{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T11:09:46Z","timestamp":1784200186258,"version":"3.55.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2022,2,19]],"date-time":"2022-02-19T00:00:00Z","timestamp":1645228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,19]],"date-time":"2022-02-19T00:00:00Z","timestamp":1645228800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur Arch Otorhinolaryngol"],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>(1) To assess the effectiveness and safety of a bone-conduction implant, the Bonebridge BCI 602, in adults with conductive or mixed hearing loss. (2) To investigate whether the Bonebridge BCI 602 is at least as effective as the Bonebridge BCI 601 in such patients.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The study group included 42 adults who had either conductive or mixed hearing loss. All patients underwent Bonebridge BCI 602 implant surgery. Before and after implantation, pure-tone audiometry, speech recognition tests (in quiet and noise), and free-field audiometry were performed. Word recognition scores were evaluated using the Polish Monosyllabic Word Test. Speech reception thresholds in noise were assessed using the Polish Sentence Matrix Test. Subjective assessment of benefits was done using the APHAB (Abbreviated Profile of Hearing Aid Benefit) questionnaire.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The APHAB questionnaire showed that difficulties in hearing decreased after BCI 602 implantation. Both word recognition in quiet and speech reception threshold in noise were significantly better after BCI 602 implantation and remained stable for at least 12\u00a0months. A significant advantage of the device is a reduced time for surgery while maintaining safety. In this study, the mean time for BCI 602 implantation was 28.3\u00a0min\u2009\u00b1\u20099.4.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The second-generation Bonebridge BCI 602 implant is an effective hearing rehabilitation device for patients with conductive or mixed hearing loss. Patient satisfaction and audiological results confirm its efficacy and safety. Its new shape and dimensions allow it to be used in patients previously excluded due to insufficient or difficult anatomical conditions. The new BCI 602 implant is as effective as its predecessor, the BCI 601.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00405-022-07265-2","type":"journal-article","created":{"date-parts":[[2022,2,19]],"date-time":"2022-02-19T12:04:21Z","timestamp":1645272261000},"page":"3525-3534","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Evaluation of the Bonebridge BCI 602 active bone conductive implant in adults: efficacy and stability of audiological, surgical, and functional outcomes"],"prefix":"10.1007","volume":"279","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1224-1074","authenticated-orcid":false,"given":"Katarzyna B.","family":"Cywka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4978-1915","authenticated-orcid":false,"given":"Piotr H.","family":"Skarzynski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7865-9794","authenticated-orcid":false,"given":"Bartlomiej","family":"Krol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9509-9722","authenticated-orcid":false,"given":"Stavros","family":"Hatzopoulos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7141-9851","authenticated-orcid":false,"given":"Henryk","family":"Skarzynski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,2,19]]},"reference":[{"issue":"4","key":"7265_CR1","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1080\/14992027.2020.1820087","volume":"60","author":"PR Hill-Feltham","year":"2021","unstructured":"Hill-Feltham PR, Johansson ML, Hodgetts WE et al (2021) Hearing outcome measures for conductive and mixed hearing loss treatment in adults: a scoping review. Int J Audiol 60(4):239\u2013245. https:\/\/doi.org\/10.1080\/14992027.2020.1820087","journal-title":"Int J Audiol"},{"key":"7265_CR2","doi-asserted-by":"publisher","DOI":"10.12659\/AJCR.929933","volume":"22","author":"H