{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T22:49:48Z","timestamp":1788648588083,"version":"build-2803163510"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,1,11]],"date-time":"2024-01-11T00:00:00Z","timestamp":1704931200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,1,11]],"date-time":"2024-01-11T00:00:00Z","timestamp":1704931200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1007\/s00417-023-06354-0","type":"journal-article","created":{"date-parts":[[2024,1,11]],"date-time":"2024-01-11T11:02:51Z","timestamp":1704970971000},"page":"1857-1863","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of central corneal thickness measured by automatic and manual analysis of optical coherence tomography"],"prefix":"10.1007","volume":"262","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1885-7099","authenticated-orcid":false,"given":"Carlo","family":"Bruttini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto","family":"Esposti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfredo","family":"Pece","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulio","family":"Maione","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Cavallari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,11]]},"reference":[{"key":"6354_CR1","doi-asserted-by":"publisher","first-page":"923","DOI":"10.3109\/02713683.2015.1082188","volume":"41","author":"J Cui","year":"2016","unstructured":"Cui J, Zhang X, Hu Q, Zhou WY, Yang F (2016) Evaluation of corneal thickness and volume parameters of subclinical keratoconus using a Pentacam Scheimflug System. Curr Eye Res 41:923\u2013926. https:\/\/doi.org\/10.3109\/02713683.2015.1082188","journal-title":"Curr Eye Res"},{"key":"6354_CR2","doi-asserted-by":"publisher","first-page":"1220","DOI":"10.1016\/j.ophtha.2009.10.027","volume":"117","author":"MA Shousha","year":"2010","unstructured":"Shousha MA, Perez VL, Wang J, Ide T, Jiao S, Chen Q, Chang V, Buchser N, Dubovy SR, Feuer W, Yoo SH (2010) Use of ultra-high-resolution optical coherence tomography to detect in vivo characteristics of Descemet\u2019s Membrane in Fuchs\u2019 Dystrophy. Ophthalmology 117:1220\u20131227. https:\/\/doi.org\/10.1016\/j.ophtha.2009.10.027","journal-title":"Ophthalmology"},{"key":"6354_CR3","doi-asserted-by":"publisher","first-page":"1102","DOI":"10.1016\/j.ophtha.2011.12.002","volume":"19","author":"T Hillenaar","year":"2012","unstructured":"Hillenaar T, Van Cleynenbreugel H, Verjans GM, Wubbels RJ, Remeijer L (2012) Monitoring the inflammatory process in herpetic stromal keratitis: the role of in vivo confocal microscopy. Ophthalmology 19:1102\u20131110. https:\/\/doi.org\/10.1016\/j.ophtha.2011.12.002","journal-title":"Ophthalmology"},{"key":"6354_CR4","doi-asserted-by":"publisher","first-page":"S72","DOI":"10.1016\/j.ophtha.2020.01.028","volume":"127","author":"JD Brandt","year":"2020","unstructured":"Brandt JD, Beiser JA, Kass MA, Gordon MO (2020) Ocular Hypertension Treatment Study (OHTS) Group. Central Corneal Thickness in the Ocular Hypertension Treatment Study (OHTS). Ophthalmology 127:S72\u2013S81. https:\/\/doi.org\/10.1016\/j.ophtha.2020.01.028","journal-title":"Ophthalmology"},{"key":"6354_CR5","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1136\/bjo.2003.023416","volume":"88","author":"S Miglior","year":"2004","unstructured":"Miglior S, Albe E, Guareschi M, Mandelli G, Gomarasca S, Orzalesi N (2004) Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness. Br J Ophthalmol 88:174\u2013177. https:\/\/doi.org\/10.1136\/bjo.2003.023416","journal-title":"Br J Ophthalmol"},{"issue":"1","key":"6354_CR6","doi-asserted-by":"publisher","first-page":"4","DOI":"10.4103\/2008-322X.156084","volume":"10","author":"MM Sadoughi","year":"2015","unstructured":"Sadoughi MM, Einollahi B, Einollahi N, Rezaei J, Roshandel D, Feizi S (2015) Measurement of central corneal thickness using ultrasound pachymetry and Orbscan II in normal eyes. J Ophthalmic Vis Res 10(1):4\u20139. https:\/\/doi.org\/10.4103\/2008-322X.156084","journal-title":"J Ophthalmic Vis