{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T04:45:47Z","timestamp":1780116347025,"version":"3.54.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,3,6]],"date-time":"2021-03-06T00:00:00Z","timestamp":1614988800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,3,6]],"date-time":"2021-03-06T00:00:00Z","timestamp":1614988800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Projekt DEAL"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Arch Otorhinolaryngol"],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Aim of the study was to evaluate the surgical, clinical and audiological outcome of 32 implantations of the Bonebridge, a semi-implantable transcutaneous active bone conduction implant.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In a retrospective cohort study, we analyzed data for 32 implantations in 31 patients (one bilateral case; seven age\u2009&lt;\u200916\u00a0years) with conductive or mixed hearing loss, malformations, after multiple ear surgery, or with single-sided deafness as contralateral routing of signal (CROS).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Four implantations were done as CROS. Five cases were simultaneously planned with ear\u00a0prosthesis anchors, and 23 implantations (72%) were planned through three-dimensional (3D) \u201cvirtual surgery.\u201d In all 3D-planned cases, the implant could be placed as expected. For implant-related complications, rates were 12.5% for minor and 3.1% for major complications. Implantation significantly improved mean sound field thresholds from a preoperative 60\u00a0dB HL (SD\u00a012) to 33\u00a0dB HL (SD 6) at 3 postoperative months and 34\u00a0dB HL (SD 6) at\u2009&gt;\u200911 postoperative months (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001). Word recognition score in quiet at 65\u00a0dB SPL improved from 11% (SD 20) preoperatively to 74%\u00a0(SD 19) at 3\u00a0months and 83%\u00a0(SD\u00a015) at\u2009&gt;\u200911\u00a0months (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001). The speech reception threshold in noise improved from \u2212\u20091.01\u00a0dB\u00a0unaided to \u2212\u20092.69\u00a0dB\u00a0best-aided (<jats:italic>p<\/jats:italic>\u2009=\u20090.0018).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>We found a clinically relevant audiological benefit with Bonebridge. To overcome anatomical challenges, we recommend preoperative 3D planning in small and hypoplastic mastoids, children, ear malformation, and simultaneous implantation of ear prosthesis anchors and after multiple ear surgery.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00405-021-06626-7","type":"journal-article","created":{"date-parts":[[2021,3,6]],"date-time":"2021-03-06T03:02:58Z","timestamp":1614999778000},"page":"101-113","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Clinical and functional results after implantation of the bonebridge, a semi-implantable, active transcutaneous bone conduction device, in children and adults"],"prefix":"10.1007","volume":"279","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5861-1312","authenticated-orcid":false,"given":"Ingmar","family":"Seiwerth","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Fr\u00f6hlich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Schilde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerrit","family":"G\u00f6tze","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan K.","family":"Plontke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Torsten","family":"Rahne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,3,6]]},"reference":[{"issue":"2","key":"6626_CR1","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1111\/coa.12484","volume":"41","author":"GM Sprinzl","year":"2016","unstructured":"Sprinzl GM, Wolf-Magele A (2016) The Bonebridge Bone Conduction Hearing Implant: indication criteria, surgery and a systematic review of the literature. Clin Otolaryngol 41(2):131\u2013143. https:\/\/doi.org\/10.1111\/coa.12484","journal-title":"Clin Otolaryngol"},{"issue":"3\u20134","key":"6626_CR2","doi-asserted-by":"publisher","first-page":"229","DOI":"10.3109\/00016488509104785","volume":"100","author":"B Hakansson","year":"1985","unstructured":"Hakansson B, Tjellstrom A, Rosenhall U, Carlsson P (1985) The bone-anchored hearing aid. Principal design and a psychoacoustical evaluation. Acta Otolaryngol 100(3\u20134):229\u2013239","journal-title":"Acta