Skar\u017cy\u0144ski","year":"2021","unstructured":"Skar\u017cy\u0144ski H, Plichta \u0141, Kr\u00f3l B, Cywka KB, Skar\u017cy\u0144ski PH (2021) Implantation of the vibrant soundbridge in a case of bilateral malformation of the middle and external ear. Am J Case Rep 22:e929933. https:\/\/doi.org\/10.12659\/AJCR.929933","journal-title":"Am J Case Rep"},{"key":"7265_CR3","doi-asserted-by":"publisher","DOI":"10.12659\/MSM.933915","volume":"27","author":"KB Cywka","year":"2021","unstructured":"Cywka KB, Kr\u00f3l B, Skar\u017cy\u0144ski PH (2021) Effectiveness of bone conduction hearing aids in young children with congenital aural atresia and microtia. Med Sci Monit 27:e933915. https:\/\/doi.org\/10.12659\/MSM.933915","journal-title":"Med Sci Monit"},{"key":"7265_CR4","doi-asserted-by":"publisher","unstructured":"(199) Committee on Hearing and Equilibrium guidelines for the evaluation of results of treatment of conductive hearing loss. Am Acad Otolaryngol-Head Neck Surg Found Inc Otolaryngol Head Neck Surg 113(3):186\u2013187. https:\/\/doi.org\/10.1016\/S0194-5998(95)70103-6","DOI":"10.1016\/S0194-5998(95)70103-6"},{"issue":"6","key":"7265_CR5","first-page":"366","volume":"45","author":"NT Phan","year":"2016","unstructured":"Phan NT, McKenzie JL, Huang L, Whitfield B, Chang A (2016) Diagnosis and management of hearing loss in elderly patients. Aust Fam Physician 45(6):366\u2013369","journal-title":"Aust Fam Physician"},{"issue":"7","key":"7265_CR6","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1097\/MAO.0000000000002323","volume":"40","author":"PH Skarzynski","year":"2019","unstructured":"Skarzynski PH, Ratuszniak A, Osinska K et al (2019) A comparative study of a novel adhesive bone conduction device and conventional treatment options for conductive hearing loss. Otol Neurotol 40(7):858\u2013864. https:\/\/doi.org\/10.1097\/MAO.0000000000002323","journal-title":"Otol Neurotol"},{"issue":"9","key":"7265_CR7","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0221484","volume":"14","author":"A Magele","year":"2019","unstructured":"Magele A, Schoerg P, Stanek B, Gradl B, Sprinzl GM (2019) Active transcutaneous bone conduction hearing implants: systematic review and meta-analysis. PLoS\u00a0One 14(9):e0221484. https:\/\/doi.org\/10.1371\/journal.pone.0221484","journal-title":"PLoS\u00a0One"},{"issue":"2","key":"7265_CR8","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1159\/000499363","volume":"24","author":"PH Skar\u017cy\u0144ski","year":"2019","unstructured":"Skar\u017cy\u0144ski PH, Ratuszniak A, Kr\u00f3l B et al (2019) The Bonebridge in adults with mixed and conductive hearing loss: audiological and quality of life outcomes. AudiolNeurootol 24(2):90\u201399. https:\/\/doi.org\/10.1159\/000499363","journal-title":"AudiolNeurootol"},{"issue":"Suppl 2","key":"7265_CR9","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1007\/s00106-020-00877-2","volume":"68","author":"SK Plontke","year":"2020","unstructured":"Plontke SK, G\u00f6tze G, Wenzel C, Rahne T, Mlynski R (2020) Implantation of a new active bone conduction hearing device with optimized geometry. HNO 68(Suppl 2):106\u2013115. https:\/\/doi.org\/10.1007\/s00106-020-00877-2","journal-title":"HNO"},{"issue":"9","key":"7265_CR10","doi-asserted-by":"publisher","first-page":"3203","DOI":"10.1007\/s00405-020-06380-2","volume":"278","author":"C Utrilla","year":"2021","unstructured":"Utrilla C, Gavil\u00e1n J, Garc\u00eda-Raya P, Calvino M, Lassaletta L (2021) MRI after Bonebridge implantation: a comparison of two implant generations. Eur Arch Otorhinolaryngol 278(9):3203\u20133209. https:\/\/doi.org\/10.1007\/s00405-020-06380-2","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"7265_CR11","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.ijporl.2019.01.016","volume":"119","author":"ME Zernotti","year":"2019","unstructured":"Zernotti ME, Chiaraviglio MM, Mauricio SB, Tabernero PA, Zernotti M, Di Gregorio MF (2019) Audiological outcomes in patients with congenital