{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T01:40:47Z","timestamp":1793324447433,"version":"4.5.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2024,3,25]],"date-time":"2024-03-25T00:00:00Z","timestamp":1711324800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,3,25]],"date-time":"2024-03-25T00:00:00Z","timestamp":1711324800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"AST Products Inc"},{"name":"Universitat de Valencia"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2024,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>This study aimed to investigate the in vitro tolerance to decentration of biaspheric intraocular lens (IOLs) with refractive phase-ring extended depth-of-focus (EDOF) and diffractive trifocal designs.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This experimental study was carried out at the Department of Optics and Optometry and Vision Science, University of Valencia, Spain. The modulation transfer function (MTF) of the ETLIO130C EDOF and the TFLIO130C trifocal IOLs (AST Products Inc., Billerica, MA, USA) were determined at different levels of decentration for a given wavelength and pupil diameter using the PMTF optical bench (Lambda-X Ophthalmics, Nivelles, Belgium). The modulation transfer function (MTF) curves, the through-focus MTF curves, and the Strehl ratios were measured at 3-mm pupil aperture for 0.25-, 0.50- and 0.75-mm decentration.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The optical design of the trifocal TFLIO130C IOL is robust to small decentrations, with virtually no change in MTF response for 0.25 mm decentration. For greater decentration levels, the MTF response is slightly reduced with increasing decentration. The ETLIO130C EDOF design is robust to decentration, as the MTF response is only minimally affected when increasing the decentration up to 0.75 mm.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>MTF responses are slightly reduced with greater levels of decentration, but the range of focus provided by both trifocal and EDOF designs are preserved. The effects for average levels of decentration reported in the literature are minimum for both IOL designs.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s00417-024-06458-1","type":"journal-article","created":{"date-parts":[[2024,3,25]],"date-time":"2024-03-25T13:02:11Z","timestamp":1711371731000},"page":"2541-2550","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Tolerance to decentration of biaspheric intraocular lenses with refractive phase-ring extended depth of focus and diffractive trifocal designs"],"prefix":"10.1007","volume":"262","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8014-3279","authenticated-orcid":false,"given":"Alejandro","family":"Cervi\u00f1o","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8663-6373","authenticated-orcid":false,"given":"Jose Juan","family":"Esteve-Taboada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-Feng","family":"Chiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuan-Hui","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen-Chu","family":"Tseng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,3,25]]},"reference":[{"key":"6458_CR1","doi-asserted-by":"publisher","first-page":"6699","DOI":"10.1038\/s41598-021-86222-1","volume":"11","author":"Y Zhong","year":"2021","unstructured":"Zhong Y, Wang K, Yu X et al (2021) Comparison of trifocal or hybrid multifocal-extended depth of focus intraocular lenses: a systematic review and meta-analysis. Sci Rep 11:6699. https:\/\/doi.org\/10.1038\/s41598-021-86222-1","journal-title":"Sci Rep"},{"key":"6458_CR2","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1016\/j.ophtha.2021.03.013","volume":"128","author":"JM Schallhorn","year":"2021","unstructured":"Schallhorn JM, Pantanelli SM, Lin CC et al (2021) Multifocal and accommodating intraocular lenses for the treatment of presbyopia: a report by the American Academy of Ophthalmology. Ophthalmology 128:1469\u20131482","journal-title":"Ophthalmology"},{"key":"6458_CR3","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1364\/JOSAA.36.000759","volume":"36","author":"E Philippaki","year":"2019","unstructured":"Philippaki E, Gobin L, Mandoda J et al (2019) Optical evaluation of new-design multifocal IOLs with extended depth of focus. J Opt Soc Am A Opt Image Sci Vis 