{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:22:25Z","timestamp":1786980145763,"version":"build-2736575974"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2021,7,21]],"date-time":"2021-07-21T00:00:00Z","timestamp":1626825600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,7,21]],"date-time":"2021-07-21T00:00:00Z","timestamp":1626825600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s00417-021-05309-7","type":"journal-article","created":{"date-parts":[[2021,7,21]],"date-time":"2021-07-21T06:04:02Z","timestamp":1626847442000},"page":"3729-3737","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Intraocular lens power calculation using adjusted corneal power in eyes with prior myopic laser vision correction"],"prefix":"10.1007","volume":"259","author":[{"given":"Jungah","family":"Huh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9475-4409","authenticated-orcid":false,"given":"Youngsub","family":"Eom","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eun Gyu","family":"Yoon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun-Heon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong Suk","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyo Myung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,7,21]]},"reference":[{"key":"5309_CR1","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/s12886-017-0439-x","volume":"17","author":"Y Wu","year":"2017","unstructured":"Wu Y, Liu S, Liao R (2017) Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery. BMC Ophthalmol 17:44","journal-title":"BMC Ophthalmol"},{"key":"5309_CR2","doi-asserted-by":"publisher","first-page":"2063","DOI":"10.1016\/S0886-3350(03)00957-X","volume":"29","author":"J Aramberri","year":"2003","unstructured":"Aramberri J (2003) Intraocular lens power calculation after corneal refractive surgery: double-K method. J Cataract Refract Surg 29:2063\u20132068","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR3","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.jcrs.2006.08.045","volume":"33","author":"HJ Shammas","year":"2007","unstructured":"Shammas HJ, Shammas MC (2007) No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis. J Cataract Refract Surg 33:31\u201336","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR4","doi-asserted-by":"publisher","first-page":"1658","DOI":"10.1016\/j.jcrs.2008.06.029","volume":"34","author":"W Haigis","year":"2008","unstructured":"Haigis W (2008) Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg 34:1658\u20131663","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR5","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40662-018-0110-5","volume":"5","author":"G Savini","year":"2018","unstructured":"Savini G, Hoffer KJ (2018) Intraocular lens power calculation in eyes with previous corneal refractive surgery. Eye Vision (London, England) 5:18","journal-title":"Eye Vision (London, England)"},{"key":"5309_CR6","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1136\/bjo.70.2.152","volume":"70","author":"T Olsen","year":"1986","unstructured":"Olsen T (1986) On the calculation of power from curvature of the cornea. Br J Ophthalmol 70:152\u2013154","journal-title":"Br J Ophthalmol"},{"key":"5309_CR7","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1167\/iovs.17-22405","volume":"59","author":"M Kim","year":"2018","unstructured":"Kim M, Eom Y, Lee H, Suh YW, Song JS, Kim HM (2018) Use of the posterior\/anterior corneal curvature radii ratio to improve the accuracy of intraocular lens power calculation: Eom\u2019s adjustment method. Invest Ophthalmol Vis Sci 59:1016\u20131024","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"5309_CR8","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/S0886-3350(98)80201-0","volume":"24","author":"PG Gobbi","year":"1998","unstructured":"Gobbi PG, Carones F, Brancato R (1998) Keratometric index, videokeratography, and refractive surgery. J Cataract Refract Surg 24:202\u2013211","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR9","doi-asserted-by":"publisher","first-page":"125","DOI":"10.3928\/1081-597X-19940301-11","volume":"10","author":"RB Mandell","year":"1994","unstructured":"Mandell RB (1994) Corneal power correction factor for photorefractive keratectomy. J Refract Corneal Surg 10:125\u2013128","journal-title":"J Refract Corneal Surg"},{"key":"5309_CR10","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1016\/j.jcrs.2005.12.106","volume":"32","author":"S Masket","year":"2006","unstructured":"Masket S, Masket SE (2006) Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation. J Cataract Refract