aural atresia implanted with transcutaneous active bone conduction hearing implant. Int J Pediatr Otorhinolaryngol 119:54\u201358. https:\/\/doi.org\/10.1016\/j.ijporl.2019.01.016","journal-title":"Int J Pediatr Otorhinolaryngol"},{"issue":"1","key":"7265_CR12","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1080\/14992027.2017.1370137","volume":"57","author":"S Bravo-Torres","year":"2018","unstructured":"Bravo-Torres S, Der-Mussa C, Fuentes-L\u00f3pez E (2018) Active transcutaneous bone conduction implant: audiological results in paediatric patients with bilateral microtia associated with external auditory canal atresia. IntJ Audiol 57(1):53\u201360. https:\/\/doi.org\/10.1080\/14992027.2017.1370137","journal-title":"IntJ Audiol"},{"issue":"8","key":"7265_CR13","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1017\/S0022215118001123","volume":"132","author":"LX Ngui","year":"2018","unstructured":"Ngui LX, Tang IP (2018) Bonebridge transcutaneous bone conduction implant in children with congenital aural atresia: surgical and audiological outcomes. J Laryngol Otol 132(8):693\u2013697. https:\/\/doi.org\/10.1017\/S0022215118001123","journal-title":"J Laryngol Otol"},{"key":"7265_CR14","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.ijporl.2018.12.026","volume":"118","author":"A Ratuszniak","year":"2019","unstructured":"Ratuszniak A, Skarzynski PH, Gos E, Skarzynski H (2019) The Bonebridge implant in older children and adolescents with mixed or conductive hearing loss: audiological outcomes. Int J Pediatr Otorhinolaryngol 118:97\u2013102. https:\/\/doi.org\/10.1016\/j.ijporl.2018.12.026","journal-title":"Int J Pediatr Otorhinolaryngol"},{"issue":"5","key":"7265_CR15","doi-asserted-by":"publisher","first-page":"2107","DOI":"10.1007\/s00405-016-4434-2","volume":"274","author":"R Weiss","year":"2017","unstructured":"Weiss R, Leinung M, Baumann U, Wei\u00dfgerber T, Rader T, St\u00f6ver T (2017) Improvement of speech perception in quiet and in noise without decreasing localization abilities with the bone conduction device Bonebridge. Eur Arch Otorhinolaryngol 274(5):2107\u20132115. https:\/\/doi.org\/10.1007\/s00405-016-4434-2","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"6","key":"7265_CR16","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1097\/MAO.0000000000001038","volume":"37","author":"WD Baumgartner","year":"2016","unstructured":"Baumgartner WD, Hamzavi JS, B\u00f6heim K et al (2016) A new transcutaneous bone conduction hearing implant: short-term safety and efficacy in children. Otol sNeurotol 37(6):713\u2013720. https:\/\/doi.org\/10.1097\/MAO.0000000000001038","journal-title":"Otol sNeurotol"},{"issue":"8","key":"7265_CR17","doi-asserted-by":"publisher","first-page":"21652170","DOI":"10.1007\/s00405-019-05450-4","volume":"276","author":"A Canale","year":"2019","unstructured":"Canale A, Boggio V, Albera A et al (2019) A new bone conduction hearing aid to predict hearing outcome with an active implanted device. Eur Arch Otorhinolaryngol 276(8):21652170. https:\/\/doi.org\/10.1007\/s00405-019-05450-4","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"7265_CR18","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-021-06626-7","author":"I Seiwerth","year":"2021","unstructured":"Seiwerth I, Fr\u00f6hlich L, Schilde S, G\u00f6tze G, Plontke SK, Rahne T (2021) Clinical and functional results after implantation of the bonebridge, a semi-implantable, active transcutaneous bone conduction device, in children and adults. Eur Arch Otorhinolaryngol. https:\/\/doi.org\/10.1007\/s00405-021-06626-7","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"5","key":"7265_CR19","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1097\/MAO.0000000000002585","volume":"41","author":"FA Almuhawas","year":"2020","unstructured":"Almuhawas FA, Dhanasingh AE, Mitrovic D et al (2020) Age as a factor of growth in mastoid thickness and skull width. Otol Neurotol 41(5):709\u2013714. https:\/\/doi.org\/10.1097\/MAO.0000000000002585","journal-title":"Otol