{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T05:21:52Z","timestamp":1791436912973,"version":"4.3.3"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T00:00:00Z","timestamp":1653609600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T00:00:00Z","timestamp":1653609600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100013968","name":"Johnson and Johnson Vision Care","doi-asserted-by":"publisher","award":["EMEA201906"],"award-info":[{"award-number":["EMEA201906"]}],"id":[{"id":"10.13039\/100013968","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Universitat de Valencia"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2022,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Intraocular lens designs are constantly evolving, trying to obtain more spectacle independence after cataract surgery. This advantage can be linked to some disadvantages, such as optical quality decrease. For that reason, it is important to assess, not only the amount of vision provided but also the quality of vision once they are implanted. The purpose of the present work was to compare the visual performance between two monofocal intraocular models: a standard model and a monofocal with enhanced intermediate vision lens.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Prospective, randomized, comparative study. Sixty adult subjects scheduled to undergo bilateral cataract surgery and IOL implantation were randomized to receive one of the two IOLs in both eyes at Miranza IOA, Madrid, Spain (group A: monofocal with enhanced intermediate vision lens and group B: standard monofocal lens). Monocular outcomes (right eyes) determined 1 and 3\u00a0months postoperatively were photopic corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), perceived halo, corrected intermediate-distance contrast sensitivity, and higher-order aberrations. The impact of the new IOL in the postoperative management with autorefraction devices was also evaluated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>No differences were found in CDVA between the two groups. Significant differences were detected between the two lenses evaluated in both total HOA (<jats:italic>p<\/jats:italic>\u2009=\u20090.028) and internal HOA (<jats:italic>p<\/jats:italic>\u2009=\u20090.037). Contrast sensitivity and halometry results obtained at 1\u00a0month were similar across the two IOL groups.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>In patients undergoing cataract surgery, monofocal with enhanced intermediate vision IOL offered similar distance performance and contrast sensitivity along with perceived HOA and halos compared with the standard monofocal IOLs tested.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00417-022-05700-y","type":"journal-article","created":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T08:03:54Z","timestamp":1653638634000},"page":"3617-3625","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Visual and optical quality of enhanced intermediate monofocal versus standard monofocal intraocular lens"],"prefix":"10.1007","volume":"260","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6162-0081","authenticated-orcid":false,"given":"Nuria","family":"Garz\u00f3n","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Poyales","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8972-1784","authenticated-orcid":false,"given":"C\u00e9sar","family":"Albarr\u00e1n-Diego","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6801-233X","authenticated-orcid":false,"given":"Laura","family":"Rico-del-Viejo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lidia","family":"P\u00e9rez-Sanz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9753-1411","authenticated-orcid":false,"given":"Mar\u00eda","family":"Garc\u00eda-Montero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,5,27]]},"reference":[{"key":"5700_CR1","doi-asserted-by":"publisher","first-page":"228","DOI":"10.3928\/1081597X-20180125-01","volume":"34","author":"G Savini","year":"2018","unstructured":"Savini G, Schiano-Lomoriello D, Balducci N et al (2018) Visual performance of a new extended depth-of-focus intraocular lens compared to a distance-dominant diffractive multifocal intraocular lens. J Refract Surg 34:228\u2013235","journal-title":"J Refract Surg"},{"key":"5700_CR2","doi-asserted-by":"publisher","first-page":"e164","DOI":"10.1016\/j.ophtha.2020.09.026","volume":"128","author":"R Rampat","year":"2020","unstructured":"Rampat R, Gatinel D (2020) Multifocal and EDOF intraocular lenses in 2020. Ophthalmology 128:e164\u2013e185. https:\/\/doi.org\/10.1016\/j.ophtha.2020.09.026","journal-title":"Ophthalmology"},{"key":"5700_CR3","unstructured":"Johnson& Johnson& Vision (2019) Delivering intermediate vision: the new TECNIS Eyhance Monofocal IOL. The Ophthalmologist. Available at: https:\/\/theophthalmologist.com\/subspecialties\/delivering-intermediate-vision-the-new-tecnis-eyhance-monofocal-iol"},{"key":"5700_CR4","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1016\/j.jcrs.2004.08.049","volume":"31","author":"R Bellucci","year":"2005","unstructured":"Bellucci R, Scialdone A, Buratto L et al (2005) Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study. J Cataract Refract Surg 31:712\u2013717","journal-title":"J Cataract Refract