Res"},{"key":"6354_CR7","doi-asserted-by":"publisher","first-page":"e102","DOI":"10.1097\/ICO.0b013e318275e7a6","volume":"32","author":"JA Sanchis-Gimeno","year":"2013","unstructured":"Sanchis-Gimeno JA, Palanca-Sanfrancisco JM, Garc\u00eda-L\u00e1zaro S, Madrid-Costa D, Cervi\u00f1o A (2013) The effect of anesthetic eye drop instillation on the distribution of corneal thickness. Cornea 32:e102\u2013e105. https:\/\/doi.org\/10.1097\/ICO.0b013e318275e7a6","journal-title":"Cornea"},{"key":"6354_CR8","doi-asserted-by":"publisher","first-page":"1842","DOI":"10.1016\/j.ophtha.2007.02.017","volume":"114","author":"EY Li","year":"2007","unstructured":"Li EY, Mohamed S, Leung CK, Rao SK, Cheng AC, Cheung CY, Lam DS (2007) Agreement among 3 methods to measure corneal thickness: ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography. Ophthalmology 114:1842\u20131847. https:\/\/doi.org\/10.1016\/j.ophtha.2007.02.017","journal-title":"Ophthalmology"},{"key":"6354_CR9","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1097\/00003226-200101000-00010","volume":"20","author":"M Bechmann","year":"2001","unstructured":"Bechmann M, Thiel M, Naubauer A, Ullrich S, Ludwig K, Kenyon KR, Ulbig MW (2001) Central corneal thickness measurement with a retinal optical coherence tomography device versus standard Ultrasound Pachymetry. Cornea 20:50\u201354. https:\/\/doi.org\/10.1097\/00003226-200101000-00010","journal-title":"Cornea"},{"key":"6354_CR10","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1111\/cxo.12013","volume":"96","author":"M Wells","year":"2013","unstructured":"Wells M, Wu N, Kokkinakis J, Sutton G (2013) Correlation of central corneal thickness measurements using Topcon TRK-1P, Zeiss Visnte AS-OCT and DGH Pachmate 55 handheld ultrasonic pachymeter. Clin Exp Optom 96:385\u2013387. https:\/\/doi.org\/10.1111\/cxo.12013","journal-title":"Clin Exp Optom"},{"key":"6354_CR11","doi-asserted-by":"publisher","first-page":"860","DOI":"10.1097\/IJG.0000000000000745","volume":"26","author":"R Scotto","year":"2017","unstructured":"Scotto R, Bagnis A, Papadia M, Cutolo CA, Risso D, Traverso CE (2017) Comparison of central corneal thickness measurements using ultrasonic pachymetry, anterior segment OCT and noncontact specular microscopy. J Glaucoma 26:860\u2013865. https:\/\/doi.org\/10.1097\/IJG.0000000000000745","journal-title":"J Glaucoma"},{"key":"6354_CR12","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.2147\/OPTH.S81376","volume":"9","author":"W Khaja","year":"2015","unstructured":"Khaja W, Grover S, Kelmenson A, Ferguson LR, Sambhav K, Chalam KV (2015) Comparison of central corneal thickness: ultrasound pachymetry versus slit-lamp coherence tomography, specular microscopy, and Orbscan. Clin Ophthalmol 9:1065\u20131070. https:\/\/doi.org\/10.2147\/OPTH.S81376","journal-title":"Clin Ophthalmol"},{"issue":"37","key":"6354_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4103\/sjopt.sjopt_63_20","volume":"9","author":"T Artu\u00e7","year":"2023","unstructured":"Artu\u00e7 T, Batur M (2023) Comparison of central corneal thickness in corneal edema by ultrasound pachymetry, specular microscopy, and anterior segment optical coherence tomography. Saudi J Ophthalmol 9(37):1\u20135. https:\/\/doi.org\/10.4103\/sjopt.sjopt_63_20","journal-title":"Saudi J Ophthalmol"},{"key":"6354_CR14","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1186\/s12886-015-0116-x","volume":"15","author":"M Ayala","year":"2015","unstructured":"Ayala M, Strandas R (2015) Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients. BMC Ophthalmol 15:124. https:\/\/doi.org\/10.1186\/s12886-015-0116-x","journal-title":"BMC Ophthalmol"},{"key":"6354_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0014-4835(73)90183-8","volume":"15","author":"K Yoshizo","year":"1973","unstructured":"Yoshizo K (1973) Diurnal variation in corneal thickness. Exp Eye Res 15:1\u20139. https:\/\/doi.org\/10.1016\/0014-4835(73)90183-8","journal-title":"Exp Eye Res"},{"key":"6354_CR16","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.1016\/s0161-6420(00)00090-7","volume":"107","author":"S