{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T14:58:27Z","timestamp":1792681107025,"version":"4.5.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T00:00:00Z","timestamp":1742601600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T00:00:00Z","timestamp":1742601600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Graefes Arch Clin Exp Ophthalmol"],"published-print":{"date-parts":[[2025,7]]},"DOI":"10.1007\/s00417-025-06764-2","type":"journal-article","created":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T23:31:18Z","timestamp":1742686278000},"page":"2049-2058","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A pilot study of deep learning for automatic contouring of sulcus-to-sulcus diameter in ultrasound biomicroscopy"],"prefix":"10.1007","volume":"263","author":[{"given":"Xiaohong","family":"Zheng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaokang","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ke","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingji","family":"Long","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingtao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanyuan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-9666-5763","authenticated-orcid":false,"given":"Ke","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,22]]},"reference":[{"key":"6764_CR1","doi-asserted-by":"publisher","first-page":"3981","DOI":"10.2147\/OPTH.S393422","volume":"16","author":"M Packer","year":"2022","unstructured":"Packer M (2022) The EVO ICL for Moderate Myopia: results from the US FDA Clinical Trial. Clin Ophthalmol 16:3981\u20133991","journal-title":"Clin Ophthalmol"},{"issue":"3","key":"6764_CR2","doi-asserted-by":"publisher","first-page":"169","DOI":"10.3928\/1081597X-20190118-01","volume":"35","author":"JF Alfonso","year":"2019","unstructured":"Alfonso JF, Fernandez-Vega-Cueto L, Alfonso-Bartolozzi B, Montes-Mico R, Fernandez-Vega L (2019) Five-year follow-up of correction of myopia: posterior Chamber Phakic intraocular Lens with a Central Port Design. J Refract Surg 35(3):169\u2013176","journal-title":"J Refract Surg"},{"issue":"7","key":"6764_CR3","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1016\/j.jcrs.2017.03.045","volume":"43","author":"G Steinwender","year":"2017","unstructured":"Steinwender G, Varna-Tigka K, Shajari M, Kohnen T (2017) Anterior subcapsular cataract caused by forceful irrigation during implantation of a posterior chamber phakic intraocular lens with a central hole. J Cataract Refract Surg 43(7):969\u2013974","journal-title":"J Cataract Refract Surg"},{"key":"6764_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.yoph.2011.03.047","volume-title":"Bilateral Explantation of Visian Implantable Collamer Lenses Secondary to Bilateral Acute Angle Closure Resulting From a Non-pupillary Block Mechanism","author":"SJ Fudemberg","year":"2011","unstructured":"Fudemberg SJ (2011) Bilateral explantation of Visian Implantable Collamer Lenses Secondary to bilateral Acute Angle Closure resulting from a non-pupillary block mechanism. Yearbook of Ophthalmology"},{"issue":"2","key":"6764_CR5","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.ophtha.2011.07.047","volume":"119","author":"DH Lee","year":"2012","unstructured":"Lee DH, Choi SH, Chung ES, Chung TY (2012) Correlation between preoperative biometry and posterior chamber phakic Visian Implantable Collamer Lens vaulting. Ophthalmology 119(2):272\u2013277","journal-title":"Ophthalmology"},{"issue":"4","key":"6764_CR6","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1016\/j.ajo.2011.06.031","volume":"153","author":"T Kojima","year":"2012","unstructured":"Kojima T, Yokoyama S, Ito M, Horai R, Hara S, Nakamura T et al (2012) Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy. Am J Ophthalmol 153(4):632\u2013637 637 e631","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"6764_CR7","doi-asserted-by":"publisher","first-page":"25","DOI":"10.5005\/jp-journals-10008-1105","volume":"6","author":"M