{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T02:44:25Z","timestamp":1792032265024,"version":"4.4.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T00:00:00Z","timestamp":1791936000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T00:00:00Z","timestamp":1791936000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Arch Gynecol Obstet"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Point-of-care ultrasound (POCUS) in obstetrics and gynecology has evolved from a pragmatic bedside adjunct into a rapidly expanding clinical, educational and technological field. Since the publication of earlier narrative reviews, the discipline has been reshaped by handheld ultrasound systems, wireless probes, cloud-based image management, tele-ultrasound, artificial intelligence (AI) for image acquisition and interpretation, and the first specific practice guidance for POCUS in obstetrics and gynecology. This narrative review summarizes recent advances and proposes a clinically useful framework for the European ultrasound community. POCUS should be understood as a focused, problem-oriented and immediately actionable ultrasound examination performed and interpreted by the treating clinician. It is not a replacement for guideline-based screening, detailed fetal anatomy assessment, comprehensive transvaginal gynecologic imaging, Doppler surveillance or expert ultrasound. The strongest evidence supports POCUS for early pregnancy triage, confirmation of fetal viability and presentation, basic assessment of placental location and amniotic fluid, intrapartum evaluation of fetal head position and selected postpartum or gynecologic emergencies. In gynecology, POCUS can accelerate triage of acute pelvic pain, suspected ectopic pregnancy, intrauterine device position and adnexal pathology, but definitive risk stratification of complex masses remains a task for standardized specialist sonography. Technological progress has been substantial: handheld devices now provide diagnostically useful images for several focused tasks, AI-enabled blind-sweep protocols can estimate gestational age and fetal malpresentation in low-resource settings, and tele-ultrasound can extend expert support beyond tertiary centers. The next phase of OB\/GYN POCUS will depend less on device availability than on implementation: indication-specific protocols, formal training, competency assessment, documentation, image archiving, infection control, data protection, quality assurance and clear escalation rules. POCUS in obstetrics and gynecology should therefore be framed as a governed clinical pathway rather than a device-driven shortcut.<\/jats:p>","DOI":"10.1007\/s00404-026-08584-z","type":"journal-article","created":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T01:52:10Z","timestamp":1792029130000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Point-of-care ultrasound in obstetrics and gynecology: latest advancements and evolution"],"prefix":"10.1007","volume":"313","author":[{"given":"Florian","family":"Recker","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,14]]},"reference":[{"issue":"4","key":"8584_CR1","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1007\/s00404-021-05972-5","volume":"303","author":"F Recker","year":"2021","unstructured":"Recker F, Weber E, Strizek B, Gembruch U, Westerway SC, Dietrich CF (2021) Point-of-care ultrasound in obstetrics and gynecology. Arch Gynecol Obstet 303(4):871\u2013876. https:\/\/doi.org\/10.1007\/s00404-021-05972-5","journal-title":"Arch Gynecol Obstet"},{"issue":"8","key":"8584_CR2","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1056\/NEJMra0909487","volume":"364","author":"CL Moore","year":"2011","unstructured":"Moore CL, Copel JA (2011) Point-of-care ultrasonography. N Engl J Med 364(8):749\u2013757. https:\/\/doi.org\/10.1056\/NEJMra0909487","journal-title":"N Engl J Med"},{"issue":"1","key":"8584_CR3","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.ultrasmedbio.2016.06.021","volume":"43","author":"CF Dietrich","year":"2017","unstructured":"Dietrich CF, Goudie A, Chiorean L, Cui XW, Gilja OH, Dong Y et al (2017) Point of care ultrasound: a WFUMB position paper. Ultrasound Med Biol 43(1):49\u201358. