Masada","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4348-9806","authenticated-orcid":false,"given":"Tomonori","family":"Tetsunaga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuki","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomohiro","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryuichiro","family":"Okuda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoko","family":"Tetsunaga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuki","family":"Okazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshifumi","family":"Ozaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,6]]},"reference":[{"issue":"7","key":"6464_CR1","doi-asserted-by":"publisher","first-page":"1921","DOI":"10.1016\/j.arth.2024.12.014","volume":"40","author":"A Bensa","year":"2025","unstructured":"Bensa A, Pagliazzi G, Miele A, Schiavon G, Cuzzolin M, Filardo G (2025) Robotic-assisted total hip arthroplasty provides greater implant placement accuracy and lower complication rates, but not superior clinical results compared to the conventional manual approach: a systematic review and meta-analysis. J Arthroplasty 40(7):1921\u20131931. https:\/\/doi.org\/10.1016\/j.arth.2024.12.014","journal-title":"J Arthroplasty"},{"issue":"4","key":"6464_CR2","doi-asserted-by":"publisher","first-page":"386","DOI":"10.4103\/ortho.IJOrtho_144_17","volume":"51","author":"D Bhaskar","year":"2017","unstructured":"Bhaskar D, Rajpura A, Board T (2017) Current concepts in acetabular positioning in total hip arthroplasty. Indian J Orthop 51(4):386\u2013396. https:\/\/doi.org\/10.4103\/ortho.IJOrtho_144_17","journal-title":"Indian J Orthop"},{"issue":"5","key":"6464_CR3","doi-asserted-by":"publisher","first-page":"2073","DOI":"10.1007\/s11701-023-01623-w","volume":"17","author":"GBJ Buchan","year":"2023","unstructured":"Buchan GBJ, Hecht CJ 2nd, Liu D, Mokete L, Kendoff D, Kamath AF (2023) Improved accuracy of a novel fluoroscopy-based robotically assisted THA system compared to manual THA. J Robot Surg 17(5):2073\u20132079. https:\/\/doi.org\/10.1007\/s11701-023-01623-w","journal-title":"J Robot Surg"},{"key":"6464_CR4","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11226674","author":"EKC Bullock","year":"2022","unstructured":"Bullock EKC, Brown MJ, Clark G, Plant JGA, Blakeney WG (2022) Robotics in total hip arthroplasty: current concepts. J Clin Med. https:\/\/doi.org\/10.3390\/jcm11226674","journal-title":"J Clin Med"},{"issue":"6","key":"6464_CR5","doi-asserted-by":"publisher","first-page":"700","DOI":"10.5301\/HIP.2011.8860","volume":"21","author":"A Carcangiu","year":"2011","unstructured":"Carcangiu A, D\u2019Arrigo C, Topa D et al (2011) Reliability of cup position in navigated THA in the lateral decubitus position using the \u201cflip technique.\u201d Hip Int 21(6):700\u2013705. https:\/\/doi.org\/10.5301\/HIP.2011.8860","journal-title":"Hip Int"},{"issue":"1","key":"6464_CR6","doi-asserted-by":"publisher","first-page":"15","DOI":"10.2106\/00004623-197961010-00004","volume":"61","author":"JF Crowe","year":"1979","unstructured":"Crowe JF, Mani VJ, Ranawat CS (1979) Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am 61(1):15\u201323","journal-title":"J Bone Joint Surg Am"},{"key":"6464_CR7","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.jor.2025.07.031","volume":"69","author":"J Desrosiers","year":"2025","unstructured":"Desrosiers J, Samineni AV, Ramirez SG et al (2025) Array pin placement in robotic-assisted total hip arthroplasty: optimal trajectory to avoid neurovascular injury. J Orthop 69:278\u2013282. https:\/\/doi.org\/10.1016\/j.jor.2025.07.031","journal-title":"J Orthop"},{"issue":"9","key":"6464_CR8","doi-asserted-by":"publisher","first-page":"2842","DOI":"10.1016\/j.arth.2017.03.073","volume":"32","author":"E Kamara","year":"2017","unstructured":"Kamara E, Berliner ZP, Hepinstall