Surg"},{"key":"5700_CR5","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1136\/bjo.82.8.971","volume":"82","author":"IE Murdoch","year":"1998","unstructured":"Murdoch IE, Morris SS, Cousens SN (1998) People and eyes: statistical approaches in ophthalmology. Br J Ophthalmol 82:971\u2013973","journal-title":"Br J Ophthalmol"},{"issue":"Suppl 1","key":"5700_CR6","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1186\/1742-4682-11-s1-s1","volume":"11","author":"JJ Castro","year":"2014","unstructured":"Castro JJ, Ortiz C, Pozo AM et al (2014) A visual test based on a freeware software for quantifying and displaying night-vision disturbances: study in subjects after alcohol consumption. Theor Biol Med Model 11(Suppl 1):S1. https:\/\/doi.org\/10.1186\/1742-4682-11-s1-s1","journal-title":"Theor Biol Med Model"},{"key":"5700_CR7","doi-asserted-by":"publisher","first-page":"015001","DOI":"10.1117\/1.3526702","volume":"16","author":"JJ Castro","year":"2011","unstructured":"Castro JJ, Jimenez JR, Ortiz C et al (2011) New testing software for quantifying discrimination capacity in subjects with ocular pathologies. J Biomed Opt 16:015001. https:\/\/doi.org\/10.1117\/1.3526702","journal-title":"J Biomed Opt"},{"key":"5700_CR8","doi-asserted-by":"publisher","first-page":"1265","DOI":"10.1016\/j.jcrs.2019.04.017","volume":"45","author":"N Garzon","year":"2019","unstructured":"Garzon N, Garcia-Montero M, Lopez-Artero E et al (2019) Influence of trifocal intraocular lenses on standard autorefraction and aberrometer-based autorefraction. J Cataract Refract Surg 45:1265\u20131274","journal-title":"J Cataract Refract Surg"},{"key":"5700_CR9","first-page":"27","volume-title":"Astigmatism: Types","author":"V Mic\u00f3","year":"2014","unstructured":"Mic\u00f3 V, Albarr\u00e1n-Diego C, Thibos L (2014) Power vectors for the management of astigmatism: from theoretical to clinical applications. In: Buckley R (ed) Astigmatism: Types. Nova Science Publishers New York, Diagnosis and Treatment Option, pp 27\u201380"},{"key":"5700_CR10","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1097\/j.jcrs.0000000000000061","volume":"46","author":"R Mencucci","year":"2020","unstructured":"Mencucci R, Cennamo M, Venturi D et al (2020) Visual outcome, optical quality, and patient satisfaction with a new monofocal IOL, enhanced for intermediate vision: preliminary results. J Cataract Refract Surg 46:378\u2013387","journal-title":"J Cataract Refract Surg"},{"key":"5700_CR11","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1097\/j.jcrs.0000000000000399","volume":"47","author":"GU Auffarth","year":"2020","unstructured":"Auffarth GU, Gerl M, Tsai L et al (2020) Clinical evaluation of a new monofocal intraocular lens with enhanced intermediate function in cataract patients. J Cataract Refract Surg 47:184\u2013191","journal-title":"J Cataract Refract Surg"},{"key":"5700_CR12","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1097\/j.jcrs.0000000000000215","volume":"46","author":"D Tognetto","year":"2020","unstructured":"Tognetto D, Cecchini P, Giglio R et al (2020) Surface profiles of new-generation IOLs with improved intermediate vision. J Cataract Refract Surg 46:902\u2013906","journal-title":"J Cataract Refract Surg"},{"key":"5700_CR13","doi-asserted-by":"publisher","first-page":"625","DOI":"10.3928\/1081597X-20200710-01","volume":"36","author":"F Vega","year":"2020","unstructured":"Vega F, Millan MS, Gil MA et al (2020) (2020) Optical performance of a monofocal intraocular lens designed to extend depth of focus. J Refract Surg 36:625\u2013632","journal-title":"J Refract Surg"},{"key":"5700_CR14","doi-asserted-by":"publisher","first-page":"520","DOI":"10.3928\/1081597X-20200612-01","volume":"36","author":"A Alarcon","year":"2020","unstructured":"Alarcon A, Canovas C, Koopman B et al (2020) Enhancing the intermediate vision of monofocal intraocular lenses using a higher order aspheric optic. J Refract Surg 36:520\u2013527","journal-title":"J Refract Surg"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-022-05700-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-022-05700-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-022-05700-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,19]],"date-time":"2022-10-19T18:05:10Z","timestamp":1666202710000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-022-05700-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,27]]},"references-count":14,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2022,11]]}},"alternative-id":["5700"],"URL":"https:\/\/doi.org\/10.1007\/s00417-022-05700-y","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,27]]},"assertion":[{"value":"13 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2022","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 May 2022","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Authors Francisco Poyales and Nuria Garz\u00f3n have received an unrestricted research grant for an independent investigator study (IIS) (EMEA201906) from Johnson and Johnson Vision. The rest of authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in the present study involving human participants were in accordance with the ethical standards of the Ethic Committee of the Hospital Cl\u00ednico San Carlos (Madrid, Spain), and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}