36:759\u2013767","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"6458_CR4","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1097\/j.jcrs.0000000000000869","volume":"48","author":"S Park","year":"2022","unstructured":"Park S, Kim MJ, Kim KH (2022) In vitro optical performance of multifocal and extended depth-of-focus intraocular lenses in spherical aberration conditions. J Cataract Refract Surg 48:616\u2013622","journal-title":"J Cataract Refract Surg"},{"key":"6458_CR5","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1177\/11206721221125081","volume":"33","author":"R Schmid","year":"2023","unstructured":"Schmid R, Fuchs C, Luedtke H, Borkenstein AF (2023) Depth of focus of four novel extended range of vision intraocular lenses. Eur J Ophthalmol 33:257\u2013261","journal-title":"Eur J Ophthalmol"},{"key":"6458_CR6","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1097\/OPX.0000000000001894","volume":"99","author":"R Schmid","year":"2022","unstructured":"Schmid R, Luedtke H, Borkenstein AF (2022) Enhanced depth-of-focus intraocular lenses: latest wavefront-shaped optics versus diffractive optics. Optom Vis Sci 99:335\u2013341","journal-title":"Optom Vis Sci"},{"key":"6458_CR7","doi-asserted-by":"publisher","first-page":"1552","DOI":"10.1097\/OPX.0000000000001004","volume":"93","author":"C Ortiz","year":"2016","unstructured":"Ortiz C, Esteve-Taboada JJ, Belda-Salmer\u00f3n L et al (2016) Effect of decentration on the optical quality of two intraocular lenses. Optom Vis Sci 93:1552\u20131559","journal-title":"Optom Vis Sci"},{"key":"6458_CR8","doi-asserted-by":"publisher","first-page":"808","DOI":"10.3928\/1081597X-20171004-02","volume":"33","author":"T Tandogan","year":"2017","unstructured":"Tandogan T, Son HS, Choi CY et al (2017) Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens. J Refract Surg 33:808\u2013812","journal-title":"J Refract Surg"},{"key":"6458_CR9","doi-asserted-by":"publisher","first-page":"532","DOI":"10.3928\/1081597X-20210518-03","volume":"37","author":"J Ruiz-Alcocer","year":"2021","unstructured":"Ruiz-Alcocer J, Mart\u00ednez-Alberquilla I, Rementer\u00eda-Capelo LA et al (2021) Changes in optical quality induced by tilt and decentration of a trifocal IOL and a novel extended depth of focus IOL in eyes with corneal myopic ablations. J Refract Surg 37:532\u2013537","journal-title":"J Refract Surg"},{"key":"6458_CR10","doi-asserted-by":"publisher","first-page":"112067212211288","DOI":"10.1177\/11206721221128864","volume":"26","author":"R Schmid","year":"2022","unstructured":"Schmid R, Luedtke H, Borkenstein AF (2022) Effect of decentration and tilt on four novel extended range of vision intraocular lenses regarding far distance. Eur J Ophthalmol. 26:11206721221128864. https:\/\/doi.org\/10.1177\/11206721221128864","journal-title":"Eur J Ophthalmol."},{"key":"6458_CR11","unstructured":"International Standard (2014) Ophthalmic implants-intraocular lenses-part 2: optical properties and test methods. International Organization for Standardization, Geneva"},{"key":"6458_CR12","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1097\/OPX.0000000000000893","volume":"93","author":"M Guillon","year":"2016","unstructured":"Guillon M, Dumbleton K, Theodoratos P et al (2016) The Effects of Age, Refractive Status, and Luminance on Pupil Size. Optom Vis Sci 93:1093\u20131100","journal-title":"Optom Vis Sci"},{"key":"6458_CR13","doi-asserted-by":"publisher","first-page":"1514","DOI":"10.1016\/S0886-3350(03)00467-X","volume":"29","author":"L Wang","year":"2003","unstructured":"Wang L, Dai E, Koch DD, Nathoo A (2003) Optical aberrations of the human anterior cornea. Cataract Refract Surg 29:1514\u20131521","journal-title":"Cataract Refract Surg"},{"key":"6458_CR14","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1016\/j.jcrs.2004.09.024","volume":"31","author":"GE Altmann","year":"2005","unstructured":"Altmann GE, Nichamin LD, Lane SS, Pepose JS (2005) Optical performance of 3 intraocular lens designs in the presence of decentration. J Cataract Refract Surg 31:574\u2013585","journal-title":"J Cataract Refract Surg"},{"key":"6458_CR15","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1038\/sj.eye.6702925","volume":"22","author":"HP Sandoval","year":"2008","unstructured":"Sandoval HP, Fernandez de Castro LE, Vroman DT, Solomon KD (2008) Comparison of visual outcomes, photopic contrast sensitivity, wavefront analysis, and patient satisfaction following cataract extraction