{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T21:40:14Z","timestamp":1790718014013,"version":"4.1.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2019,12,6]],"date-time":"2019-12-06T00:00:00Z","timestamp":1575590400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,12,6]],"date-time":"2019-12-06T00:00:00Z","timestamp":1575590400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Arch Otorhinolaryngol"],"published-print":{"date-parts":[[2020,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>The BAHA (bone-anchored hearing aid) Attract is a magnetic transcutaneous bone conduction device anchored into the temporal bone. The standard surgical technique for BAHA Attract is a multi-tools time-consuming process, which requires a large cutaneous incision. The objective of this study is to describe and test the feasibility of a minimally invasive pocket (MIP) technique for Magnet Bone Implant Hearing Aid (MBIHA) with a modified magnet of BAHA Attract without fixation and without any tissue reduction. We use a 3-cm vertical skin incision and a subperiosteal pocket.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method<\/jats:title>\n                    <jats:p>A study of 10 patients with conductive or mixed hearing loss who benefited from a MBIHA using the MIP technique is presented. The pure tone average (PTA) (dB) for air-conduction thresholds and the speech recognition threshold (SRT) (dB) in speech audiometry in quiet are calculated. The Entific Medical Systems (EMS) questionnaire and the postoperative clinical outcomes are realized.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>We found a significant improvement of 33.8\u00a0dB on average for the PTA and 44.8\u00a0dB for the SRT with MBIHA at 3\u00a0months, compared with unaided situation. No implant was removed or displaced after 2\u00a0years of follow-up. The skin condition remains intact in all the cases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The minimally subperiosteal pocket surgical technique MIP without fixation and with tissue preservation for the MBIHA is safe, rapid and effective for patients with conductive or mixed hearing loss. It opens new perspectives of development and modify conventional concept in magnetic coupling of bone-conducted device.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s00405-019-05746-5","type":"journal-article","created":{"date-parts":[[2019,12,6]],"date-time":"2019-12-06T07:08:57Z","timestamp":1575616137000},"page":"715-725","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Minimal invasive pocket technique for magnet bone implant hearing aid without fixation"],"prefix":"10.1007","volume":"277","author":[{"given":"Pierre","family":"Dolhen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel","family":"Lipski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachid","family":"Touijar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4640-9042","authenticated-orcid":false,"given":"Juliette","family":"Van Bogaert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,12,6]]},"reference":[{"issue":"2","key":"5746_CR1","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1177\/014556139407300210","volume":"73","author":"A Tjellstr\u00f6m","year":"1994","unstructured":"Tjellstr\u00f6m A, Granstr\u00f6m G (1994) Long-term follow-up with the bone-anchored hearing aid: a review of the first 100 patients between 1977 and 1985. Ear Nose Throat J 73(2):112\u2013114","journal-title":"Ear Nose Throat J"},{"key":"5746_CR2","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1177\/0003489405114S1201","volume":"195","author":"AFM Snik","year":"2005","unstructured":"Snik AFM, Mylanus EAM, Proops DW et al (2005) Consensus statements on the BAHA system: where do we stand at present? Ann Otol Rhinol Laryngol Suppl 195:2\u201312","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"issue":"Suppl 1","key":"5746_CR3","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1179\/cim.2009.10.Supplement-1.43","volume":"10","author":"MC Flynn","year":"2009","unstructured":"Flynn MC, Sadeghi A, Halvarsson G (2009) Baha solutions for patients with severe mixed hearing loss. Cochlear Implants Int 10(Suppl 1):43\u201347. https:\/\/doi.org\/10.1179\/cim.2009.10.Supplement-1.43","journal-title":"Cochlear Implants Int"},{"issue":"5","key":"5746_CR4","doi-asserted-by":"publisher","first-page":"790","DOI":"10.1097\/MAO.0b013e318291c651","volume":"34","author":"R Kiringoda","year":"2013","unstructured":"Kiringoda R, Lustig LR (2013) A meta-analysis of the complications associated with osseointegrated hearing aids. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 34(5):790\u2013794. https:\/\/doi.org\/10.1097\/MAO.0b013e318291c651","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"issue":"2","key":"5746_CR5","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/MAO.0b013e31802c74c4","volume":"28","author":"JW House","year":"2007","unstructured":"House JW, Kutz JW (2007) Bone-anchored hearing aids: incidence and management of postoperative complications. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 28(2):213\u2013217. https:\/\/doi.org\/10.1097\/MAO.0b013e31802c74c4","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"issue":"2","key":"5746_CR6","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/S0194-5998(00)70255-5","volume":"122","author":"RA Reyes","year":"2000","unstructured":"Reyes RA, Tjellstr\u00f6m A, Granstr\u00f6m G (2000) Evaluation of implant losses and skin reactions around extraoral bone-anchored implants: a 0- to 8-year follow-up. Otolaryngol Head Neck Surg Off J Am Acad Otolaryngol Head Neck Surg 122(2):272\u2013276. https:\/\/doi.org\/10.1016\/S0194-5998(00)70255-5","journal-title":"Otolaryngol Head Neck Surg Off J Am Acad Otolaryngol Head Neck Surg"},{"issue":"2","key":"5746_CR7","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1097\/MAO.0b013e318241c0bf","volume":"33","author":"CAJ Dun","year":"2012","unstructured":"Dun CAJ, Faber HT, de Wolf MJF, Mylanus EAM, Cremers CWRJ, Hol MKS (2012) Assessment of more than 1,000 implanted percutaneous bone conduction devices: skin reactions and implant survival. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 33(2):192\u2013198. https:\/\/doi.org\/10.1097\/MAO.0b013e318241c0bf","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"issue":"2","key":"5746_CR8","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1017\/S0022215108002521","volume":"123","author":"K Badran","year":"2009","unstructured":"Badran K, Arya AK, Bunstone D, Mackinnon N (2009) Long-term complications of bone-anchored hearing aids: a 14-year experience. J Laryngol Otol 123(2):170\u2013176. https:\/\/doi.org\/10.1017\/S0022215108002521","journal-title":"J Laryngol Otol"},{"issue":"5","key":"5746_CR9","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1097\/MAO.0000000000000733","volume":"36","author":"M Iseri","year":"2015","unstructured":"Iseri M, Orhan KS, Tuncer U et al (2015) transcutaneous bone-anchored hearing aids versus percutaneous ones: multicenter comparative clinical study. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 36(5):849\u2013853. https:\/\/doi.org\/10.1097\/MAO.0000000000000733","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"key":"5746_CR10","doi-asserted-by":"publisher","first-page":"416205","DOI":"10.1155\/2014\/416205","volume":"2014","author":"A Kurz","year":"2014","unstructured":"Kurz A, Flynn M, Caversaccio M, Kompis M (2014) Speech understanding with a new implant technology: a comparative study with a new nonskin penetrating Baha system. BioMed Res Int 2014:416205. https:\/\/doi.org\/10.1155\/2014\/416205","journal-title":"BioMed Res Int"},{"issue":"5","key":"5746_CR11","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1097\/MAO.0000000000000712","volume":"36","author":"R Briggs","year":"2015","unstructured":"Briggs R, Van Hasselt A, Luntz M et al (2015) Clinical performance of a new magnetic bone conduction hearing implant system: results from a prospective, multicenter, clinical investigation. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 36(5):834\u2013841. https:\/\/doi.org\/10.1097\/MAO.0000000000000712","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"key":"5746_CR12","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/s12901-016-0033-5","volume":"16","author":"PA Dimitriadis","year":"2016","unstructured":"Dimitriadis PA, Farr MR, Allam A, Ray J (2016) Three year experience with the cochlear BAHA attract implant: a systematic review of the literature. BMC Ear Nose Throat Disord 16:12. https:\/\/doi.org\/10.1186\/s12901-016-0033-5","journal-title":"BMC Ear Nose Throat Disord"},{"issue":"10","key":"5746_CR13","doi-asserted-by":"publisher","first-page":"3123","DOI":"10.1007\/s00405-016-3917-5","volume":"273","author":"W Gaw\u0119cki","year":"2016","unstructured":"Gaw\u0119cki W, Stieler OM, Balcerowiak A et al (2016) Surgical, functional and audiological evaluation of new Baha(\u00ae) Attract system implantations. Eur Arch Oto-Rhino-Laryngol Off J Eur Fed Oto-Rhino-Laryngol Soc EUFOS Affil Ger Soc Oto Rhino Laryngol Head Neck Surg 273(10):3123\u20133130. https:\/\/doi.org\/10.1007\/s00405-016-3917-5","journal-title":"Eur Arch Oto-Rhino-Laryngol Off J Eur Fed Oto-Rhino-Laryngol Soc EUFOS Affil Ger Soc Oto Rhino Laryngol Head Neck