He","year":"2012","unstructured":"He M, Wang D, Jiang Y (2012) Overview of Ultrasound Biomicroscopy. J Curr Glaucoma Pract 6(1):25\u201353","journal-title":"J Curr Glaucoma Pract"},{"issue":"1","key":"6764_CR8","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jcrs.2010.07.014","volume":"37","author":"PJ Dougherty","year":"2011","unstructured":"Dougherty PJ, Rivera RP, Schneider D, Lane SS, Brown D, Vukich J (2011) Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopy. J Cataract Refract Surg 37(1):13\u201318","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"6764_CR9","first-page":"1255","volume":"13","author":"MA Ansari","year":"2021","unstructured":"Ansari MA, Singh DK (2021) Monitoring social distancing through human detection for preventing\/reducing COVID spread. Int J Inform Technol 13(3):1255\u20131264","journal-title":"Int J Inform Technol"},{"issue":"1","key":"6764_CR10","doi-asserted-by":"publisher","first-page":"7","DOI":"10.3928\/1081597X-20201013-04","volume":"37","author":"S Brar","year":"2021","unstructured":"Brar S, Gautam M, Sute SS, Pereira S, Ganesh S (2021) Visual and refractive outcomes with the Eyecryl Phakic Toric IOL Versus the Visian Toric Implantable Collamer Lens: results of a 2-Year prospective comparative study. J Refract Surg 37(1):7\u201315","journal-title":"J Refract Surg"},{"issue":"8","key":"6764_CR11","doi-asserted-by":"publisher","first-page":"e943","DOI":"10.1111\/aos.14459","volume":"98","author":"R Wei","year":"2020","unstructured":"Wei R, Li M, Zhang H, Aruma A, Miao H, Wang X et al (2020) Comparison of objective and subjective visual quality early after implantable collamer lens V4c (ICL V4c) and small incision lenticule extraction (SMILE) for high myopia correction. Acta Ophthalmol 98(8):e943\u2013e950","journal-title":"Acta Ophthalmol"},{"issue":"1","key":"6764_CR12","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1186\/s12886-017-0663-4","volume":"17","author":"SW Nam","year":"2017","unstructured":"Nam SW, Lim DH, Hyun J, Chung ES, Chung TY (2017) Buffering zone of implantable collamer lens sizing in V4c. BMC Ophthalmol 17(1):260","journal-title":"BMC Ophthalmol"},{"issue":"4","key":"6764_CR13","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.jcrs.2009.11.017","volume":"36","author":"T Kawamorita","year":"2010","unstructured":"Kawamorita T, Uozato H, Kamiya K, Shimizu K (2010) Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter. J Cataract Refract Surg 36(4):617\u2013624","journal-title":"J Cataract Refract Surg"},{"key":"6764_CR14","unstructured":"Vehicle Detection in UAV Remote Sensing Image Based on Improved YOLOv5 (2022) 12th International Conference on Information Technology in Medicine and Education (ITME)v2022"},{"key":"6764_CR15","doi-asserted-by":"crossref","unstructured":"Pandiyan P, Thangaraj R, Subramanian M, Rahul R, Nishanth M, Palanisamy I Real-time monitoring of social distancing with person marking and tracking system using YOLO V3 model. Int J Sens Networks 2022(3): 38","DOI":"10.1504\/IJSNET.2022.121700"},{"issue":"2","key":"6764_CR16","doi-asserted-by":"publisher","first-page":"185","DOI":"10.3928\/1081597X-20090201-03","volume":"25","author":"DZ Reinstein","year":"2009","unstructured":"Reinstein DZ, Archer TJ, Silverman RH, Rondeau MJ, Coleman DJ (2009) Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using Artemis VHF digital ultrasound. J Refract Surg 25(2):185\u2013194","journal-title":"J Refract Surg"},{"issue":"9","key":"6764_CR17","doi-asserted-by":"publisher","first-page":"1685","DOI":"10.1016\/j.ophtha.2006.12.018","volume":"114","author":"J Oh","year":"2007","unstructured":"Oh J, Shin HH, Kim JH, Kim HM, Song JS (2007) Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy. Ophthalmology 114(9):1685\u20131688","journal-title":"Ophthalmology"},{"issue":"6","key":"6764_CR18","doi-asserted-by":"publisher","first-page":"986","DOI":"10.1016\/j.jcrs.2011.12.027","volume":"38","author":"K Petermeier","year":"2012","unstructured":"Petermeier K, Suesskind D, Altpeter