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2016.06.021","journal-title":"Ultrasound Med Biol"},{"issue":"1","key":"8584_CR4","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1055\/a-0783-2303","volume":"40","author":"MB Nielsen","year":"2019","unstructured":"Nielsen MB, Cantisani V, Sidhu PS, Badea R, Batko T, Carlsen J et al (2019) The use of handheld ultrasound devices: an EFSUMB position paper. Ultraschall Med 40(1):30\u201339. https:\/\/doi.org\/10.1055\/a-0783-2303","journal-title":"Ultraschall Med"},{"key":"8584_CR5","unstructured":"International Society of Ultrasound in Obstetrics and Gynecology. ISUOG Practice Guidelines: point-of-care ultrasound in obstetrics and gynecology. Ultrasound Obstet Gynecol. 2025. Published online 2025 Nov 7."},{"key":"8584_CR6","volume-title":"WHO antenatal care recommendations for a positive pregnancy experience: ultrasound examination before 24 weeks of gestation","author":"World Health Organization","year":"2022","unstructured":"World Health Organization (2022) WHO antenatal care recommendations for a positive pregnancy experience: ultrasound examination before 24 weeks of gestation. World Health Organization, Geneva"},{"issue":"5","key":"8584_CR7","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1055\/a-1007-1581","volume":"41","author":"C K\u00e4hler","year":"2020","unstructured":"K\u00e4hler C, Schramm T, Bald R, Gembruch U, Merz E, Eichhorn KH (2020) Updated DEGUM quality requirements for the basic prenatal screening ultrasound examination (DEGUM level I) between 18+0 and 21+6 weeks of gestation. Ultraschall Med 41(5):499\u2013503. https:\/\/doi.org\/10.1055\/a-1007-1581","journal-title":"Ultraschall Med"},{"key":"8584_CR8","first-page":"607","volume":"41","author":"D Grab","year":"2020","unstructured":"Grab D, Merz E, Bald R, von Kaisenberg C, Sohn C, Tutschek B et al (2020) Quality requirements for gynecological ultrasound examinations at DEGUM level I. Ultraschall Med 41:607\u2013615","journal-title":"Ultraschall Med"},{"issue":"6","key":"8584_CR9","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1016\/j.annemergmed.2010.06.563","volume":"56","author":"JC Stein","year":"2010","unstructured":"Stein JC, Wang R, Adler N, Boscardin J, Jacoby VL, Won G et al (2010) Emergency physician ultrasonography for evaluating patients at risk for ectopic pregnancy: a meta-analysis. Ann Emerg Med 56(6):674\u2013683. https:\/\/doi.org\/10.1016\/j.annemergmed.2010.06.563","journal-title":"Ann Emerg Med"},{"key":"8584_CR10","first-page":"1538","volume":"37","author":"C Boulger","year":"2019","unstructured":"Boulger C, Adams DZ, Hooper L, Graber D, Sheele JM (2019) Pelvic point-of-care ultrasonography for the evaluation of emergency department patients with symptomatic first-trimester pregnancy: a systematic review and meta-analysis. Am J Emerg Med 37:1538\u20131545","journal-title":"Am J Emerg Med"},{"key":"8584_CR11","unstructured":"Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften S2k guideline: early pregnancy loss in the first trimester - diagnosis and treatment. AWMF registry no. 015 \u2013 076. 2025"},{"key":"8584_CR12","first-page":"1875","volume":"100","author":"JF Pedersen","year":"2021","unstructured":"Pedersen JF, Pedersen NG, M\u00f8ller S et al (2021) Handheld transabdominal ultrasound for confirmation of vital intrauterine pregnancy in the first trimester: a prospective cohort study. Acta Obstet Gynecol Scand 100:1875\u20131882","journal-title":"Acta Obstet Gynecol Scand"},{"key":"8584_CR13","doi-asserted-by":"crossref","first-page":"1468","DOI":"10.1111\/aogs.14922","volume":"103","author":"C Pl\u00f6ger","year":"2024","unstructured":"Pl\u00f6ger C, Schmidt M, Kagan KO et al (2024) Evaluation of a non-piezoelectric portable ultrasound device for focused obstetric assessment. Acta Obstet Gynecol Scand 103:1468\u20131476","journal-title":"Acta Obstet Gynecol Scand"},{"key":"8584_CR14","first-page":"2065","volume":"41","author":"CL Leggett","year":"2022","unstructured":"Leggett CL, Pang EM, Benacerraf BR et al (2022) Incorporating personal device-based point-of-care ultrasound into obstetric care: a validation study. J Ultrasound Med 41:2065\u20132074","journal-title":"J Ultrasound Med"},{"issue":"1","key":"8584_CR15","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1002\/uog.13285","volume":"44","author":"S Galjaard","year":"2014","unstructured":"Galjaard S, Baeck S, Ameye L, Bourne T, Timmerman D, Devlieger R (2014) Use of a pocket-sized ultrasound machine for routine examinations in the third trimester of pregnancy. Ultrasound Obstet Gynecol 44(1):64\u201368. https:\/\/doi.org\/10.1002\/uog.13285","journal-title":"Ultrasound Obstet