Surg"},{"issue":"1","key":"5746_CR14","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s40463-016-0181-z","volume":"46","author":"A Perenyi","year":"2017","unstructured":"Perenyi A, Bere Z, Jarabin J et al (2017) Vascular mapping of the retroauricular skin - proposal for a posterior superior surgical incision for transcutaneous bone-conduction hearing implants. J Otolaryngol Head Neck Surg J Oto Rhino Laryngol Chir Cervico Faciale 46(1):6. https:\/\/doi.org\/10.1186\/s40463-016-0181-z","journal-title":"J Otolaryngol Head Neck Surg J Oto Rhino Laryngol Chir Cervico Faciale"},{"issue":"3","key":"5746_CR15","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1097\/MAO.0000000000001327","volume":"38","author":"SY Chen","year":"2017","unstructured":"Chen SY, Mancuso D, Lalwani AK (2017) Skin necrosis after implantation with the BAHA attract: a case report and review of the literature. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 38(3):364\u2013367. https:\/\/doi.org\/10.1097\/MAO.0000000000001327","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"issue":"9","key":"5746_CR16","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1097\/MAO.0000000000001529","volume":"38","author":"PA Dimitriadis","year":"2017","unstructured":"Dimitriadis PA, Hind D, Wright K et al (2017) Single-center experience of over a hundred implantations of a transcutaneous bone conduction device. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 38(9):1301\u20131307. https:\/\/doi.org\/10.1097\/MAO.0000000000001529","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"issue":"9","key":"5746_CR17","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1097\/MAO.0000000000001518","volume":"38","author":"T Cooper","year":"2017","unstructured":"Cooper T, McDonald B, Ho A (2017) Passive transcutaneous bone conduction hearing implants: a systematic review. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 38(9):1225\u20131232. https:\/\/doi.org\/10.1097\/MAO.0000000000001518","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"key":"5746_CR18","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.ijporl.2017.01.018","volume":"94","author":"PA Dimitriadis","year":"2017","unstructured":"Dimitriadis PA, Carrick S, Ray J (2017) Intermediate outcomes of a transcutaneous bone conduction hearing device in a paediatric population. Int J Pediatr Otorhinolaryngol 94:59\u201363. https:\/\/doi.org\/10.1016\/j.ijporl.2017.01.018","journal-title":"Int J Pediatr Otorhinolaryngol"},{"issue":"3","key":"5746_CR19","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.anorl.2010.09.009","volume":"128","author":"N Saroul","year":"2011","unstructured":"Saroul N, Gilain L, Montalban A, Giraudet F, Avan P, Mom T (2011) Patient satisfaction and functional results with the bone-anchored hearing aid (BAHA). Eur Ann Otorhinolaryngol Head Neck Dis 128(3):107\u2013113. https:\/\/doi.org\/10.1016\/j.anorl.2010.09.009","journal-title":"Eur Ann Otorhinolaryngol Head Neck Dis"},{"key":"5746_CR20","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1258\/0022215021911301","volume":"28","author":"SN Dutt","year":"2002","unstructured":"Dutt SN, McDermott A-L, Jelbert A, Reid AP, Proops DW (2002) Day to day use and service-related issues with the bone-anchored hearing aid: the Entific Medical Systems questionnaire. J Laryngol Otol Suppl 28:20\u201328","journal-title":"J Laryngol Otol Suppl"},{"issue":"5","key":"5746_CR21","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1007\/s00405-013-2481-5","volume":"271","author":"M Vanlommel","year":"2014","unstructured":"Vanlommel M, Lipski S, Dolhen P (2014) Minimally invasive pocket technique for the implantation of neurelec digisonic SP cochlear implant. Eur Arch Oto-Rhino Laryngol Off J Eur Fed Oto Rhino Laryngol Soc EUFOS Affil Ger Soc Oto Rhino Laryngol Head Neck Surg 271(5):913\u2013918. https:\/\/doi.org\/10.1007\/s00405-013-2481-5","journal-title":"Eur Arch Oto-Rhino Laryngol Off J Eur Fed Oto Rhino Laryngol Soc EUFOS Affil Ger Soc Oto Rhino Laryngol Head Neck Surg"},{"issue":"7","key":"5746_CR22","doi-asserted-by":"publisher","first-page":"1674","DOI":"10.1002\/lary.24426","volume":"124","author":"D Jethanamest","year":"2014","unstructured":"Jethanamest D, Channer GA, Moss WJ, Lustig LR, Telischi FF (2014) Cochlear implant fixation using a subperiosteal tight pocket without either suture or bone-recess technique. Laryngoscope 124(7):1674\u20131677. https:\/\/doi.org\/10.1002\/lary.24426","journal-title":"Laryngoscope"},{"issue":"8","key":"5746_CR23","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1177\/000348941011900801","volume":"119","author":"N Guevara","year":"2010","unstructured":"Guevara N, Sterkers O, B\u00e9b\u00e9ar J-P et al (2010) Multicenter evaluation of the digisonic SP cochlear implant fixation system with titanium screws in 156 patients. Ann Otol Rhinol Laryngol 119(8):501\u2013505. https:\/\/doi.org\/10.1177\/000348941011900801","journal-title":"Ann Otol Rhinol Laryngol"},{"issue":"6","key":"5746_CR24","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1097\/MAO.0b013e3182255949","volume":"32","author":"Y G\u00fcldiken","year":"2011","unstructured":"G\u00fcldiken Y, Orhan KS, Yi\u011fit O et al (2011) Subperiosteal temporal pocket versus standard technique in cochlear implantation: a comparative clinical study. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 32(6):987\u2013991. https:\/\/doi.org\/10.1097\/MAO.0b013e3182255949","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"issue":"7","key":"5746_CR25","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1097\/MAO.0b013e3181b4e904","volume":"30","author":"TJ Balkany","year":"2009","unstructured":"Balkany TJ, Whitley M, Shapira Y et al (2009) The temporalis pocket technique for cochlear implantation: an anatomic and clinical study. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 30(7):903\u2013907. https:\/\/doi.org\/10.1097\/MAO.0b013e3181b4e904","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"issue":"12","key":"5746_CR26","doi-asserted-by":"publisher","first-page":"4175","DOI":"10.1007\/s00405-016-4107-1","volume":"273","author":"W Gaw\u0119cki","year":"2016","unstructured":"Gaw\u0119cki W, Karlik M, Borucki \u0141, Szyfter-Harris J, Wr\u00f3bel M (2016) Skin flap complications after cochlear implantations. Eur Arch Oto Rhino Laryngol Off J Eur Fed Oto Rhino Laryngol Soc EUFOS Affil Ger Soc Oto-Rhino-Laryngol Head Neck Surg 273(12):4175\u20134183. https:\/\/doi.org\/10.1007\/s00405-016-4107-1","journal-title":"Eur Arch Oto Rhino Laryngol Off J Eur Fed Oto Rhino Laryngol Soc EUFOS Affil Ger Soc Oto-Rhino-Laryngol Head Neck Surg"},{"issue":"2","key":"5746_CR27","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1007\/s00405-016-4305-x","volume":"274","author":"A Caruso","year":"2017","unstructured":"Caruso A, Giannuzzi AL, Sozzi V, Sanna M (2017) Bone anchored hearing implants without skin thinning: the Gruppo Otologico surgical and audiological experience. Eur Arch Otorhinolaryngol 274(2):695\u2013700. https:\/\/doi.org\/10.1007\/s00405-016-4305-x","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"1","key":"5746_CR28","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/MAO.0000000000001258","volume":"38","author":"T Dumon","year":"2017","unstructured":"Dumon T, Wegner I, Sperling N, Grolman W (2017) Implantation of bone-anchored hearing devices through a minimal skin punch incision versus the epidermal flap technique. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 38(1):89\u201396. https:\/\/doi.org\/10.1097\/MAO.0000000000001258","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"},{"issue":"9","key":"5746_CR29","doi-asserted-by":"publisher","first-page":"1525","DOI":"10.1097\/MAO.0000000000000842","volume":"36","author":"HRF Powell","year":"2015","unstructured":"Powell HRF, Rolfe AM, Birman CS (2015) A comparative study of audiologic outcomes for two transcutaneous bone-anchored hearing devices. Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol 36(9):1525\u20131531. https:\/\/doi.org\/10.1097\/MAO.0000000000000842","journal-title":"Otol Neurotol Off Publ Am Otol Soc Am Neurotol Soc Eur Acad Otol Neurotol"}],"container-title":["European Archives of Oto-Rhino-Laryngology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-019-05746-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00405-019-05746-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-019-05746-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,12,4]],"date-time":"2020-12-04T19:24:48Z","timestamp":1607109888000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00405-019-05746-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,6]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["5746"],"URL":"https:\/\/doi.org\/10.1007\/s00405-019-05746-5","relation":{},"ISSN":["0937-4477","1434-4726"],"issn-type":[{"value":"0937-4477","type":"print"},{"value":"1434-4726","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,6]]},"assertion":[{"value":"21 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 November 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee (include name of committee\u2009+\u2009reference number) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. This clinical study was accepted by the Hospital-Faculty Ethics Committee of Tivoli Hospital (Ref: B096201734622).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}