Surg 32:430\u2013434","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR11","doi-asserted-by":"publisher","first-page":"2443","DOI":"10.1016\/j.ophtha.2015.08.037","volume":"122","author":"L Wang","year":"2015","unstructured":"Wang L, Tang M, Huang D, Weikert MP, Koch DD (2015) Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery. Ophthalmology 122:2443\u20132449","journal-title":"Ophthalmology"},{"key":"5309_CR12","doi-asserted-by":"publisher","first-page":"430","DOI":"10.3928\/1081597X-20090710-02","volume":"26","author":"M Tang","year":"2010","unstructured":"Tang M, Li Y, Huang D (2010) An intraocular lens power calculation formula based on optical coherence tomography: a pilot study. J Refract Surg 26:430\u2013437","journal-title":"J Refract Surg"},{"key":"5309_CR13","doi-asserted-by":"publisher","first-page":"888","DOI":"10.3928\/1081-597X-20071101-04","volume":"23","author":"SW Kim","year":"2007","unstructured":"Kim SW, Byun YJ, Kim EK, Kim TI (2007) Central corneal thickness measurements in unoperated eyes and eyes after PRK for myopia using Pentacam, Orbscan II, and ultrasonic pachymetry. J Refract Surg 23:888\u2013894","journal-title":"J Refract Surg"},{"key":"5309_CR14","doi-asserted-by":"publisher","first-page":"1825","DOI":"10.1016\/j.ophtha.2004.04.022","volume":"111","author":"L Wang","year":"2004","unstructured":"Wang L, Booth MA, Koch DD (2004) Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. Ophthalmology 111:1825\u20131831","journal-title":"Ophthalmology"},{"key":"5309_CR15","doi-asserted-by":"publisher","first-page":"1198","DOI":"10.1016\/j.jcrs.2009.02.030","volume":"35","author":"Q Tang","year":"2009","unstructured":"Tang Q, Hoffer KJ, Olson MD, Miller KM (2009) Accuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery. J Cataract Refract Surg 35:1198\u20131203","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR16","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1016\/j.ajo.2015.07.011","volume":"160","author":"Y Eom","year":"2015","unstructured":"Eom Y, Rhim JW, Kang SY, Kim SW, Song JS, Kim HM (2015) Toric intraocular lens calculations using ratio of anterior to posterior corneal cylinder power. Am J Ophthalmol 160:717-724.e712","journal-title":"Am J Ophthalmol"},{"key":"5309_CR17","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1016\/j.jcrs.2007.01.010","volume":"33","author":"AR Vasavada","year":"2007","unstructured":"Vasavada AR, Praveen MR, Pandita D, Gajjar DU, Vasavada VA, Vasavada VA, Raj SM, Johar K (2007) Effect of stromal hydration of clear corneal incisions: quantifying ingress of trypan blue into the anterior chamber after phacoemulsification. J Cataract Refract Surg 33:623\u2013627","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR18","doi-asserted-by":"publisher","first-page":"2018","DOI":"10.1016\/j.jcrs.2011.05.042","volume":"37","author":"L Wang","year":"2011","unstructured":"Wang L, Shirayama M, Ma XJ, Kohnen T, Koch DD (2011) Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm. J Cataract Refract Surg 37:2018\u20132027","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR19","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.ophtha.2017.08.027","volume":"125","author":"RB Melles","year":"2018","unstructured":"Melles RB, Holladay JT, Chang WJ (2018) Accuracy of intraocular lens calculation formulas. Ophthalmology 125:169\u2013178","journal-title":"Ophthalmology"},{"key":"5309_CR20","unstructured":"Hill W, Wang L, Koch DD IOL Calculator for eyes with prior myopic LASIK\/PRK. Available at https:\/\/iolcalc.ascrs.org\/wbfrmCalculator.aspx. Accessed Jan 3, 2021"},{"key":"5309_CR21","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1016\/j.jcrs.2015.09.024","volume":"42","author":"AK Schuster","year":"2016","unstructured":"Schuster AK, Schanzlin DJ, Thomas KE, Heichel CW, Purcell TL, Barker PD (2016) Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging. J Cataract Refract Surg 42:226\u2013231","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR22","doi-asserted-by":"publisher","first-page":"2645","DOI":"10.1038\/s41598-020-59487-1","volume":"10","author":"H Chen","year":"2020","unstructured":"Chen H, Chen X, Wang H, Fang Z, Yao K (2020) Intraocular Lens power calculation after laser refractive surgery: a meta-analysis. Sci Rep 10:2645","journal-title":"Sci Rep"},{"key":"5309_CR23","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1186\/s40662-020-00188-1","volume":"7","author":"H Li","year":"2020","unstructured":"Li H, Nan L, Li J, Song H (2020) Accuracy of intraocular lens power calculation formulae after laser refractive