and IOL implantation: aspheric vs spherical acrylic lenses. Eye 22:1469\u20131475","journal-title":"Eye"},{"key":"6458_CR16","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.ajo.2022.05.005","volume":"242","author":"J Xu","year":"2022","unstructured":"Xu J, Lin P, Zhang S et al (2022) Risk factors associated with intraocular lens decentration after cataract surgery. Am J Ophthalmol 242:88\u201395","journal-title":"Am J Ophthalmol"},{"key":"6458_CR17","doi-asserted-by":"publisher","first-page":"1768","DOI":"10.1016\/j.jcrs.2011.04.028","volume":"37","author":"A Crnej","year":"2011","unstructured":"Crnej A, Hirnschall N, Nishi Y et al (2011) Impact of intraocular lens haptic design and orientation on decentration and tilt. J Cataract Refract Surg 37:1768\u20131774","journal-title":"J Cataract Refract Surg"},{"key":"6458_CR18","doi-asserted-by":"publisher","unstructured":"Montrimas A, \u017demaitien\u0117 R, Yao K, Grzybowski A (2023) Chord mu and chord alpha as postoperative predictors in multifocal intraocular lens implantation. Graefes Arch Clin Exp Ophthalmol 6. https:\/\/doi.org\/10.1007\/s00417-023-06098-x","DOI":"10.1007\/s00417-023-06098-x"},{"key":"6458_CR19","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1016\/j.jcrs.2018.05.026","volume":"44","author":"Y Qi","year":"2018","unstructured":"Qi Y, Lin J, Leng L et al (2018) Role of angle \u03ba in visual quality in patients with a trifocal diffractive intraocular lens. J Cataract Refract Surg 44:949\u2013954","journal-title":"J Cataract Refract Surg"},{"key":"6458_CR20","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1007\/s00417-021-05403-w","volume":"260","author":"PB Baenninger","year":"2022","unstructured":"Baenninger PB, Rinert J, Bachmann LM et al (2022) Distribution of preoperative angle alpha and angle kappa values in patients undergoing multifocal refractive lens surgery based on a positive contact lens test. Graefes Arch Clin Exp Ophthalmol 260:621\u2013628","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"6458_CR21","doi-asserted-by":"publisher","first-page":"896","DOI":"10.3390\/jcm11030896","volume":"11","author":"G Cervantes-Coste","year":"2022","unstructured":"Cervantes-Coste G, Tapia A, Corredor-Ortega C et al (2022) The influence of angle alpha, angle kappa, and optical aberrations on visual outcomes after the implantation of a high-addition trifocal IOL. J Clin Med 11:896. https:\/\/doi.org\/10.3390\/jcm11030896","journal-title":"J Clin Med"},{"key":"6458_CR22","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1111\/ceo.13800","volume":"48","author":"JY Jiang","year":"2020","unstructured":"Jiang JY, Hodge C, Lawless M (2020) Understanding chord mu through a large population-based study. Clin Exp Ophthalmol 48:998\u20131001","journal-title":"Clin Exp Ophthalmol"},{"key":"6458_CR23","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1097\/j.jcrs.0000000000000490","volume":"47","author":"J Meng","year":"2021","unstructured":"Meng J, Du Y, Wei L et al (2021) Distribution of angle \u03b1 and angle \u03ba in a population with cataract in Shanghai. J Cataract Refract Surg 47:579\u2013584","journal-title":"J Cataract Refract Surg"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-024-06458-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-024-06458-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-024-06458-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,19]],"date-time":"2024-07-19T09:05:30Z","timestamp":1721379930000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-024-06458-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,25]]},"references-count":23,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024,8]]}},"alternative-id":["6458"],"URL":"https:\/\/doi.org\/10.1007\/s00417-024-06458-1","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,25]]},"assertion":[{"value":"24 September 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 March 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This article does not contain any studies with human participants performed by any of the authors.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"AC is a consultant for AST Products, Inc.; WCT and WL are employed by AST Products, Inc. and ICARES Medicus, Inc.; YFC and CHY are employed by ICARES Medicus, Inc. The authors report no other conflicts of interest in this work.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}