{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:30:26Z","timestamp":1787027426823,"version":"build-2736575974"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T00:00:00Z","timestamp":1780876800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T00:00:00Z","timestamp":1780876800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiat Environ Biophys"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1007\/s00411-026-01228-5","type":"journal-article","created":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T10:39:15Z","timestamp":1780915155000},"page":"863-871","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Towards a phantom-based quantitative assessment of dose reduction and image-quality trade-offs in half- and full-rotation dental CBCT protocols: a thermoluminescent dosimetry approach with clinical insight"],"prefix":"10.1007","volume":"65","author":[{"given":"Hakan","family":"Amasya","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osman","family":"G\u00fcnay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fahrettin Fatih","family":"Kesmezacar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emine Tuna","family":"Akdo\u011fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Duygu","family":"Tun\u00e7man Kayaokay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Song\u00fcl \u00c7avdar","family":"Kara\u00e7am","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nami","family":"Yeyin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mustafa","family":"Demir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaan","family":"Orhan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ghada","family":"ALMisned","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. O.","family":"Tekin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,8]]},"reference":[{"key":"1228_CR1","doi-asserted-by":"crossref","unstructured":"Al-Okshi A, Horner K, Rohlin M (2021) A meta-review of effective doses in dental and maxillofacial cone beam CT using the ROBIS tool. Br J Radiol, 94(1123)","DOI":"10.1259\/bjr.20210042"},{"key":"1228_CR2","doi-asserted-by":"crossref","unstructured":"Amasya H, \u00d6zel \u015e, Kayaokay DT, Kara\u00e7am S\u00c7, Orhan K, Demir M (2025a) Comparing Anthropometric and Quality Assurance Phantoms in Quantitative Image Quality Testing for CBCT Imaging, vol 14. ADO Klinik Bilimler Dergisi, pp 101\u2013108. 2","DOI":"10.54617\/adoklinikbilimler.1546507"},{"key":"1228_CR3","doi-asserted-by":"crossref","unstructured":"Amasya H, G\u00fcnay O, Kesmezacar F, Tun\u00e7man D, Yeyin N, Keke\u00e7 E, Zengin T, Orhan K, Kara\u00e7am S\u00c7, Demir M (2025b) Head and Neck Imaging with a Dental CBCT Device: Comparison of 360\u00b0 and 180\u00b0 Rotation Angles in Effective Dose and Quantitative Image Quality in a Phantom Study Head. Curr Med Imaging, 21(1)","DOI":"10.2174\/0115734056316438241203095215"},{"issue":"4","key":"1228_CR4","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1093\/rpd\/ncn187","volume":"129","author":"MW Charles","year":"2008","unstructured":"Charles MW (2008) ICRP Publication 103: Recommendations of the ICRP\u2020. Radiat Prot Dosimetry 129(4):500\u2013507","journal-title":"Radiat Prot Dosimetry"},{"key":"1228_CR5","doi-asserted-by":"crossref","unstructured":"Costa EDD, Queiroz PM, Santaella GM, Capelozza ALA, Ambrosano GMB, Freitas DQ (2019) Influence of scan mode (partial\/full rotations) and FOV size in the formation of artefacts in cone beam CT. Dentomaxillofacial Radiol, 48(4)","DOI":"10.1259\/dmfr.20180340"},{"key":"1228_CR6","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.ejmp.2017.05.069","volume":"39","author":"HDLH Gala","year":"2017","unstructured":"Gala HDLH, Torresin A, Dasu A, Rampado O, Delis H, Gir\u00f3n IH, Theodorakou C, Andersson J, Holroyd J, Nilsson M, Edyvean S, Gershan V, Hadid-Beurrier L, Hoog C, Delpon G, Kolster IS, Peterlin P, Roca JG, Caprile P, Zervides C (2017) Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report). Physica Med 39:67\u201372","journal-title":"Physica Med"},{"key":"1228_CR7","doi-asserted-by":"crossref","unstructured":"Hung KF, Hui L, Yeung AWK, Jacobs R, Leung YY, Bornstein MM (2022) An analysis of patient dose received during cone-beam computed tomography in relation to scan settings and imaging indications as seen in a dental institution in order to establish institutional diagnostic reference levels. Dentomaxillofacial Radiol, 