{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T14:52:23Z","timestamp":1792075943929,"version":"4.4.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2021,6,26]],"date-time":"2021-06-26T00:00:00Z","timestamp":1624665600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,6,26]],"date-time":"2021-06-26T00:00:00Z","timestamp":1624665600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100008349","name":"Universit\u00e4t Duisburg-Essen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100008349","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>A central diagnostic tool in adult glaucoma is the peripapillary retinal nerve fibre layer (pRNFL) thickness. It can be assessed by scanning laser polarimetry (SLP) or optical coherence tomography (OCT). However, studies investigating the relevance of pRNFL measurements in children are rare. This study aims to compare the glaucoma diagnosing ability of SLP and OCT pRNFL thickness measurements in a paediatric population.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This retrospective study included 105 children (glaucoma: 22 (21.0%); healthy glaucoma suspects: 83 (79.0%)) aged 4\u201318\u00a0years, examined with SLP (GDxPro\/ECC, Carl Zeiss Meditec) and spectral-domain OCT (SPECTRALIS\u00ae, Heidelberg Engineering). The thickness of pRNFL sectors was compared between diseased and healthy participants. Areas under the receiver-operating characteristic curves (AUC) and logistic regression results were used to compare the glaucoma discriminative capacity between SLP and OCT measurements.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Using OCT, pRNFL thickness was decreased in the superior, nasal, and inferior quadrants of glaucoma patients compared to healthy controls (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001, each). With SLP, such a difference was only observed in the inferior quadrant (<jats:italic>P<\/jats:italic>\u2009=\u20090.011). A correlation between glaucoma diagnosis and OCT-measured pRNFL thickness was found in all quadrants (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001) other than the temporal. With SLP, a correlation was found for the total average thickness (<jats:italic>P<\/jats:italic>\u2009=\u20090.037) and inferior quadrant (<jats:italic>P<\/jats:italic>\u2009=\u20090.0019). Finally, the AUCs of OCT measurements were markedly higher than those of SLP (e.g., inferior quadrant: OCT 0.83, SLP 0.68).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>pRNFL thickness measurements using both OCT and SLP, correlate notably with the presence of glaucoma. In general, the diagnostic performance of pRNFL thickness measurements seems higher for OCT than for SLP. Thus, pRNFL thickness measurements could provide important information, complementing conventional clinical and functional parameters in the diagnostic process of paediatric glaucoma.\n<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00417-021-05276-z","type":"journal-article","created":{"date-parts":[[2021,6,26]],"date-time":"2021-06-26T05:03:01Z","timestamp":1624683781000},"page":"3777-3786","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Retinal nerve fibre layer thickness measurements in childhood glaucoma: the role of scanning laser polarimetry and optical coherence tomography"],"prefix":"10.1007","volume":"259","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3244-6782","authenticated-orcid":false,"given":"Mael","family":"Lever","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Halfwassen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Darius","family":"Unterlauft","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikolaos E.","family":"Bechrakis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anke","family":"Manthey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael R. R.","family":"B\u00f6hm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,6,26]]},"reference":[{"key":"5276_CR1","doi-asserted-by":"publisher","first-page":"118","DOI":"10.4103\/0301-4738.179716","volume":"64","author":"A Hoguet","year":"2016","unstructured":"Hoguet A, Grajewski A, Hodapp E, Chang TCP (2016) A retrospective survey of childhood glaucoma prevalence according to Childhood Glaucoma Research Network classification. Indian J