{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T15:26:01Z","timestamp":1789140361354,"version":"build-2803163510"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T00:00:00Z","timestamp":1638835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T00:00:00Z","timestamp":1638835200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Martin-Luther-Universit\u00e4t Halle-Wittenberg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Arch Otorhinolaryngol"],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>The Vibrant Soundbridge (VSB) was introduced in 1996, and the fourth generation of the audio processor recently released. This clinical study evaluates the audiological performance and subjective satisfaction of the new SAMBA 2 audio processor compared to its predecessor, SAMBA.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Method<\/jats:title>\n                <jats:p>Fifteen VSB users tested both audio processors for approximately 3\u00a0weeks. Air conduction and bone conduction thresholds and unaided and aided sound field thresholds were measured with both devices. Speech performance in quiet (Freiburg monosyllables) and noise (OLSA) was evaluated as well as subjective listening effort (ACALES) and questionnaire outcomes (SSQ12 and APSQ). In addition, data from 16 subjects with normal hearing were gathered on sound field tests and ACALES.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Both audio processors showed substantial improvement compared to the unaided condition. The SAMBA and SAMBA 2 had comparable performance in sound filed thresholds, while the SAMBA 2 was significantly better in speech in quiet, speech in noise, reduced listening effort, and improved subjective satisfaction compared with the SAMBA.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The SAMBA 2 audio processor, compared to its predecessor SAMBA, offers improved performance throughout the parameters investigated in this study. Patients with a VSB implant would benefit from an upgrade to SAMBA 2.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00405-021-07207-4","type":"journal-article","created":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T06:02:30Z","timestamp":1638856950000},"page":"4667-4675","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Speech perception and hearing effort using a new active middle ear implant audio processor"],"prefix":"10.1007","volume":"279","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1859-5623","authenticated-orcid":false,"given":"Torsten","family":"Rahne","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Fr\u00f6hlich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luise","family":"Wagner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miriam Hannah","family":"Kropp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"M\u00fcller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,12,7]]},"reference":[{"key":"7207_CR1","first-page":"1","volume":"69","author":"GR Ball","year":"2010","unstructured":"Ball GR (2010) The Vibrant Soundbridge: design and development. Adv Otorhinolaryngol 69:1\u201313","journal-title":"Adv Otorhinolaryngol"},{"issue":"Suppl 1","key":"7207_CR2","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1002\/cii.294","volume":"6","author":"S Labassi","year":"2005","unstructured":"Labassi S, Beliaeff M (2005) Retrospective of 1000 patients implanted with a vibrant Soundbridge middle-ear implant. Cochlear Implants Int 6(Suppl 1):74\u201377","journal-title":"Cochlear Implants Int"},{"key":"7207_CR3","first-page":"20","volume":"69","author":"F Wagner","year":"2010","unstructured":"Wagner F et al (2010) Indications and candidacy for active middle ear implants. Adv Otorhinolaryngol 69:20\u201326","journal-title":"Adv Otorhinolaryngol"},{"issue":"4","key":"7207_CR4","doi-asserted-by":"publisher","first-page":"1797","DOI":"10.1007\/s00405-016-4361-2","volume":"274","author":"KL Bruchhage","year":"2017","unstructured":"Bruchhage KL et al (2017) Systematic review to evaluate the safety, efficacy and economical outcomes of the Vibrant Soundbridge for the treatment of sensorineural hearing loss. Eur Arch Otorhinolaryngol 274(4):1797\u20131806","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"6","key":"7207_CR5","doi-asserted-by":"publisher","first-page":"1451","DOI":"10.1002\/lary.25670","volume":"126","author":"A Ernst","year":"2016","unstructured":"Ernst A, Todt I, Wagner J (2016) Safety and effectiveness of the Vibrant Soundbridge in treating conductive and mixed hearing loss: a systematic review. Laryngoscope 