surgery in myopic eyes: a meta-analysis. Eye Vision (London, England) 7:37","journal-title":"Eye Vision (London, England)"},{"key":"5309_CR24","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1111\/ceo.13760","volume":"48","author":"M Lawless","year":"2020","unstructured":"Lawless M, Jiang JY, Hodge C, Sutton G, Roberts TV, Barrett G (2020) Total keratometry in intraocular lens power calculations in eyes with previous laser refractive surgery. Clin Exp Ophthalmol 48:749\u2013756","journal-title":"Clin Exp Ophthalmol"},{"key":"5309_CR25","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.jcrs.2015.11.039","volume":"42","author":"A Abulafia","year":"2016","unstructured":"Abulafia A, Hill WE, Koch DD, Wang L, Barrett GD (2016) Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia. J Cataract Refract Surg 42:363\u2013369","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR26","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1097\/j.jcrs.0000000000000472","volume":"47","author":"HP Sandoval","year":"2021","unstructured":"Sandoval HP, Serels C, Potvin R, Solomon KD (2021) Cataract surgery after myopic laser in situ keratomileusis: objective analysis to determine best formula and keratometry to use. J Cataract Refract Surg 47:465\u2013470","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR27","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1016\/S0002-9394(03)00275-7","volume":"136","author":"HJ Shammas","year":"2003","unstructured":"Shammas HJ, Shammas MC, Garabet A, Kim JH, Shammas A, LaBree L (2003) Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol 136:426\u2013432","journal-title":"Am J Ophthalmol"},{"key":"5309_CR28","doi-asserted-by":"publisher","first-page":"1880","DOI":"10.1016\/j.jcrs.2015.10.026","volume":"41","author":"G Savini","year":"2015","unstructured":"Savini G, Barboni P, Carbonelli M, Ducoli P, Hoffer KJ (2015) Intraocular lens power calculation after myopic excimer laser surgery: selecting the best method using available clinical data. J Cataract Refract Surg 41:1880\u20131888","journal-title":"J Cataract Refract Surg"},{"key":"5309_CR29","doi-asserted-by":"publisher","first-page":"2100","DOI":"10.1016\/j.ophtha.2007.05.049","volume":"114","author":"G Mu\u00f1oz","year":"2007","unstructured":"Mu\u00f1oz G, Albarr\u00e1n-Diego C, Sakla HF (2007) Autorefraction after multifocal IOLs. Ophthalmology 114:2100","journal-title":"Ophthalmology"},{"key":"5309_CR30","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1111\/aos.12410","volume":"92","author":"JW van der Linden","year":"2014","unstructured":"van der Linden JW, Vrijman V, Al-Saady R, van der Meulen IJ, Mourits MP, Lapid-Gortzak R (2014) Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens. Acta Ophthalmol 92:764\u2013768","journal-title":"Acta Ophthalmol"},{"key":"5309_CR31","doi-asserted-by":"publisher","first-page":"740","DOI":"10.3928\/1081597X-20200828-02","volume":"36","author":"Y Eom","year":"2020","unstructured":"Eom Y, Yang SK, Yoon EG, Choi JN, Ryu D, Kim DW, Kim JH, Song JS, Kim SW, Kim HM (2020) Multizonal design multifocal intraocular lens-induced astigmatism according to orientation. J Refract Surg 36:740\u2013748","journal-title":"J Refract Surg"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-021-05309-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-021-05309-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-021-05309-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,12]],"date-time":"2021-11-12T04:18:36Z","timestamp":1636690716000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-021-05309-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,21]]},"references-count":31,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["5309"],"URL":"https:\/\/doi.org\/10.1007\/s00417-021-05309-7","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,21]]},"assertion":[{"value":"7 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the Public Institutional Bioethics Committee (no. P01-202001\u201321-004) and the Institutional Review Board of Korea University Ansan Hospital (IRB no. 2019AS0213) and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. According to the IRB standard operating procedures on retrospective clinical study, the Ethics Committee ruled that subject consent was not required for this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements) or non-financial interest (such as personal or professional relationships, affiliations, knowledge, or beliefs) in the subject matter or materials discussed in this manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}