{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T18:15:51Z","timestamp":1787163351455,"version":"build-2736575974"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,11,13]],"date-time":"2024-11-13T00:00:00Z","timestamp":1731456000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,11,13]],"date-time":"2024-11-13T00:00:00Z","timestamp":1731456000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1007\/s00417-024-06682-9","type":"journal-article","created":{"date-parts":[[2024,11,13]],"date-time":"2024-11-13T00:01:42Z","timestamp":1731456102000},"page":"1035-1044","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["The role of corneal epithelial thickness map in detecting early keratoconus"],"prefix":"10.1007","volume":"263","author":[{"given":"Zizhen","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruilan","family":"Dong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yifei","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2720-7135","authenticated-orcid":false,"given":"Yueguo","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,11,13]]},"reference":[{"issue":"6","key":"6682_CR1","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1016\/j.clae.2016.05.003","volume":"39","author":"E Mas-Aixala","year":"2016","unstructured":"Mas-Aixala E, Gispets J, Lupon N, Cardona G (2016) The variability of corneal and anterior segment parameters in keratoconus. Cont Lens Anterior Eye 39(6):466\u2013470","journal-title":"Cont Lens Anterior Eye"},{"issue":"5","key":"6682_CR2","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1016\/j.jcrs.2009.11.012","volume":"36","author":"DP Pinero","year":"2010","unstructured":"Pinero DP, Alio JL, Aleson A, Escaf Vergara M, Miranda M (2010) Corneal volume, pachymetry, and correlation of anterior and posterior corneal shape in subclinical and different stages of clinical keratoconus. J Cataract Refract Surg 36(5):814\u2013825","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"6682_CR3","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","volume":"42","author":"YS Rabinowitz","year":"1998","unstructured":"Rabinowitz YS (1998) Keratoconus. Surv Ophthalmol 42(4):297\u2013319","journal-title":"Surv Ophthalmol"},{"issue":"6","key":"6682_CR4","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1016\/j.survophthal.2017.06.009","volume":"62","author":"V Mas Tur","year":"2017","unstructured":"Mas Tur V, MacGregor C, Jayaswal R, O\u2019Brart D, Maycock N (2017) A review of keratoconus: diagnosis, pathophysiology, and genetics. Surv Ophthalmol 62(6):770\u2013783","journal-title":"Surv Ophthalmol"},{"key":"6682_CR5","doi-asserted-by":"publisher","first-page":"804273","DOI":"10.3389\/fnins.2021.804273","volume":"15","author":"Y Dong","year":"2021","unstructured":"Dong Y, Li D, Guo Z, Liu Y, Lin P, Lv B, Lv C, Xie G, Xie L (2021) Dissecting the Profile of corneal thickness with Keratoconus Progression based on Anterior Segment Optical Coherence Tomography. Front Neurosci 15:804273","journal-title":"Front Neurosci"},{"issue":"10","key":"6682_CR6","doi-asserted-by":"crossref","first-page":"1367","DOI":"10.1016\/j.jcrs.2017.09.018","volume":"43","author":"JM Schallhorn","year":"2017","unstructured":"Schallhorn JM, Tang M, Li Y, Louie DJ, Chamberlain W, Huang D (2017) Distinguishing between contact lens warpage and ectasia: usefulness of optical coherence tomography epithelial thickness mapping (43, pg 60, 2017). J Cataract Refr Surg 43(10):1367\u20131368","journal-title":"J Cataract Refr Surg"},{"key":"6682_CR7","doi-asserted-by":"publisher","first-page":"5697343","DOI":"10.1155\/2016\/5697343","volume":"2016","author":"S Catalan","year":"2016","unstructured":"Catalan S, Cadarso L, Esteves F, Salgado-Borges J, Lopez M, Cadarso C (2016) Assessment of corneal epithelial thickness in asymmetric keratoconic eyes and normal eyes using Fourier Domain Optical Coherence Tomography. J Ophthalmol 2016:5697343","journal-title":"J Ophthalmol"},{"issue":"4","key":"6682_CR8","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/j.jcrs.2014.06.043","volume":"41","author":"C Temstet","year":"2015","unstructured":"Temstet C, Sandali O, Bouheraoua N, Hamiche T, Galan A, El Sanharawi M, Basli