MS, Cooper HJ (2017) Pin site complications associated with computer-assisted navigation in hip and knee arthroplasty. J Arthroplasty 32(9):2842\u20132846. https:\/\/doi.org\/10.1016\/j.arth.2017.03.073","journal-title":"J Arthroplasty"},{"issue":"5","key":"6464_CR9","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1016\/j.arth.2017.12.032","volume":"33","author":"AP Lambers","year":"2018","unstructured":"Lambers AP, Salim XG, Jennings R, Bucknill AT (2018) Morbidity and safety of iliac crest reference array pins in navigated total hip arthroplasty: a prospective cohort study. J Arthroplasty 33(5):1557\u20131561. https:\/\/doi.org\/10.1016\/j.arth.2017.12.032","journal-title":"J Arthroplasty"},{"issue":"9597","key":"6464_CR10","doi-asserted-by":"publisher","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","volume":"370","author":"ID Learmonth","year":"2007","unstructured":"Learmonth ID, Young C, Rorabeck C (2007) The operation of the century: total hip replacement. Lancet 370(9597):1508\u20131519. https:\/\/doi.org\/10.1016\/S0140-6736(07)60457-7","journal-title":"Lancet"},{"issue":"8","key":"6464_CR11","doi-asserted-by":"publisher","first-page":"2084","DOI":"10.1016\/j.arth.2025.01.031","volume":"40","author":"PL Lim","year":"2025","unstructured":"Lim PL, Wang KY, Sauder N, Kumar AR, Bedair HS, Melnic CM (2025) Recovery time and success: a comparative study of robotic and manual total hip arthroplasty outcomes. J Arthroplasty 40(8):2084\u20132091. https:\/\/doi.org\/10.1016\/j.arth.2025.01.031","journal-title":"J Arthroplasty"},{"issue":"1","key":"6464_CR12","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s42836-025-00299-x","volume":"7","author":"D Liu","year":"2025","unstructured":"Liu D, Kamath AF, Cholewa J, Stoenica L, Anderson MB, Lennox H (2025) Cup accuracy and early-term clinical outcomes of a novel, pinless, robotic-assisted total hip arthroplasty system: a first-in-human pilot study. Arthroplasty 7(1):20. https:\/\/doi.org\/10.1186\/s42836-025-00299-x","journal-title":"Arthroplasty"},{"issue":"5","key":"6464_CR13","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1016\/j.injury.2004.11.016","volume":"36","author":"WT Mason","year":"2005","unstructured":"Mason WT, Khan SN, James CL, Chesser TJ, Ward AJ (2005) Complications of temporary and definitive external fixation of pelvic ring injuries. Injury 36(5):599\u2013604. https:\/\/doi.org\/10.1016\/j.injury.2004.11.016","journal-title":"Injury"},{"issue":"6","key":"6464_CR14","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1530\/EOR-22-0025","volume":"7","author":"G Meermans","year":"2022","unstructured":"Meermans G, Grammatopoulos G, Innmann M, Beverland D (2022) Cup placement in primary total hip arthroplasty: how to get it right without navigation or robotics. EFORT Open Rev 7(6):365\u2013374. https:\/\/doi.org\/10.1530\/EOR-22-0025","journal-title":"EFORT Open Rev"},{"key":"6464_CR15","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.CC.24.00505","author":"S Meixner","year":"2025","unstructured":"Meixner S, Sylvestre D, Sherman R (2025) Significant arterial injury by referencing pin placement in robotic-assisted total hip arthroplasty: a case report. JBJS Case Connect. https:\/\/doi.org\/10.2106\/JBJS.CC.24.00505","journal-title":"JBJS Case Connect"},{"issue":"1","key":"6464_CR16","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1186\/s40001-023-01437-4","volume":"28","author":"F Migliorini","year":"2023","unstructured":"Migliorini F, Cuozzo F, Oliva F, Eschweiler J, Hildebrand F, Maffulli N (2023) CT-based navigation for total hip arthroplasty: a meta-analysis. Eur J Med Res 28(1):443. https:\/\/doi.org\/10.1186\/s40001-023-01437-4","journal-title":"Eur J Med Res"},{"issue":"5","key":"6464_CR17","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1177\/11207000241264256","volume":"34","author":"AS Piple","year":"2024","unstructured":"Piple AS, Wang JC, Hill W et al (2024) Postoperative outcomes and trends in computer-navigated and robotic-assisted total hip arthroplasty. Hip Int 34(5):569\u2013577. https:\/\/doi.org\/10.1177\/11207000241264256","journal-title":"Hip Int"},{"issue":"6","key":"6464_CR18","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1016\/s0090-4295(01)01355-3","volume":"58","author":"AA Stec","year":"2001","unstructured":"Stec AA, Pannu HK, Tadros YE et al (2001) Evaluation of the bony pelvis in classic bladder exstrophy by using 3D-CT: further insights. Urology 58(6):1030\u20131035. https:\/\/doi.org\/10.1016\/s0090-4295(01)01355-3","journal-title":"Urology"},{"issue":"3","key":"6464_CR19","doi-asserted-by":"publisher","first-page":"254","DOI":"10.5301\/hipint.5000345","volume":"26","author":"AM Sykes","year":"2016","unstructured":"Sykes AM, Hill JC, Orr JF et al (2016) Pelvic orientation for total hip arthroplasty in lateral decubitus: can it be accurately measured? Hip Int 26(3):254\u2013259. https:\/\/doi.org\/10.5301\/hipint.5000345","journal-title":"Hip Int"},{"issue":"7","key":"6464_CR20","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.87358","volume":"17","author":"T Tachibana","year":"2025","unstructured":"Tachibana T, Katagiri H, Watanabe T, Saito R, Jinno T (2025) Insufficiency fractures of the iliac crest following robot-assisted total hip arthroplasty: a report of two cases. Cureus 17(7):e87358. https:\/\/doi.org\/10.7759\/cureus.87358","journal-title":"Cureus"},{"key":"6464_CR21","doi-asserted-by":"publisher","DOI":"10.1016\/j.artd.2025.101769","volume":"34","author":"H Tanino","year":"2025","unstructured":"Tanino H, Mitsutake R, Ito H (2025) Effects of the flip technique on measurement accuracy of the acetabular cup position using a portable hip navigation system with patients in the lateral decubitus position. Arthroplast Today 34:101769. https:\/\/doi.org\/10.1016\/j.artd.2025.101769","journal-title":"Arthroplast Today"},{"issue":"1","key":"6464_CR22","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-021-04167-y","volume":"22","author":"H Tanino","year":"2021","unstructured":"Tanino H, Nishida Y, Mitsutake R, Ito H (2021) Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study. BMC Musculoskelet Disord 22(1):299. https:\/\/doi.org\/10.1186\/s12891-021-04167-y","journal-title":"BMC Musculoskelet Disord"}],"container-title":["Archives of Orthopaedic and Trauma Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-026-06464-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00402-026-06464-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00402-026-06464-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T15:47:38Z","timestamp":1786031258000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00402-026-06464-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,6]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6464"],"URL":"https:\/\/doi.org\/10.1007\/s00402-026-06464-4","relation":{},"ISSN":["1434-3916"],"issn-type":[{"value":"1434-3916","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,6]]},"assertion":[{"value":"22 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Review Board of Okayama University Hospital (approval number: K2511-022). The requirement for informed consent was waived due to the retrospective nature of the study and the use of anonymized data. The study was conducted in accordance with the Declaration of Helsinki.","order":2,"name":"Ethics","label":"Ethical approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The requirement for informed consent was waived by the Institutional Review Board of Okayama University Hospital due to the retrospective nature of the study and the use of anonymized data.","order":3,"name":"Ethics","label":"Consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"285"}}