{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T20:45:24Z","timestamp":1792615524011,"version":"4.5.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiat Environ Biophys"],"published-print":{"date-parts":[[2026,11]]},"DOI":"10.1007\/s00411-026-01251-6","type":"journal-article","created":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T09:32:48Z","timestamp":1789723968000},"page":"1127-1138","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of X-ray image quality and scattered radiation among portable, mobile, and stationary X-ray machines"],"prefix":"10.1007","volume":"65","author":[{"given":"Wantanee","family":"Wannawong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kornkamon","family":"Chalermwiriyawat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sasikan","family":"Kaeoklang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5224-0645","authenticated-orcid":false,"given":"Panatsada","family":"Awikunprasert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kritsada","family":"Prasomsap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wasu","family":"Tanasoontrarat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pipu","family":"Tavornshevin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,18]]},"reference":[{"key":"1251_CR9","doi-asserted-by":"crossref","unstructured":"Aksoy ME, Akkur MEKE, Ucgul A, Basak M, Alaca H (2012) Evaluation and comparison of image quality for indirect flat panel systems with CsI and GOS scintillators. 2012 7th International Symposium on Health Informatics and Bioinformatics, Nevsehir, Turkey","DOI":"10.1109\/HIBIT.2012.6209043"},{"key":"1251_CR1","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/j.nima.2015.05.013","volume":"795","author":"D Bor","year":"2015","unstructured":"Bor D, Unal E, Uslu A (2015) Comparison of different phantoms used in digital diagnostic imaging. Nucl Instrum Methods Phys Res Sect A 795:160\u2013166. https:\/\/doi.org\/10.1016\/j.nima.2015.05.013","journal-title":"Nucl Instrum Methods Phys Res Sect A"},{"issue":"4","key":"1251_CR2","doi-asserted-by":"publisher","first-page":"e274832","DOI":"10.62691\/vmj.2025.274832","volume":"69","author":"K Chidtakhob","year":"2025","unstructured":"Chidtakhob K, Amnakmanee T, Laesan W, Awikunprasert P, Chusin T (2025) Scattered Radiation Dose and Safety Assessment from Mobile X-Ray Radiography: Radiation Assessment from Mobile X-ray Units. Vajira Med Journal: J Urban Med 69(4):e274832. https:\/\/doi.org\/10.62691\/vmj.2025.274832","journal-title":"Vajira Med Journal: J Urban Med"},{"key":"1251_CR3","unstructured":"European Commission (1996) European guidelines on quality criteria for diagnostic radiographic images. EUR 16260 EN)"},{"issue":"1","key":"1251_CR4","doi-asserted-by":"publisher","first-page":"9305","DOI":"10.1038\/s41598-025-94346-x","volume":"15","author":"P Giridharan","year":"2025","unstructured":"Giridharan P, Inbaraj LR, Frederick A, Selvaraju S, Ramraj B, Thiruvengadam K, Daniel BD, Padmapriyadarsini C (2025) Diagnostic accuracy of screening and diagnostic tests used in a state-wide tuberculosis prevalence survey in India. Sci Rep 15(1):9305. https:\/\/doi.org\/10.1038\/s41598-025-94346-x","journal-title":"Sci Rep"},{"issue":"6","key":"1251_CR5","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1097\/rli.0000000000000646","volume":"55","author":"T Gossye","year":"2020","unstructured":"Gossye T, Smeets PV, Achten E, Bacher K (2020) Impact of Software Parameter Settings on Image Quality of Virtual Grid Processed Radiography Images: A Contrast-Detail Phantom Study. Invest Radiol 55(6):374\u2013380. https:\/\/doi.org\/10.1097\/rli.0000000000000646","journal-title":"Invest Radiol"},{"key":"1251_CR6","unstructured":"IAEA (2007) Dosimetry in diagnostic radiology: An international code of practice (Technical Reports Series No. 457). International Atomic Energy Agency"},{"key":"1251_CR7","unstructured":"ICRP (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP 37 (2\u20134)"},{"issue":"23","key":"1251_CR8","doi-asserted-by":"publisher","first-page":"204","DOI":"10.4103\/ijmr.ijmr_845_22","volume":"157","author":"R Kamal","year":"2023","unstructured":"Kamal R, Singh M, Roy S, Adhikari T, Gupta AK, Singh H, Rao VV, Panda S, Khan AM, Bhargava B (2023) A comparison of the quality of images of chest X-ray between handheld portable digital X-ray & routinely used digital