E, Laroche L, Borderie V (2015) Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus. J Cataract Refract Surg 41(4):812\u2013820","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"6682_CR9","doi-asserted-by":"publisher","first-page":"2159","DOI":"10.1016\/j.ophtha.2008.08.004","volume":"115","author":"Y Li","year":"2008","unstructured":"Li Y, Meisler DM, Tang M, Lu AT, Thakrar V, Reiser BJ, Huang D (2008) Keratoconus diagnosis with optical coherence tomography pachymetry mapping. Ophthalmology 115(12):2159\u20132166","journal-title":"Ophthalmology"},{"key":"6682_CR10","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.ajo.2018.09.008","volume":"197","author":"R Sella","year":"2019","unstructured":"Sella R, Zangwill LM, Weinreb RN, Afshari NA (2019) Repeatability and reproducibility of corneal epithelial thickness mapping with spectral-domain optical coherence tomography in normal and diseased cornea eyes. Am J Ophthalmol 197:88\u201397","journal-title":"Am J Ophthalmol"},{"issue":"2","key":"6682_CR11","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.jcrs.2015.09.021","volume":"42","author":"Y Li","year":"2016","unstructured":"Li Y, Chamberlain W, Tan O, Brass R, Weiss JL, Huang D (2016) Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography. J Cataract Refract Surg 42(2):284\u2013295","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"6682_CR12","doi-asserted-by":"publisher","first-page":"394","DOI":"10.4103\/0301-4738.116058","volume":"61","author":"H Matalia","year":"2013","unstructured":"Matalia H, Swarup R (2013) Imaging modalities in keratoconus. Indian J Ophthalmol 61(8):394\u2013400","journal-title":"Indian J Ophthalmol"},{"key":"6682_CR13","first-page":"842","volume":"73","author":"M Amsler","year":"1961","unstructured":"Amsler M (1961) [The forme fruste of keratoconus]. Wien Klin Wochenschr 73:842\u2013843","journal-title":"Wien Klin Wochenschr"},{"issue":"3","key":"6682_CR14","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1016\/j.ophtha.2003.06.020","volume":"111","author":"X Li","year":"2004","unstructured":"Li X, Rabinowitz YS, Rasheed K, Yang H (2004) Longitudinal study of the normal eyes in unilateral keratoconus patients. Ophthalmology 111(3):440\u2013446","journal-title":"Ophthalmology"},{"issue":"12","key":"6682_CR15","doi-asserted-by":"publisher","first-page":"840","DOI":"10.3928\/1081597X-20181012-01","volume":"34","author":"J Steinberg","year":"2018","unstructured":"Steinberg J, Siebert M, Katz T, Frings A, Mehlan J, Druchkiv V, B\u00fchren J, Linke SJ (2018) Tomographic and Biomechanical Scheimpflug Imaging for Keratoconus characterization: a validation of current indices. J Refract Surg 34(12):840\u2013","journal-title":"J Refract Surg"},{"issue":"7","key":"6682_CR16","doi-asserted-by":"publisher","first-page":"434","DOI":"10.3928\/1081597X-20170426-02","volume":"33","author":"R Ambr\u00f3sio","year":"2017","unstructured":"Ambr\u00f3sio R, Lopes BT, Faria-Correia F, Salomao MQ, B\u00fchren J, Roberts CJ, Elsheikh A, Vinciguerra R, Vinciguerra P (2017) Integration of Scheimpflug-based corneal tomography and biomechanical assessments for enhancing Ectasia Detection. J Refract Surg 33(7):434\u2013","journal-title":"J Refract Surg"},{"key":"6682_CR17","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/j.ajo.2018.08.005","volume":"195","author":"BT Lopes","year":"2018","unstructured":"Lopes BT, Ramos IC, Salomao MQ, Guerra FP, Schallhorn SC, Schallhorn JM, Vinciguerra R, Vinciguerra P, Price FW, Price MO et al (2018) Enhanced Tomographic Assessment to detect corneal Ectasia based on Artificial Intelligence. Am J Ophthalmol 195:223\u2013232","journal-title":"Am J Ophthalmol"},{"issue":"5","key":"6682_CR18","doi-asserted-by":"publisher","first-page":"E795","DOI":"10.1097\/OPX.0b013e3182504346","volume":"89","author":"T Schmoll","year":"2012","unstructured":"Schmoll T, Unterhuber A, Kolbitsch C, Le T, Stingl A, Leitgeb R (2012) Precise thickness measurements of Bowman\u2019s layer, epithelium, and tear film. Optom Vis Sci 89(5):E795\u2013802","journal-title":"Optom Vis Sci"},{"issue":"9","key":"6682_CR19","doi-asserted-by":"publisher","first-page":"600","DOI":"10.3928\/1081597X-20190806-03","volume":"35","author":"NJ Lu","year":"2019","unstructured":"Lu NJ, Chen D, Cui LL, Wang L, Chen SH, Wang QM (2019) Repeatability of Cornea and SubLayer thickness measurements using Optical Coherence Tomography in corneas of anomalous refractive status. J Refract Surg 35(9):600\u2013","journal-title":"J Refract Surg"},{"issue":"12","key":"6682_CR20","doi-asserted-by":"publisher","first-page":"1644","DOI":"10.1097\/j.jcrs.0000000000000348","volume":"46","author":"G Latifi","year":"2020","unstructured":"Latifi G, Mohammadi SS (2020) Repeatability and agreement of total corneal and sublayer pachymetry with 2 different algorithms of Fourier-domain optical coherence tomography in myopic and postphotorefractive keratectomy eyes. J Cataract Refract Surg 46(12):1644\u20131651","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"6682_CR21","doi-asserted-by":"publisher","first-page":"438","DOI":"10.3928\/1081597X-20150623-01","volume":"31","author":"DZ Reinstein","year":"2015","unstructured":"Reinstein DZ, Yap TE, Archer TJ, Gobbe M, Silverman RH (2015) Comparison of corneal epithelial thickness measurement between Fourier-Domain OCT and very high-frequency Digital Ultrasound. J Refract Surg 31(7):438\u2013U481","journal-title":"J Refract Surg"},{"issue":"3","key":"6682_CR22","doi-asserted-by":"publisher","first-page":"173","DOI":"10.3928\/1081597X-20130129-08","volume":"29","author":"KM Rocha","year":"2013","unstructured":"Rocha KM, Perez-Straziota CE, Stulting RD, Randleman JB (2013) SD-OCT analysis of regional epithelial thickness profiles in keratoconus, postoperative corneal ectasia, and normal eyes. J Refract Surg 29(3):173\u2013179","journal-title":"J Refract Surg"},{"issue":"11","key":"6682_CR23","doi-asserted-by":"publisher","first-page":"736","DOI":"10.3928\/1081597X-20151021-02","volume":"31","author":"DZ Reinstein","year":"2015","unstructured":"Reinstein DZ, Archer TJ, Urs R, Gobbe M, RoyChoudhury A, Silverman RH (2015) Detection of Keratoconus in clinically and algorithmically topographically normal fellow eyes using epithelial thickness analysis. J Refract Surg 31(11):736\u2013744","journal-title":"J Refract Surg"},{"issue":"6","key":"6682_CR24","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1097\/j.jcrs.0000000000000498","volume":"47","author":"Y Yang","year":"2021","unstructured":"Yang Y, Pavlatos E, Chamberlain W, Huang D, Li Y (2021) Keratoconus detection using OCT corneal and epithelial thickness map parameters and patterns. J Cataract Refract Surg 47(6):759\u2013766","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"6682_CR25","doi-asserted-by":"publisher","first-page":"604","DOI":"10.3928\/1081597X-20090610-06","volume":"25","author":"DZ Reinstein","year":"2009","unstructured":"Reinstein DZ, Archer TJ, Gobbe M (2009) Corneal epithelial thickness profile in the diagnosis of keratoconus. J Refract Surg 25(7):604\u2013610","journal-title":"J Refract Surg"},{"issue":"9","key":"6682_CR26","doi-asserted-by":"publisher","first-page":"OCT544","DOI":"10.1167\/iovs.15-18938","volume":"57","author":"M Tang","year":"2016","unstructured":"Tang M, Li Y, Chamberlain W, Louie DJ, Schallhorn JM, Huang D (2016) Differentiating Keratoconus and corneal warpage by analyzing focal change patterns in corneal topography, Pachymetry, and epithelial thickness maps. Invest Ophthalmol Vis Sci 57(9):OCT544\u2013549","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"2","key":"6682_CR27","first-page":"85","volume":"8","author":"F Ostadian","year":"2019","unstructured":"Ostadian F, Farrahi F, Mahdian Rad A (2019) Comparison of corneal epithelial thickness map measured by Spectral Domain Optical Coherence Tomography in Healthy, subclinical and early keratoconus subjects. Med Hypothesis Discov Innov Ophthalmol 8(2):85\u201391","journal-title":"Med Hypothesis Discov Innov Ophthalmol"},{"issue":"2","key":"6682_CR28","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.survophthal.2019.09.003","volume":"65","author":"ES Hwang","year":"2020","unstructured":"Hwang ES, Schallhorn JM, Randleman JB (2020) Utility of regional epithelial thickness measurements in corneal evaluations. Surv Ophthalmol 65(2):187\u2013204","journal-title":"Surv