Shah","year":"2000","unstructured":"Shah S, Spedding C, Bhojwani R, Kwartz J, Henson D, McLeod D (2000) Assessment of the diurnal variation in central corneal thickness and intraocular pressure for patients with suspected glaucoma. Ophthalmology 107:1191\u20131193. https:\/\/doi.org\/10.1016\/s0161-6420(00)00090-7","journal-title":"Ophthalmology"},{"key":"6354_CR17","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1136\/bjo.2005.079285","volume":"90","author":"P Fogagnolo","year":"2006","unstructured":"Fogagnolo P, Rossetti L, Mazzolani F, Orzalesi N (2006) Circardian variations in central corneal thickness and intraocular pressure in patients with glaucoma. Br J Ophthalmol 90:24\u201328. https:\/\/doi.org\/10.1136\/bjo.2005.079285","journal-title":"Br J Ophthalmol"},{"key":"6354_CR18","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1097\/00003226-200304000-00004","volume":"22","author":"R Du Toit","year":"2003","unstructured":"Du Toit R, Vega JA, Fonn D, Simpson T (2003) Diurnal variation of corneal sensitivity and thickness. Cornea 22:205\u2013209. https:\/\/doi.org\/10.1097\/00003226-200304000-00004","journal-title":"Cornea"},{"key":"6354_CR19","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1097\/IJG.0b013e31802b350f","volume":"16","author":"KE Hamilton","year":"2007","unstructured":"Hamilton KE, Pye DC, Aggarwala S, Evian S, Khosla J, Perera R (2007) Diurnal variation of central corneal thickness and Goldmann applanation tonometry estimates of intraocular pressure. J Glaucoma 16:29\u201335. https:\/\/doi.org\/10.1097\/IJG.0b013e31802b350f","journal-title":"J Glaucoma"},{"key":"6354_CR20","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1097\/OPX.0b013e3181981b7e","volume":"86","author":"SA Read","year":"2009","unstructured":"Read SA, Collins MJ (2009) Diurnal variation of corneal shape and thickness. Optom Vis Sci 86:170\u2013180. https:\/\/doi.org\/10.1097\/OPX.0b013e3181981b7e","journal-title":"Optom Vis Sci"},{"key":"6354_CR21","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1097\/00003226-200107000-00008","volume":"20","author":"Y Feng","year":"2001","unstructured":"Feng Y, Varikooty J, Simpson T (2001) Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography. Cornea 20:408\u2013483. https:\/\/doi.org\/10.1097\/00003226-200107000-00008","journal-title":"Cornea"},{"key":"6354_CR22","doi-asserted-by":"publisher","first-page":"e0237343","DOI":"10.1371\/journal.pone.0237343","volume":"15","author":"C Bruttini","year":"2020","unstructured":"Bruttini C, Verticchio Vercellin A, Klersy C, De Silvestri A, Tinelli C, Riva I, Oddone F, Katsanos A, Quaranta L (2020) The Mont Blanc Study: the effect of altitude on intra ocular pressure and central corneal thickness. PLoS ONE 15:e0237343. https:\/\/doi.org\/10.1371\/journal.pone.0237343","journal-title":"PLoS ONE"},{"issue":"2018","key":"6354_CR23","doi-asserted-by":"publisher","first-page":"4743721","DOI":"10.1155\/2018\/4743721","volume":"5","author":"M Perez-Bermejo","year":"2018","unstructured":"Perez-Bermejo M, Cervino A, Calvo-Maroto AM, Moscardo M, Murillo-Llorente M, Sanchis-Gimeno JA (2018) Corneal thickness response after anesthetic eye drops: our own results and meta-analysis. Biomed Res Int 5(2018):4743721. https:\/\/doi.org\/10.1155\/2018\/4743721","journal-title":"Biomed Res Int"},{"key":"6354_CR24","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.clae.2012.05.004","volume":"35","author":"KC Ogbuehi","year":"2012","unstructured":"Ogbuehi KC, Chijuka JC, Osuagwu UL (2012) Changes in central corneal thickness values after instillation of oxybuprocaine hydrochloride 0.4%. Cont Lens Anterior Eye 35:199\u2013202. https:\/\/doi.org\/10.1016\/j.clae.2012.05.004","journal-title":"Cont Lens Anterior Eye"},{"key":"6354_CR25","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/OPX.0000000000000449","volume":"92","author":"P Fernandez-Garcia","year":"2015","unstructured":"Fernandez-Garcia P, Cervi\u00f1o A, Quiles-Gui\u00f1au L, Albarran-Diego C, Garcia-Lazaro S, Sanchis-Gimeno JA (2015) Corneal thickness differences between sexes after oxybuprocaine