Ophthalmol 64:118\u2013123","journal-title":"Indian J Ophthalmol"},{"key":"5276_CR2","first-page":"260","volume-title":"The Epidemiology of Eye Disease","author":"C Gilbert","year":"2003","unstructured":"Gilbert C, Rahi J, Quinn G (2003) Visual impairment and blindness in children. In: Johnson G, Minassian D, Weale R, West S (eds) The Epidemiology of Eye Disease, 2nd edn. Edward Arnold Ltd., London, pp 260\u2013286","edition":"2"},{"key":"5276_CR3","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1097\/ICU.0000000000000516","volume":"29","author":"A Thau","year":"2018","unstructured":"Thau A, Lloyd M, Freedman S et al (2018) New classification system for pediatric glaucoma: implications for clinical care and a research registry. Curr Opin Ophthalmol 29:385\u2013394. https:\/\/doi.org\/10.1097\/ICU.0000000000000516","journal-title":"Curr Opin Ophthalmol"},{"key":"5276_CR4","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.spen.2017.04.008","volume":"24","author":"SM Gospe","year":"2017","unstructured":"Gospe SM, Bhatti MT, El-Dairi MA (2017) Emerging applications of optical coherence tomography in pediatric optic neuropathies. Semin Pediatr Neurol 24:135\u2013142. https:\/\/doi.org\/10.1016\/j.spen.2017.04.008","journal-title":"Semin Pediatr Neurol"},{"key":"5276_CR5","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2018-000194","volume":"4","author":"AV Pilat","year":"2019","unstructured":"Pilat AV, Shah S, Sheth V et al (2019) Detection and characterisation of optic nerve and retinal changes in primary congenital glaucoma using hand-held optical coherence tomography. BMJ Open Ophthalmol 4:e000194. https:\/\/doi.org\/10.1136\/bmjophth-2018-000194","journal-title":"BMJ Open Ophthalmol"},{"key":"5276_CR6","doi-asserted-by":"publisher","first-page":"1593","DOI":"10.1016\/j.ophtha.2006.06.004","volume":"113","author":"NN Shah","year":"2006","unstructured":"Shah NN, Bowd C, Medeiros FA et al (2006) Combining structural and functional testing for detection of glaucoma. Ophthalmology 113:1593\u20131602. https:\/\/doi.org\/10.1016\/j.ophtha.2006.06.004","journal-title":"Ophthalmology"},{"key":"5276_CR7","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1136\/bjophthalmol-2015-308199","volume":"100","author":"Q Zhang","year":"2016","unstructured":"Zhang Q, Qi Y, Chen L et al (2016) The relationship between anti-vascular endothelial growth factor and fibrosis in proliferative retinopathy: clinical and laboratory evidence. Br J Ophthalmol 100:1443\u20131450. https:\/\/doi.org\/10.1136\/bjophthalmol-2015-308199","journal-title":"Br J Ophthalmol"},{"key":"5276_CR8","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1001\/archopht.122.6.827","volume":"122","author":"FA Medeiros","year":"2004","unstructured":"Medeiros FA, Zangwill LM, Bowd C, Weinreb RN (2004) Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. Arch Ophthalmol 122:827\u2013837. https:\/\/doi.org\/10.1001\/archopht.122.6.827","journal-title":"Arch Ophthalmol"},{"key":"5276_CR9","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/00055735-199504000-00014","volume":"6","author":"JS Schuman","year":"1995","unstructured":"Schuman JS, Hee MR, Arya AV et al (1995) Optical coherence tomography: a new tool for glaucoma diagnosis. Curr Opin Ophthalmol 6:89\u201395. https:\/\/doi.org\/10.1097\/00055735-199504000-00014","journal-title":"Curr Opin Ophthalmol"},{"key":"5276_CR10","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1126\/science.1957169","volume":"119","author":"RN Weinreb","year":"1995","unstructured":"Weinreb RN, Shakiba S, Zangwill L (1995) Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol 119:627\u2013636. https:\/\/doi.org\/10.1126\/science.1957169","journal-title":"Am J Ophthalmol"},{"key":"5276_CR11","doi-asserted-by":"publisher","first-page":"3146","DOI":"10.1167\/iovs.06-1139","volume":"48","author":"FA Medeiros","year":"2007","unstructured":"Medeiros FA, Bowd C, Zangwill LM et al (2007) Detection of glaucoma using scanning laser polarimetry with enhanced corneal compensation. Investig Ophthalmol Vis Sci 48:3146\u20133153. https:\/\/doi.org\/10.1167\/iovs.06-1139","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"5276_CR12","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1097\/IJG.0000000000000833","volume":"27","author":"T