Otolaryngol"},{"issue":"2","key":"6626_CR3","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1017\/S0022215109991708","volume":"124","author":"JC Hobson","year":"2010","unstructured":"Hobson JC, Roper AJ, Andrew R, Rothera MP, Hill P, Green KM (2010) Complications of bone-anchored hearing aid implantation. J Laryngol Otol 124(2):132\u2013136. https:\/\/doi.org\/10.1017\/S0022215109991708","journal-title":"J Laryngol Otol"},{"issue":"6","key":"6626_CR4","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1097\/MAO.0000000000001010","volume":"37","author":"T Gerdes","year":"2016","unstructured":"Gerdes T, Salcher RB, Schwab B, Lenarz T, Maier H (2016) Comparison of Audiological Results Between a Transcutaneous and a Percutaneous Bone Conduction Instrument in Conductive Hearing Loss. Otol Neurotol 37(6):685\u2013691. https:\/\/doi.org\/10.1097\/MAO.0000000000001010","journal-title":"Otol Neurotol"},{"issue":"4","key":"6626_CR5","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1017\/S0022215119000501","volume":"133","author":"C Carnevale","year":"2019","unstructured":"Carnevale C, Tomas-Barberan M, Til-Perez G, Sarria-Echegaray P (2019) The Bonebridge active bone conduction system: a fast and safe technique for a middle fossa approach. J Laryngol Otol 133(4):344\u2013347. https:\/\/doi.org\/10.1017\/S0022215119000501","journal-title":"J Laryngol Otol"},{"issue":"7","key":"6626_CR6","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1097\/MAO.0000000000000405","volume":"35","author":"SK Plontke","year":"2014","unstructured":"Plontke SK, Radetzki F, Seiwerth I, Herzog M, Brandt S, Delank KS, Rahne T (2014) Individual computer-assisted 3D planning for surgical placement of a new bone conduction hearing device. Otol Neurotol 35(7):1251\u20131257. https:\/\/doi.org\/10.1097\/MAO.0000000000000405","journal-title":"Otol Neurotol"},{"issue":"6","key":"6626_CR7","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1097\/MAO.0b013e31828bb541","volume":"34","author":"G Sprinzl","year":"2013","unstructured":"Sprinzl G, Lenarz T, Ernst A, Hagen R, Wolf-Magele A, Mojallal H, Todt I, Mlynski R, Wolframm MD (2013) First European multicenter results with a new transcutaneous bone conduction hearing implant system: short-term safety and efficacy. Otol Neurotol 34(6):1076\u20131083. https:\/\/doi.org\/10.1097\/MAO.0b013e31828bb541","journal-title":"Otol Neurotol"},{"issue":"Suppl 2","key":"6626_CR8","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s00106-018-0533-2","volume":"66","author":"D Beutner","year":"2018","unstructured":"Beutner D, Delb W, Frenzel H, Hoppe U, Huttenbrink KB, Mlynski R, Limberger A, Schonweiler R, Schwab B, Todt I, Walger M, Wesarg T, Zahnert T, Zeh R, Adano D, Dga DC, Implantat Gesellschaft D, Dgpp, (2018) Guideline \u201cImplantable hearing aids\u201d-short version\u202f: German S2k guideline of the Working Group of German-Speaking Audiologists, Neurootologists and Otologists (ADANO), of the German Society of Oto-Rhino-Laryngology, Head and Neck Surgery (DGHNO) in collaboration with the German Society of Audiology (DGA), the German Society of Phoniatrics and Pediatric Audiology (DGPP), and patient representatives. HNO 66(Suppl 2):71\u201376. https:\/\/doi.org\/10.1007\/s00106-018-0533-2","journal-title":"HNO"},{"issue":"10","key":"6626_CR9","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.3109\/00016489.2013.799293","volume":"133","author":"M Barbara","year":"2013","unstructured":"Barbara M, Perotti M, Gioia B, Volpini L, Monini S (2013) Transcutaneous bone-conduction hearing device: audiological and surgical aspects in a first series of patients with mixed hearing loss. Acta Otolaryngol 133(10):1058\u20131064. https:\/\/doi.org\/10.3109\/00016489.2013.799293","journal-title":"Acta Otolaryngol"},{"issue":"2","key":"6626_CR10","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.otorri.2018.02.006","volume":"70","author":"C Carnevale","year":"2019","unstructured":"Carnevale C, Til-Perez G, Arancibia-Tagle DJ, Tomas-Barberan MD, Sarria-Echegaray PL (2019) Hearing outcomes of the active bone conduction system Bonebridge((R)) in conductive or mixed hearing loss. Acta Otorrinolaringol Esp 70(2):80\u201388. https:\/\/doi.org\/10.1016\/j.otorri.2018.02.006","journal-title":"Acta Otorrinolaringol Esp"},{"issue":"3","key":"6626_CR11","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1097\/MAO.0000000000000969","volume":"37","author":"KE