Neurotol"},{"issue":"7","key":"7265_CR20","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1177\/0003489420970217","volume":"130","author":"SAW Andersen","year":"2021","unstructured":"Andersen SAW, Bergman M, Keith JP et al (2021) Segmentation of temporal bone anatomy for patient-specific virtual reality simulation. Ann Otol Rhinol Laryngol 130(7):724\u2013730. https:\/\/doi.org\/10.1177\/0003489420970217","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"7265_CR21","doi-asserted-by":"publisher","first-page":"233121651986298","DOI":"10.1177\/2331216519862982","volume":"23","author":"T Nuesse","year":"2019","unstructured":"Nuesse T, Wiercinski B, Brand T, Holube I (2019) Measuring speech recognition with a matrix test using synthetic speech. Trends Hear 23:2331216519862982. https:\/\/doi.org\/10.1177\/2331216519862982","journal-title":"Trends Hear"},{"issue":"10","key":"7265_CR22","doi-asserted-by":"publisher","first-page":"3593","DOI":"10.1007\/s00405-017-4680-y","volume":"274","author":"J L\u00f6hler","year":"2017","unstructured":"L\u00f6hler J, Gr\u00e4bner F, Wollenberg B, Schlattmann P, Sch\u00f6nweiler R (2017) Sensitivity and specificity of the abbreviated profile of hearing aid benefit (APHAB). Eur Arch Otorhinolaryngol 274(10):3593\u20133598. https:\/\/doi.org\/10.1007\/s00405-017-4680-y","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"2","key":"7265_CR23","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/00003446-199504000-00005","volume":"16","author":"RM Cox","year":"1995","unstructured":"Cox RM, Alexander GC (1995) The abbreviated profile of hearing aid benefit. Ear Hear 16(2):176\u2013186. https:\/\/doi.org\/10.1097\/00003446-199504000-00005","journal-title":"Ear Hear"},{"issue":"8","key":"7265_CR24","doi-asserted-by":"publisher","first-page":"797","DOI":"10.15537\/smj.2019.8.24383","volume":"40","author":"F Alzhrani","year":"2019","unstructured":"Alzhrani F (2019) Objective and subjective results of the Bonebridge transcutaneous active direct-drive bone conduction hearing implant. Saudi Med J 40(8):797\u2013801. https:\/\/doi.org\/10.15537\/smj.2019.8.24383","journal-title":"Saudi Med J"},{"issue":"8","key":"7265_CR25","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1097\/MAO.0000000000003230","volume":"42","author":"GM Sprinzl","year":"2021","unstructured":"Sprinzl GM, Schoerg P, Ploder M, Edlinger SH, Magele A (2021) Surgical experience and early audiological outcomes with new active transcutaneous bone conduction implant. OtolNeurotol 42(8):1208\u20131215. https:\/\/doi.org\/10.1097\/MAO.0000000000003230","journal-title":"OtolNeurotol"},{"key":"7265_CR26","doi-asserted-by":"publisher","DOI":"10.12659\/AJCR.925914","volume":"21","author":"B Kr\u00f3l","year":"2020","unstructured":"Kr\u00f3l B, Porowski M, Cywka KB, Skar\u017cy\u0144ska MB, Skar\u017cy\u0144ski PH (2020) Mastoid obliteration with s53p4 bioactive glass can make bonebridge implantation feasible: a case report. Am J Case Rep 21:e925914. https:\/\/doi.org\/10.12659\/AJCR.925914","journal-title":"Am J Case Rep"},{"issue":"2","key":"7265_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2020.102895","volume":"42","author":"B Kr\u00f3l","year":"2021","unstructured":"Kr\u00f3l B, Cywka KB, Skar\u017cy\u0144ska MB, Skar\u017cy\u0144ski PH (2021) Mastoid obliteration with S53P4 bioactive glass after canal wall down mastoidectomy: preliminary results. Am J Otolaryngol 42(2):102895. https:\/\/doi.org\/10.1016\/j.amjoto.2020.102895","journal-title":"Am J Otolaryngol"},{"issue":"5","key":"7265_CR28","doi-asserted-by":"publisher","first-page":"374","DOI":"10.3390\/life11050374","volume":"11","author":"B Kr\u00f3l","year":"2021","unstructured":"Kr\u00f3l B, Cywka KB, Skar\u017cy\u0144ska MB, Skar\u017cy\u0144ski PH (2021) Implantation of the Bonebridge BCI 602 after mastoid obliteration with S53P4 bioactive glass: a safe method of treating difficult anatomical conditions-preliminary results. Life (Basel) 11(5):374. https:\/\/doi.org\/10.3390\/life11050374","journal-title":"Life (Basel)"},{"issue":"2","key":"7265_CR29","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1097\/MAO.0000000000000253","volume":"35","author":"M Manrique","year":"2014","unstructured":"Manrique M, Sanhueza I, Manrique R, de Abajo J (2014) A new bone conduction implant: surgical technique and results. Otol Neurotol 35(2):216\u2013220. https:\/\/doi.org\/10.1097\/MAO.0000000000000253","journal-title":"Otol Neurotol"},{"issue":"3","key":"7265_CR30","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1097\/MAO.0000000000000969","volume":"37","author":"KE Eberhard","year":"2016","unstructured":"Eberhard KE, Olsen S\u00d8, Miyazaki H, Bille M, Caye-Thomasen P (2016) Objective and subjective outcome of a new transcutaneous bone conduction hearing device: halfyear follow-up of the first 12 nordic implantations. OtolNeurotol 37(3):267\u2013275. https:\/\/doi.org\/10.1097\/MAO.0000000000000969","journal-title":"OtolNeurotol"},{"issue":"4","key":"7265_CR31","doi-asserted-by":"publisher","first-page":"1835","DOI":"10.1007\/s00405-016-4228-6","volume":"274","author":"S Schmerber","year":"2017","unstructured":"Schmerber S, Deguine O, Marx M et al (2017) Safety and effectiveness of the Bonebridge transcutaneous active direct-drive bone-conduction hearing implant at 1-year device use. Eur Arch Otorhinolaryngol 274(4):1835\u20131851. https:\/\/doi.org\/10.1007\/s00405-016-4228-6","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"1","key":"7265_CR32","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1159\/000371425","volume":"77","author":"G Bianchin","year":"2015","unstructured":"Bianchin G, Bonali M, Russo M, Tribi L (2015) Active bone conduction system: outcomes with the Bonebridge transcutaneous device. ORL J Otorhinolaryngol Relat Spec 77(1):17\u201326. https:\/\/doi.org\/10.1159\/000371425","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"issue":"8","key":"7265_CR33","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1097\/MAO.0000000000002370","volume":"40","author":"X Fan","year":"2019","unstructured":"Fan X, Yang T, Niu X, Wang Y, Fan Y, Chen X (2019) Long-term outcomes of bone conduction hearing implants in patients with bilateral microtia-atresia. Otol Neurotol 40(8):998\u20131005. https:\/\/doi.org\/10.1097\/MAO.0000000000002370","journal-title":"Otol Neurotol"},{"issue":"10","key":"7265_CR34","doi-asserted-by":"publisher","first-page":"E1614","DOI":"10.3390\/jcm8101614","volume":"8","author":"FF Brkic","year":"2019","unstructured":"Brkic FF, Riss D, Scheuba K et al (2019) Medical, technical and audiological outcomes of hearing rehabilitation with the bonebridge transcutaneous bone-conduction implant: a single-center experience. J Clin Med 8(10):E1614. https:\/\/doi.org\/10.3390\/jcm8101614","journal-title":"J Clin Med"},{"issue":"7","key":"7265_CR35","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1097\/MAO.0000000000001834","volume":"39","author":"T Rader","year":"2018","unstructured":"Rader T, St\u00f6ver T, Lenarz T et al (2018) Retrospective analysis of hearing-impaired adult patients treated with an active transcutaneous bone conduction implant. Otol Neurotol 39(7):874\u2013881. https:\/\/doi.org\/10.1097\/MAO.0000000000001834","journal-title":"Otol Neurotol"},{"issue":"5","key":"7265_CR36","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.anl.2018.12.012","volume":"46","author":"W Wimmer","year":"2019","unstructured":"Wimmer W, von Werdt M, Mantokoudis G, Anschuetz L, Kompis M, Caversaccio M (2019) Outcome prediction for Bonebridge candidates based on audiological indication criteria. Auris Nasus Larynx 46(5):681\u2013686. https:\/\/doi.org\/10.1016\/j.anl.2018.12.012","journal-title":"Auris Nasus Larynx"},{"issue":"12","key":"7265_CR37","doi-asserted-by":"publisher","first-page":"28022806","DOI":"10.1002\/lary.24832","volume":"124","author":"D Riss","year":"2014","unstructured":"Riss D, Arnoldner C, Baumgartner WD et al (2014) Indication criteria and outcomes with the Bonebridge transcutaneous bone-conduction implant. Laryngoscope 