Gynecol"},{"key":"8584_CR16","doi-asserted-by":"publisher","unstructured":"American College of Obstetricians and Gynecologists (2021) Fetal growth restriction: ACOG Practice Bulletin No. 227. Obstet Gynecol.;137(2):e16-e28. https:\/\/doi.org\/10.1097\/AOG.0000000000004251","DOI":"10.1097\/AOG.0000000000004251"},{"issue":"2","key":"8584_CR17","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1002\/uog.22134","volume":"56","author":"CC Lees","year":"2020","unstructured":"Lees CC, Stampalija T, Baschat A, da Silva CF, Ferrazzi E, Figueras F et al (2020) ISUOG Practice Guidelines: diagnosis and management of small-for-gestational-age fetus and fetal growth restriction. Ultrasound Obstet Gynecol 56(2):298\u2013312. https:\/\/doi.org\/10.1002\/uog.22134","journal-title":"Ultrasound Obstet Gynecol"},{"key":"8584_CR18","unstructured":"Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften (2022) S2k guideline: peripartum haemorrhage, diagnosis and therapy. AWMF registry no 015 \u2013 063"},{"issue":"1","key":"8584_CR19","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1002\/uog.19072","volume":"52","author":"T Ghi","year":"2018","unstructured":"Ghi T, Eggeb\u00f8 T, Lees C, Kalache K, Rozenberg P, Youssef A et al (2018) ISUOG practice guidelines: intrapartum ultrasound. Ultrasound Obstet Gynecol 52(1):128\u2013139. https:\/\/doi.org\/10.1002\/uog.19072","journal-title":"Ultrasound Obstet Gynecol"},{"key":"8584_CR20","doi-asserted-by":"publisher","DOI":"10.1002\/uog.70207","author":"J Song","year":"2025","unstructured":"Song J, Zhang Y, Liu Y et al (2025) Efficacy of intrapartum ultrasound in the management of maternal labor: a meta-analysis. Ultrasound Obstet Gynecol. https:\/\/doi.org\/10.1002\/uog.70207","journal-title":"Ultrasound Obstet Gynecol"},{"issue":"1","key":"8584_CR21","doi-asserted-by":"publisher","DOI":"10.1186\/s12880-020-00518-8","volume":"20","author":"M Toscano","year":"2020","unstructured":"Toscano M, Szlachetka K, Whaley N, Thornburg LL (2020) Evaluating sensitivity and specificity of handheld point-of-care ultrasound testing for gynecologic pathology: a pilot study for use in low-resource settings. BMC Med Imaging 20(1):121. https:\/\/doi.org\/10.1186\/s12880-020-00518-8","journal-title":"BMC Med Imaging"},{"key":"8584_CR22","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1097\/AOG.0000000000006009","volume":"146","author":"BA Mathyk","year":"2025","unstructured":"Mathyk BA, Cohen SL, Wright JD (2025) Handheld point-of-care ultrasonography for gynecology. Obstet Gynecol 146:1100\u20131109","journal-title":"Obstet Gynecol"},{"issue":"1","key":"8584_CR23","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1148\/radiol.2019191150","volume":"294","author":"RF Andreotti","year":"2020","unstructured":"Andreotti RF, Timmerman D, Strachowski LM, Froyman W, Benacerraf BR, Bennett GL et al (2020) O-RADS US risk stratification and management system: a consensus guideline from the ACR Ovarian-Adnexal Reporting and Data System Committee. Radiology 294(1):168\u2013185. https:\/\/doi.org\/10.1148\/radiol.2019191150","journal-title":"Radiology"},{"key":"8584_CR24","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1080\/13625187.2024.2315231","volume":"29","author":"KG Araujo","year":"2024","unstructured":"Araujo KG, Shah M, Jatlaoui TC et al (2024) Performance of a handheld point-of-care ultrasonography device for assessment of intrauterine device position. Eur J Contracept Reprod Health Care 29:118\u2013124","journal-title":"Eur J Contracept Reprod Health Care"},{"key":"8584_CR25","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1038\/s43856-022-00194-5","volume":"2","author":"RG Gomes","year":"2022","unstructured":"Gomes RG, Vwalika B, Lee C, Willis A, Sieniek M, Price JT et al (2022) AI system for fetal ultrasound in low-resource settings. Commun Med (Lond) 2:126. https:\/\/doi.org\/10.1038\/s43856-022-00194-5","journal-title":"Commun Med (Lond)"},{"key":"8584_CR26","doi-asserted-by":"publisher","first-page":"6583","DOI":"10.1038\/s41467-023-42438-5","volume":"14","author":"S Slimani","year":"2023","unstructured":"Slimani S, Ghafoorian M, Sieniek M et al (2023) End-to-end automation of fetal ultrasound biometry and amniotic fluid volume assessment. Nat Commun 14:6583. https:\/\/doi.org\/10.1038\/s41467-023-42438-5","journal-title":"Nat Commun"},{"key":"8584_CR27","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1186\/s12884-025-07796-6","volume":"25","author":"S Della