51(5)","DOI":"10.1259\/dmfr.20200529"},{"issue":"12","key":"1228_CR8","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1007\/s00784-024-06022-5","volume":"28","author":"KF Hung","year":"2024","unstructured":"Hung KF, Yeung AWK, Wong MCM, Bornstein MM, Leung YY (2024) Comparing standard- and low-dose CBCT in diagnosis and treatment decisions for impacted mandibular third molars: a non-inferiority randomised clinical study. Clin Oral Invest 28(12):647","journal-title":"Clin Oral Invest"},{"issue":"21","key":"1228_CR9","doi-asserted-by":"publisher","first-page":"7402","DOI":"10.3390\/s21217402","volume":"21","author":"AA-H Husain","year":"2021","unstructured":"Husain AA-H, D\u00f6belin Q, Giacomelli-Hiestand B, Wiedemeier DB, Stadlinger B, Valdec S (2021) Diagnostic Accuracy of Cystic Lesions Using a Pre-Programmed Low-Dose and Standard-Dose Dental Cone-Beam Computed Tomography Protocol: An Ex Vivo Comparison Study. Sensors 21(21):7402","journal-title":"Sensors"},{"key":"1228_CR10","doi-asserted-by":"crossref","unstructured":"Irsal M, Nurbaiti, Mukhtar AN, Jauhari A, Winarno G (2020) Variation kVp and mAs on CT scan image quality using standard phantom. AIP Conference Proceedings, 2296(1)","DOI":"10.1063\/5.0030320"},{"issue":"3","key":"1228_CR11","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.oooo.2024.03.013","volume":"138","author":"L Kaaber","year":"2024","unstructured":"Kaaber L, Matzen LH, Schropp L, Spin-Neto R (2024) Low-dose CBCT protocols in implant dentistry: a systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol 138(3):427\u2013439","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"1","key":"1228_CR12","first-page":"813768","volume":"2012","author":"DC Lorenzoni","year":"2012","unstructured":"Lorenzoni DC, Bolognese AM, Garib DG, Guedes FR, Sant\u2019anna EF (2012) Cone-Beam Computed Tomography and Radiographs in Dentistry: Aspects Related to Radiation Dose. Int J Dent 2012(1):813768","journal-title":"Int J Dent"},{"key":"1228_CR13","doi-asserted-by":"crossref","unstructured":"Mah E, Ritenour ER, Yao H (2020) A review of dental cone-beam CT dose conversion coefficients. Dentomaxillofacial Radiol, 50(3)","DOI":"10.1259\/dmfr.20200225"},{"issue":"9","key":"1228_CR14","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1007\/s00784-025-06499-8","volume":"29","author":"JF Mazzi-Chaves","year":"2025","unstructured":"Mazzi-Chaves JF, Ramirez I, Alceb\u00edades GCG, Lopes JG, Candemil AP, Fontenele RC, Lopes-Olh\u00ea FC, Viccari C, Nicolucci P, Brasil DM, Oliveira-Santos C, Sousa-Neto MD, Ga\u00eata-Araujo H (2025) Impact of imaging protocol and tube current adjustment on the radiation dose in CBCT imaging of mandibular incisors. Clin Oral Invest 29(9):411","journal-title":"Clin Oral Invest"},{"key":"1228_CR15","first-page":"32","volume":"19","author":"A Niktash","year":"2022","unstructured":"Niktash A, Mehralizadeh S, Talaeipour A (2022) The Effect of Different Field of View Sizes on Contrast-to-Noise Ratio of Cone-Beam Computed Tomography Units: An In-Vitro Study. Front Dent 19:32","journal-title":"Front Dent"},{"issue":"15","key":"1228_CR16","doi-asserted-by":"publisher","first-page":"15TR04","DOI":"10.1088\/1361-6560\/ac80e7","volume":"67","author":"N Okkalidis","year":"2022","unstructured":"Okkalidis N (2022) 3D printing methods for radiological anthropomorphic phantoms. Phys Med Biol 67(15):15TR04","journal-title":"Phys Med Biol"},{"key":"1228_CR17","doi-asserted-by":"crossref","unstructured":"Pauwels R, Zhang G, Theodorakou C, Walker A, Bosmans H, Jacobs R, Bogaerts R, Horner K, The SEDENTEXCT Project Consortium (2014), Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation. Br J Radiol, 87(1042)","DOI":"10.1259\/bjr.20130654"},{"issue":"5","key":"1228_CR18","doi-asserted-by":"publisher","first-page":"4173","DOI":"10.1007\/s00784-022-04389-x","volume":"26","author":"M Ruetters","year":"2022","unstructured":"Ruetters M, Gehrig H, Kronsteiner D, Doll S, Kim TS, Lux CJ, Sen S (2022) Low-dose CBCT imaging of alveolar buccal bone adjacent to mandibular anterior teeth\u2014 a pilot study. Clin Oral Invest 26(5):4173\u20134182","journal-title":"Clin Oral Invest"},{"issue":"3\u20134","key":"1228_CR19","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1093\/rpd\/ncab069","volume":"195","author":"I Shatskiy","year":"2021","unstructured":"Shatskiy I (2021) Effective Doses And Radiation Risk from Common Dental Radiographic, Panoramic and CBCT Examinations. Radiat Prot Dosimetry 195(3\u20134):296\u2013305","journal-title":"Radiat