{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T04:56:04Z","timestamp":1781067364010,"version":"3.54.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,1,10]],"date-time":"2023-01-10T00:00:00Z","timestamp":1673308800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,10]],"date-time":"2023-01-10T00:00:00Z","timestamp":1673308800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiat Environ Biophys"],"published-print":{"date-parts":[[2023,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This work presents the exposure of hands of the personnel of a nuclear medicine department who prepare and administer\n                    <jats:sup>68<\/jats:sup>\n                    Ga-DOTA-TATE. Dosimetry measurements were performed during three 1-week sessions, for nine production procedures. A total of 360 measurements were made by using high-sensitivity MCP-N thermoluminescent detectors. Annealed detectors were and vacuum-packed in foil and then placed on each fingertip of both hands of five radiochemists and four nurses (one detector for one fingertip). The greatest exposure to ionizing radiation was found on the non-dominant left hand of radiochemists and nurses. A maximum\n                    <jats:italic>H<\/jats:italic>\n                    <jats:sub>p<\/jats:sub>\n                    (0.07)\/A value of 49.36\u2009\u00b1\u20094.95\u00a0mSv\/GBq was registered for radiochemists during the\n                    <jats:sup>68<\/jats:sup>\n                    \u00a0Ga-DOTA-DATE activity dispensing procedure. For nurses performing the radiopharmaceutical injection procedure, a corresponding maximum value of 1.28\u2009\u00b1\u20090.13\u00a0mSv\/GBq was measured, while the mean value for all the nurses was 0.38\u00a0mSv\/GBq. The dispensing procedure accounted for approximately 60% of the total exposure of radiochemists' fingertips. Based on the results obtained it is recommended that a ring dosimeter should be routinely placed on the middle finger of the non-dominant hand of radiochemists and nurses. Furthermore, it is proposed to systematically train workers in handling open sources of ionizing radiation, with the aim of reducing the required handling time.\n                  <\/jats:p>","DOI":"10.1007\/s00411-022-01015-y","type":"journal-article","created":{"date-parts":[[2023,1,10]],"date-time":"2023-01-10T00:02:58Z","timestamp":1673308978000},"page":"117-129","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Personal dose equivalent Hp(0.07) during 68Ga-DOTA-TATE production procedures"],"prefix":"10.1007","volume":"62","author":[{"given":"M.","family":"Wrzesie\u0144","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u0141.","family":"Albiniak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,1,10]]},"reference":[{"key":"1015_CR1","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1097\/00006231-199105000-00008","volume":"12","author":"S Batchelor","year":"1991","unstructured":"Batchelor S, Penfold A, Aric I, Huggins R (1991) Radiation dose to hands in nuclear medicine. Nucl Med Commun 12:439\u2013444","journal-title":"Nucl Med Commun"},{"key":"1015_CR2","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1007\/s00259-004-1702-y","volume":"32","author":"WA Breeman","year":"2005","unstructured":"Breeman WA, de Jong M, de Blois E, Bernard BF, Konijnenberg M, Krenning EP (2005) Radiolabelling DOTA-peptides with 68Ga. Eur J Nucl Med Mol Imaging 32:478\u2013485","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1015_CR3","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1016\/j.radmeas.2011.07.019","volume":"46","author":"A Carnicer","year":"2011","unstructured":"Carnicer A, Sans-Merce M, Baechler S, Barth I, Donadille L, Ferrari P, Fulop M, Ginjaume M, Gualdrini G, Krim S, Mariotti M, Ortega X, Rimpler A, Ruiz N, Vanhavere F (2011) Hand exposure in diagnostic nuclear medicine with 18F- and 99mTc-labelled radiopharmaceuticals\u2014results of the ORAMED project. Radiat Measur 46:1277\u20131282","journal-title":"Radiat Measur"},{"issue":"11","key":"1015_CR4","doi-asserted-by":"publisher","first-page":"1380","DOI":"10.1007\/s002590050164","volume":"24","author":"C Chiesa","year":"1997","unstructured":"Chiesa C, De Sanctis V, Crippa F, Schiavini M, Fraigola CE, Bogni A, Pascali C, Decise D, Marchesini R, Bombardieri E (1997) Radiation dose to technicians per nuclear medicine procedure: comparison between technetium\u201499m, gallium\u201467 and iodine\u2014131 radiotracers and fluorine\u201418 