124(12):28022806. https:\/\/doi.org\/10.1002\/lary.24832","journal-title":"Laryngoscope"},{"issue":"6","key":"7265_CR38","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1097\/MAO.0000000000001010","volume":"37","author":"T Gerdes","year":"2016","unstructured":"Gerdes T, Salcher RB, Schwab B, Lenarz T, Maier H (2016) Comparison of audiological results between a transcutaneous and a percutaneous bone conduction instrument in conductive hearing loss. Otol Neurotol 37(6):685\u2013691. https:\/\/doi.org\/10.1097\/MAO.0000000000001010","journal-title":"Otol Neurotol"},{"issue":"6","key":"7265_CR39","doi-asserted-by":"publisher","first-page":"556","DOI":"10.3109\/00016489.2016.1143119","volume":"136","author":"ME Zernotti","year":"2016","unstructured":"Zernotti ME, Di Gregorio MF, Galeazzi P, Tabernero P (2016) Comparative outcomes of active and passive hearing devices by transcutaneous bone conduction. Acta Otolaryngol 136(6):556\u2013558. https:\/\/doi.org\/10.3109\/00016489.2016.1143119","journal-title":"Acta Otolaryngol"},{"issue":"3","key":"7265_CR40","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1080\/00016489.2019.1691744","volume":"140","author":"M Goycoolea","year":"2020","unstructured":"Goycoolea M, Ribalta G, Tocornal F et al (2020) Clinical performance of the OsiaTM system, a new active osseointegrated implant system. Results from a prospective clinical investigation. Acta Otolaryngol 140(3):212\u2013219. https:\/\/doi.org\/10.1080\/00016489.2019.1691744","journal-title":"Acta Otolaryngol"},{"issue":"8","key":"7265_CR41","doi-asserted-by":"publisher","first-page":"3011","DOI":"10.1007\/s00405-017-4614-8","volume":"274","author":"DD Hougaard","year":"2017","unstructured":"Hougaard DD, Boldsen SK, Jensen AM, Hansen S, Thomassen PC (2017) A multicenter study on objective and subjective benefits with a transcutaneous bone-anchored hearing aid device: first Nordic results. Eur Arch Otorhinolaryngol 274(8):3011\u20133019. https:\/\/doi.org\/10.1007\/s00405-017-4614-8","journal-title":"Eur Arch Otorhinolaryngol"},{"issue":"5","key":"7265_CR42","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1080\/14992027.2019.1697830","volume":"59","author":"M Billinger-Finke","year":"2020","unstructured":"Billinger-Finke M, Br\u00e4cker T, Weber A, Amann E, Anderson I, Batsoulis C (2020) Development and validation of the audio processor satisfaction questionnaire (APSQ) for hearing implant users. Int J Audiol 59(5):392\u2013397. https:\/\/doi.org\/10.1080\/14992027.2019.1697830","journal-title":"Int J Audiol"}],"container-title":["European Archives of Oto-Rhino-Laryngology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-022-07265-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00405-022-07265-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00405-022-07265-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,24]],"date-time":"2022-05-24T05:08:38Z","timestamp":1653368918000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00405-022-07265-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,19]]},"references-count":42,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["7265"],"URL":"https:\/\/doi.org\/10.1007\/s00405-022-07265-2","relation":{},"ISSN":["0937-4477","1434-4726"],"issn-type":[{"value":"0937-4477","type":"print"},{"value":"1434-4726","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,19]]},"assertion":[{"value":"22 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors disclose no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The study protocol was approved by the Institutional Review Board of the Institute of Physiology and Pathology of Hearing (IFPS:\/KB\/7\/2020).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This study was conducted in accordance with ethical standards of the Institutional Review Board and conformed to the Helsinki Declaration.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Research involving human participants and\/or animals"}},{"value":"Patients signed the informed consent form before the study was started.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}