126(6):1451\u20131457","journal-title":"Laryngoscope"},{"issue":"5","key":"7207_CR6","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1055\/s-0042-1748498","volume":"10","author":"DA Preves","year":"1999","unstructured":"Preves DA, Sammeth CA, Wynne MK (1999) Field trial evaluations of a switched directional\/omnidirectional in-the-ear hearing instrument. J Am Acad Audiol 10(5):273\u2013284","journal-title":"J Am Acad Audiol"},{"issue":"6","key":"7207_CR7","doi-asserted-by":"publisher","first-page":"398","DOI":"10.3766\/jaaa.17.6.3","volume":"17","author":"M Valente","year":"2006","unstructured":"Valente M et al (2006) Effect of type of noise and loudspeaker array on the performance of omnidirectional and directional microphones. J Am Acad Audiol 17(6):398\u2013412","journal-title":"J Am Acad Audiol"},{"issue":"3","key":"7207_CR8","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1159\/000506067","volume":"25","author":"D Zimmermann","year":"2020","unstructured":"Zimmermann D et al (2020) Audiological results with the SAMBA audio processor in comparison to the amade for the Vibrant Soundbridge. Audiol Neurootol 25(3):164\u2013172","journal-title":"Audiol Neurootol"},{"key":"7207_CR9","volume-title":"The SAMBA 2 audio processor\u2014technical facts and initial audiological results","author":"B Postert","year":"2020","unstructured":"Postert B (2020) The SAMBA 2 audio processor\u2014technical facts and initial audiological results. MED-EL Elektromedizinische Geraete Gesellschaft m.b.H, Starnberg"},{"key":"7207_CR10","volume-title":"Optimized directional processing in hearing aids with integrated spatial noise reduction, in IWAENC 2012; International Workshop on acoustic signal enhancement","author":"H Puder","year":"2012","unstructured":"Puder H, Fischer E, Hain J (2012) Optimized directional processing in hearing aids with integrated spatial noise reduction, in IWAENC 2012; International Workshop on acoustic signal enhancement. VDE Verlag, Aachen"},{"issue":"Suppl 1","key":"7207_CR11","doi-asserted-by":"publisher","first-page":"5S","DOI":"10.1097\/AUD.0000000000000312","volume":"37","author":"MK Pichora-Fuller","year":"2016","unstructured":"Pichora-Fuller MK et al (2016) Hearing impairment and cognitive energy: the framework for understanding effortful listening (FUEL). Ear Hear 37(Suppl 1):5S-27S","journal-title":"Ear Hear"},{"issue":"1","key":"7207_CR12","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1044\/1092-4388(2009\/08-0140)","volume":"53","author":"S Fraser","year":"2010","unstructured":"Fraser S et al (2010) Evaluating the effort expended to understand speech in noise using a dual-task paradigm: the effects of providing visual speech cues. J Speech Lang Hear Res 53(1):18\u201333","journal-title":"J Speech Lang Hear Res"},{"issue":"6","key":"7207_CR13","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1097\/AUD.0000000000000454","volume":"38","author":"D Wendt","year":"2017","unstructured":"Wendt D, Hietkamp RK, Lunner T (2017) Impact of noise and noise reduction on processing effort: a pupillometry study. Ear Hear 38(6):690\u2013700","journal-title":"Ear Hear"},{"issue":"6","key":"7207_CR14","doi-asserted-by":"publisher","first-page":"4680","DOI":"10.1121\/1.4986938","volume":"141","author":"M Krueger","year":"2017","unstructured":"Krueger M et al (2017) Development of an adaptive scaling method for subjective listening effort. J Acoust Soc Am 141(6):4680","journal-title":"J Acoust Soc Am"},{"key":"7207_CR15","doi-asserted-by":"crossref","first-page":"233121652094841","DOI":"10.1177\/2331216520948410","volume":"24","author":"AH Winneke","year":"2020","unstructured":"Winneke AH et al (2020) Effect of directional microphone technology in hearing aids on neural correlates of listening and memory effort: an electroencephalographic study. Trends Hear 24:2331216520948410","journal-title":"Trends Hear"},{"issue":"3S","key":"7207_CR16","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1044\/2017_AJA-16-0136","volume":"26","author":"M Krueger","year":"2017","unstructured":"Krueger M et al (2017) Relation between listening effort and speech intelligibility in noise. Am J Audiol 26(3S):378\u2013392","journal-title":"Am J Audiol"},{"issue":"4","key":"7207_CR17","doi-asserted-by":"publisher","first-page":"2412","DOI":"10.1121\/1.419624","volume":"102","author":"B Kollmeier","year":"1997","unstructured":"Kollmeier B, Wesselkamp M (1997) Development and evaluation of a German sentence test for objective and subjective speech intelligibility assessment. J Acoust Soc Am 102(4):2412\u20132421","journal-title":"J Acoust Soc