{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T14:03:32Z","timestamp":1788444212979,"version":"build-2803163510"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2019,6,15]],"date-time":"2019-06-15T00:00:00Z","timestamp":1560556800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,6,15]],"date-time":"2019-06-15T00:00:00Z","timestamp":1560556800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1007\/s00417-019-04395-y","type":"journal-article","created":{"date-parts":[[2019,6,15]],"date-time":"2019-06-15T15:02:37Z","timestamp":1560610957000},"page":"2015-2023","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Cryolite glass prosthetic eyes\u2014the response of the anophthalmic socket"],"prefix":"10.1007","volume":"257","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0224-3597","authenticated-orcid":false,"given":"Alexander C.","family":"Rokohl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Werner","family":"Adler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konrad R.","family":"Koch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel M.","family":"Mor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renbing","family":"Jia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Trester","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola S.","family":"Pine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keith R.","family":"Pine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ludwig M.","family":"Heindl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,6,15]]},"reference":[{"key":"4395_CR1","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1111\/j.1442-9071.2010.02381.x","volume":"39","author":"K Pine","year":"2011","unstructured":"Pine K, Sloan B, Stewart J, Jacobs RJ (2011) Concerns of anophthalmic patients wearing artificial eyes. Clin Exp Ophthalmol 39:47\u201352. \n                    https:\/\/doi.org\/10.1111\/j.1442-9071.2010.02381.x","journal-title":"Clin Exp Ophthalmol"},{"key":"4395_CR2","doi-asserted-by":"publisher","unstructured":"Rokohl AC, Koch KR, Trester M, Trester W, Pine KR, Heindl LM (2017) Concerns of Anophthalmic patients wearing Cryolite glass prosthetic eyes. Ophthal Plast Reconstr Surg. \n                    https:\/\/doi.org\/10.1097\/IOP.0000000000001021","DOI":"10.1097\/IOP.0000000000001021"},{"key":"4395_CR3","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1080\/01676830.2017.1337201","volume":"36","author":"NS Pine","year":"2017","unstructured":"Pine NS, de Terte I, Pine KR (2017) An investigation into discharge, visual perception, and appearance concerns of prosthetic eye wearers. Orbit 36:401\u2013406. \n                    https:\/\/doi.org\/10.1080\/01676830.2017.1337201","journal-title":"Orbit"},{"key":"4395_CR4","doi-asserted-by":"publisher","first-page":"465","DOI":"10.2147\/OPTH.S120653","volume":"11","author":"DL Mourits","year":"2017","unstructured":"Mourits DL, Hartong DT, Budding AE, Bosscha MI, Tan HS, Moll AC (2017) Discharge and infection in retinoblastoma post-enucleation sockets. Clin Ophthalmol 11:465\u2013472. \n                    https:\/\/doi.org\/10.2147\/OPTH.S120653","journal-title":"Clin Ophthalmol"},{"key":"4395_CR5","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1016\/j.mehy.2013.04.024","volume":"81","author":"KR Pine","year":"2013","unstructured":"Pine KR, Sloan BH, Jacobs RJ (2013) A proposed model of the response of the anophthalmic socket to prosthetic eye wear and its application to the management of mucoid discharge. Med Hypotheses 81:300\u2013305. \n                    https:\/\/doi.org\/10.1016\/j.mehy.2013.04.024","journal-title":"Med Hypotheses"},{"key":"4395_CR6","doi-asserted-by":"publisher","first-page":"1755","DOI":"10.2147\/OPTH.S37250","volume":"6","author":"KR Pine","year":"2012","unstructured":"Pine KR, Sloan B, Jacobs RJ (2012) Deposit buildup on prosthetic eyes and implications for conjunctival inflammation and mucoid discharge. Clin Ophthalmol 6:1755\u20131762. \n                    https:\/\/doi.org\/10.2147\/OPTH.S37250","journal-title":"Clin Ophthalmol"},{"key":"4395_CR7","doi-asserted-by":"publisher","unstructured":"Rokohl AC, Koch KR, Adler W, Trester M, Trester W, Pine NS, Pine KR, Heindl LM (2018) Concerns of anophthalmic patients-a comparison between cryolite glass and polymethyl methacrylate prosthetic eye wearers. Graefes Arch Clin Exp