Diekmann","year":"2018","unstructured":"Diekmann T, Schrems-Hoesl LM, Mardin CY et al (2018) Predictive factors for visual field conversion: comparison of scanning laser polarimetry and optical coherence tomography. J Glaucoma 27:157\u2013163. https:\/\/doi.org\/10.1097\/IJG.0000000000000833","journal-title":"J Glaucoma"},{"key":"5276_CR13","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2019-314795","author":"E Karvonen","year":"2019","unstructured":"Karvonen E, Stoor K, Luodonp\u00e4\u00e4 M et al (2019) Diagnostic performance of modern imaging instruments in glaucoma screening. Br J Ophthalmol. https:\/\/doi.org\/10.1136\/bjophthalmol-2019-314795","journal-title":"Br J Ophthalmol"},{"issue":"80","key":"5276_CR14","doi-asserted-by":"publisher","first-page":"1178","DOI":"10.1126\/science.1957169","volume":"254","author":"D Huang","year":"1991","unstructured":"Huang D, Swanson E, Lin C et al (1991) Optical coherence tomography. Science 254(80):1178\u20131181. https:\/\/doi.org\/10.1126\/science.1957169","journal-title":"Science"},{"key":"5276_CR15","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1136\/bjophthalmol-2012-302648","volume":"97","author":"FF Ghasia","year":"2013","unstructured":"Ghasia FF, Freedman SF, Rajani A et al (2013) Optical coherence tomography in paediatric glaucoma: time domain versus spectral domain. Br J Ophthalmol 97:837\u2013842. https:\/\/doi.org\/10.1136\/bjophthalmol-2012-302648","journal-title":"Br J Ophthalmol"},{"key":"5276_CR16","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1016\/j.ophtha.2016.02.017","volume":"123","author":"M Yu","year":"2016","unstructured":"Yu M, Lin C, Weinreb RN et al (2016) Risk of visual field progression in glaucoma patients with progressive retinal nerve fiber layer thinning a 5-year prospective study. Ophthalmology 123:1201\u20131210. https:\/\/doi.org\/10.1016\/j.ophtha.2016.02.017","journal-title":"Ophthalmology"},{"key":"5276_CR17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2019.05.012","author":"L Xu","year":"2019","unstructured":"Xu L, Freedman SF, Silverstein E et al (2019) Longitudinal reproducibility of spectral domain optical coherence tomography in children with physiologic cupping and stable glaucoma. J Am Assoc Pediatr Ophthalmol Strabismus. https:\/\/doi.org\/10.1016\/j.jaapos.2019.05.012","journal-title":"J Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"5276_CR18","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1097\/IJG.0b013e31829521db","volume":"24","author":"FF Ghasia","year":"2015","unstructured":"Ghasia FF, El-Dairi M, Freedman SF et al (2015) Reproducibility of spectral-domain optical coherence tomography measurements in adult and pediatric glaucoma. J Glaucoma 24:55\u201363. https:\/\/doi.org\/10.1097\/IJG.0b013e31829521db","journal-title":"J Glaucoma"},{"key":"5276_CR19","doi-asserted-by":"publisher","unstructured":"Michelessi M, Lucenteforte E, Oddone F, et al (2015) Optic nerve head and fibre layer imaging for diagnosing glaucoma. Cochrane Database Syst Rev 2015:. https:\/\/doi.org\/10.1002\/14651858.CD008803.pub2","DOI":"10.1002\/14651858.CD008803.pub2"},{"key":"5276_CR20","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1136\/bjo.2008.142562","volume":"93","author":"MA El-Dairi","year":"2009","unstructured":"El-Dairi MA, Holgado S, Asrani SG et al (2009) Correlation between optical coherence tomography and glaucomatous optic nerve head damage in children. Br J Ophthalmol 93:1325\u20131330. https:\/\/doi.org\/10.1136\/bjo.2008.142562","journal-title":"Br J Ophthalmol"},{"key":"5276_CR21","doi-asserted-by":"publisher","first-page":"2182","DOI":"10.1038\/eye.2009.15","volume":"23","author":"R Zareii","year":"2009","unstructured":"Zareii R, Soleimani M, Moghimi S et al (2009) Relationship between GDx VCC and stratus OCT in juvenile glaucoma. Eye 23:2182\u20132186. https:\/\/doi.org\/10.1038\/eye.2009.15","journal-title":"Eye"},{"key":"5276_CR22","first-page":"3","volume-title":"Childhood Glaucoma","author":"A Beck","year":"2013","unstructured":"Beck A, Chang T, Freedman S (2013) Definition, classification, differential diagnosis. In: Weinreb RN, Grajewski A, Papadopoulos M et al (eds) Childhood Glaucoma. Kugler Publications, Amsterdam, pp 