Ripa","year":"2025","unstructured":"Della Ripa S, Storkey A, Papageorghiou AT et al (2025) AI-enabled obstetric point-of-care ultrasound as an emerging technology for antenatal care: a qualitative stakeholder study. BMC Pregnancy Childbirth 25:610","journal-title":"BMC Pregnancy Childbirth"},{"key":"8584_CR28","unstructured":"Butterfly Network. Butterfly Network secures first FDA clearance for blind-sweep ultrasound AI tool, marking a major stride for women's health. Burlington, MA: Butterfly Network; 2026"},{"key":"8584_CR29","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1002\/pd.6679","volume":"45","author":"N Kariman","year":"2025","unstructured":"Kariman N, Saffari M, Vlemmix F et al (2025) The potential of tele-ultrasound, handheld and self-operated ultrasound in pregnancy: a systematic review. Prenat Diagn 45:825\u2013842","journal-title":"Prenat Diagn"},{"key":"8584_CR30","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1004922","volume":"23","author":"D Le Vance","year":"2026","unstructured":"Le Vance D, Vlemmix F, Papageorghiou AT et al (2026) Tele-ultrasound in obstetrics: systematic review and meta-analysis. PLoS Med 23:e1004922","journal-title":"PLoS Med"},{"issue":"4","key":"8584_CR31","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1002\/uog.13198","volume":"43","author":"MG Tolsgaard","year":"2014","unstructured":"Tolsgaard MG, Ringsted C, Dreisler E, Klemmensen A, Loft A, Sorensen JL et al (2014) Reliable and valid assessment of ultrasound operator competence in obstetrics and gynecology. Ultrasound Obstet Gynecol 43(4):437\u2013443. https:\/\/doi.org\/10.1002\/uog.13198","journal-title":"Ultrasound Obstet Gynecol"},{"issue":"1","key":"8584_CR32","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.ajog.2017.10.016","volume":"218","author":"A Abuhamad","year":"2018","unstructured":"Abuhamad A, Minton KK, Benson CB, Chudleigh T, Crites L, Doubilet PM et al (2018) Obstetric and gynecologic ultrasound curriculum and competency assessment in residency training programs: consensus report. Am J Obstet Gynecol 218(1):29\u201367. https:\/\/doi.org\/10.1016\/j.ajog.2017.10.016","journal-title":"Am J Obstet Gynecol"},{"key":"8584_CR33","volume-title":"Ultrasound guidance for the 2024 obstetrics and gynaecology curriculum","author":"Royal College of Obstetricians and Gynaecologists","year":"2024","unstructured":"Royal College of Obstetricians and Gynaecologists (2024) Ultrasound guidance for the 2024 obstetrics and gynaecology curriculum. RCOG, London"},{"key":"8584_CR34","first-page":"1121","volume":"38","author":"EM Davis","year":"2025","unstructured":"Davis EM, Woo MY, Blakely S, Atkinson P et al (2025) Governance considerations for point-of-care ultrasound: enterprise imaging, quality assurance and program stewardship. J Digit Imaging 38:1121\u20131132","journal-title":"J Digit Imaging"},{"key":"8584_CR35","volume-title":"Position statement on the use of portable ultrasound equipment for at-home pregnancy scanning","author":"British Medical Ultrasound Society","year":"2020","unstructured":"British Medical Ultrasound Society (2020) Position statement on the use of portable ultrasound equipment for at-home pregnancy scanning. BMUS, London"}],"container-title":["Archives of Gynecology and Obstetrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00404-026-08584-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00404-026-08584-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00404-026-08584-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T01:52:45Z","timestamp":1792029165000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00404-026-08584-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,14]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["8584"],"URL":"https:\/\/doi.org\/10.1007\/s00404-026-08584-z","relation":{},"ISSN":["1432-0711"],"issn-type":[{"value":"1432-0711","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,14]]},"assertion":[{"value":"18 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The author declares that he has no competing interests. The author has received no honoraria, consultancy fees, research support or equipment from manufacturers of handheld or point-of-care ultrasound systems in relation to this work.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable for this narrative review manuscript.","order":2,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":3,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"291"}}