X-ray machine. Indian J Med Res 157(23):204\u2013210. https:\/\/doi.org\/10.4103\/ijmr.ijmr_845_22","journal-title":"Indian J Med Res"},{"key":"1251_CR10","doi-asserted-by":"publisher","unstructured":"Marshall NW, Vandenbroucke D, Cockmartin L, Wanninger F, Smet M, Feng Y, Ni Y, Bosmans H (2023) Seven general radiography x-ray detectors with pixel sizes ranging from 175 to 76\u00b5m: technical evaluation with the focus on orthopaedic imaging. Phys Med Biol 68(19). https:\/\/doi.org\/10.1088\/1361-6560\/acf642","DOI":"10.1088\/1361-6560\/acf642"},{"key":"1251_CR11","doi-asserted-by":"publisher","unstructured":"Otomo K, Inaba Y, Abe K, Onodera M, Suzuki T, Sota M, Haga Y, Suzuki M, Zuguchi M, Chida K (2023) Spatial Scattering Radiation to the Radiological Technologist during Medical Mobile Radiography. Bioeng (Basel) 10(2). https:\/\/doi.org\/10.3390\/bioengineering10020259","DOI":"10.3390\/bioengineering10020259"},{"issue":"1","key":"1251_CR12","doi-asserted-by":"publisher","first-page":"e0003986","DOI":"10.1371\/journal.pgph.0003986","volume":"5","author":"LE Paulis","year":"2025","unstructured":"Paulis LE, Schnerr RS, Halton J, Qin ZZ, Chua A (2025) Assessment of scattered and leakage radiation from ultra-portable X-ray systems in chest imaging: An independent study. PLOS Glob Public Health 5(1):e0003986. https:\/\/doi.org\/10.1371\/journal.pgph.0003986","journal-title":"PLOS Glob Public Health"},{"issue":"1","key":"1251_CR13","doi-asserted-by":"publisher","first-page":"14130","DOI":"10.1038\/s41598-021-93716-5","volume":"11","author":"AP Sauter","year":"2021","unstructured":"Sauter AP, Andrejewski J, Frank M, Willer K, Herzen J, Meurer F, Fingerle AA, Makowski MR, Pfeiffer F, Pfeiffer D (2021) Correlation of image quality parameters with tube voltage in X-ray dark-field chest radiography: a phantom study. Sci Rep 11(1):14130. https:\/\/doi.org\/10.1038\/s41598-021-93716-5","journal-title":"Sci Rep"},{"issue":"6","key":"1251_CR14","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.3201\/eid3006.231699","volume":"30","author":"Q Tan","year":"2024","unstructured":"Tan Q, Huang C-C, Becerra M, Calderon R, Contreras C, Lecca L, Jimenez J, Yataco R, Galea J, Feng J-Y, Pan S-W, Tseng Y-H, Huang J-R, Zhang Z, Murray M (2024) Chest Radiograph Screening for Detecting Subclinical Tuberculosis in Asymptomatic Household Contacts, Peru. Emerg Infect Disease J 30(6):1115. https:\/\/doi.org\/10.3201\/eid3006.231699","journal-title":"Emerg Infect Disease J"},{"key":"1251_CR15","doi-asserted-by":"publisher","unstructured":"Vo LNQ, Codlin A, Ngo TD, Dao TP, Dong TTT, Mo HTL, Forse R, Nguyen TT, Cung CV, Nguyen HB, Nguyen NV, Nguyen VV, Tran NT, Nguyen GH, Qin ZZ, Creswell J (2021) Early Evaluation of an Ultra-Portable X-ray System for Tuberculosis Active Case Finding. Trop Med Infect Dis 6(3). https:\/\/doi.org\/10.3390\/tropicalmed6030163","DOI":"10.3390\/tropicalmed6030163"},{"key":"1251_CR16","unstructured":"World Health Organization (2016) Chest radiography in tuberculosis detection: summary of current WHO recommendations and guidance on programmatic approaches. World Health Organization"},{"issue":"1","key":"1251_CR17","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s41479-024-00133-z","volume":"16","author":"J Yayan","year":"2024","unstructured":"Yayan J, Franke KJ, Berger M, Windisch W, Rasche K (2024) Early detection of tuberculosis: a systematic review. Pneumonia (Nathan) 16(1):11. https:\/\/doi.org\/10.1186\/s41479-024-00133-z","journal-title":"Pneumonia (Nathan)"}],"container-title":["Radiation and Environmental Biophysics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00411-026-01251-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00411-026-01251-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00411-026-01251-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T20:02:03Z","timestamp":1792612923000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00411-026-01251-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,18]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["1251"],"URL":"https:\/\/doi.org\/10.1007\/s00411-026-01251-6","relation":{},"ISSN":["0301-634X","1432-2099"],"issn-type":[{"value":"0301-634X","type":"print"},{"value":"1432-2099","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,18]]},"assertion":[{"value":"4 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}]}}