Eberhard","year":"2016","unstructured":"Eberhard KE, Olsen SO, Miyazaki H, Bille M, Caye-Thomasen P (2016) Objective and subjective outcome of a new transcutaneous bone conduction hearing device: half-year follow-up of the first 12 nordic implantations. Otol Neurotol 37(3):267\u2013275. https:\/\/doi.org\/10.1097\/MAO.0000000000000969","journal-title":"Otol Neurotol"},{"issue":"2","key":"6626_CR12","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1097\/MAO.0000000000000208","volume":"35","author":"F Ihler","year":"2014","unstructured":"Ihler F, Volbers L, Blum J, Matthias C, Canis M (2014) Preliminary functional results and quality of life after implantation of a new bone conduction hearing device in patients with conductive and mixed hearing loss. Otol Neurotol 35(2):211\u2013215. https:\/\/doi.org\/10.1097\/MAO.0000000000000208","journal-title":"Otol Neurotol"},{"issue":"2","key":"6626_CR13","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1097\/MAO.0000000000000253","volume":"35","author":"M Manrique","year":"2014","unstructured":"Manrique M, Sanhueza I, Manrique R, de Abajo J (2014) A new bone conduction implant: surgical technique and results. Otol Neurotol 35(2):216\u2013220. https:\/\/doi.org\/10.1097\/MAO.0000000000000253","journal-title":"Otol Neurotol"},{"issue":"5","key":"6626_CR14","doi-asserted-by":"publisher","first-page":"2107","DOI":"10.1007\/s00405-016-4434-2","volume":"274","author":"R Weiss","year":"2017","unstructured":"Weiss R, Leinung M, Baumann U, Weissgerber T, Rader T, Stover T (2017) Improvement of speech perception in quiet and in noise without decreasing localization abilities with the bone conduction device Bonebridge. Eur Arch Otorhinolaryngol 274(5):2107\u20132115. https:\/\/doi.org\/10.1007\/s00405-016-4434-2","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"6","key":"6626_CR15","doi-asserted-by":"publisher","first-page":"556","DOI":"10.3109\/00016489.2016.1143119","volume":"136","author":"ME Zernotti","year":"2016","unstructured":"Zernotti ME, Di Gregorio MF, Galeazzi P, Tabernero P (2016) Comparative outcomes of active and passive hearing devices by transcutaneous bone conduction. Acta Otolaryngol 136(6):556\u2013558. https:\/\/doi.org\/10.3109\/00016489.2016.1143119","journal-title":"Acta Otolaryngol"},{"issue":"6","key":"6626_CR16","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1097\/MAO.0000000000001038","volume":"37","author":"WD Baumgartner","year":"2016","unstructured":"Baumgartner WD, Hamzavi JS, Boheim K, Wolf-Magele A, Schlogel M, Riechelmann H, Zorowka P, Koci V, Keck T, Potzinger P, Sprinzl G (2016) A new transcutaneous bone conduction hearing implant: short-term safety and efficacy in children. Otol Neurotol 37(6):713\u2013720. https:\/\/doi.org\/10.1097\/MAO.0000000000001038","journal-title":"Otol Neurotol"},{"issue":"12","key":"6626_CR17","doi-asserted-by":"publisher","first-page":"2802","DOI":"10.1002\/lary.24832","volume":"124","author":"D Riss","year":"2014","unstructured":"Riss D, Arnoldner C, Baumgartner WD, Blineder M, Flak S, Bachner A, Gstoettner W, Hamzavi JS (2014) Indication criteria and outcomes with the Bonebridge transcutaneous bone-conduction implant. Laryngoscope 124(12):2802\u20132806. https:\/\/doi.org\/10.1002\/lary.24832","journal-title":"Laryngoscope"},{"issue":"5","key":"6626_CR18","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1111\/coa.12793","volume":"42","author":"E Vyskocil","year":"2017","unstructured":"Vyskocil E, Riss D, Arnoldner C, Hamzavi JS, Liepins R, Kaider A, Honeder C, Fumicz J, Gstoettner W, Baumgartner WD (2017) Dura and sinus compression with a transcutaneous bone conduction device\u2014hearing outcomes and safety in 38 patients. Clin Otolaryngol 42(5):1033\u20131038. https:\/\/doi.org\/10.1111\/coa.12793","journal-title":"Clin Otolaryngol"},{"issue":"9","key":"6626_CR19","doi-asserted-by":"publisher","first-page":"e0221484","DOI":"10.1371\/journal.pone.0221484","volume":"14","author":"A Magele","year":"2019","unstructured":"Magele A, Schoerg P, Stanek B, Gradl B, Sprinzl GM (2019) Active transcutaneous bone conduction hearing implants: systematic review and meta-analysis. PLoS ONE 14(9):e0221484. https:\/\/doi.org\/10.1371\/journal.pone.0221484","journal-title":"PLoS ONE"},{"issue":"5","key":"6626_CR20","doi-asserted-by":"publisher","first-page":"e482","DOI":"10.1097\/MAO.0000000000002201","volume":"40","author":"L Wagner","year":"2019","unstructured":"Wagner