Prot Dosimetry"},{"key":"1228_CR20","doi-asserted-by":"publisher","first-page":"109899","DOI":"10.1016\/j.apradiso.2021.109899","volume":"177","author":"N Tamam","year":"2021","unstructured":"Tamam N, Almuqrin AH, Mansour S, Elnour A, Musa M, Omer H, Sulieman A, Bradley DA (2021) Occupational and patients effective radiation doses in dental imaging. Appl Radiat Isot 177:109899","journal-title":"Appl Radiat Isot"},{"issue":"11","key":"1228_CR21","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1002\/acm2.13062","volume":"21","author":"S Taneja","year":"2020","unstructured":"Taneja S, Barbee DL, Rea AJ, Malin M (2020) CBCT image quality QA: Establishing a quantitative program. J Appl Clin Med Phys 21(11):215\u2013225","journal-title":"J Appl Clin Med Phys"},{"key":"1228_CR22","doi-asserted-by":"crossref","unstructured":"Tang K, Wang L, Li R, Lin J, Zheng X, Cao G (2012) Effect of Low Tube Voltage on Image Quality, Radiation Dose, and Low-Contrast Detectability at Abdominal Multidetector CT: Phantom Study, vol 2012. BioMed Research International, p 130169. 1","DOI":"10.1155\/2012\/130169"},{"issue":"1","key":"1228_CR23","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1007\/s11282-023-00705-7","volume":"40","author":"S Terashima","year":"2024","unstructured":"Terashima S, Sano J, Osanai M, Toshima K, Ohuchi K, Hosokawa Y (2024) Monte Carlo simulations of organ and effective doses and dose\u2013length product for dental cone-beam CT. Oral Radiol 40(1):37\u201348","journal-title":"Oral Radiol"},{"issue":"4","key":"1228_CR24","first-page":"320","volume":"9","author":"D Tun\u00e7man","year":"2023","unstructured":"Tun\u00e7man D, Kesmezacar FF, G\u00fcnay O, Yeyin N, Demir \u00d6, Demir M, Akku\u015f B (2023) Thermoluminescence Dosimeters Holder Cassette Design and 3D Printing. Int J Comput Experimental Sci Eng 9(4):320\u2013324","journal-title":"Int J Comput Experimental Sci Eng"},{"issue":"3","key":"1228_CR25","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1120\/jacmp.v10i3.2986","volume":"10","author":"JF Winslow","year":"2009","unstructured":"Winslow JF, Hyer DE, Fisher RF, Tien CJ, Hintenlang DE (2009) Construction of anthropomorphic phantoms for use in dosimetry studies. J Appl Clin Med Phys 10(3):195\u2013204","journal-title":"J Appl Clin Med Phys"},{"issue":"7","key":"1228_CR26","doi-asserted-by":"publisher","first-page":"2063","DOI":"10.1088\/0031-9155\/57\/7\/2063","volume":"57","author":"H Yan","year":"2012","unstructured":"Yan H, Cervino L, Jia X, Jiang SB (2012) A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CT. Phys Med Biol 57(7):2063\u20132080","journal-title":"Phys Med Biol"},{"issue":"Suppl 1","key":"1228_CR27","doi-asserted-by":"publisher","first-page":"S883","DOI":"10.4103\/jpbs.jpbs_1077_23","volume":"16","author":"MU Zaman","year":"2024","unstructured":"Zaman MU (2024) Comparing Radiation Doses in CBCT and Medical CT Imaging for Dental Applications. J Pharm Bioallied Sci 16(Suppl 1):S883\u2013S885","journal-title":"J Pharm Bioallied Sci"}],"container-title":["Radiation and Environmental Biophysics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00411-026-01228-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00411-026-01228-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00411-026-01228-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:17:33Z","timestamp":1787026653000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00411-026-01228-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,8]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["1228"],"URL":"https:\/\/doi.org\/10.1007\/s00411-026-01228-5","relation":{},"ISSN":["0301-634X","1432-2099"],"issn-type":[{"value":"0301-634X","type":"print"},{"value":"1432-2099","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,8]]},"assertion":[{"value":"27 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.","order":1,"name":"Ethics","label":"Conflict of interest","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This article does not contain any studies involving human participants or animals performed by any of the authors. All procedures were conducted using an anthropometric phantom and laboratory-based dosimetry equipment.","order":2,"name":"Ethics","label":"Ethical Approval","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. No human participants were involved in this study.","order":3,"name":"Ethics","label":"Informed Consent","group":{"name":"EthicsHeading","label":"Declarations"}}]}}