3\u201310"},{"key":"5276_CR23","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1177\/1352458514538110","volume":"21","author":"S Schippling","year":"2015","unstructured":"Schippling S, Balk LJ, Costello F et al (2015) Quality control for retinal OCT in multiple sclerosis: validation of the OSCAR-IB criteria. Mult Scler 21:163\u2013170. https:\/\/doi.org\/10.1177\/1352458514538110","journal-title":"Mult Scler"},{"key":"5276_CR24","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.ajo.2017.09.020","volume":"184","author":"X Zhang","year":"2017","unstructured":"Zhang X, Dastiridou A, Francis BA et al (2017) Comparison of glaucoma progression detection by optical coherence tomography and visual field. Am J Ophthalmol 184:63\u201374. https:\/\/doi.org\/10.1016\/j.ajo.2017.09.020","journal-title":"Am J Ophthalmol"},{"key":"5276_CR25","doi-asserted-by":"publisher","first-page":"1343","DOI":"10.1007\/s00417-012-2219-x","volume":"251","author":"M Schallenberg","year":"2013","unstructured":"Schallenberg M, Dekowski D, Kremmer S et al (2013) Comparison of spectralis-OCT, GDxVCC and GDxECC in assessing retinal nerve fiber layer (RNFL) in glaucomatous patients. Graefe\u2019s Arch Clin Exp Ophthalmol 251:1343\u20131353. https:\/\/doi.org\/10.1007\/s00417-012-2219-x","journal-title":"Graefe\u2019s Arch Clin Exp Ophthalmol"},{"key":"5276_CR26","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1016\/j.ajo.2004.10.047","volume":"139","author":"DB Hess","year":"2005","unstructured":"Hess DB, Asrani SG, Bhide MG et al (2005) Macular and retinal nerve fiber layer analysis of normal and glaucomatous eyes in children using optical coherence tomography. Am J Ophthalmol 139:509\u2013517. https:\/\/doi.org\/10.1016\/j.ajo.2004.10.047","journal-title":"Am J Ophthalmol"},{"key":"5276_CR27","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1097\/IJG.0000000000000054","volume":"24","author":"A Schulze","year":"2015","unstructured":"Schulze A, Lamparter J, Pfeiffer N et al (2015) Comparison of laser scanning diagnostic devices for early glaucoma detection. J Glaucoma 24:442\u2013447. https:\/\/doi.org\/10.1097\/IJG.0000000000000054","journal-title":"J Glaucoma"},{"key":"5276_CR28","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1097\/IJG.0b013e3181a2fc0e","volume":"19","author":"WA Schrems","year":"2010","unstructured":"Schrems WA, Mardin CY, Horn FK et al (2010) Comparison of scanning laser polarimetry and optical coherence tomography in quantitative retinal nerve fiber assessment. J Glaucoma 19:83\u201394. https:\/\/doi.org\/10.1097\/IJG.0b013e3181a2fc0e","journal-title":"J Glaucoma"},{"key":"5276_CR29","doi-asserted-by":"publisher","first-page":"e105","DOI":"10.1111\/aos.12524","volume":"93","author":"HL Rao","year":"2015","unstructured":"Rao HL, Yadav RK, Begum VU et al (2015) Atypical birefringence pattern and the diagnostic ability of scanning laser polarimetry with enhanced corneal compensation in glaucoma. Acta Ophthalmol 93:e105\u2013e110. https:\/\/doi.org\/10.1111\/aos.12524","journal-title":"Acta Ophthalmol"},{"key":"5276_CR30","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1016\/J.AJO.2003.09.004","volume":"137","author":"K Nouri-Mahdavi","year":"2004","unstructured":"Nouri-Mahdavi K, Hoffman D, Tannenbaum DP et al (2004) Identifying early glaucoma with optical coherence tomography. Am J Ophthalmol 137:228\u2013235. https:\/\/doi.org\/10.1016\/J.AJO.2003.09.004","journal-title":"Am J Ophthalmol"},{"key":"5276_CR31","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1016\/S0161-6420(00)00168-8","volume":"107","author":"LM Zangwill","year":"2000","unstructured":"Zangwill LM, Williams J, Berry CC et al (2000) A comparison of optical coherence tomography and retinal nerve fiber layer photography for detection of nerve fiber layer damage in glaucoma. Ophthalmology 107:1309\u20131315. https:\/\/doi.org\/10.1016\/S0161-6420(00)00168-8","journal-title":"Ophthalmology"},{"key":"5276_CR32","doi-asserted-by":"publisher","first-page":"94.e1","DOI":"10.1016\/j.jaapos.2017.03.023","volume":"23","author":"L Perucho-Gonz\u00e1lez","year":"2019","unstructured":"Perucho-Gonz\u00e1lez L, Mart\u00ednez de la Casa JM, S\u00e1enz-Franc\u00e9s F et al (2019) Retinal nerve fiber layer thickness in children with primary congenital