L, Honig E, Frohlich L, Plontke S, Rahne T (2019) Optimal retention force of audio processor magnets. Otol Neurotol 40(5):e482\u2013e487. https:\/\/doi.org\/10.1097\/MAO.0000000000002201","journal-title":"Otol Neurotol"},{"issue":"6","key":"6626_CR21","doi-asserted-by":"publisher","first-page":"360","DOI":"10.3109\/14992027.2014.880813","volume":"53","author":"S Reinfeldt","year":"2014","unstructured":"Reinfeldt S, Hakansson B, Taghavi H, Eeg-Olofsson M (2014) Bone conduction hearing sensitivity in normal-hearing subjects: transcutaneous stimulation at BAHA vs BCI position. Int J Audiol 53(6):360\u2013369. https:\/\/doi.org\/10.3109\/14992027.2014.880813","journal-title":"Int J Audiol"},{"issue":"7","key":"6626_CR22","doi-asserted-by":"publisher","first-page":"1651","DOI":"10.1007\/s00405-014-2976-8","volume":"272","author":"W Wimmer","year":"2015","unstructured":"Wimmer W, Gerber N, Guignard J, Dubach P, Kompis M, Weber S, Caversaccio M (2015) Topographic bone thickness maps for Bonebridge implantations. Eur Arch Otorhinolaryngol 272(7):1651\u20131658. https:\/\/doi.org\/10.1007\/s00405-014-2976-8","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"12","key":"6626_CR23","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1007\/s00106-012-2652-5","volume":"61","author":"M Canis","year":"2013","unstructured":"Canis M, Ihler F, Blum J, Matthias C (2013) CT-assisted navigation for retrosigmoidal implantation of the Bonebridge. HNO 61(12):1038\u20131044. https:\/\/doi.org\/10.1007\/s00106-012-2652-5","journal-title":"HNO"},{"key":"6626_CR24","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.ijscr.2016.11.057","volume":"30","author":"TH Kong","year":"2017","unstructured":"Kong TH, Park YA, Seo YJ (2017) Image-guided implantation of the Bonebridge with a surgical navigation: a feasibility study. Int J Surg Case Rep 30:112\u2013117. https:\/\/doi.org\/10.1016\/j.ijscr.2016.11.057","journal-title":"Int J Surg Case Rep"},{"issue":"6","key":"6626_CR25","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1007\/s00330-015-3983-x","volume":"26","author":"EK Law","year":"2016","unstructured":"Law EK, Bhatia KS, Tsang WS, Tong MC, Shi L (2016) CT pre-operative planning of a new semi-implantable bone conduction hearing device. Eur Radiol 26(6):1686\u20131695. https:\/\/doi.org\/10.1007\/s00330-015-3983-x","journal-title":"Eur Radiol"},{"issue":"4","key":"6626_CR26","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1097\/MAO.0000000000001734","volume":"39","author":"H Arnold","year":"2018","unstructured":"Arnold H, Schulze M, Wolpert S, Hirt B, Tropitzsch A, Zimmermann R, Radeloff A, Lowenheim H, Reimann K (2018) Positioning a novel transcutaneous bone conduction hearing implant: a systematic anatomical and radiological study to standardize the retrosigmoid approach, correlating navigation-guided, and landmark-based surgery. Otol Neurotol 39(4):458\u2013466. https:\/\/doi.org\/10.1097\/MAO.0000000000001734","journal-title":"Otol Neurotol"},{"issue":"5","key":"6626_CR27","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1007\/s11548-013-0973-9","volume":"9","author":"B Cho","year":"2014","unstructured":"Cho B, Matsumoto N, Mori M, Komune S, Hashizume M (2014) Image-guided placement of the bonebridge without surgical navigation equipment. Int J Comput Assist Radiol Surg 9(5):845\u2013855. https:\/\/doi.org\/10.1007\/s11548-013-0973-9","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"12","key":"6626_CR28","doi-asserted-by":"publisher","first-page":"3669","DOI":"10.1007\/s00405-014-3452-1","volume":"272","author":"N Matsumoto","year":"2015","unstructured":"Matsumoto N, Takumi Y, Cho B, Mori K, Usami S, Yamashita M, Hashizume M, Komune S (2015) Template-guided implantation of the Bonebridge: clinical experience. Eur Arch Otorhinolaryngol 272(12):3669\u20133675. https:\/\/doi.org\/10.1007\/s00405-014-3452-1","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"10","key":"6626_CR29","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.3109\/00016489.2014.900703","volume":"134","author":"Y Takumi","year":"2014","unstructured":"Takumi Y, Matsumoto N, Cho B, Ono H, Mori K, Tsukada K, Ichinose A, Yoshimura H, Iwasaki S, Komune S, Usami S (2014) A clinical experience of \u201cSTAMP\u201d plate-guided Bonebridge implantation. Acta Otolaryngol 134(10):1042\u20131046. https:\/\/doi.org\/10.3109\/00016489.2014.900703","journal-title":"Acta