eye drops. Optom Vis Sci 92:89\u201394. https:\/\/doi.org\/10.1097\/OPX.0000000000000449","journal-title":"Optom Vis Sci"},{"issue":"5","key":"6354_CR26","doi-asserted-by":"publisher","first-page":"915","DOI":"10.1038\/s41433-018-0033-3","volume":"32","author":"GW Belovay","year":"2018","unstructured":"Belovay GW, Goldberg I (2018) The thick and thin of the central corneal thickness in glaucoma. Eye (Lond) 32(5):915\u2013923. https:\/\/doi.org\/10.1038\/s41433-018-0033-3","journal-title":"Eye (Lond)"},{"key":"6354_CR27","doi-asserted-by":"publisher","unstructured":"Bograd A, Himmel I, Pfister IB, Seiler TG, Frueh BE, Tappeiner C (2023) Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device. Graefes Arch Clin Exp Ophthalmol. Epub ahead of print. https:\/\/doi.org\/10.1007\/s00417-023-06219-6","DOI":"10.1007\/s00417-023-06219-6"},{"key":"6354_CR28","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1111\/cxo.12865","volume":"102","author":"M Do\u011fan","year":"2019","unstructured":"Do\u011fan M, Ertan E (2019) Comparison of central corneal thickness measurements with standard ultrasonic pachymetry and optical devices. Clin Exp Optom 102:126\u2013130. https:\/\/doi.org\/10.1111\/cxo.12865","journal-title":"Clin Exp Optom"},{"key":"6354_CR29","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1007\/s10792-017-0543-1","volume":"38","author":"T Mansoori","year":"2018","unstructured":"Mansoori T, Balakrishna N (2018) Repeatability and agreement of central corneal thickness measurement with non-contact methods: a comparative study. Int Ophthalmol 38:959\u2013966. https:\/\/doi.org\/10.1007\/s10792-017-0543-1","journal-title":"Int Ophthalmol"},{"key":"6354_CR30","doi-asserted-by":"publisher","first-page":"1589","DOI":"10.1007\/s10792-018-0983-2","volume":"39","author":"NB Gokcinar","year":"2019","unstructured":"Gokcinar NB, Yumusak E, Ornek N, Yorubulut S, Onaran Z (2019) Agreement and repeatability of central corneal thickness measurements by four different optical devices and an ultrasound pachymeter. Int Ophthalmol 39:1589\u20131598. https:\/\/doi.org\/10.1007\/s10792-018-0983-2","journal-title":"Int Ophthalmol"},{"key":"6354_CR31","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.tjo.2013.04.007","volume":"3","author":"L Chao-Wen","year":"2013","unstructured":"Chao-Wen L, Tsing-Hong W, Yu-Hsuan H, Jehn-Yu H (2013) Agreement and repeatability of central corneal thickness measurements made by ultrasound pachymetry and anterior segment optical coherence tomography. Taiwan J Ophthalmol 3:98\u2013102. https:\/\/doi.org\/10.1016\/j.tjo.2013.04.007","journal-title":"Taiwan J Ophthalmol"},{"key":"6354_CR32","first-page":"5733","volume":"59","author":"Y Kim","year":"2018","unstructured":"Kim Y, Joung JY, Ryu SJ, Lim HW (2018) Analysis of which device is reliable for measuring central corneal thickness in novice examiner. Invest Ophthalmol Vis Sci 59:5733","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-023-06354-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-023-06354-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-023-06354-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,21]],"date-time":"2024-05-21T03:34:32Z","timestamp":1716262472000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-023-06354-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,11]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["6354"],"URL":"https:\/\/doi.org\/10.1007\/s00417-023-06354-0","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,11]]},"assertion":[{"value":"20 September 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 December 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 December 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 January 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the Fondazione IRCCS Policlinico San Matteo, Pavia, Italy, and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. The study was approved by The Ethics Committee of the Fondazione IRCCS Policlinico San Matteo, Pavia, Italy (ID # n.20170001732).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}