Am"},{"issue":"5","key":"7207_CR18","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1080\/14992027.2019.1697830","volume":"59","author":"M Billinger-Finke","year":"2020","unstructured":"Billinger-Finke M et al (2020) Development and validation of the audio processor satisfaction questionnaire (APSQ) for hearing implant users. Int J Audiol 59(5):392\u2013397","journal-title":"Int J Audiol"},{"issue":"6","key":"7207_CR19","doi-asserted-by":"publisher","first-page":"409","DOI":"10.3109\/14992027.2013.781278","volume":"52","author":"W Noble","year":"2013","unstructured":"Noble W et al (2013) A short form of the speech, spatial and qualities of hearing scale suitable for clinical use: the SSQ12. Int J Audiol 52(6):409\u2013412","journal-title":"Int J Audiol"},{"issue":"2","key":"7207_CR20","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1159\/000490878","volume":"23","author":"H Maier","year":"2018","unstructured":"Maier H et al (2018) Minimal reporting standards for active middle ear hearing implants. Audiol Neurootol 23(2):105\u2013115","journal-title":"Audiol Neurootol"},{"key":"7207_CR21","volume-title":"AWMF S2k-leitlinie, cochlea-implantat versorgung","author":"Deutsche Gesellschaft f\u00fcr Hals-Nasen-Ohren-Heilkunde","year":"2020","unstructured":"Deutsche Gesellschaft f\u00fcr Hals-Nasen-Ohren-Heilkunde (2020) AWMF S2k-leitlinie, cochlea-implantat versorgung. Arbeitsgemeinschaft der Wissenschaftlichen Medizinischen Fachgesellschaften (AWMF), Frankfurt"},{"issue":"6","key":"7207_CR22","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1097\/MAO.0000000000001412","volume":"38","author":"A M\u00fcller","year":"2017","unstructured":"M\u00fcller A et al (2017) Influence of floating-mass transducer coupling efficiency for active middle-ear implants on speech recognition. Otol Neurotol 38(6):809\u2013814","journal-title":"Otol Neurotol"},{"issue":"6","key":"7207_CR23","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1007\/s00106-019-00776-1","volume":"69","author":"T Rahne","year":"2021","unstructured":"Rahne T (2021) Physikalisch-audiologische grundlagen implantierbarer h\u00f6rsysteme. HNO 69(6):475\u2013482","journal-title":"HNO"},{"issue":"2","key":"7207_CR24","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s00106-015-0087-5","volume":"64","author":"T Rahne","year":"2016","unstructured":"Rahne T, Plontke SK (2016) Device-based treatment of mixed hearing loss: an audiological comparison of current hearing systems. HNO 64(2):91\u2013100","journal-title":"HNO"},{"issue":"7","key":"7207_CR25","doi-asserted-by":"publisher","first-page":"433","DOI":"10.3109\/14992027.2014.890296","volume":"53","author":"R McGarrigle","year":"2014","unstructured":"McGarrigle R et al (2014) Listening effort and fatigue: what exactly are we measuring? A British Society of Audiology Cognition in Hearing Special Interest Group \u2018white paper.\u2019 Int J Audiol 53(7):433\u2013440","journal-title":"Int J Audiol"},{"issue":"8","key":"7207_CR26","doi-asserted-by":"publisher","first-page":"685","DOI":"10.3766\/jaaa.16014","volume":"28","author":"AE Perreau","year":"2017","unstructured":"Perreau AE et al (2017) Listening effort measured in adults with normal hearing and cochlear implants. J Am Acad Audiol 28(8):685\u2013697","journal-title":"J Am Acad Audiol"}],"container-title":["European Archives of Oto-Rhino-Laryngology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-021-07207-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00405-021-07207-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-021-07207-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,14]],"date-time":"2022-09-14T15:08:35Z","timestamp":1663168115000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00405-021-07207-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12,7]]},"references-count":26,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["7207"],"URL":"https:\/\/doi.org\/10.1007\/s00405-021-07207-4","relation":{},"ISSN":["0937-4477","1434-4726"],"issn-type":[{"value":"0937-4477","type":"print"},{"value":"1434-4726","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12,7]]},"assertion":[{"value":"9 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 November 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflicts of interest to declare that are relevant to the content of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"See \u201c\u201d Section, line 103.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"See \u201c\u201d Section, line 104.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"See \u201c\u201d Section, line 104.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}]}}