Ophthalmol. \n                    https:\/\/doi.org\/10.1007\/s00417-018-3942-8","DOI":"10.1007\/s00417-018-3942-8"},{"key":"4395_CR8","doi-asserted-by":"publisher","first-page":"1212","DOI":"10.1038\/eye.2014.174","volume":"28","author":"JW Han","year":"2014","unstructured":"Han JW, Yoon JS, Jang SY (2014) Short-term effects of topical cyclosporine a 0.05% (Restasis) in long-standing prosthetic eye wearers: a pilot study. Eye (Lond) 28:1212\u20131217. \n                    https:\/\/doi.org\/10.1038\/eye.2014.174","journal-title":"Eye (Lond)"},{"key":"4395_CR9","doi-asserted-by":"publisher","first-page":"707","DOI":"10.2147\/OPTH.S31126","volume":"6","author":"K Pine","year":"2012","unstructured":"Pine K, Sloan B, Stewart J, Jacobs RJ (2012) A survey of prosthetic eye wearers to investigate mucoid discharge. Clin Ophthalmol 6:707\u2013713. \n                    https:\/\/doi.org\/10.2147\/OPTH.S31126","journal-title":"Clin Ophthalmol"},{"key":"4395_CR10","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1097\/ICU.0000000000000069","volume":"25","author":"E Bohman","year":"2014","unstructured":"Bohman E, Roed Rassmusen ML, Kopp ED (2014) Pain and discomfort in the anophthalmic socket. Curr Opin Ophthalmol 25:455\u2013460. \n                    https:\/\/doi.org\/10.1097\/ICU.0000000000000069","journal-title":"Curr Opin Ophthalmol"},{"key":"4395_CR11","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.ajo.2016.02.016","volume":"165","author":"MB Kashkouli","year":"2016","unstructured":"Kashkouli MB, Zolfaghari R, Es'haghi A, Amirsardari A, Abtahi MB, Karimi N, Alemzadeh A, Aghamirsalim M (2016) Tear film, lacrimal drainage system, and eyelid findings in subjects with Anophthalmic socket discharge. Am J Ophthalmol 165:33\u201338. \n                    https:\/\/doi.org\/10.1016\/j.ajo.2016.02.016","journal-title":"Am J Ophthalmol"},{"key":"4395_CR12","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1111\/j.1444-0938.2012.00754.x","volume":"96","author":"KR Pine","year":"2013","unstructured":"Pine KR, Sloan B, Jacobs RJ (2013) The development of measurement tools for prosthetic eye research. Clin Exp Optom 96:32\u201338. \n                    https:\/\/doi.org\/10.1111\/j.1444-0938.2012.00754.x","journal-title":"Clin Exp Optom"},{"key":"4395_CR13","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1111\/cxo.12004","volume":"96","author":"KR Pine","year":"2013","unstructured":"Pine KR, Sloan B, Stewart J, Jacobs RJ (2013) The response of the anophthalmic socket to prosthetic eye wear. Clin Exp Optom 96:388\u2013393. \n                    https:\/\/doi.org\/10.1111\/cxo.12004","journal-title":"Clin Exp Optom"},{"key":"4395_CR14","doi-asserted-by":"publisher","unstructured":"Litwin AS, Worrell E, Roos JC, Edwards B, Malhotra R (2017) Can we improve the tolerance of an ocular prosthesis by enhancing its surface finish? Ophthal Plast Reconstr Surg. \n                    https:\/\/doi.org\/10.1097\/IOP.0000000000000891","DOI":"10.1097\/IOP.0000000000000891"},{"key":"4395_CR15","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1007\/s00417-017-3708-8","volume":"255","author":"A Toribio","year":"2017","unstructured":"Toribio A, Marrodan T, Fernandez-Natal I, Martinez-Blanco H, Rodriguez-Aparicio L, Ferrero MA (2017) Study of conjunctival flora in anophthalmic patients: influence on the comfort of the socket. Graefes Arch Clin Exp Ophthalmol 255:1669\u20131679. \n                    https:\/\/doi.org\/10.1007\/s00417-017-3708-8","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"Pt 3","key":"4395_CR16","first-page":"351","volume":"103","author":"CA Jones","year":"1983","unstructured":"Jones CA, Collin JR (1983) A classification and review the causes of discharging sockets. Trans Ophthalmol Soc U K 103(Pt 3):351\u2013353","journal-title":"Trans Ophthalmol Soc U K"},{"key":"4395_CR17","doi-asserted-by":"publisher","first-page":"313","DOI":"10.2147\/OPTH.S40680","volume":"7","author":"KR Pine","year":"2013","unstructured":"Pine KR, Sloan B, Han KI, Swift S, Jacobs RJ (2013) Deposit buildup on prosthetic eye material (in vitro) and its effect on surface wettability. Clin Ophthalmol 7:313\u2013319. \n                    https:\/\/doi.org\/10.2147\/OPTH.S40680","journal-title":"Clin Ophthalmol"},{"key":"4395_CR18","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1590\/S1678-77572007000100008","volume":"15","author":"RM