glaucoma measured by spectral domain optical coherence tomography. J Am Assoc Pediatr Ophthalmol Strabismus 23:94.e1-94.e4. https:\/\/doi.org\/10.1016\/j.jaapos.2017.03.023","journal-title":"J Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"5276_CR33","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1136\/bjophthalmol-2012-302486","volume":"98","author":"S Srinivasan","year":"2014","unstructured":"Srinivasan S, Addepalli UK, Rao HL et al (2014) Spectral domain optical coherence tomography in children operated for primary congenital glaucoma. Br J Ophthalmol 98:162\u2013165. https:\/\/doi.org\/10.1136\/bjophthalmol-2012-302486","journal-title":"Br J Ophthalmol"},{"key":"5276_CR34","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1111\/j.1600-0420.2006.00747.x","volume":"84","author":"P Brusini","year":"2006","unstructured":"Brusini P, Salvetat ML, Zeppieri M et al (2006) Comparison between GDx VCC scanning laser polarimetry and stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma. Acta Ophthalmol Scand 84:650\u2013655. https:\/\/doi.org\/10.1111\/j.1600-0420.2006.00747.x","journal-title":"Acta Ophthalmol Scand"},{"key":"5276_CR35","doi-asserted-by":"publisher","first-page":"1156","DOI":"10.1167\/iovs.06-0921","volume":"48","author":"JE DeLe\u00f3n Ortega","year":"2007","unstructured":"DeLe\u00f3n Ortega JE, Sakata LM, Kakati B et al (2007) Effect of glaucomatous damage on repeatability of confocal scanning laser ophthalmoscope, scanning laser polarimetry, and optical coherence tomography. Investig Ophthalmol Vis Sci 48:1156\u20131163. https:\/\/doi.org\/10.1167\/iovs.06-0921","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"5276_CR36","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1007\/s10384-010-0870-5","volume":"54","author":"S Lee","year":"2010","unstructured":"Lee S, Sung KR, Cho JW et al (2010) Spectral-domain optical coherence tomography and scanning laser polarimetry in glaucoma diagnosis. Jpn J Ophthalmol 54:544\u2013549. https:\/\/doi.org\/10.1007\/s10384-010-0870-5","journal-title":"Jpn J Ophthalmol"},{"key":"5276_CR37","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1016\/j.ophtha.2016.01.041","volume":"123","author":"K Banister","year":"2016","unstructured":"Banister K, Boachie C, Bourne R et al (2016) Can automated imaging for optic disc and retinal nerve fiber layer analysis aid glaucoma detection? Ophthalmology 123:930\u2013938. https:\/\/doi.org\/10.1016\/j.ophtha.2016.01.041","journal-title":"Ophthalmology"},{"key":"5276_CR38","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.jaapos.2016.05.013","volume":"20","author":"E Silverstein","year":"2016","unstructured":"Silverstein E, Freedman S, Z\u00e9hil G-PP et al (2016) The macula in pediatric glaucoma: quantifying the inner and outer layers via optical coherence tomography automatic segmentation. J AAPOS 20:332\u2013336. https:\/\/doi.org\/10.1016\/j.jaapos.2016.05.013","journal-title":"J AAPOS"},{"key":"5276_CR39","doi-asserted-by":"publisher","first-page":"260","DOI":"10.3390\/biology10040260","volume":"10","author":"M Lever","year":"2021","unstructured":"Lever M, Halfwassen C, Unterlauft JD et al (2021) The paediatric glaucoma diagnostic ability of optical coherence tomography: a comparison of macular segmentation and peripapillary retinal nerve fibre layer thickness. Biology (Basel) 10:260. https:\/\/doi.org\/10.3390\/biology10040260","journal-title":"Biology (Basel)"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-021-05276-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-021-05276-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-021-05276-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,12]],"date-time":"2021-11-12T09:17:41Z","timestamp":1636708661000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-021-05276-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6,26]]},"references-count":39,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["5276"],"URL":"https:\/\/doi.org\/10.1007\/s00417-021-05276-z","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,6,26]]},"assertion":[{"value":"27 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 April 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 June 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}