Ophthalmol"},{"issue":"12","key":"6682_CR29","doi-asserted-by":"publisher","first-page":"2425","DOI":"10.1016\/j.ophtha.2012.06.023","volume":"119","author":"Y Li","year":"2012","unstructured":"Li Y, Tan O, Brass R, Weiss JL, Huang D (2012) Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes. Ophthalmology 119(12):2425\u20132433","journal-title":"Ophthalmology"},{"issue":"4","key":"6682_CR30","doi-asserted-by":"publisher","first-page":"259","DOI":"10.3928\/1081597X-20100218-01","volume":"26","author":"DZ Reinstein","year":"2010","unstructured":"Reinstein DZ, Gobbe M, Archer TJ, Silverman RH, Coleman DJ (2010) Epithelial, stromal, and total corneal thickness in keratoconus: three-dimensional display with Artemis very-high frequency digital ultrasound. J Refract Surg 26(4):259\u2013271","journal-title":"J Refract Surg"},{"issue":"12","key":"6682_CR31","doi-asserted-by":"publisher","first-page":"1864","DOI":"10.1016\/j.jcrs.2013.05.048","volume":"39","author":"B Qin","year":"2013","unstructured":"Qin B, Chen S, Brass R, Li Y, Tang M, Zhang X, Wang X, Wang Q, Huang D (2013) Keratoconus diagnosis with optical coherence tomography-based pachymetric scoring system. J Cataract Refract Surg 39(12):1864\u20131871","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"6682_CR32","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1097\/ICO.0000000000002435","volume":"40","author":"I Toprak","year":"2021","unstructured":"Toprak I, Vega A, Del Alio JL, Espla E, Cavas F, Alio JL (2021) Diagnostic value of corneal epithelial and stromal thickness distribution profiles in Forme Fruste Keratoconus and Subclinical Keratoconus. Cornea 40(1):61\u201372","journal-title":"Cornea"},{"issue":"12","key":"6682_CR33","doi-asserted-by":"publisher","first-page":"1862","DOI":"10.1016\/j.ophtha.2018.06.020","volume":"125","author":"ES Hwang","year":"2018","unstructured":"Hwang ES, Perez-Straziota CE, Kim SW, Santhiago MR, Randleman JB (2018) Distinguishing highly asymmetric Keratoconus eyes using combined Scheimpflug and spectral-domain OCT analysis. Ophthalmology 125(12):1862\u20131871","journal-title":"Ophthalmology"},{"key":"6682_CR34","doi-asserted-by":"crossref","unstructured":"Kaya S, Schmidl D, Schmetterer L, Garhofer G, Werkmeister R (2015) Effect of hyaluronic acid on tear film thickness as assessed with ultra-high resolution optical coherence tomography.\u00a0Acta Ophthalmol 93(5):439\u2013443","DOI":"10.1111\/aos.12647"},{"issue":"1","key":"6682_CR35","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1097\/ICO.0000000000001745","volume":"38","author":"E Baghdasaryan","year":"2019","unstructured":"Baghdasaryan E, Tepelus TC, Marion KM, Bagherinia H, Sadda SR, Hsu HY (2019) Evaluation of corneal epithelial thickness imaged by high definition Optical Coherence Tomography in healthy eyes. Cornea 38(1):62\u201366","journal-title":"Cornea"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-024-06682-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-024-06682-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-024-06682-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,21]],"date-time":"2025-05-21T11:03:20Z","timestamp":1747825400000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-024-06682-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,13]]},"references-count":35,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,4]]}},"alternative-id":["6682"],"URL":"https:\/\/doi.org\/10.1007\/s00417-024-06682-9","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,13]]},"assertion":[{"value":"24 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 October 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 October 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the Ethics Committee of Peking University Third Hospital and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"All authors certify that they have no affiliations with or involvement in any organisation or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licencing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge, or beliefs) in the subject matter or materials discussed in this manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}