E, Schatz A, Messias A, Gekeler F et al (2012) Sulcus anatomy and diameter in pseudophakic eyes and correlation with biometric data: evaluation with a 50\u00a0MHz ultrasound biomicroscope. J Cataract Refract Surg 38(6):986\u2013991","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"6764_CR19","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1016\/j.jcrs.2011.03.048","volume":"37","author":"J Biermann","year":"2011","unstructured":"Biermann J, Bredow L, Boehringer D, Reinhard T (2011) Evaluation of ciliary sulcus diameter using ultrasound biomicroscopy in emmetropic eyes and myopic eyes. J Cataract Refract Surg 37(9):1686\u20131693","journal-title":"J Cataract Refract Surg"},{"key":"6764_CR20","doi-asserted-by":"crossref","unstructured":"Dong J, Yao J, Chang S, Kanclerz P, Khoramnia R, Wang X (2023) Evaluation of ocular diameter parameters using swept-source Optical Coherence Tomography. Med (Kaunas) ; 59(5)","DOI":"10.3390\/medicina59050899"},{"issue":"6","key":"6764_CR21","doi-asserted-by":"publisher","first-page":"2689","DOI":"10.1007\/s10792-017-0757-2","volume":"38","author":"F Matarazzo","year":"2018","unstructured":"Matarazzo F, Day AC, Fernandez-Vega Cueto L, Maurino V (2018) Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing. Int Ophthalmol 38(6):2689\u20132692","journal-title":"Int Ophthalmol"},{"issue":"12","key":"6764_CR22","doi-asserted-by":"publisher","first-page":"3070","DOI":"10.4103\/ijo.IJO_3030_20","volume":"68","author":"A Srirampur","year":"2020","unstructured":"Srirampur A, Mansoori T, Balijepalli P, Gadde AK (2020) Management of anisocoria and high vault in an eye with implantable collamer lens. Indian J Ophthalmol 68(12):3070\u20133072","journal-title":"Indian J Ophthalmol"},{"key":"6764_CR23","unstructured":"Social Distancing Detection AI System using YOLO (2023) International Conference on Computer, Electronics & Electrical Engineering & their Applications (IC2E3); 8\u20139 June 20232023"},{"issue":"7","key":"6764_CR24","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1016\/j.jcrs.2011.01.024","volume":"37","author":"S Yokoyama","year":"2011","unstructured":"Yokoyama S, Kojima T, Horai R, Ito M, Nakamura T, Ichikawa K (2011) Repeatability of the ciliary sulcus-to-sulcus diameter measurement using wide-scanning-field ultrasound biomicroscopy. J Cataract Refract Surg 37(7):1251\u20131256","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"6764_CR25","doi-asserted-by":"publisher","first-page":"380","DOI":"10.3928\/1081597X-20200513-02","volume":"36","author":"Q Chen","year":"2020","unstructured":"Chen Q, Tan W, Lei X, Pan C, Jin L, Zeng Q et al (2020) Clinical prediction of Excessive Vault after Implantable Collamer Lens Implantation using ciliary body morphology. J Refract Surg 36(6):380\u2013387","journal-title":"J Refract Surg"}],"container-title":["Graefe's Archive for Clinical and Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-025-06764-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00417-025-06764-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00417-025-06764-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T08:07:06Z","timestamp":1757146026000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00417-025-06764-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,22]]},"references-count":25,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["6764"],"URL":"https:\/\/doi.org\/10.1007\/s00417-025-06764-2","relation":{},"ISSN":["0721-832X","1435-702X"],"issn-type":[{"value":"0721-832X","type":"print"},{"value":"1435-702X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,22]]},"assertion":[{"value":"20 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 January 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in this study involving human participants were in accordance with the tenets of the Declaration of Helsinki and was approved by the ethics committee of the Eye and ENT Hospital of Fudan University (NO. ky2021018).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}