fluorodeoxyglucose. Eur J Nucl Med 24(11):1380\u20131389","journal-title":"Eur J Nucl Med"},{"key":"1015_CR5","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1097\/00006231-200006000-00003","volume":"21","author":"S Dhanse","year":"2000","unstructured":"Dhanse S, Martin CJ, Hilditch TE, Elliott AT (2000) A study of doses to the hands during dispensing of radiopharmaceuticals. Nucl Med Commun 21:511\u2013519","journal-title":"Nucl Med Commun"},{"key":"1015_CR6","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1007\/s00259-010-1407-3","volume":"37","author":"P Elsinga","year":"2010","unstructured":"Elsinga P, Todde S, Penuelas I, Meyer G, Farstad B, Faivre-Chauvet A, Mikolajczak R, Westera G, Gmeiner-Stopar T, Decristoforo C (2010) Radiopharmacy Committee of the EANM. Guidance on current good radiopharmacy practice (cGRPP) for the small-scale preparation of radiopharmaceuticals. Eur J Nucl Med Mol Imaging 37:1049\u20131062","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1015_CR7","unstructured":"Guidelines on current good Radiopharmacy Practice (cGRPP) in the Preparation of Radiopharmaceuticals. http:\/\/www.eanm.org\/scientific_info\/guidelines\/gl_radioph_cgrpp.pdf"},{"key":"1015_CR8","unstructured":"International Organization for Standardization (ISO) (1999) X and gamma reference radiation for calibrating dosemeters and doserate meters and determining their response as a function of photon energy. Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence (Geneva: ISO) International Standard ISO- 4037\u20133"},{"key":"1015_CR9","doi-asserted-by":"publisher","first-page":"R60","DOI":"10.1088\/1361-6498\/ac31a2","volume":"41","author":"R Kollaard","year":"2021","unstructured":"Kollaard R, Zorz A, Dabin J, Covens P, Cooke J, Crabb\u00e9 M, Cunha L, Dowling A, Ginjaume M, Leanne McNamara L (2021) Review of extremity dosimetry in nuclear medicine. J Radiol Prot 41:R60\u2013R87","journal-title":"J Radiol Prot"},{"key":"1015_CR10","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1016\/j.radmeas.2014.04.021","volume":"71","author":"ALSL Kubo","year":"2014","unstructured":"Kubo ALSL, Mauricio CLP (2014) TLD occupational dose distribution study in nuclear medicine. Radiat Meas 71:442\u2013446","journal-title":"Radiat Meas"},{"key":"1015_CR11","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1093\/rpd\/ncr213","volume":"149","author":"S Leide-Svegborn","year":"2011","unstructured":"Leide-Svegborn S (2011) External radiation exposure of personnel in nuclear medicine from 18F, 99mTc and 131I with special reference to fingers, eyes and thyroid. Radiat Prot Dosim 149:196\u2013206","journal-title":"Radiat Prot Dosim"},{"key":"1015_CR12","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1002\/jlcr.3821","volume":"63","author":"M Meisenheimer","year":"2020","unstructured":"Meisenheimer M, K\u00fcrpig S, Essler M, Eppard E (2020) Manual vs. automated 68Ga-radiolabeling\u2014a comparison of optimized processes. J Labelled Compd Radiopharm 63:162\u2013173","journal-title":"J Labelled Compd Radiopharm"},{"key":"1015_CR13","doi-asserted-by":"crossref","unstructured":"Piciu D (2012) Nuclear Endocrinology. Springer 2012. ISBN 978-3-642-25013-2","DOI":"10.1007\/978-3-642-25014-9_1"},{"key":"1015_CR14","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.radmeas.2010.11.005","volume":"46","author":"AS Sandouqa","year":"2011","unstructured":"Sandouqa AS, Haddadin IM, Abu-Khaled YS (2011) Hand equivalent doses of nuclear medicine staff in Jordan: Preliminary experimental studies. Radiat Meas 46:250\u2013253","journal-title":"Radiat Meas"},{"key":"1015_CR15","doi-asserted-by":"publisher","first-page":"1330","DOI":"10.1016\/j.radmeas.2011.07.011","volume":"46","author":"M Sans-Merce","year":"2011","unstructured":"Sans-Merce M, Ruiz N, Barth I, Carnicer A, Donadille L, Ferrari P, Fulop M, Ginjaume M, Gualdrini G, Krim S, Mariotti M, Ortega X, Rimpler A, Vanhavere F, Baechler S (2011) Recommendations to reduce hand exposure for standard nuclear medicine procedures. Radiat Meas 46:1330\u20131333","journal-title":"Radiat Meas"},{"key":"1015_CR16","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1093\/rpd\/ncq574","volume":"144","author":"M Sans Merce","year":"2011","unstructured":"Sans Merce M, Ruiz N, Barth I, Carnicer A, Donadille L, Ferrari P, Fulop M, Ginjaume M, Gualdrini G, Krim S, Mariotti F, Ortega X, Rimpler A, Vanhavere F, Baechler S (2011) Extremity exposure in nuclear medicine: preliminary