{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:07:15Z","timestamp":1740107235140,"version":"3.37.3"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2021,7,15]],"date-time":"2021-07-15T00:00:00Z","timestamp":1626307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,7,15]],"date-time":"2021-07-15T00:00:00Z","timestamp":1626307200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Arch Otorhinolaryngol"],"published-print":{"date-parts":[[2021,11]]},"DOI":"10.1007\/s00405-021-06981-5","type":"journal-article","created":{"date-parts":[[2021,7,15]],"date-time":"2021-07-15T13:02:59Z","timestamp":1626354179000},"page":"4403-4409","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Simulated laryngoscopy with supraglottic high-pressure source ventilation: an in vitro study of tracheal airflow to determine optimal positioning of laryngoscope and jet ventilation cannula"],"prefix":"10.1007","volume":"278","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2047-1788","authenticated-orcid":false,"given":"Carys R.","family":"Whittet","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali","family":"Al-Hussaini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Hadfield","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Owens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,7,15]]},"reference":[{"issue":"11","key":"6981_CR1","doi-asserted-by":"publisher","first-page":"1326","DOI":"10.1288\/00005537-198711000-00015","volume":"97","author":"DM Crockett","year":"1987","unstructured":"Crockett DM, Scamman FL, McCabe BF, Lusk RP, Gray SD (1987) Venturi jet ventilation for microlaryngoscopy: technique, complications, pitfalls. Laryngoscope 97(11):1326\u20131330. https:\/\/doi.org\/10.1288\/00005537-198711000-00015","journal-title":"Laryngoscope"},{"issue":"8","key":"6981_CR2","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1007\/978-88-470-2203-4_27","volume":"59","author":"U Borg","year":"1980","unstructured":"Borg U, Eriksson I, Sjostrand U (1980) High-frequency positive-pressure ventilation (HFPPV): a review based upon its use during bronchoscopy and for laryngoscopy and microlaryngeal surgery under general anesthesia. Anesth Analg 59(8):594\u2013603. https:\/\/doi.org\/10.1007\/978-88-470-2203-4_27","journal-title":"Anesth Analg"},{"key":"6981_CR3","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1097\/00000542-198002000-00019","volume":"52","author":"M Babinski","year":"1980","unstructured":"Babinski M, Brian Smith R, Klain M (1980) High Frequency jet ventilation for laryngoscopy. Anesthesiology 52:178\u2013180","journal-title":"Anesthesiology"},{"issue":"7","key":"6981_CR4","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1093\/bjaed\/mkx004","volume":"17","author":"KL Pearson","year":"2017","unstructured":"Pearson KL, McGuire BE (2017) Anaesthesia for laryngotracheal surgery including tubeless field techniques. BJA Education 17(7):242\u2013248. https:\/\/doi.org\/10.1093\/bjaed\/mkx004","journal-title":"BJA Education"},{"issue":"1","key":"6981_CR5","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1093\/bjaceaccp\/mkl061","volume":"7","author":"E Evans","year":"2007","unstructured":"Evans E, Biro P, Bedforth N (2007) Jet ventilation. Continuing Educ Anaesth Critical Care Pain 7(1):2\u20135. https:\/\/doi.org\/10.1093\/bjaceaccp\/mkl061","journal-title":"Continuing Educ Anaesth Critical Care Pain"},{"issue":"2","key":"6981_CR6","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1093\/bja\/aen139","volume":"101","author":"TM Cook","year":"2008","unstructured":"Cook TM, Alexander R (2008) Major complications during anaesthesia for elective laryngeal surgery in the UK: a national survey of the use of high-pressure source ventilation. B J Anaesth 101(2):266\u2013272. https:\/\/doi.org\/10.1093\/bja\/aen139","journal-title":"B J Anaesth"},{"issue":"6","key":"6981_CR7","doi-asserted-by":"publisher","first-page":"940","DOI":"10.1093\/bja\/83.6.940","volume":"83","author":"G Ihra","year":"1999","unstructured":"Ihra G, Hieber C, Schabernig P et al (1999) Supralaryngeal tubeless combined high-frequency jet ventilation for laser surgery of the larynx and trachea. Br J Anaesth 83(6):940\u2013942. https:\/\/doi.org\/10.1093\/bja\/83.6.940","journal-title":"Br J Anaesth"},{"key":"6981_CR8","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1097\/00000542-200601000-00010","volume":"104","author":"Y Jacquet","year":"2006","unstructured":"Jacquet Y, Monnier P, Van Melle G et al (2006) Complications of different ventilation strategies in endoscopic laryngeal surgery. A 10-year review. Anaesthesiology 104:52\u201359. https:\/\/doi.org\/10.1097\/00000542-200601000-00010","journal-title":"Anaesthesiology"},{"issue":"5","key":"6981_CR9","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1093\/bja\/ael074","volume":"96","author":"A Rezaie-Majd","year":"2006","unstructured":"Rezaie-Majd A, Bigenzahn W, Denk DM, Burian M, Kornfehl J, Grasl MCh, Ihra G, Aloy A (2006) Superimposed high-frequency jet ventilation (SHFJV) for endoscopic laryngotracheal surgery in more than 1500 patients. Br J Anaesth 96(5):650\u2013659. https:\/\/doi.org\/10.1093\/bja\/ael074","journal-title":"Br J Anaesth"},{"issue":"6","key":"6981_CR10","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1093\/bja\/aem312","volume":"99","author":"PW Buczkowski","year":"2007","unstructured":"Buczkowski PW, Fombon FN, Lin ES, Russell WC, Thompson JP (2007) Air entrainment during high-frequency jet ventilation in a model of upper tracheal stenosis. Br J Anaesth 99(6):891\u2013897. https:\/\/doi.org\/10.1093\/bja\/aem312","journal-title":"Br J Anaesth"}],"container-title":["European Archives of Oto-Rhino-Laryngology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-021-06981-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00405-021-06981-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-021-06981-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,1]],"date-time":"2021-10-01T05:32:57Z","timestamp":1633066377000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00405-021-06981-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,15]]},"references-count":10,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["6981"],"URL":"https:\/\/doi.org\/10.1007\/s00405-021-06981-5","relation":{},"ISSN":["0937-4477","1434-4726"],"issn-type":[{"type":"print","value":"0937-4477"},{"type":"electronic","value":"1434-4726"}],"subject":[],"published":{"date-parts":[[2021,7,15]]},"assertion":[{"value":"26 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Not applicable<b>.<\/b>","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Not applicable.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}