Paranhos","year":"2007","unstructured":"Paranhos RM, Batalhao CH, Semprini M, Regalo SC, Ito IY, de Mattos Mda G (2007) Evaluation of ocular prosthesis biofilm and anophthalmic cavity contamination after use of three cleansing solutions. J Appl Oral Sci 15:33\u201338","journal-title":"J Appl Oral Sci"},{"key":"4395_CR19","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1111\/j.1755-3768.1974.tb01116.x","volume":"52","author":"JN Christensen","year":"1974","unstructured":"Christensen JN, Fahmy JA (1974) The bacterial flora of the conjunctival anophthalmic socket in glass prosthesis-carriers. Acta Ophthalmol 52:801\u2013809","journal-title":"Acta Ophthalmol"},{"key":"4395_CR20","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1111\/ceo.12514","volume":"43","author":"MT Sun","year":"2015","unstructured":"Sun MT, Pirbhai A, Selva D (2015) Bacterial biofilms associated with ocular prostheses. Clin Exp Ophthalmol 43:602\u2013603. \n                    https:\/\/doi.org\/10.1111\/ceo.12514","journal-title":"Clin Exp Ophthalmol"},{"key":"4395_CR21","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1055\/s-2008-1054613","volume":"185","author":"F H\u00e4rting","year":"1984","unstructured":"H\u00e4rting F, Fl\u00f6rke OW, Bornfeld N, Trester W (1984) Surface changes in glass eye prostheses. Klin Monatsbl Augenheilkd 185:272\u2013275. \n                    https:\/\/doi.org\/10.1055\/s-2008-1054613","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"4395_CR22","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1007\/s00347-015-0091-x","volume":"113","author":"KR Koch","year":"2016","unstructured":"Koch KR, Trester W, Muller-Uri N, Trester M, Cursiefen C, Heindl LM (2016) Ocular prosthetics. Fitting, daily use and complications. Ophthalmologe 113:133\u2013142. \n                    https:\/\/doi.org\/10.1007\/s00347-015-0091-x","journal-title":"Ophthalmologe"},{"key":"4395_CR23","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1016\/0002-9394(77)90137-4","volume":"83","author":"MR Allansmith","year":"1977","unstructured":"Allansmith MR, Korb DR, Greiner JV, Henriquez AS, Simon MA, Finnemore VM (1977) Giant papillary conjunctivitis in contact lens wearers. Am J Ophthalmol 83:697\u2013708","journal-title":"Am J Ophthalmol"},{"key":"4395_CR24","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1097\/00002341-198912000-00010","volume":"5","author":"RJ Vasquez","year":"1989","unstructured":"Vasquez RJ, Linberg JV (1989) The anophthalmic socket and the prosthetic eye. A clinical and bacteriologic study. Ophthal Plast Reconstr Surg 5:277\u2013280","journal-title":"Ophthal Plast Reconstr Surg"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-019-04395-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00417-019-04395-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-019-04395-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,13]],"date-time":"2020-06-13T23:07:05Z","timestamp":1592089625000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00417-019-04395-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,15]]},"references-count":24,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["4395"],"URL":"https:\/\/doi.org\/10.1007\/s00417-019-04395-y","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,15]]},"assertion":[{"value":"21 October 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2019","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2019","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2019","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Alexander C. Rokohl, Werner Adler, Konrad R. Koch, Joel M. Mor, Rening Jia, Nicola S. Pine, Keith R. Pine, and Ludwig M. Heindl certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge, or beliefs) in the subject matter or materials discussed in the manuscript. The participants in this study were recruited from the Trester-Institute for Ocular Prosthetics and Artificial Eyes in Cologne that is owned and operated by M. Trester. All authors have full control of all primary data and they agree to allow <i>Graefe\u2019s Archive for Clinical and Experimental Ophthalmology<\/i> to review their data upon request.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee of the University of Auckland and of the University of Cologne and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}