results of a European study. Radiat Prot Dosim 144:515\u2013520","journal-title":"Radiat Prot Dosim"},{"key":"1015_CR17","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1093\/rpd\/34.1-4.127","volume":"34","author":"E Stuarto","year":"1990","unstructured":"Stuarto E (1990) Hand dose levels in Chilean nuclear medicine laboratories. Radiat Prot Dosimetry 34:127\u2013130","journal-title":"Radiat Prot Dosimetry"},{"key":"1015_CR18","unstructured":"Vanhavere F, Carinou E, Gualdrini G, Clairand I, Sans Merce M, Ginjaume M, Nikodemova D, Jankowski J, Bordy J-M, Rimpler A, Wach S, Martin P, Struelens L, Krim S, Koukorava C, Ferrari P, Mariotti F, Fantuzzi E, Donadille L, Iti\u00e9 C, Ruiz N, Carnicer A, Fulop M, Domienik J, Brodecki M, Daures J, Barth I, Bilski P (2012) Optimization of radiation protection of medical staff EURADOS Report 2012-02 Braunschweig"},{"key":"1015_CR19","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1097\/00006231-199004000-00003","volume":"11","author":"D Williams","year":"1990","unstructured":"Williams D, Baird EE, Forster E (1990) Monitoring radiation dose to the hands in nuclear medicine: location of dosemeters. Nucl Med Commun 11:271\u2013277","journal-title":"Nucl Med Commun"},{"key":"1015_CR20","doi-asserted-by":"publisher","first-page":"317","DOI":"10.13075\/mp.5893.00687","volume":"69","author":"M Wrzesie\u0144","year":"2018","unstructured":"Wrzesie\u0144 M (2018) Simplicity or complexity of the radiopharmaceutical production process in the light of optimization of radiation protection of staff\u201499mTc vs. 18F. Med Pr 69:317\u2013327","journal-title":"Med Pr"},{"key":"1015_CR21","doi-asserted-by":"publisher","first-page":"N67","DOI":"10.1088\/0952-4746\/36\/4\/N67","volume":"36","author":"M Wrzesie\u0144","year":"2016","unstructured":"Wrzesie\u0144 M, Albiniak \u0141 (2016) Hand exposure of workers in 18F-FDG production centre. J Radiol Prot 36:N67-76","journal-title":"J Radiol Prot"},{"key":"1015_CR22","doi-asserted-by":"publisher","first-page":"1512","DOI":"10.1088\/1361-6498\/aaea8e","volume":"38","author":"M Wrzesie\u0144","year":"2018","unstructured":"Wrzesie\u0144 M, Albiniak \u0141 (2018) 68 Ga-DOTA-TATE-a source of eye lens exposure for nuclear medicine department workers. J Radiol Prot 38:1512\u20131523","journal-title":"J Radiol Prot"},{"key":"1015_CR23","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1088\/0952-4746\/35\/1\/197","volume":"35","author":"M Wrzesie\u0144","year":"2015","unstructured":"Wrzesie\u0144 M, Napolska K (2015) Investigation of radiation protection of medical staff performing medical diagnostic examinations by using PET\/CT technique. J Radiol Prot 35:197\u2013207","journal-title":"J Radiol Prot"},{"key":"1015_CR24","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1093\/rpd\/ncn057","volume":"130","author":"M Wrzesie\u0144","year":"2008","unstructured":"Wrzesie\u0144 M, Olszewski J, Jankowski J (2008) Hand exposure to ionising radiation of nuclear medicine workers. Radiat Prot Dosim 130:325\u2013330","journal-title":"Radiat Prot Dosim"},{"key":"1015_CR25","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1093\/rpd\/ncy203","volume":"184","author":"M Wrzesie\u0144","year":"2019","unstructured":"Wrzesie\u0144 M, Albiniak \u0141, Biega\u0142a M (2019) The structure of Hp(0.07) values obtained by the nuclear medicine personnel during 18F-FDG production and injection. Radiat Prot Dosimetry 184:224\u2013229","journal-title":"Radiat Prot Dosimetry"}],"container-title":["Radiation and Environmental Biophysics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00411-022-01015-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00411-022-01015-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00411-022-01015-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,23]],"date-time":"2023-02-23T16:21:16Z","timestamp":1677169276000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00411-022-01015-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,10]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,3]]}},"alternative-id":["1015"],"URL":"https:\/\/doi.org\/10.1007\/s00411-022-01015-y","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-1529002\/v1","asserted-by":"object"}]},"ISSN":["0301-634X","1432-2099"],"issn-type":[{"value":"0301-634X","type":"print"},{"value":"1432-2099","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,10]]},"assertion":[{"value":"6 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}