Otolaryngol"},{"issue":"12","key":"6626_CR30","doi-asserted-by":"publisher","first-page":"4103","DOI":"10.1007\/s00405-016-3972-y","volume":"273","author":"L Lassaletta","year":"2016","unstructured":"Lassaletta L, Calvino M, Zernotti M, Gavilan J (2016) Postoperative pain in patients undergoing a transcutaneous active bone conduction implant (Bonebridge). Eur Arch Otorhinolaryngol 273(12):4103\u20134110. https:\/\/doi.org\/10.1007\/s00405-016-3972-y","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"7","key":"6626_CR31","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1097\/MAO.0000000000001834","volume":"39","author":"T Rader","year":"2018","unstructured":"Rader T, Stover T, Lenarz T, Maier H, Zahnert T, Beleites T, Hagen R, Mlynski R, Baumgartner WD (2018) Retrospective analysis of hearing-impaired adult patients treated with an active transcutaneous bone conduction implant. Otol Neurotol 39(7):874\u2013881. https:\/\/doi.org\/10.1097\/MAO.0000000000001834","journal-title":"Otol Neurotol"},{"issue":"10","key":"6626_CR32","doi-asserted-by":"publisher","first-page":"736","DOI":"10.3109\/14992027.2015.1051665","volume":"54","author":"H Taghavi","year":"2015","unstructured":"Taghavi H, Hakansson B, Reinfeldt S, Eeg-Olofsson M, Jansson KJ, Hakansson E, Nasri B (2015) Technical design of a new bone conduction implant (BCI) system. Int J Audiol 54(10):736\u2013744. https:\/\/doi.org\/10.3109\/14992027.2015.1051665","journal-title":"Int J Audiol"},{"issue":"1","key":"6626_CR33","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1097\/MAO.0000000000000881","volume":"37","author":"T Rahne","year":"2016","unstructured":"Rahne T, Schilde S, Seiwerth I, Radetzki F, Stoevesandt D, Plontke SK (2016) Mastoid dimensions in children and young adults: consequences for the geometry of transcutaneous bone-conduction implants. Otol Neurotol 37(1):57\u201361. https:\/\/doi.org\/10.1097\/MAO.0000000000000881","journal-title":"Otol Neurotol"},{"key":"6626_CR34","doi-asserted-by":"crossref","unstructured":"Wenzel C, Schilde S, Plontke SK, Rahne T (2020) Changes in Bone Conduction Implant Geometry Improve the Bone Fit in Mastoids of Children and Young Adults. Otol Neurotol in press","DOI":"10.1097\/MAO.0000000000002798"},{"issue":"Suppl 2","key":"6626_CR35","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1007\/s00106-020-00877-2","volume":"68","author":"SK Plontke","year":"2020","unstructured":"Plontke SK, Gotze G, Wenzel C, Rahne T, Mlynski R (2020) Implantation of a new active bone conduction hearing device with optimized geometry. HNO 68(Suppl 2):106\u2013115. https:\/\/doi.org\/10.1007\/s00106-020-00877-2","journal-title":"HNO"},{"key":"6626_CR36","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000002919","author":"T Rahne","year":"2020","unstructured":"Rahne T, Svensson S, Lagerkvist H, Holmberg M, Plontke SK, Wenzel C (2020) Assessment of temporal bone thickness for implantation of a new active bone-conduction transducer. Otol Neurotol. https:\/\/doi.org\/10.1097\/MAO.0000000000002919","journal-title":"Otol Neurotol"}],"container-title":["European Archives of Oto-Rhino-Laryngology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-021-06626-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00405-021-06626-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-021-06626-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,6]],"date-time":"2022-01-06T10:05:11Z","timestamp":1641463511000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00405-021-06626-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,6]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,1]]}},"alternative-id":["6626"],"URL":"https:\/\/doi.org\/10.1007\/s00405-021-06626-7","relation":{},"ISSN":["0937-4477","1434-4726"],"issn-type":[{"value":"0937-4477","type":"print"},{"value":"1434-4726","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,6]]},"assertion":[{"value":"29 August 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 January 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 March 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest related to the submitted work. Outside the submitted work the following financial activities are declared for all authors (initials):","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study was conducted with the approval of the local ethics committee (No. 2019\u2013123) and in accordance with the Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}